3+1 Dual Output Digital Multi-Phase Controller
FEATURES
IR35204
DESCRIPTION

Ultra Low Quiescent Power Dual output 3+1 phase
PWM Controller

Intel VR12 Rev 1.7, VR12.5 Rev 1.5, IMVP8 Rev 1.2,
AMD SVID2, and Memory VR modes

Switching frequency from 194KHz to 2MHz per phase
in 56 steps

IR Efficiency Shaping Features including Dynamic
Phase Control and Automatic Power State Switching

Programmable 1-phase or 2-phase operation for Light
Loads and Active Diode Emulation for very Light
Loads

IR Adaptive Transient Algorithm (ATA) on both loops
minimizes output bulk capacitors and system cost

Auto-Phase Detection with PID Coefficient autoscaling

Fault Protection: OVP, UVP, OCP, OTP, CAT_FLT

I2C/SMBus/PMBus system interface for reporting of
Temperature, Voltage, Current & Power telemetry for
both loops

Multiple Time Programming (MTP) with integrated
charge pump for easy non-volatile programming

Compatible with 3.3V tri-state drivers

+3.3V supply voltage; -40 C to 85 C ambient
o
o
operation; -40 C to 125 C junction

Pb-Free, RoHS, 5x5mm 40-pin, 0.4mm pitch QFN
®
o
The IR35204 is a dual-loop digital multi-phase
buck controller designed for CPU voltage
®
regulation, and is fully compliant with Intel , VR12
2
Rev 1.7, VR12.5 Rev 1.5, IMVP8 Rev 1.2, and
AMD SVI2 REV 1.06 specifications.
The IR35204 includes IR’s Efficiency Shaping
Technology to deliver exceptional efficiency at
minimum cost across the entire load range. IR’s
Dynamic Phase Control adds/drops phases based
upon load current. The IR35204 can be configured
to enter 1 or 2-phase PS1 operation and active
diode emulation mode automatically or by
command.
IR’s unique Adaptive Transient Algorithm (ATA),
based on proprietary non-linear digital PWM
algorithms, minimizes output bulk capacitors.
o
APPLICATIONS

