Delta DPS-40AP-10A Total power 40w Datasheet

50(W) x 28(H) x 95(L) mm
DPS-40AP-10 A
Input
Voltage range
90~264Vac auto range
Frequency
47~63Hz
Efficiency
The average efficiency at 25%, 50%, 75% and 100%
load ≥ 87%
Input Current
Output
90~132Vac /12V/3.33A load ≤ 1.2A
180~264Vac / 12V/3.33A load ≤ 0.6A
12V
0A to 3.33A
Over-current
Auto recovery
Over-temperature
Latch
Short
Auto recovery
Over-voltage
Auto recovery
Operating temp.
0 to 50°C Full load ,60°C 80% load, 70°C 60% load
Storage temp.
-20 to 70℃
Operating humidity
10% - 90%
Storage humidity
10% - 95%
Protection
Environment
FEATURES
• Total power 40W
• 90-264Vac auto range input
• High reliability: >100,000 hours @ full load
and normal input (25 ℃)
• Protection: Short / Over-current / Over-voltage
/ Over-temperature
• CCC: 5000 meter
• Bulk Cap: JP Type
• Safety: UL/cUL, TUV, CB by Demko ,CCC
• EMI: CLASS B
DPS-40AP-10 A
Electrical Safety
UL/cUL, TUV, CB,CCC,CE, BSMI
refer to EN 60950-1
CE
In conformance with EMC Directive 2004/108/EC and Low Voltage
Directive 2006/95/EC
EMI: refer to CISPR 22 ,FCC ,VCCI:CLASS B
Air Discharge: ± 8KV min
Safety
Standards/Directives
ESD(IEC61000-4-2)
Contact Discharge: ±4KV min.
EMC
EFT(IEC61000- 4-4)
+/- 2KV
Common Mode:+/- 4KV
Surge(IEC61000-4-5)
Isolation
Input to Output
3.0KVac
Different Mode:+/- 2KV
▓Power de-rating curve