TSC FR103S 1.0 amp. fast recovery rectifier Datasheet

FR101S THRU FR107S
1.0 AMP. Fast Recovery Rectifiers
Voltage Range
50 to 1000 Volts
Current
1.0 Ampere
A-405
Features
Low forward voltage drop
High current capability
High reliability
High surge current capability
Mechanical Data
Cases: Molded plastic
Epoxy: UL 94V-0 rate flame retardant
Lead: Axial leads, solderable per MILSTD-202, Method 208 guaranteed
Polarity: Color band denotes cathode end
High temperature soldering guaranteed:
260℃/10 seconds/.375”,(9.5mm) lead
lengths at 5 lbs.,(2.3kg) tension
Weight: 0.22gram
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Symbol FR
FR
Type Number
101S 102S
Maximum Recurrent Peak Reverse Voltage
50
100
VRRM
Maximum RMS Voltage
35
70
VRMS
Maximum DC Blocking Voltage
100
50
VDC
Maximum Average Forward Rectified
Current .375”(9.5mm) Lead Length
@TA = 55℃
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method )
Maximum Instantaneous Forward Voltage
@ 1.0A
Maximum DC Reverse Current @ TA=25℃
at Rated DC Blocking Voltage @ TA=100℃
Maximum Reverse Recovery Time ( Note 1 )
Typical Junction Capacitance ( Note 2 )
Typical Thermal Resistance ( Note 3 )
Operating Temperature Range
Storage Temperature Range
FR
103S
200
140
200
FR
104S
400
280
400
FR
105S
600
420
600
FR
106S
800
560
800
FR Units
107S
1000
V
700
V
1000
V
I(AV)
1.0
A
IFSM
30
A
VF
1.2
V
IR
5.0
100
uA
uA
nS
pF
O
C/W
℃
℃
Trr
Cj
RθJA
TJ
TSTG
150
250
10
90
-65 to +150
-65 to +150
Notes: 1. Reverse Recovery Test Conditions: IF=0.5A, IR=1.0A, IRR=0.25A
2. Measured at 1 MHz and Applied Reverse Voltage of 4.0 Volts D.C.
3. Mount on Cu-Pad Size 5mm x 5mm on P.C.B.
- 394 -
500
RATINGS AND CHARACTERISTIC CURVES (FR101S THRU FR107S)
FIG.2- MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
FIG.1- MAXIMUM FORWARD CURRENT DERATING
CURVE
PEAK FORWARD SURGE CURRENT. (A)
AVERAGE FORWARD CURRENT. (A)
1.0
0.75
0.5
Single Phase
Half Wave 60Hz
Resistive or
Inductive Load
0.375" (9.5mm)
Lead Length
0.25
50
40
30
8.3ms Single Half Sine Wave
JEDEC Method
20
10
0
0
0
25
50
75
100
125
150
175
1
2
4
6
8
10
20
40
60 80 100
o
AMBIENT TEMPERATURE. ( C)
NUMBER OF CYCLES AT 60Hz
FIG.4- TYPICAL JUNCTION CAPACITANCE
FIG.3- TYPICAL FORWARD CHARACTERISTICS
20
90
Tj=25oC
Pulse Width=300 s
1% Duty Cycle
JUNCTION CAPACITANCE.(pF)
INSTANTANEOUS FORWARD CURRENT. (A)
10
3.0
1.0
0.3
50
30
20
Tj=25 0C
10
1
1
0.1
2
4
6
10
20
REVERSE VOLTAGE. (V)
0.03
0.01
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
FORWARD VOLTAGE. (V)
FIG.5- REVERSE RECOVERY TIME CHARACTERISTIC AND TEST CIRCUIT DIAGRAM
50W
NONINDUCTIVE
10W
NONINDUCTIVE
trr
+0.5A
(-)
DUT
(+)
50Vdc
(approx)
(-)
PULSE
GENERATOR
(NOTE 2)
1W
NON
INDUCTIVE
OSCILLOSCOPE
(NOTE 1)
0
-0.25A
(+)
NOTES: 1. Rise Time=7ns max. Input Impedance=
1 megohm 22pf
2. Rise Time=10ns max. Sourse Impedance=
50 ohms
- 395 -
-1.0A
1cm
SET TIME BASE FOR
5/ 10ns/ cm
40
60
100