Intel® VR12, VR12.5 and IMVP8 (overclocking only),
AMD SVI2 based systems

Servers and High End Desktop CPU VRs

High Performance Graphics Processors, Memory VR
IR35204 has 127 possible address values for both
the PMBus and I2C bus interfaces. The device
configuration can be easily defined using the IR
PowIRCenter GUI, and is stored in the on-chip
Non-Volatile Memory (NVM). This reduces external
components and minimizes the package size.
The IR35204 provides extensive OVP, UVP, OCP,
OTP & CAT_FLT fault protection, and includes
thermistor based temperature sensing or per
phase temperature reporting when using the IR
powIRstage. The controller is designed to work
with either Rdson current sense PowIRstages or
with DCR current sense.
The IR35204 also includes numerous VR design
simplifying and differentiating features, like register
diagnostics, which enable fast time-to-market.
ORDERING INFORMATION
Base Part
Number
Package Type
IR35204
Standard Pack
Orderable
Part Number
Form
Quantity
40-pin, QFN 5 mm x 5 mm
Tape and Reel
3000
IR35204MxxyyTRP1
IR35204
40-pin, QFN 5 mm x 5 mm
Tape and Reel
3000
IR35204MTRPBF
IR35204
40-pin, QFN 5 mm x 5 mm
Tray
4900
IR35204MTYPBF
Notes:
1.
2.
Customer Specific Configuration File, where xx = Customer ID and yy = Configuration File (Codes assigned by IR Marketing).
IR35204 is not intended for application where ultra low power PS4 shutdown functionality is required.
1
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
ORDERING INFORMATION
IR35204M         
P/PBF – Lead Free
TR – Tape & Reel / TY - Tray
yy – Configuration File ID
xx – Customer ID
RCSP
IRTN 1
ISEN 1
IRTN2
ISEN 2
IRTN3
ISEN3
IRTN1_L2
ISEN1_L2
RCSP_L2
Package Type (QFN)
40
39
38
37
36
35
34
33
32
31
RCSM
1
30 RCSM_L2
VRDY2
2
29
VSEN
3
28 VSEN_L2
VRTN
4
27 VRTN_L2
6
CFILT
7
VRDY1
8
EN_L2/CAT_FLT/PWROK
9
25 PWM3
24
PWM2
23
PWM1
22 TSEN2/VAUXSEN
41
10
GN D
13
14
15
16
17
18
19
20
ADDR_PROT
SM_AL ERT#
SM_DIO
SM_CLK
12
SV_ADDR/
VDDIO
SV_AL ERT#/
SVT
11
EN
21
VRHOT_ICRIT#
VINSEN
26 PWM1_L2
SV_DIO
TSEN1
IR35204
40 Pin 5x5 QFN
To p View
5
SV_CLK
I_IN
VCC
PIN_AL ERT#
Figure 1: IR35204 Pin Diagram
2
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
FUNCTIONAL BLOCK DIAGRAM
CFILT
VCC
VID_2
RCSP_L2
1.8V
RSCM_L2
LDO
AFE_2
VSEN_L2
Voltage
High
Speed
ADC
VRTN_L2
Vout1_Error
ITOT_2
PWM1
RCSP
RSCM
Voltage
High
Speed
ADC
AFE_1
VSEN
VRTN
Vout2_Error
PWM2
VID_1
PWM3
PWM Generator
ISEN1
IP1
IRTN1
Mode Control
ISEN2
Control
and
Monitoring
IP2
IRTN2
Σ
ISEN3
ITOT_1
PWM1_L2
Phase_
Period_1
Phase_
Period_2
IP3
IRTN3
Iout
Vin
Vout
ISEN1_L2
Temp
IP1_L2
ITOT_2
IRTN1_L2
Current &
Monitor ADC
Fault Bus
System Clock
IP1
System Clock
IP2
ADC Clocks
MUX Clocks
IP3
Phase_Period_1
IP1_L2
Phase_Period_2
VID_1
VID_2
I_IN
Reference,
Oscillator,
State Control,
Interfaces,
Registers and
MTP
TSEN
VINSEN
VAUXSEN/
TSEN2
V3_3
SM_DIO
SM_CLK
SV_CLK
SV_DIO
EN
ADDR_PROT
EN_L2/CAT_FLT/PWROK
Programming
ChargePump
Iout
Vin
Temp
Fault Bus
PIN_ALERT#
SV_ADDR/VDDIO
SV_ALERT#
MTP
VRHOT_ICRIT#
VRDY1
VRDY2
Figure 2: IR35204 Block Diagram
3
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
IR35204
TYPICAL APPLICATION DIAGRAM
OPTIONAL
Rsense
Vcc_core
V
Vin1 12V
Vcc
Vin
RS-
RS+
CSA OUT
+3.3V
VCC
I_IN
GND
Boot
IR3555
PWM1
ISEN1
PWM
IRTN1
REFIN
IOUT
GND
TOUT
Vcc_core
Vcc
Vin
Rvin1_1
VINSEN
Rvin1_2
V_CPU_L1
Switch
L
O
A
D
Boot
IR3555
PWM2
ISEN2
PWM
IRTN2
REFIN
Switch
IOUT
GND
TOUT
Vcc_core
RCSP
Vcc
Vin
CCS
RCS
RCSM
+3.3V
Boot
IR3555
PWM3
ISEN3
PWM
IRTN3
REFIN
TOUT
IOUT
Switch
GND
VCC
IR35204
CFILT
VRTN
VSEN
TSEN
Vcc_core
CATFLT
To SMC
Vcc
Vin
V
SV_ALERT#
SV_DIO
SV_CLK
V
3. 3V
CPU Serial
Bus
SM_ALERT#
PIN_ALERT#
Boot
IR3555
PWM1_L2
ISEN1_L2
PWM
IRTN1_L2
REFIN
TOUT
IOUT
V_CPU_L2
Switch
GND
L
O
A
D
VRHOT_CRIT#
EN
V
From
System
TSEN2
V
SM_DIO
SM_CLK
V
I2C Bus
RCSP_L2
Rcs
VRDY1
VRDY2
ADDR_PROT
CCS
VSEN_L2
RCSM_L2
VRTN_L2
GND
Figure 3: VR using IR35204 Controller and IR3555 PowIR Stage in 3+1 Configuration
4
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
IR35204
PIN DESCRIPTIONS
PIN#
PIN NAME
TYPE
PIN DESCRIPTION
1
RCSM
A [O]
Resistor Current Sense Minus Loop#1. This pin is connected to an external network to set the
load line slope, bandwidth and temperature compensation for Loop 1.
2
VRDY2
D [O]
Voltage Regulator Ready Output (Loop #2). Open-drain output that asserts high when the VR
has completed soft-start to Loop #2 boot voltage. Pull-up to an external voltage through a
resistor.
3
VSEN
A [I]
Voltage Sense Input Loop#1. This pin is connected directly to the VR output voltage of Loop #1
at the load and should be routed differentially with VRTN.
4
VRTN
A [I]
Voltage Sense Return Input Loop#1. This pin is connected directly to Loop#1 ground at the
load and should be routed differentially with VSEN.
5
I_IN
A [I]
I in. Input current signal that ranges from 0 to 1Vdc indicating a maximum input current of 62.5A.
6
TSEN1
A [I]
7
CFILT
A [O]
1.8V Decoupling. A 1F capacitor on this pin provides decoupling for the internal 1.8V supply.
8
VRDY1
D [O]
Voltage Regulator Ready Output (Loop #1). Open-drain output that asserts high when the VR
has completed soft-start to Loop #1 boot voltage. Pull-up to an external voltage through a
resistor.
9
EN_L2
PWROK
CAT_FLT
D[I]
D[I]
D[O]
Power OK Input (AMD). An input that when low indicates to return to the Boot voltage and when
high indicates to use the SVI bus.
10
VINSEN
A [I]
Voltage Sense Input. This is used to detect and measure a valid input supply voltage (typically
4.5V-13.2V) to the VR.
11
SV_ADDR
VDDIO
A[I]
A[P]
12
SV_ALERT#
SVT
D [O]
13
SV_CLK
D [I]
Serial VID Clock Input. Clock input driven by the CPU Master.
14
SV_DIO
D [B]
Serial VID Data I/O. Is a bi-directional serial line over which the CPU Master issues commands to
slave/s and receives data back.
15
VRHOT_ICRIT#
D [O]
VRHOT_ICRIT# Output. Active low alert pin that can be programmed to assert if temperature or
average load current exceeds user-definable thresholds. Pull-up to an external voltage through a
resistor.
Temperature Sense Input Loop 1. An NTC network or the temperature reporting output from an
IR PowIRstage can be connected to this pin to measure temperature for VRHOT and OTP
shutdown. When connected to the IR PowIRstage’s temperature output; the scaled input voltage
to the controller needs to be at a gain of 4.88mV per degC and an offset of 0.365 Vdc so the
controller can correctly report temperature. Typically a 10kohm and 6.39kohm resistive divider is
used to accomplish the scaling between the power stage and the controller.
Enable Input for Loop #2. This pin may be configured as an Enable input for loop #2.
16
EN
17
ADDR_PROT
18
SM_ALERT#
5
Catastrophic Fault Output Pin. This pin may be used as a Catastrophic Fault CMOS Output Pin
that is driven to VCC under output OVP, NVM CRC errors or a TSEN fault input.
Serial VID Address. If present, a resistor to ground sets the offset to the SVID address set in
NVM. If not, the value stored in NVM is used. Requires a 0.01µF to ground for noise filtering.
VDDIO Input (AMD). This pin provides the voltage to which the SVT line and the SVD
Acknowledge are driven high.
Serial VID ALERT# (INTEL). SVID ALERT# is pulled low by the controller to alert the CPU of
new VR/12/12.5 Status. Pull-up to an external voltage through a resistor.
SVI Telemetry Output (AMD). Telemetry and VOTF information output by the IR35204
D [I]
D [B]/
D [O]
VR Enable Input. ENABLE is used to power-on the regulator, provided Vin and Vcc are present.
ENABLE is not pulled up in the controller. The polarity of the chip enable function is bit-settable to
either an active high or an active low configuration. When the controller is disabled, the controller
de-asserts VR READY and shuts down the regulator. ENABLE pin cannot be left
floating. ENABLE pin must be pulled high or low.
Bus Address & I2C Bus Protection. A resistor to ground on this pin sets the offset to the NVM
value of the I2C address if configured to do so. Subsequently, this pin becomes a logic input to
enable or disable communication on the I2C bus when protection is enabled. Requires a 0.01µF
to ground for noise filtering.
SMBus/PMBus Alert Line. Active low alert pin to indicate that the regulator status has changed.
Requires a pull-up. Ground if not used.
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
IR35204
PIN#
PIN NAME
TYPE
PIN DESCRIPTION
19
SM_DIO
D [B]
Serial Data Line I/O. I2C/SMBus/PMBus bi-directional serial data line. Ground if not used.
20
SM_CLK
D [I]
Serial Clock Line Input. I2C/SMBus/PMBus clock input. The interface is rated to 1 MHz. Ground
if not used.
21
PIN_ALERT#
D [O]
PIN_ALERT# Output. Active low alert pin that can be programmed to assert if the input power
exceeds user-defined threshold. Pull-up to an external voltage through a resistor.
Temperature Sense Input Loop #2. An NTC network or the temperature reporting output from
an IR PowIRstage can be connected to this pin to measure temperature for VRHOT. Float if not
used.
TSEN2
/VAUXSEN
A [I]
A [I]
23 – 25
PWM1 – PWM3
A [O]
Phase 1-3 Pulse Width Modulation Outputs. PWM signal pin which is connected to the input of
an external MOSFET gate driver. The power-up state is high-impedance until ENABLE goes
active.
26
PWM1_L2
A [O]
Loop 2 Phase 1 Pulse Width Modulation Output. PWM signal pin which is connected to the
input of an external MOSFET gate driver. The power-up state is high-impedance until ENABLE
goes active. Float if not used.
27
VRTN_L2
A [I]
Voltage Sense Return Input Loop#2. This pin is connected directly to Loop#2 ground at the
load and should be routed differentially with VSEN_L2. Connect to GND if not used.
28
VSEN_L2
A [I]
Voltage Sense Input Loop#2. This pin is connected directly to the VR output voltage of Loop #2
at the load and should be routed differentially with VRTN_L2. Connect to GND if not used.
29
VCC
A [P]
Input Supply Voltage. 3.3V supply to power the device.
30
RCSM_L2
A [O]
Resistor Current Sense Minus Loop#2. This pin is connected to an external network to set the
load line slope, bandwidth and temperature compensation for Loop #2. Connect to pin 31 with
10K resistor if not used
31
RCSP_L2
A [O]
Resistor Current Sense Positive Loop#2. This pin is connected to an external network to set
the load line slope, bandwidth and temperature compensation for Loop #2. Connect to pin 30
with 10K resistor if not used
32
ISEN 1_L2
A [I]
Loop 2 Phase 1 Current Sense Input. Loop 2 Phase 1 sensed current input (+). GND if not
used.
33
IRTN 1_L2
A [I]
Loop 2 Phase 1 Current Sense Return Input. Loop 2 Phase 1 sensed current input return (-).
GND if not used.
34
ISEN 3
A [I]
Phase 3 Current Sense Input. Phase 3 sensed current input (+).GND if not used.
35
IRTN 3
A [I]
Phase 3 Current Sense Return Input. Phase 3 sensed current input return (-).GND if not used.
36
ISEN 2
A [I]
Phase 2 Current Sense Input. Phase 2 sensed current input (+).GND if not used.
37
IRTN 2
A [I]
Phase 2 Current Sense Return Input. Phase 2 sensed current input return (-).GND if not used.
38
ISEN 1
A [I]
Phase 1 Current Sense Input. Phase 1 sensed current input (+).GND if not used.
39
IRTN 1
A [I]
Phase 1 Current Sense Return Input. Phase 1 sensed current input return (-).GND if not used.
40
RCSP
A [O]
Resistor Current Sense Positive Loop#1. This pin is connected to an external network to set
the load line slope, bandwidth and temperature compensation for Loop 1.
41
(PAD)
GND
22
Auxiliary Voltage Sense Input. Monitors an additional power supply to ensure that both the
IR35204 Vcc and other voltages (such as VCC to the driver) are operational. Float if not used.
Ground. Ground reference for the IC. The large metal pad on the bottom must be connected to
