Littelfuse M232008.XW Axial lead and cartridge fuses - designed to meti standard Datasheet

Axial Lead and Cartridge Fuses
Designed to METI Standard
RoHS
Pb
5 x 20 mm Medium-Acting Fuse 232 Series
• Designed to Japanese Standard JIS C6575.
• Available in Cartridge, Axial and Radial Lead Format.
• Available in ratings of 1A to 10A.
• RoHS compliant and Lead-Free version available, add XP suffix to
standard catalog number
ELECTRICAL CHARACTERISTICS:
% of Ampere
Rating
130%
160%
200%
1000%
Opening
Time
1 hour, Minimum
1 hour, Maximum
2 minutes, Maximum
.01 sec, Minimum
INTERRUPTING RATING:
1A-5A 10,000A @ 125VAC, 0.7-0.8 power factor
6.3A-10A 300A @ 125VAC, 0.7-0.8 power factor
100 amperes at 250 VAC, 0.7-0.8 power factor
ENVIRONMENTAL SPECIFICATIONS:
Operating temperature: -55˚C to 125˚C
Thermal Shock: MIL-STD-202F Method 107G, Test Condition B: (5
ORDERING INFORMATION:
RoHS compliant and Lead-Free version available, add XP suffix to
standard catalog number
Catalog
Number
0232 001.
0232 1.25
0232 01.6
0232 002.
0232 02.5
0232 003.
0232 3.15
0232 004.
0232 005.
0232 06.3
0232 008.
0232 010.
Ampere
Rating
1
1.25
1.6
2
2.5
3
3.15
4
5
6.3
8
10
Voltage
Rating*
125/250
125/250
125/250
125/250
125/250
125/250
125/250
125/250
125/250
125/250
125/250
125/250
Nominal
Resistance
Cold Ohms
0.0957
0.0707
0.0567
0.0385
0.0297
0.0257
0.0235
0.018
0.0145
0.0105
.0076
.0061
Nominal
Melting I2t
A2 Sec
1.41
4.22
7.14
8.47
14.25
17.65
22.55
38.75
58.25
92.85
187.5
298.5
cycles –65°C to +125°C)
Vibration: MIL-STD-202F Method 201A
Humidity: MIL-STD-202F Method 103B, Test Condition A. high relative
humidity (95%) and elevated temperature (40°C) for 240 hours.
Salt Spray: MIL-STD-202F Method 101D, Test Condition B
PHYSICAL SPECIFICATIONS:
Material: Body: Glass
Cap: Nickel Plated Brass
Leads: Tin Plated Copper
Terminal Strength: MIL-STD-202F Method 211A,
Test Condition A
Solderability: Reference IEC 60127 Second Edition 2003-01 Annex A
Product Marking: Cap 1: current and voltage rating.
Cap 2: Agency approval markings.
Packaging: Available in Bulk (v=5, H=100, M=1000 pcs/pkg) or on
Tape/Reel (MRET1=1000 pcs/reel).
*To order 125V rating, add part number suffix X125
422
w w w. l i t t e l f u s e . c o m
Axial Lead and Cartridge Fuses
Pb
5 x 20 mm Medium-Acting Fuse 232 Series
Agency Approvals
Certificate No.
Cartridge
NBK010702-E10480 A
NBK290502-E10480 C
Leaded
NBK010702-E10480 B
NBK290502-E10480 E
SU05001-2001
5.1+0.6
1A – 5A
125V 10,000A
6.3A – 10A 125V 300A
5.1+0.6
20+0.5
1A – 5A
125V 10,000A
6.3A – 10A 125V 300A
2
0232 000 XW
1A – 10A (125V)
25.0+0.5
0.64
20.64+2.0
1A – 10A
40
22.5 MAX
5.8 MAX
0232 000 XE2
0.65*
All dimensions in mm
Notes:
* Ratings above 6.3A
have 0.8 mm dia lead
1 For RoHS compliant parts
add suffix 'XP'
2 For RoHS compliant parts
add suffix 'P'
Average Time Current Curves
11
1A
1.25A
1.6A
2A
2.5A
3A
3.15A
4A
5A
6.3A
8A
10A
Certificate No.
5.2+0.1
-0.2
Ampere Range
10000
1000
100
TIME IN SECONDS
Agency Approvals
20+0.5
0232 0001
AXIAL LEAD AND
CARTRIDGE FUSES
RoHS
10
1
0.1
0.01
0.001
1
100
10
1000
CURRENT IN AMPERES
w w w. l i t t e l f u s e . c o m
423
Similar pages