HITRON HSU200-Q050MII Auto-ranging ac input ac-dc 19" compatible double eurocard multi-output 200 watts switching mode power supply Datasheet

H HiTRON
AUTO-RANGING AC INPUT AC-DC 19" COMPATIBLE DOUBLE
EUROCARD MULTI-OUTPUT 200 WATTS SWITCHING MODE
POWER SUPPLIES HSU200 SERIES
FEATURES:
AUTO-RANGING AC INPUT
19" COMPATIBLE EUROCARD FORMAT
MEET THE SAFETY STANDARDS
EMI MEET CISPR PUB. 22 & FCC CLASS A
CE MARKING COMPLIANCE
6U X 12HP X 160MM DOUBLE EUROCARD
VMEbus STANDARD
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Auto-ranging 115Vac(90-132Vac) and
230Vac(180-264Vac).
Transient threshold typ. 150Vac.
Input Connector: DIN 41612 at rear.
Input Frequency: 47-63Hz
Inrush Current: Typ. 65.0A @ 230Vac.
Input Current: Typ. 3.3A@115Vac /1.6A@230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 & FCC Class A.
Hold-up Time: Typ. 26mS.
Power OK: Installed
Remote Inhibit: Installed.
Over Temp. Protection (OTP): Installed (Thermostat).
Power-On LED: Installed.
Earth leakage: Typ. 0.3 mA @230Vac.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ. 200 Watts.
Output Connector: DIN 41612 at rear.
Line Regulation: Typ. 0.2%.
Load Regulation: Main VO1 typ. ±1.0%.
Aux. VO2 typ. ±1-2.0%(MA).
Aux. VO3 typ. ±2-3.0%(PR).
Aux. VO4 typ. ±2-3.0%(PR).
Noise & Ripple: Typ. 1% peak to peak.
OVP: Available at main VO1 & Aux.VO2.
Adjustability: Available at VO1 & VO2.
Remote Sense: Installed at main VO1.
Output LED Indicators: Installed for all outputs.
Overload Protection (OLP): Fully protected against
output overload and short circuit. Typ. 130% full load.
Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 76-77.0%.
Switching Frequency: Typ. 100K Hz.
Circuit Topology: Forward circuit.
Transient Response: Output voltage returns in less than
1.5mS following a 25% load change.
Safety Standard: IEC 60950-1/UL 60950-1 Class I.
Power Density: 1.30 Watts / Cubic Inch.
Operating Temperature: 0 to +50°C at full load. Derates
linearly to +70°C at half load.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: Typ. 0.04%/°C.
Cooling: Free air convection.
Construction format: 12HP(TE) x 6U compatible double
Eurocard VMEbus standard format.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
In application
-55-
OUTPUT VOLTAGE / CURRENT RATINGS CHART
TRIPLE OUTPUT
MODEL NO.
HSU200-T050II
(HSU200-32)
HSU200-T050MI
(HSU200-33)
HSU200-T050DI
HSU200-T033EI
MAIN VO1 @#
Typ.
Volt.
AUX. VO2 @▲
Typ.
Volt.
AUX. VO3 ●
Typ.
Volt.
20.0A
5.0V
7.0A
12.0V
1.0A
12.0V
20.0A
5.0V
3.5A
24.0V
1.0A
12.0V
20.0A
25.0A
5.0V
3.3V
18.0A
17.0A
3.3V
5.0V
1.0A
1.0A
12.0V
12.0V
QUAD OUTPUT
MODEL NO.
HSU200-Q050III
(HSU200-40)
HSU200-Q050MII
(HSU200-42)
HSU200-Q050DII
HSU200-Q033EII
MAIN VO1 @#
Typ.
Volt.
AUX. VO2 @▲
Typ.
Volt.
AUX. VO3 ●
Typ.
Volt.
AUX. VO4 ●
Typ.
Volt.
20.0A
+5.0V
6.0A
+12.0V
1.0A
-12.0V
1.0A
+12.0V
20.0A
+5.0V
3.0A
+24.0V
1.0A
-12.0V
1.0A
+12.0V
20.0A
25.0A
+5.0V
+3.3V
15.0A
14.0A
+3.3V
+5.0V
1.0A
1.0A
-12.0V
-12.0V
1.0A
1.0A
+12.0V
+12.0V
Symbol: " " OVP built-in. "@" Adjustable. "#" Remote sensing. "▲" Magnetic Amplifier. "●" Installed with Post Regulator.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 2.43kg (5.36 lb.)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENTS
AC INPUT
ASSIGNMENT AC-L AC-N AC-G
TRIPLE/QUAD OUTPUT
+VO1
HSU200-T
P1-28 P1-30 P1-32 P2-4,6,8,10
HSU200-Q
P1-28 P1-30 P1-32 P2-4,6,8,10
+VO2
-VO3 +VO4
DC COM
ASSORTED SIGNAL
NC
SYS
LOG. VO1 VO1
Reset
INH. S(+) S(-)
P1-10,12,14,16,18
P1-8 P2-14 P2-32 P1-6
20,22,24,26
P1-10,12,24,16,18
P2-28,30 P2-16 P2-12 P2-18,20,22,24,26
P1-8 P2-14 P2-32 P1-6
20,22,24,26
P2-28,30 P2-16
-
Mating connector: DIN41612-H15 Female
-56-
P2-18,20,22,24,26
AC
Fail
P1-4
P1-4
Similar pages