Ground.
Note 1: A - Analog; D – Digital; [I] – Input; [O] – Output; [B] – Bi-directional; [P] - Power
6
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
IR35204
ABSOLUTE MAXIMUM RATINGS
Supply Voltage (VCC)
GND-0.3V to 4.0V
RCSPx, RCSMx
0 to 2.2V
VSEN, VRTN, ISENx, IRTNx
GND-0.2V to VCC + 0.3V
CFILT, VINSEN, I_IN
GND-0.2V to 2.2V
TSENx
GND-0.3V to VCC
SV_CLK, SV_DIO, SV_ALERT#, SV_ADDR
GND-0.3V to VCC
VRDYx, ENx, ADDR_PROT, VRHOT_ICRIT#, PIN_ALERT#
GND-0.3V to VCC
PWMx,
GND-0.3V to 4.1V
SM_DIO, SM_CLK, SM_ALERT#
GND-0.3V to 5.5V
ESD Rating
Human Body Model
2000V
Machine Model
200V
Charge Device Model
1000V
Thermal Information
Thermal Resistance (θJA & θJC)
1
29°C/W & 3°C/W
Maximum Operating Junction Temperature
-40°C to +125°C
Maximum Storage Temperature Range
-65°C to +150°C
Maximum Lead Temperature (Soldering 10s)
300°C
Note: 1. θJA is measured with the component mounted on a high effective thermal conductivity test board in free air.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are
stress ratings only and functional operation of the device at these or any other conditions beyond those indicated in the
operational sections of the specifications are not implied.
7
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
ELECTRICAL SPECIFICATIONS
RECOMMENDED OPERATING CONDITIONS FOR RELIABLE OPERATION WITH MARGIN
Recommended Operating Ambient Temperature Range
-40°C to 85°C
Supply Voltage Range
+2.90V to +3.63V
The electrical characteristics table lists the spread of values guaranteed within the recommended operating
conditions. Typical values represent the median values, which are related to 25°C.
ELECTRICAL CHARACTERISTICS
PARAMETER
SYMBOL
MIN
TYP
MAX
2.90
3.3
3.63
V
-
48
-
mA
3.3V UVLO Turn-on Threshold
-
2.80
2.90
V
3.3V UVLO Turn-off Threshold
2.60
2.70
-
V
1
-
-
MΩ
Supply
CONDITIONS
UNIT
VCC/GND
Supply Voltage
Vcc
Supply Current
Ivcc
Input Voltage (4.5V-13.2V) Sense Input
No PWM switching
VINSEN
Input Impedance
Input Range
With 14:1 divider
0
0.857
1.1
V
UVLO Turn-on Programmable Range1
V12
With 14:1 divider
-
4.5 –13.2
-
V
1
With 14:1 divider
-
4.5 –13.2
-
V
14.3
14.6
14.9
V
-
1
-
MΩ
UVLO Turn-off Programmable Range
OVP Threshold (if enabled)
1
AUX Voltage Sense Input
VAUXSEN
Input Impedance1
UVLO Turn-on Threshold
1
VAUXSEN_on
0.642
0.664
0.686
mV
UVLO Turn-off Threshold
1
VAUXSEN_off
0.564
0.586
0.608
mV
Reference Voltage and DAC
Intel® VR12.5,VR12and
IMVP8 mode, and AMD
SVI2
VBoot Voltage Range
System Accuracy
(0 to 85°C ambient)
System Accuracy
(-40°C to 125°C junction)
Meets spec
V
VID = 2.005–3.04V
-1.1
-
1.1
%VID
VID = 1.0V–2.0V
-0.5
-
0.5
%VID
VID = 0.8 – 0.995V
-5
-
5
mV
VID = 0.25 –0.795V
-8
-
8
mV
VID = 2.005–3.04V
-1.65
-
1.65
%VID
VID = 1.0V–2.0V
-0.75
-
0.75
%VID
VID = 0.8 – 0.995V
-7.5
-
7.5
mV
VID = 0.25 –0.795V
-12
-
12
mV
-
96
-
MHz
0°C to 85°C
-2.5
-
2.5
%
+5
%
2000
kHz
Oscillator & PWM Generator
Internal Oscillator1
Frequency Accuracy
Frequency Accuracy
PWM Frequency Range
8
-40°C to 125°C
1
www.irf.com | © 2016 International Rectifier
-5
194
-
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
PARAMETER
MIN
TYP
MAX
UNIT
-
163
-
ps
For TSEN = 0 to 1.2V
96
100
104
µA
at 100°C (ideal NTC)
96
-
104
°C
-
4.88
-
mV/°
C
Offset Voltage
-
0.365
-
Vdc
Fault Threshold
1.45
PWM Resolution
SYMBOL
NTC Temperature Sense
TSEN_NTC
Output Current
Accuracy
CONDITIONS
1
1
Tout Temperature Sense
TSEN_IR3555
Input Voltage
For TSEN = 0 to 1.2V
Divider Ratio to interface IR3555 to
IR35204
Vdc
-
1:1.64
-
Input High Voltage
0.7
-
-
V
Input Low Voltage
-
-
0.35
V
-
-
±5
µA
Input High Voltage
0.65
-
-
V
Input Low Voltage
-
-
0.45
V
Hysteresis
-
95
-
mV
-
-
±1
µA
Input High Voltage
2.1
-
-
V
Input Low Voltage
-
-
0.8
V
Vpad = 0 to 3.6V
-
-
±1
µA
VCPU = 0.5V to 3.04V
-
-25 to
+100
-
µA
-
-50
-
µA
-
0 to 3.04
-
V
-
-100 to
100
-
mV
-
-0.1 to
VCC 0.65
-
V
-
0 to 1.25
-
V
96
100
104
µA
Digital Inputs – Low Vth Type 1
EN(_L2) (Intel), VRHOT_ICRIT# (during PoR),
Input Leakage Current
Vpad = 0 to 2V
Digital Inputs – Low Vth Type 2
SV_CLK, SV_DIO
Input Leakage Current
Vpad = 0 to 2V
Digital Inputs – LVTTL
SM_DIO, SM_CLK, EN(_L2), ADDR_PROT
Input Leakage
Remote Voltage Sense Inputs
VSENx, VRTNx
VSEN Input Current
VRTN Input Current
1
Differential Input Voltage Range
VRTN Input CM Voltage
Remote Current Sense Inputs
Voltage Range
VRTN = ±100mV
1
ISENx/IRTNx
1
Input Current Sense Input
I_IN
Voltage Range
Analog Address/Level Inputs
Output Current
9
ADDR_PROT,SV_ADDR
1
www.irf.com | © 2016 International Rectifier
Vpad = 0 to 1.2V
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
PARAMETER
SYMBOL
CMOS Outputs ― 3.3V
CONDITIONS
MIN
TYP
MAX
UNIT
VCC –
0.4
-
-
V
-
-
0.4
V
CAT_FLT
Output High Voltage
loh = -20mA
Output Low Voltage
lol = 20mA
Open-Drain Outputs – 4mA Drive
VRDY, SM_DIO, SM_ALERT#
Output Low Voltage
4mA
-
-
0.3
V
Output Leakage
Vpad = 0 to 3.6V
-
-
±5
µA
Open-Drain Outputs – 20mA Drive
VR_HOT_ICRIT#, SV_DIO, SV_ALERT#, PIN_ALERT#
1
Output Low Voltage
I = 20mA
-
-
0.26
V
I = 20mA
7
9
13
Ω
Vpad = 0 to 3.6V
-
-
±5
µA
Output Low Voltage (Tri-state mode)
I = -4mA
-
-
0.4
V
Output High Voltage (Tri-State mode)
I =+4mA
2.9
-
-
V
Tri-State Leakage
loop_x_pwm_en_ats = 0,
-
-
±1
µA
Input Voltage High
0.7
-
-
V
Input Voltage Low
-
-
0.35
V
10,000
nSec
On Resistance
1
Tri-State Leakage
Ileak
PWM I/O
PWMx
Vpad = 0 to Vcc
PWM Auto-Detect Inputs (when 3.3V Vcc is applied) – if enabled
AMD SVI2 Bus
Tperiod (SVC Period)1
SVC
47.6
SVI2 SVC Frequency1
SVC
0.1
20.0
21.0
MHz
Normal
-
100
-
kHz
Fast
-
400
-
kHz
Maximum
-
1000
-
kHz
-
0.69,
1.39,
2.78,
5.55,
11.1,
22.2,
44.6,
89.5
-
Hz
-
250
-
kHz
-
35.7
-
kHz
-
35.7
-
kHz
-
0 to
13.2
-
V
I2C/PMBus & Reporting
Bus Speed
1
Iout , Vout , Iin, Vin, Pin and
1
Temperature Filter Rate
Selectable
(Selected Frequency
applies to all
parameters)
1
Iout Update Rate
1
Vout Update Rate
1
Vin & Temperature Update Rate
Vin Range Reporting
10
1
www.irf.com | © 2016 International Rectifier
With 14:1 divider
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
PARAMETER
SYMBOL
Vin Accuracy Reporting
With 1% resistors
Vin Resolution Reporting -PMBUS
Vin Resolution Reporting –I2C
Vout Range Reporting
CONDITIONS
1
1
1
Vout Accuracy Reporting
1
TYP
MAX
UNIT
-2
-
+2
%
-
31.25
-
mV
-
125
-
mV
-
-
4
V
No load-line
Vout Resolution Reporting-PMBUS
1
1
Vout Resolution Reporting-I2C
Iout Per Phase Range Reporting
Iout Accuracy Reporting
MIN
Loop1 Iout Resolution Reporting1
PMBUS
%
Vout < 2V
-
1.95
-
mV
Vout < 4V
-
15.6
-
mV
0
-
62
A
Maximum load, all phase
active (based on DCR,
NTC and # active phases)
-
±2
-
%
*0.5A if >255.75A
-
0.25*
-
A
-
0.25
-
A
1
1
±0.5
Loop2 Iout Resolution Reporting1
PMBUS
Loop1 Iout Resolution Reporting-I2C
1
-
1
-
A
Loop2 Iout Resolution Reporting-I2C
1
-
0.5
-
A
-
31.25
-
mA
-
31.25
-
mA
Loop1 Iin Resolution Reporting-PMBUS
1
Loop2 Iin Resolution Reporting-PMBUS
1
Loop1 Iin Resolution Reporting-I2C
1
-
0.125
-
A
Loop2 Iin Resolution Reporting-I2C
1
-
0.0625
-
A
-
0.5
-
W
-
0.5
-
W
P_in Resolution Reporting-PMBUS
1
P_out Resolution Reporting-PMBUS
1
Temperature Range Reporting1
IR3555 mode
0
-
158
°C
Temperature Accuracy Reporting1
IR3555 mode
3.5
-
3.5
%
0
-
134
°C
-4
-
4
%
-
1
-
°C
Selectable
-
1.2,
1.275,
1.35,
2.5
-
V
Relative to VID
-
50 to
400
-
mV
-
160
-
ns
-
50 to
400
-
mV
Temperature Range Reporting
1
Temperature Accuracy Reporting
1
Temperature Resolution Reporting
At 100°C, with ideal NTC
1
Fault Protection
OVP Threshold During Start-up
(until output reaches 1V)
OVP Operating Threshold
(programmable)
OVP Filter Delay
1
Output UVP Threshold
(programmable)
11
1
1
www.irf.com | © 2016 International Rectifier
Relative to VID
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNIT
-
0 to 62
-
A
-
60
-
kHz
Selectable
-
0.69,
1.39,
2.78,
5.55,
11.1,
22.2,
44.6,
89.5
-
Hz
System excluding
DCR/sense resistor
-
±2
-
%
1
Fast OCP Range (per phase)
Fast OCP Filter Bandwidth
1
Slow OCP Filter Bandwidth
OCP System Accuracy
1
1
PIN_ALERT# Bandwidth
VR_HOT Range
OTP Range
2000
-
64 to
127
-
°C
OTP Range (added to
VR_HOT level)
-
0 to 31
-
°C
For Phase drop
-
4
-
kHz
3.3V ready to end of
configuration
-
0.4
ms
-
2
ms
-
3
-
µs
Loop bandwidth
dependent
-
5
-
µs
After reaching Boot
voltage
-
20
-
µs
1
1, 2
Hz
Dynamic Phase Control
Current Filter Bandwidth
1
Timing Information
Automatic Configuration from MTP
Automatic Trim Time
1
EN Delay (to ramp start)
t3-t2
t4-t3
1
VID Delay (to ramp start)
VRDY Delay
1
1
1
Notes:
1
Guaranteed by design.
2
OTP max setting with NTC TEMP SENSE is 134°C.
12
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
GENERAL DESCRIPTION
The IR35204 is a flexible, dual-loop, digital multiphase
PWM buck controller optimized to convert a 12V input
supply to the core voltage required by Intel high
performance microprocessors and DDR memory. It is
easily configurable for 1 to 3 phases of operation on
Loop #1 and 0 to 1 phase operation on Loop #2.
The unique partitioning of analog and digital circuits
within the IR35204 provides the user with easy
configuration capability while maintaining the required
accuracy and performance. Access to on-chip Multiple
Time Programming memory (MTP) to store the
IR35204 configuration parameters enables power
supply designers to optimize their designs without
changing external components.
OPERATING MODES
®
The IR35204 can be used for Intel VR12, VR12.5,
IMVP8 designs, AMD SVI2 and DDR Memory designs
without significant changes to the external
components (Bill of Materials). The required mode is
selected in MTP and the pin-out, VID table and
relevant functions are automatically configured. This
greatly reduces time-to-market and eliminates the
need to manage and inventory different PWM
controllers.
DIGITAL CONTROLLER & PWM
A linear Proportional-Integral-Derivative (PID)
digital controller provides the loop compensation for
system regulation. The digitized error voltage from
the high-speed voltage error ADC is processed by the
digital compensator. The digital PWM generator uses
the outputs of the PID and the phase current balance
control signals to determine the pulse width for
each phase on each loop. The PWM generator has
enough resolution to ensure that there are no limit
cycles. The compensator coefficients are user
configurable to enable optimized system response.
The compensation algorithm uses a PID with two
additional programmable poles. This provides the
digital equivalent of a Type III analog compensator.
IR35204
Dynamic load step-up and load step-down transients
require fast system response to maintain the output
voltage within specification limits. This is achieved by
a unique adaptive non-linear digital transient control
loop based on a proprietary algorithm.
MULTIPLE TIME PROGRAMMING MEMORY
The multiple time programming memory (MTP) stores
the device configuration. At power-up, MTP contents
are transferred to operating registers for access
during device operation. MTP allows customization
during both design and high-volume manufacturing.
MTP integrity is verified by Cyclic Redundancy Code
(CRC) checking on each power up. The controller will
not start up in the event of a CRC error.
The IR35204 offers up to 6 writes to configure basic
device parameters such as frequency, fault operation
characteristics, and boot voltage. This represents a
significant size and component saving compared to
traditional analog methods. The following pseudocode illustrates how to write the MTP:
# write data
Set MTP Command Register = WRITE,
Line Pointer = An unused line
Poll MTP Command Register until Operation = IDLE.
# verify data was written correctly
Issue a READ Command; then poll OTP Operation Register
