2-Line Filters B84142-A*-S2 for Converters in Traction Systems ... B84142-A*-S18 Power line filters for dc systems Rated voltage 750 to 2000 V– Rated current 250 to 1000 A Construction ■ Two-line filter ■ Metal case Features ■ Easy to install ■ Space-saving design ■ Design based on EN 133 200, UL 1283, CSA 22.2 No.8 1986 ■ Optimized for long motor cables and operation under full load Applications ■ Trams, light rails ■ Subways Terminals ■ Busbars, tin-plated Marking Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, date code Minimum marking on packaging: Manufacturer’s logo, ordering code Typical circuit diagram L+ L+’ L_ L _’ LINE LOAD Traction Bahnseite side Inverter Umrichter 183 03/01 SSB1309-8 2-Line Filters B84142-A*-S2 for Converters in Traction Systems ... B84142-A*-S18 Technical data Rated voltage V R 750 V− (Type -S2) 1000 V− (Type -S3) 2000 V− (Type -S18) Rated current IR Referred to 60 °C ambient temperature Test voltage VP For 750 V− filters: 2000 V−, 60 s (L+/L−) 4900 V−, 60 s (L+||L−/case) 6000 V−, 2 s (L+||L−/case) For 1000 V− filters: 2500 V−, 60 s (L+/L−) 4900 V−, 60 s (L+||L−/case) 6000 V−, 2 s (L+||L−/case) For 2000 V− filters: 4000 V−, 60 s (L+/L−) 4900 V−, 60 s (L+||L−/case) 6000 V−, 2 s (L+||L−/case) Overload capability 1,6 · IR for 20 s or 2,0 · IR for 10 s Climatic category 40/100/21 (– 40 °C/+ 100 °C/21 days damp heat test) in accordance with EN 60068-1 Characteristics and ordering codes VR IR V− A 750 1000 2000 Terminal PV cross section mm2 W R typ 250 125 8 63 12 B84142-A250-S2 500 150 34 57 13 B84142-A500-S2 1000 320 66 33 26 B84142-A1000-S2 250 125 8 63 12 B84142-A250-S3 500 150 34 57 13 B84142-A500-S3 1000 320 66 33 26 B84142-A1000-S3 250 125 8 63 12 B84142-A250-S18 µΩ Approx. weight kg Ordering code 500 150 34 57 13 B84142-A500-S18 1000 320 66 33 26 B84142-A1000-S18 184 03/01 2-Line Filters B84142-A*-S2 for Converters in Traction Systems ... B84142-A*-S18 Dimensional drawing B84142-A250-S** PE M10 × 30 PE M10 × 30 25 ø11 5 5 40±1 40±1 15 15 360±2 91 300 60 36 120±0,5 60 120±0,5 + 2 2xM6;depth 2 × M6; 6 ofmm tief engagement an beiden 6 mm on both filter sides Stirnseiten LINE LOAD _ 190 Marking _ 165±1 80 30 140 110±0,5 5 + ø12 91 116 SSB1587-R 185 03/01 2-Line Filters B84142-A*-S2 for Converters in Traction Systems ... B84142-A*-S18 Dimensional drawing B84142-A500-S** PE M10 × 30 PE M10 × 30 30 ø11 5 5 40±1 40±1 15 15 360±2 91 300 60 36 120±0,5 60 120±0,5 + 2 2xM6;depth 2 × M6; 6 of mm tief engagement an beiden 6 mm on both filter sides Stirnseiten LINE LOAD _ 190 Marking _ 165±1 80 30 140 110±0,5 5 + ø12 91 116 SSB1588-Z 186 03/01 2-Line Filters B84142-A*-S2 for Converters in Traction Systems ... B84142-A*-S18 B84142-A1000-S** 86±3 86±3 ø14 40 ø14 20 20 40 410±2,5 40 350 60 61 290±1 PE M6 × 25 + 2 95±0,8 _ LINE LOAD _ 260 Marking 235±1 8 80 180±0,8 210 + 4xM6;depth of tief 4 × M6; 6 mm engagement an beiden 6 mm on both filter sides Stirnseiten 60 220 ø12 16 126 SSB1589-8 187 03/01 2-Line Filters B84142-A*-S2 for Converters in Traction Systems ... B84142-A*-S18 Insertion loss (typical values at Z = 50 Ω) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84142-A250-S2 ... -S18 B84142-A500-S2 ... -S18 B84142-A1000-S2 ... -S18 SSB1573-L 100 dB SSB1574-U 100 dB αe αe 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 10 4 10 5 10 6 10 7 Hz 10 8 f 0 4 10 188 03/01 10 5 10 6 10 7 Hz 10 8 f Herausgegeben von EPCOS AG Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet. Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschüre ersetzt die vorige Ausgabe. Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen. Published by EPCOS AG Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited. The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices. 1