till Operation = IDLE
Verify that the Read Succeeded
INTERNAL OSCILLATOR
The IR35204 has a single 96MHz internal oscillator
that generates all the internal system clock
frequencies required for proper device function. The
oscillator frequency is factory trimmed for precision,
and has extremely low jitter (Figure 4) even in lightload mode (Figure 5). A single internal oscillator is
used to set the switching frequency on each loop
independently.
ADAPTIVE TRANSIENT ALGORITHM (ATA)
13
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
Vdd
3+1 Dual Output Digital Multi-Phase Controller
VCORE
PWM3
PWM2
PWM1
Figure 4: Persistence plot of a 3Φ, 50A system
VCORE
IR35204
Lossless inductor DCR or precision resistor current
sensing is used to accurately measure individual
phase currents. Using a simple off-chip thermistor,
resistor and capacitor network for each loop, a
thermally compensated load line is generated to meet
the given power system requirement. A filtered
voltage, which is a function of the total load current
and the target load line resistance, is summed into
each voltage sense path to accomplish the Active
Voltage Positioning (AVP) function.
The IR35204 can also be used with Rdson current
sensing PowIRstages. This algorithm helps reduce
component by eliminating the need for the R-C sense
components. Also, the thermistor used for thermal
compensation would no longer be required, as this
function is inherently designed into the Rdson sensing
PowIRstages. The R-C network across the pins would
still be required.
VID DECODER
PWM1
Figure 5: Persistence plot in 1Φ, 10A
HIGH-PRECISION VOLTAGE REFERENCE
The internal high-precision voltage reference supplies
the required reference voltages to the VID DACs,
ADCs and other analog circuits. This factory trimmed
reference is guaranteed over temperature and
manufacturing variations.
The VID decoder receives a VID code from the CPU
that is converted to an internal code representing the
VID voltage. This block also outputs the signal for VR
disable if a VID shutdown code has been received.
®
The 8 bit VID code supports Intel VR12 & VR12.5
modes and VID settings are selectable as either
5mV/code or 10mV/code on each loop independently.
When AMD SVI2 mode is choosen, both loops will be
set to 6.25mV/code
MOSFET DRIVER, POWER STAGE AND
DRMOS COMPATIBILITY
The PWM output signals of the IR35204 are designed
for compatibility with industry standard +3.3V Tri-State
MOSFET drivers.
VOLTAGE SENSE
An error voltage is generated from the difference
between the target voltage, defined by the VID and
load line (if implemented), and the differential,
remotely sensed, output voltage. For each loop, the
error voltage is digitized by a high-speed, highprecision ADC. An anti-alias filter provides the
necessary high frequency noise rejection.
The gain and offset of the voltage sense circuitry for
each loop is factory trimmed to deliver the required
accuracy.
CURRENT SENSE
14
www.irf.com | © 2016 International Rectifier
I2C & PMBUS INTERFACE
An I2C or PMBus interface is used to communicate
with the IR35204. This two-wire serial interface
consists of clock and data signals, and operates as
fast as 1MHz. The bus provides read and write access
to the internal registers for configuration, and for
monitoring of operating parameters. The bus is also
used to program on-chip non-volatile memory (MTP)
to store operating parameters.
To ensure operation with multiple devices on the bus,
an exclusive address for the IR35204 is programmed
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
into MTP. The IR35204, additionally, supports pinprogramming of the address.
To protect customer configuration and information,
the I2C interface can be configured for either limited
access with a 16-bit software password, or completely
locked. Limited access includes both write and read
protection options. In addition, there is a telemetryonly mode which only allows reads from the telemetry
registers.
The IR35204 provides a hardware pin security option
to provide extra protection. The protect pin is shared
with the ADDR pin and is automatically engaged once
the address is read. The pin must be driven high to
disable protection. The pin can be enabled or disabled
by a configuration setting in MTP.
IR35204
The configuration file can be re-coded into an
I2C/PMBus master (e.g. a Test System) and loaded
into the IR35204 using the bus protocols described on
page 48.
REAL-TIME MONITORING
The IR35204 can be accessed through the use of
PMBus Command codes (described in Table 56), to
read the real time status of the VR system including
input voltage, output voltage, input and output current,
input and output power, efficiency, and temperature.
The IR35204 supports the Packet Error Checking
(PEC) protocol and a number of PMBus commands to
monitor voltages and currents. For more information,
refer to the PMBus Command Codes in Table 56.
IR POWIRCENTER GUI
The IR PowIRCenter GUI provides the designer with a
comprehensive design environment that includes
interactive tools to calculate VR efficiency and DC
error budget, design the thermal compensation and
feedback loop networks, and produce calculated Bode
plots and output impedance plots. The PowIRCenter
GUI environment is a key utility for design
optimization, debug, and validation of designs that
saves the designer significant time, allowing faster
time-to-market (TTM).
The PowIRCenter GUI allows real-time design
optimization and monitoring of key parameters such
as output current and power, input current and power,
efficiency, phase currents, temperature, and faults.
The IR PowIRCenter GUI also allows access to the
system configuration settings for switching frequency,
MOSFET driver compatibility, soft start rate, VID table,
PSI, loop compensation, transient control system
parameters, input under-voltage, output over-voltage,
output under-voltage, output over-current and overtemperature.
PROGRAMMING
Once a design is complete, the PowIRCenter
produces a complete configuration file.
15
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
THEORY OF OPERATION
IR35204
specific to the VR configuration, including trim
settings, soft start ramp rate and boot voltage.
OPERATING MODE
The IR35204 changes its functionality based on the
user-selected operating mode, allowing one device to
be used for multiple applications without significant
BoM changes. This greatly reduces the user’s design
cycles and Time-to-Market (TTM).
The functionality for each operating mode is
completely configurable by simple selections in MTP.
The mode configuration is shown in Table 1.
TABLE 1: MODE SELECTION
Mode
Description
VR12
Intel® VR12 (Selected via MTP).
VR12.5
Intel® VR12.5 (Selected via MTP).
IMVP8
Intel® IMVP8 (Selected via MTP).
SVI2
AMD SVI2 (Selected via MTP).
MPoL
Memory Mode, with Loop 2 output voltage = ½
Loop 1 output voltage.
Figure 6: Controller Startup and Initialization
Once the registers are loaded from MTP, the designer
can use I2C to re-configure the registers to suit the
specific VR design requirements if desired.
TEST MODE
DEVICE POWER-ON AND INITIALIZATION
The IR35204 is powered from a 3.3V DC supply.
Figure 6 shows the timing diagram during device
initialization. An internal LDO generates a 1.8V rail to
power the control logic within the device. During initial
startup, the 1.8V rail follows the rising 3.3V supply
voltage, proportional to an internal resistor tree. The
internal oscillator becomes active at t1 as the 1.8V rail
is ramping up. Until soft-start begins, the IR35204
PWM outputs are disabled in a high impedance state
to ensure that the system comes up in a known state.
The controller comes out of power-on reset (POR) at
t2 when the 3.3V supply is high enough for the internal
bias control to generate 1.8V. The contents of the
MTP are transferred to the registers by time t3 and the
automatic trim routines are complete by time t4. At this
time, if enabled in MTP and when the VINSEN voltage
is valid, the controller will detect the populated phases
by sensing the voltage on the PWM pins. If the
voltage is less than the Auto Phase Detect threshold
(unused PWMs are grounded), the controller assumes
the phase is unpopulated. The register settings and
number of phases define the controller performance
16
www.irf.com | © 2016 International Rectifier
Having the ADDR_PROT pin high as the IC goes
through 3.3V POR engages a special test mode in
which the I2C address changes to 0Ah. This allows
individual in-circuit programming of the controller. This
is specifically useful in multi-controller systems that
use a single I2C bus. Note that MTP will not load to
the working registers until the ADDR_PROT pin goes
low.
SUPPLY VOLTAGE
The controller is powered by the 3.3V supply rail.
Once initialization of the device is complete, steady
and stable supply voltage rails and a VR Enable
signal (EN) are required to change the controller into
an active state. The Enable signal is used to enable
the PWM signals and begin the soft start sequence
after the 3.3V and VIN supply rails are determined to
be within the defined operating bands. The polarity of
the chip enable function is bit-settable to either an
active high or an active low configuration. When the
controller is disabled by deactivating the Enable
signal, it de-asserts VR READY and shuts down the
regulator.
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
The recommended decoupling for the 3.3V is shown
in Figure 7. The Vcc pin should have a 0.1µF and
1µF X5R-type ceramic capacitors placed as close as
possible to the package.
Figure 9: VINSEN resistor divider network
Figure 7: Vcc 3.3V decoupling
The CFILT pin must have a 1µF, X5R type decoupling
capacitor connected close to the package as shown in
Figure 8.
If enabled, VAUXSEN can be used to sense an
auxiliary voltage like a 5V driver VCC, for
example. The on and off thresholds are adjusted by
selecting the correct divider network, R1 and R2.
Figure 10: VAUXSEN resistor divider network
Figure 8: CFILT decoupling
The IR35204 is designed to accommodate a wide
variety of input power supplies and applications and
offers programmability of the VINSEN turn-on/off
voltages.
TABLE 2: VINSEN TURN-ON/OFF VOLTAGE RANGE
1
Threshold
Range
Turn-on
4.5V to 13.1875V in 1/16V steps1
Turn-off
4.5V to 13.1875V in 1/16V steps1
Must not be programmed below 4.5V
The supply voltage on the VINSEN pin is compared
against a programmable threshold. Once the rising
VINSEN voltage crosses the turn-on threshold and EN
is asserted, all PWM outputs become active. The
VINSEN supply voltage is valid until it declines below
its programmed turn-off level.
A 14:1 attenuation network is connected to the
VINSEN pin as shown in Figure 9. Recommended
values for a 12V system are RVIN_1 = 13kΩ and RVIN_2
= 1kΩ, with a 1% tolerance or better. CVINSEN is
required to have a minimum 1nF for noise
suppression, with a maximum value of 10nF.
VAUX on and off thresholds are defined as:
VAUX_on = VAUXSEN_on*(1+R1/R2)
VAUX_off = VAUXSEN_off*(1+R1/R2)
With R2 set to 1KΩ, Table 3 shows the on and off
thresholds for various values of R1.
TABLE 3: VAUXSEN TURN-ON/OFF VOLTAGES
R1
KΩ
5.77
8.78
11.80
14.81
VAUX_on
Volt
4.50
6.50
8.50
10.50
VAUX_off
Volt
3.97
5.74
7.50
9.27
Telemetry for VAUX is provided with 8 bit read only
register, vaux_supply. VAUX_reported can be
calculated with the following formula:
VAUX_reported = vaux_supply(dec)*4.883E3*(1+R1/R2)
POWER-ON SEQUENCING
The VR power-on sequence is initiated when all of the
following conditions are satisfied:
17
www.irf.com | © 2016 International Rectifier

IR35204 Vcc (+3.3V rail) > VCC UVLO

Input Voltage (VINSEN rail) > Vin UVLO
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
IR35204

Aux Voltage (VAUXSEN rail) > VAUXSEN
UVLO
(if configured)ENABLE is HIGH

VR has no Over-current, Over-voltage, Overtemperature or Under-voltage faults
If Vboot = 0V, the VR will stay at 0V and will not softstart until the CPU issues a VID command to the loop.
In VR 13 mode, as soon as the IC is ready for SVID
communication, VR_READY will be asserted with
Vboot = 0V.

MTP transfer to configuration registers
occurred without parity error
Intel Boot Voltage
Once the above conditions are cleared, start-up
behavior is controlled by the operating mode.
The IR35204 Vboot voltage is fully vprogrammable in
MTP to the range specified in the Intel VID tables.
Table 14 and Table 15 show the Intel VID tables for
for 5mV and 10mV VID steps respectively.
TABLE 8: VBOOT RANGE
VCORE
Loop
Boot Voltage
Loop 1
Per Intel VR12 and VR12.5 VID table
Loop 2
Per Intel VR12 and VR12.5 VID table
VRRDY
Intel SVID Interface
ENABLE
®
Figure 11: Enable-based Startup
The IR35204 implements a fully compliant Intel VR12
& VR12.5 Serial VID (SVID) interface. This is a three®
wire interface between an Intel VR12 ,VR12.5 &
IMVP8 compliant processor and a VR that consists of
clock, data and alert# signals.
POWER-OFF SEQUENCING
When +12Vdc goes below controller turn-off
threshold, the controller tristates all PWM’s. When
enable goes low the controller ramps down Vout on
both loops as shown in Figure 12.
VCORE
The IR35204 architecture is based upon a digital core
and hence lends itself very well to digital
communications. As such, the IR35204 implements all
the required SVID registers and commands. The
IR35204 also implements many of the optional
commands and registers with very few exceptions.
The Intel CPU is able to detect and recognize the
extra functionality that the IR35204 provides and thus
®
gives the Intel VR 13/12/12.5/IMVP8 CPU
unparalleled ability to monitor and optimize its power.
The SVID address of the IR35204 defaults to 0. This
address may be re-programmed in MTP. An address
lock function prevents accidental overwrites of the
address.
VRRDY
The pseudo-code below illustrates the MTP address
programming:
ENABLE
Figure 12: Enable-based Shutdown
INTEL MODE
When the power-on sequence is initiated, and with
VBOOT set to > 0V, the output voltage will ramp to its
configured boot voltage and assert VRDY. The slew
rate to VBOOT is programmed per Table 21.
18
www.irf.com | © 2016 International Rectifier
# unlock the address register to write, then lock
Set Address_lock_bit=0
Write new SVID address
Set Address_lock_bit=1
Intel VID Offset
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
The output voltage can be offset instead of setting a
manual VID value, according to Table 9. This is
especially useful for memory applications where
voltages higher than the standard VID table may be
required.
TABLE 9: VID OFFSET
Parameter
Memory
Range
Step Size
Output
Voltage
R/W
-128 to
+127
1 VID code
Maximum allowed voltage is 3.04V (VR12.5)
Note that the Vmax register must be set appropriately
to allow the required output voltage offset.
IR35204
IMVP8 mode is selectable via MTP bit. The boot
voltage in IMVP8 mode is configured in the boot
register in 5mV steps compatible to VR12 mode VID
table i.e. Table 14 or in 10mV steps compatible to
VR12.5 mode VID table i.e. Table 15. In IMVP8 mode,
bit 3 of SVID register “Status 1” (10h) is defined as
“VID DAC high”. This bit when set is an indicator to
the CPU that the VR VID DAC is greater than 30mV
above a new VID recently set by an SetVID
command.
In IMVP8 mode, IR35204 does support PS4
command, however, it does not shut down the
circuitry to reduce quiescent power consumption to
<1mW. Thus, IR35204 is meant to be operated in
IMVP8 mode for overclocking applications only where
it is not expected for VR to shut down its circuitry to
reduce quiescent power consumption.
Intel Reporting Offsets
In addition to the mandatory features of the SVID bus,
the IR35204 provides optional volatile SVID registers
which allow the user to offset the reporting on the
SVID interface as detailed in Table 10.
TABLE 10: SVID OFFSET REGISTERS
Parameter
Memory
Range
Step size
Output Current
NVM
-4A to +3.75A
0.25A
Temperature
R/W
-32°C to +31°C
1°C
Loop Start-Up Sequence and Delay
IR35204 can be configured to enable both loops in
one of the following possible sequences:

Both loops start together.

Loop 2 follows Loop 1.
 Loop1 follows Loop 2.
If IR35204 is configured such that one loop follows the
other, the delay between the two loops can be
adjusted for following pre-defined intervals:
 0 mS, 0.25 mS, 0.5 mS, 1 mS, 2.5 mS, 5 mS,
10 mS.
All Call SUPPORT
Memory (MPoL) Mode
All Call for each loop of IR35204 can be configured in
following ways:
In MPoL mode the IR35204 configures Loop 2 VID to
50% of Loop 1. Communication with and control of the
IR35204 may occur either through the SVID interface
when an Intel SVID Master is present, or alternatively
through the I2C/SMBus/PMBus interface for non-Intel
applications.

0E and 0F.

0E only.

0F only.

No All Call
IR35204 can be configured to be used as VR for CPU
which is All Call 0F or Memory which is All Call 0E.
VR12.5 Operation
VR12.5 mode is selectable via MTP bit. The boot
voltage in VR12.5 is also selectable and can be taken
from the boot registers.
The IR35204 follows startup and timing requirements
as shown in Figure 13. When the power-on sequence
is initiated, and with VBOOT set to > 0V, both rails will
ramp to their configured voltages and assert
VR_READY_L1 and VR_READY_L2. The slew rates
for both loops are set independently per Table 21. If
tracking is required during the slew, then care must be
taken to ensure that the Loop 2 slew rate is set to ½ of
the Loop 1 slew rate. Typical MPoL start-up and shutdown waveforms are shown in Figure 14 and Figure
15.
IMVP8 Operation
19
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
TABLE 13: MPOL LOOP 2 START-UP DELAY
Loop 2 Delay
0 – 678.3usec in 2.66usec Steps
Figure 13: MPoL Startup
TABLE 12: MPOL START-UP TIMING
Time
Description
Min
Typ
TA
VR_EN to Loop 1 start
3µs
TB
Loop 2 delay
Table
TC
Voltage ramp complete
to VR_RDY_L1/L2
Max
1µs
Vout 1
Vout 2
Figure 14: MPoL Tracking Startup
Vout 1
Vout 2
Figure 15: MPoL Tracking Shutdown
In MPoL mode, Loop 2 start-up can be delayed
relative to Loop 1 according to 2.
20
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
Table 14: Intel VR12 VID Table – 5mV VID Step
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
FF
1.52
DA
1.335
B5
1.15
90
0.965
6B
0.78
FE
1.515
D9
1.33
B4
1.145
8F
0.96
6A
0.775
FD
1.51
D8
1.325
B3
1.14
8E
0.955
69
0.77
FC
1.505
D7
1.32
B2
1.135
8D
0.95
68
0.765
FB
1.5
D6
1.315
B1
1.13
8C
0.945
67
0.76
FA
1.495
D5
1.31
B0
1.125
8B
0.94
66
0.755
F9
1.49
D4
1.305
AF
1.12
8A
0.935
65
0.75
F8
1.485
D3
1.3
AE
1.115
89
0.93
64
0.745
F7
1.48
D2
1.295
AD
1.11
88
0.925
63
0.74
F6
1.475
D1
1.29
AC
1.105
87
0.92
62
0.735
F5
1.47
D0
1.285
AB
1.1
86
0.915
61
0.73
F4
1.465
CF
1.28
AA
1.095
85
0.91
60
0.725
F3
1.46
CE
1.275
A9
1.09
84
0.905
5F
0.72
F2
1.455
CD
1.27
A8
1.085
83
0.9
5E
0.715
F1
1.45
CC
1.265
A7
1.08
82
0.895
5D
0.71
F0
1.445
CB
1.26
A6
1.075
81
0.89
5C
0.705
EF
1.44
CA
1.255
A5
1.07
80
0.885
5B
0.7
EE
1.435
C9
1.25
A4
1.065
7F
0.88
5A
0.695
ED
1.43
C8
1.245
A3
1.06
7E
0.875
59
0.69
EC
1.425
C7
1.24
A2
1.055
7D
0.87
58
0.685
EB
1.42
C6
1.235
A1
1.05
7C
0.865
57
0.68
EA
1.415
C5
1.23
A0
1.045
7B
0.86
56
0.675
E9
1.41
C4
1.225
9F
1.04
7A
0.855
55
0.67
E8
1.405
C3
1.22
9E
1.035
79
0.85
54
0.665
E7
1.4
C2
1.215
9D
1.03
78
0.845
53
0.66
E6
1.395
C1
1.21
9C
1.025
77
0.84
52
0.655
E5
1.39
C0
1.205
9B
1.02
76
0.835
51
0.65
E4
1.385
BF
1.2
9A
1.015
75
0.83
50
0.645
E3
1.38
BE
1.195
99
1.01
74
0.825
4F
0.64
E2
1.375
BD
1.19
98
1.005
73
0.82
4E
0.635
E1
1.37
BC
1.185
97
1
72
0.815
4D
0.63
E0
1.365
BB
1.18
96
0.995
71
0.81
4C
0.625
DF
1.36
BA
1.175
95
0.99
70
0.805
4B
0.62
DE
1.355
B9
1.17
94
0.985
6F
0.8
4A
0.615
DD
1.35
B8
1.165
93
0.98
6E
0.795
49
0.61
DC
1.345
B7
1.16
92
0.975
6D
0.79
48
0.605
DB
1.34
B6
1.155
91
0.97
6C
0.785
47
0.6
21
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
46
0.595
37
0.52
28
0.445
19
0.37
0A
0.295
45
0.59
36
0.515
27
0.44
18
0.365
09
0.29
44
0.585
35
0.51
26
0.435
17
0.36
08
0.285
43
0.58
34
0.505
25
0.43
16
0.355
07
0.28
42
0.575
33
0.5
24
0.425
15
0.35
06
0.275
41
0.57
32
0.495
23
0.42
14
0.345
05
0.27
40
0.565
31
0.49
22
0.415
13
0.34
04
0.265
3F
0.56
30
0.485
21
0.41
12
0.335
03
0.26
3E
0.555
2F
0.48
20
0.405
11
0.33
02
0.255
3D
0.55
2E
0.475
1F
0.4
10
0.325
01
0.25
3C
0.545
2D
0.47
1E
0.395
0F
0.32
00
0
3B
0.54
2C
0.465
1D
0.39
0E
0.315
3A
0.535
2B
0.46
1C
0.385
0D
0.31
39
0.53
2A
0.455
1B
0.38
0C
0.305
38
0.525
29
0.45
1A
0.375
0B
0.3
22
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
Table 15: Intel VR12.5 VID Table – 10mV VID Step
VID
(HEX)
VOLTAGE
(V)
VID
(HEX)
VOLTAGE
(V)
VID
(HEX)
VOLTAGE
(V)
VID
(HEX)
VOLTAGE
(V)
VID
(HEX)
VOLTAGE
(V)
FF
3.04
E1
2.74
C3
2.44
A5
2.14
87
1.84
FE
3.03
E0
2.73
C2
2.43
A4
2.13
86
1.83
FD
3.02
DF
2.72
C1
2.42
A3
2.12
85
1.82
FC
3.01
DE
2.71
C0
2.41
A2
2.11
84
1.81
FB
3.00
DD
2.70
BF
2.40
A1
2.10
83
1.80
FA
2.99
DC
2.69
BE
2.39
A0
2.09
82
1.79
F9
2.98
DB
2.68
BD
2.38
9F
2.08
81
1.78
F8
2.97
DA
2.67
BC
2.37
9E
2.07
80
1.77
F7
2.96
D9
2.66
BB
2.36
9D
2.06
7F
1.76
F6
2.95
D8
2.65
BA
2.35
9C
2.05
7E
1.75
F5
2.94
D7
2.64
B9
2.34
9B
2.04
7D
1.74
F4
2.93
D6
2.63
B8
2.33
9A
2.03
7C
1.73
F3
2.92
D5
2.62
B7
2.32
99
2.02
7B
1.72
F2
2.91
D4
2.61
B6
2.31
98
2.01
7A
1.71
F1
2.90
D3
2.60
B5
2.30
97
2.00
79
1.70
F0
2.89
D2
2.59
B4
2.29
96
1.99
78
1.69
EF
2.88
D1
2.58
B3
2.28
95
1.98
77
1.68
EE
2.87
D0
2.57
B2
2.27
94
1.97
76
1.67
ED
2.86
CF
2.56
B1
2.26
93
1.96
75
1.66
EC
2.85
CE
2.55
B0
2.25
92
1.95
74
1.65
EB
2.84
CD
2.54
AF
2.24
91
1.94
73
1.64
EA
2.83
CC
2.53
AE
2.23
90
1.93
72
1.63
E9
2.82
CB
2.52
AD
2.22
8F
1.92
71
1.62
E8
2.81
CA
2.51
AC
2.21
8E
1.91
70
1.61
E7
2.80
C9
2.50
AB
2.20
8D
1.90
6F
1.60
E6
2.79
C8
2.49
AA
2.19
8C
1.89
6E
1.59
E5
2.78
C7
2.48
A9
2.18
8B
1.88
6D
1.58
E4
2.77
C6
2.47
A8
2.17
8A
1.87
6C
1.57
E3
2.76
C5
2.46
A7
2.16
89
1.86
6B
1.56
E2
2.75
C4
2.45
A6
2.15
88
1.85
6A
1.55
23
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
VID
(HEX)
VOLTAGE
(V)
VID
(HEX)
VOLTAGE
(V)
VID
(HEX)
VOLTAGE
(V)
VID
(HEX)
VOLTAGE
(V)
VID
(HEX)
VOLTAGE
(V)
69
1.54
53
1.32
3D
1.10
27
0.88
11
0.66
68
1.53
52
1.31
3C
1.09
26
0.87
10
0.65
67
1.52
51
1.30
3B
1.08
25
0.86
F
0.64
66
1.51
50
1.29
3A
1.07
24
0.85
E
0.63
65
1.50
4F
1.28
39
1.06
23
0.84
D
0.62
64
1.49
4E
1.27
38
1.05
22
0.83
C
0.61
63
1.48
4D
1.26
37
1.04
21
0.82
B
0.60
62
1.47
4C
1.25
36
1.03
20
0.81
A
0.59
61
1.46
4B
1.24
35
1.02
1F
0.80
9
0.58
60
1.45
4A
1.23
34
1.01
1E
0.79
8
0.57
5F
1.44
49
1.22
33
1.00
1D
0.78
7
0.56
5E
1.43
48
1.21
32
0.99
1C
0.77
6
0.55
5D
1.42
47
1.20
31
0.98
1B
0.76
5
0.54
5C
1.41
46
1.19
30
0.97
1A
0.75
4
0.53
5B
1.40
45
1.18
2F
0.96
19
0.74
3
0.52
5A
1.39
44
1.17
2E
0.95
18
0.73
2
0.51
59
1.38
43
1.16
2D
0.94
17
0.72
1
0.50
58
1.37
42
1.15
2C
0.93
16
0.71
0
0.00
57
1.36
41
1.14
2B
0.92
15
0.70
56
1.35
40
1.13
2A
0.91
14
0.69
55
1.34
3F
1.12
29
0.90
13
0.68
54
1.33
3E
1.11
28
0.89
12
0.67
24
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
IR35204
PHASING
The number of phases enabled on each loop of the
IR35204 is shown in Table 16. The phase of the PWM
outputs is automatically adjusted to optimize phase
interleaving for minimum output ripple. Phase
interleaving results in a ripple frequency that is the
product of the switching frequency and the number of
phases. A high ripple frequency results in reduced
ripple voltage, thereby minimizing the output filter
capacitance requirements, resulting in significant total
BOM cost reduction.
Figure 16.
TABLE 17: PHASE RELATIONSHIP
Phases
1
2
3
Phasing
180º
120º
TABLE 16: LOOP CONFIGURATION
Configuration
Loop 1
Loop 2
3+0
3-phases
-
2+0
2-phases
-
1+0
1-phase
-
3+1
3-phases
1-phase
2+1
2-phases
1-phase
1+1
1-phase
1-phase
UNUSED PHASES
Phases are disabled based upon the configuration
shown in Table 16. Disabled PWM outputs should
be left floating unless the auto-populate phase
detection feature is used. Unused phases should be
disconnected in reverse order to ensure a correct
phase relationship. E.g. a 3+0 configuration must
have PWMs on phase 3 disconnected in order to
operate in 2+0 mode. If phases 1 or 2 were
disconnected instead, the remaining phases would not
have a symmetrical relationship, leading to unreliable
performance. If the auto-populate phase detection
feature is used, unused PWM outputs should be
grounded so that their voltage is below the threshold
(phase is disabled). IR35204 automatically adjusts
the phase configuration to operate with the populated
phases (up to the configuration allowed by the
settings in Table 16).
Figure 16: 3-phase PWM interleaved operation
SWITCHING FREQUENCY
The phase switching frequency (Fsw) of the IR35204
is set by a user configurable register. The switching
frequency can be set indepently on each loop. The
switching frequency variation with register setting has
been plotted in Figure 17.
The IR35204 oscillator is factory trimmed to guarantee
high accuracy and very low jitter compared to analog
controllers.
In addition, the IR35204 detects the number of
populated phases at start-up by comparing the
voltage on the PWM pin against the phase detection
threshold. In order for populated phases to be
detected, the MOSFET drivers need to be powered up
before the VCC, +12Vin and Vaux to the IR35204
exceeds its POR threshold.
Typical PWM pulse phase relationships are shown in
Table 17 and
25
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
target voltage. The error voltage is digitized by a fast,
high-precision ADC.
As shown in Figure 19, the Vsen and Vrtn inputs have
a 20kΩ pull-up to an internal 1V rail. This causes
some current flow in the Vsen and Vrtn lines. To
minimize the offset created by this current flow, the
external series impedance on these lines needs to be
kept to a minimum.
Figure 17: Switching Frequency Variation with Register Setting
MOSFET DRIVER AND POWERSTAGE
SELECTION
The PWM signals from the active phases of the
IR35204 are designed to operate with industry
standard tri-state type drivers or PowIRstage devices.
The logic operation for these types of tri-state drivers
is depicted in Figure 18.
When in tri-state, the IR35204 floats the outputs so
that the voltage level is determined by an external
voltage divider which is typically inside the MOSFET
driver. Sometimes external resistors are added to
improve the speed of the PWM signal going into tristate.
Note that the PWM outputs are tri-stated whenever
the controller is disabled (EN = low), the shut-down
ramp has completed or before the soft-start ramp is
initiated.
Figure 19: Output Voltage sensing impedance
INPUT CURRENT SENSING
The IR35204 provides input current sensing to
measure the power drawn by the load from the
source. A precision current sense resistor is
connected in series with the input path as shown in
Figure 21. The voltage across the current sense
resistor is differentially amplified by a current sense
amplifier and fed to I_IN pin of IR35204. An internal
ADC converts the sensed voltage into its digital
equivalent. The I_IN pin input voltage range is 0 to
1.25Vdc.
_
( )=
∗
∗
The IR35204 offers four full-scale ranges for input
current.
1. 0 – 62.5A.
2. 0 – 31.25A.
Figure 18: 3.3V Tri-state Driver Logic Levels
3. 0 – 15.625A.
4. 0 – 7.8125A.
OUTPUT VOLTAGE DIFFERENTIAL SENSING
The IR35204 VSEN and VRTN pins for each loop are
connected to the load sense pins of the output voltage
to provide true differential remote voltage sensing with
high common-mode rejection. Each loop has a high
bandwidth error amplifier that generates the error
voltage between this remote sense voltage and the
26
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
Figure 20 Input Current Sensing
PIN_ALERT
Figure 21: DCR Current Sensing
The IR35204 has a PIN_ALERT# pin to alert the
system when the input power has exceeded a preset
threshold. The pin is an open drain output that is high
until the input power threshold is exceeded at which
point it pulls low. The output stays low until the input
power drops below 90% of the Pin_Alert
threshold. The PIN_ALERT# pin will de-assert
100mS after the input power drops below 90% of the
PIN_ALERT threshold. In an Intel system the
Pin_alert pin is pulled up with a 4.99kohm resistor to
3.3 Vdc. The PIN is filtered by a 2KHz BW filter. The
PIN_ALERT# pin assertion will be belayed by up to
300uS.
OUTPUT CURRENT SENSING
The IR35204 provides per-phase output current
sensing to support accurate Adaptive Voltage
Positioning (AVP), current balancing, and over-current
protection. The differential current sense scheme
supports both lossless inductor DCR and RDS (ON) (or
per-phase series precision resistor) current sensing
techniques.
A current proportional to the inductor current in each
phase is generated and used for per-phase current
balancing. The individual phase current signals are
summed to arrive at the total current.
The phase currents and total current are quantized by
the monitoring ADC and used to implement the
current monitoring and OCP features. The total
current is also summed with the VID DAC output to
implement the AVP function.
The recommended value for Csen is 220nF, with an
NPO type dielectric. To prevent undershooting of the
output voltage during load transients, the Rsen resistor
can be calculated by:
Rsen 
1.05 * L _ out
C sen  DCR
Note: Use thick film resistor (0603) for Rsen.
VCC_Core
For DCR sensing, a suitable resistor-capacitor
network of Rsen and Csen is connected across the
inductor in each phase as shown in Figure 21 below.
The time constant of this RC network is set to equal
the inductor time constant (L/DCR) such that the
voltage across the capacitor Csen is equal to the
voltage across the inductor DCR.
12V
V cc
BOOT
V in
PWM
P WM
I Iphase
+
-
ISEN
IR3555
R1
10K
L_out
S witch
IO UT
IRTN
2.49K
R2
REF IN
Figure 22 RDS (ON) Current Sense
Additionally, the current sense inputs to the IR35204
can also be directly fed the current information from a
PowIRstage having RDS (ON) sensing capability, thereby
27
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
eliminating the need for the R-C sense components,
RSEN and CSEN as shown in Figure 22. The IR3555
has an IOUT gain of 5mV/A. A divider of 5:1 should
be used to match the ISENSE amp input dynamic
range. The recommended values are 10K and 2.49K.
The REFIN pin is offset above 0V by connecting it to
the 1.8V CFILT pin.
IR35204
approximately 30% more current than the other
phases.
CURRENT BALANCING & OFFSET
The IR35204 provides accurate digital phase current
balancing in any phase configuration. Current
balancing equalizes the current across all the phases.
This improves efficiency, prevents hotspots and
reduces the possibility of inductor saturation.
The sensed currents for each phase are converted to
a voltage and are multiplexed into the monitoring
ADC. The digitized currents are low-pass filtered and
passed through a proprietary current balance
algorithm to enable the equalization of the phase
currents as shown in Figure 23.
Figure 24: Phase 1 Current Offset
CURRENT CALIBRATION
For optimizing the current measurement accuracy of a
design, the IR35204 contains a register in MTP, which
can store a user-programmed per phase Current
Offset, to zero out the no-load current reading. Refer
to Table 43 for output current calibration registers.
LOAD LINE
The IR35204 enables the implementation of an
accurate, temperature compensated load line.
Figure 23: Typical Phase Current Balance
(3-phases enabled)
The proprietary high-speed active phase current
balance operates during load transients to eliminate
current imbalance that can result from a load current
oscillating near the switching frequency. The order in
which the phases output PWM pulses is decided
based on an adaptive High Speed Phase Balance
(HSPB) to ensure that the phases remain balanced
during high frequency load transients. Once the VR
returns to steady-state operation, the phases return to
the normal phase firing order.
In addition, the IR35204 allows the user to offset
phase currents to optimize the thermal solution.
Figure 24 shows Phase 1 current gain offset to a
value of 6. This scales the current in phase 1 to have
The nominal load line is set by an external resistor
RCS, as shown in Figure 25. This load line value also
needs to be stored in MTP. The stored values for load
line, scaling and gain provide the scaling factors
required for digital computation of the total current, in
order to determine the true current, OCP threshold,
and output voltage telemetry registers.
For each loop, the sensed current from all the active
phases is summed and applied differentially to a
resistor network across the RSCP and RCSM pins as
shown in Figure 25. This generates a precise
proportional voltage, which is summed with the
sensed output voltage and VID DAC reference to form
the error voltage.
IR35204 supports two types of current sense
techniques.
1. DCR Current Sense.
2. RDS (ON) Current Sense.
28
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
DCR Current Sense
DCR current sense technique measures the voltage
drop across DCR of the inductor as shown in Figure
21. DCR of the inductor has a positive temperature
coefficient of resistance. Hence, to compensate for
increase in DCR with respect to temperature and
thermistor RTh having negative temperature coefficient
of resistance is also part of the network. For proper
load line temperature compensation, the thermistor is
placed near the phase one inductor to accurately
sense the inductor temperature.
where RLL is the desired load line, DCR is DC
resistance of the phase inductor, and R_ISEN is the
internal series resistor = 1000.
2. Select a suitable NTC thermistor, Rth. This is
typically selected to have the lowest thermal
coefficient and tightest tolerance in a standard
available package. A typical NTC used in
these applications is a 10kΩ, 1% tolerance
device. Recommended thermistors are shown
in Table 18.
TABLE 18: 10K 1% NTC THERMISTORS
Murata
NCP18XH103F03RB
Panasonic
ERTJ1VG103FA
TDK
NTCG163JF103F
3. Calculate RCS using the following equation:
RCS 
Figure 25: Load Line & Thermal Compensation for DCR Sense
1
1
1

RCS effective  2  Rseries RTh
Rseries is selected to achieve minimum load line error
over temperature. The IR PowIRCenter GUI provides
a graphical tool that allows the user to easily calculate
the resistor values for minimum error.
The capacitor CCS is defined by the following equation:
CCS 
1
2    RCS effective  f AVP
where fAVP is the user selectable current sense AVP
bandwidth. The recommended bandwidth is typically
in the range of 200kHz to 300kHz.
Figure 26 Load Line for RDS (ON) Current Sense
The resistor RCS is calculated using the following
procedure:
1. Calculate the RCSeffective or the total effective
parallel resistance across the RSCP and
RCSM pins as defined by:
RCS effective  8  R _ ISEN 
29
R LL
DCR
www.irf.com | © 2016 International Rectifier
RDS (ON) Current Sense
IR35204 reads the current value from individual power
stages as shown in Figure 22. The power stage
measures the output current by sensing the voltage
drop across lower side MOSFET. The current sensed
by the power stage is thermally compensated hence
there is no need of an external thermistor for
temperature compensation. Thus, RDS (ON) current
sense reduces the component count required for
loadline measurement as shown in Figure 26.
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
The resistor Rcs for RDS ON current sense is calculated
by using the following procedure.
= 8∗
∗
/(
∗
)
Where IRDS ON Scale = current scale of Power Stage in
V/A
Divider Ratio =
.Refer to Figure 22
The capacitor CCS is defined by the following equation:
CCS 
1
2    RCS  f AVP
where fAVP is the user selectable current sense AVP
bandwidth. The recommended bandwidth is typically
in the range of 200kHz to 300kHz.
Setting a 0mΩ Load Line
The load line is turned off by setting the Loadline
Enable bit low. This is a separate bit from the load line
settings for each loop.
Even though the load line is disabled digitally, the
load-line resistors and scaling registers should be set
such that the load line is at least 3 times the value of
low ohmic DCR inductors (<0.5mΩ) or equal to the
DCR value for high ohmic inductors (>0.5mΩ). For
example, if the inductor(s) DCR is 0.3mΩ, a nominal
0.9 mΩ load line should be set. For accurate current
measurement and OCP threshold with the load line
disabled, the output current gain and scaling registers
must be set to the same value as the load line set with
the external resistor network. With load line disabled,
the thermistor and Ccs capacitor must still be installed
to insure accuracy of the current measurement.
Figure 27 shows a typical 1.05mΩ load line
measurement with minimum and maximum error
ranges. The controller accuracy lies well within
common processor requirements.
30
www.irf.com | © 2016 International Rectifier
Figure 27: Load Line Measurements
The load line range for IR35204 is shown in Table 19.
TABLE 19: LOAD LINE SETTINGS
Loop #1
Loop #2
Minimum
0.0 mΩ
0.0 mΩ
Maximum
6.375 mΩ
12.75 mΩ
Resolution
0.025 mΩ
0.050 mΩ
DIGITAL FEEDBACK LOOP & PWM
The IR35204 uses a digital feedback loop to minimize
the requirement for output decoupling, and to maintain
a tightly regulated output voltage. The error between
the target and the output voltage is digitized and
passed through a low pass filter. This filtered signal is
then passed through an initial single-pole filter stage,
followed by the PID (Proportional Integral Derivative)
compensator, and an additional single-pole filter
stage. The loop compensation parameters Kp
(proportional coefficient), Ki (integral coefficient), and
Kd (derivative coefficient), as well as the low-pass filter
pole locations are user-configurable to optimize the
VR design for the chosen external components.
The adaptive PID control used in IR35204 intelligently
scales the coefficients and the low-pass filters in realtime, to maintain optimum stability, as phases are
added and dropped dynamically in the application.
This auto-scaling feature significantly reduces design
time by virtue of having to design the PID coefficients
design only for one loop combination. (Figure 28).
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
IR35204
widths and the phase relationships of the PWM
pulses. The ATA bypasses the PID control
momentarily during load transients to achieve very
wideband closed loop control and smoothly transitions
back to PID control during steady state load
conditions. Figure 29 illustrates the transient
performance improvement provided by the ATA
showing the clear reduction in undershoot and
overshoot. Figure 30 is a zoomed-in scope capture of
a load step, illustrating the fast reaction time of the
ATA, and how the algorithm changes the pulse phase
relationships. IR35204 provides the option to enable
or disable this feature, using a digitally programmable
bit.
Figure 28: Stability with Phase Add/Drop
Each of the proportional, integral and derivative terms
is a 6-bit value stored in MTP that is decoded by the
IC’s digital core. This allows the designer to set the
converter bandwidth and phase margin to the desired
values.
ATA Enabled
The compensator transfer function is defined as:

 


 

Ki
1
1
( Kp   Kd  s)  



s
 1  s p   1  s p 
1  
2 

where ωp1 and ωp2 are the two configurable poles,
typically positioned to filter noise, and to roll off the
high-frequency gain that the Kd term creates.
The outputs of the compensator and the phase
current balance block are fed into a digital PWM pulse
generator to generate the PWM pulses for the active
phases. The digital PWM generator has a native time
resolution of 1.3ns which is combined with digital
dithering to provide an effective PWM resolution of
163ps. This ensures that there is no limit cycling when
operating at the highest switching frequency.
ATA Disabled
Figure 29: ATA Enable/Disable Comparison
VCORE
ADAPTIVE TRANSIENT ALGORITHM (ATA)
The IR35204 Adaptive Transient Algorithm (ATA) is a
high speed non-linear control technique that allows
compliance with CPU voltage transient load regulation
requirements, with minimum output bulk capacitance
for reduced system cost.
A high-speed digitizer measures both the magnitude
and slope of the error signal to predict the load current
transient. This prediction is used to control the pulse
31
www.irf.com | © 2016 International Rectifier
Figure 30: ATA feature – zoomed-in
In addition, during a load transient overshoot, the ATA
may also be programmed to turn off the low-side
MOSFETS instead of leaving them on. This forces the
load current to flow through the larger FET body
diode, and helps to reduce the overshoot created
during a load release, as showing in Figure 31 below.
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
Diode Emulation:
Disabled
Enabled
The IR35204 provides the VR designer 16 fast slew
rates each of which can be further configured to 4
different slow slew rates by selecting a slew rate
setting as shown . These slew rates can be further
reduced ½, ¼, 1/8, and 1/16
TABLE 21: SLEW RATES
Figure 31: Diode Emulation during a load release
HIGH-SPEED PHASE BALANCE
The IR35204 provides phase balance during high
frequency load oscillations. The balance is provided
through phase skipping. Whenever a set error voltage
threshold and load oscillation frequency threshold are
exceeded for a particular phase, that phase is
skipped, resulting in a lowering of current in the
skipped phase and a corresponding increase in
current in the other phases. Both these thresholds,
listed in Table 20, are user programmable, to provide
flexibility in high-speed phase balance for a wide
variety of systems. In addition, the IR35204 allows the
user to disable HSPB by resetting a bit in MTP.
mV/
µs
Fast
Rate
x 1/2
Factor
x 1/4
Factor
x 1/8
Factor
x 1/16
Factor
10
5.0
2.50
1.25
0.0625
15
7.5
3.75
1.875
0.94
20
10
5.00
2.50
1.25
25
12.5
6.25
3.125
1.56
30
15
7.5
3.75
1.88
35
17.5
8.75
4.375
2.19
40
20
10
5.0
2.5
45
22.5
11.25
5.625
2.81
50
25
12.5
6.25
3.125
55
27.5
13.75
6.875
3.4375
60
30
15
7.5
3.75
65
32.5
16.25
8.125
4.0625
70
35
17.5
8.75
4.375
80
40
20
10
5
85
42.5
21.25
10.625
5.3125
95
47.5
23.75
11.875
5.9375
Note: The maximum DVID rate is limited by the inductor
current available to charge the output capacitors. High
DVID rates may not be possible if the output capacitor and
inductor combination does not allow the output voltage to
change at the selected rate.
TABLE 20: HIGH-SPEED THRESHOLDS
Register
Function
Hspb_enable
Dedicated bit to enable/disable HSPB.
Resetting this bit will result in the HSPB
function not being activated, regardless of the
error voltage or load oscillation frequency
settings.
Hspb_hth
Error Voltage threshold.
Activates HSPB when the threshold is
exceeded.
0mV – 60mV, 4mV resolution
Hspb_fth
Load Oscillation Frequency Threshold.
Activates HSPB when the load oscillation
frequency is above threshold.
0kHz – 703.5kHz, 46.9kHz resolution.
DYNAMIC VID SLEW RATE
32
www.irf.com | © 2016 International Rectifier
DYNAMIC VID COMPENSATION
The IR35204 can compensate for the error produced
by the current feedback in a system with AVP (Active
Voltage Positioning) when the output voltage is
ramping to a higher voltage. An output capacitance
term and an AVP bandwidth term are provided in the
MTP registers to help model the effects of variation in
output voltage during a voltage ramp, due to the
inrush current seen by the output bulk capacitors.
Once properly modeled, the output voltage will follow
the DAC more closely during a positive dynamic VID,
and provide better dynamic VID alert timing, as
®
required by Intel processors. Figure 32 shows the
effects that Dynamic VID Compensation has on the
output voltage and the alert timing.
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
upon the regulator conditions as summarized in Table
23. PS4 can only be commanded with an SVID
command
DVID COMP ON;
3000uF
IVID REGISTER
DVID COMP OFF
IVID efficiency registers are a new addition to the
family of SVID registers of the IMVP8 specification.
When sent an SVID command associated with IVID
registers, IR35204 acknowledges the command and
stores the received information into the IVID registers.
However, IR35204 does not use the information
received in IVID registers for any purpose. Instead, it
uses the user set-up phase shed function to optimize
the VR’s efficiency across the entire operating current
range.
Figure 32: Dynamic VID Compensation
Table 23: Power State Entry/Exit
Command Mode
EFFICIENCY SHAPING
PS1
Entry
In addition to CPU-specified Power States, the
IR35204 features Efficiency Shaping Technology that
enables VR designers to cost-effectively maximize
system efficiency. Efficiency Shaping Technology
consists of Dynamic Phase Control to achieve the
best VR efficiency at a given cost point.
PS1
Exit
PS2
Entry
PS2
Exit
POWER-SAVING STATES
The IR35204 uses Power States to set the powersavings mode. These are summarized in Table 22.
PS3
Entry
PS3
Exit
TABLE 22: POWER STATES
Power
State
Mode
Recommended
Current
PS0
Full Power
Maximum
PS1
Light Load 1-2Φ
<20A
PS2
1Φ Active Discontinuous
(Diode Emulation)
<5A
PS3
1Φ Passive Discontinuous
(Diode Emulation)
<1A
PS4
Output Voltage DVID or
Decay Down to zero
depending upon
configuration in
“ps4_dvid_or_decay”
registor. PWM signals of
all phases are tristated.
PS4
Exit
n/a if Phase Shed enabled
a) Command to PS0
b) DVID to PS0
c) Current limit to PS0
n/a if Phase Shed enabled
a) Command
Current level in 1Φ
a) Command to PS1/0
b) DVID to PS0
c) Current limit to PS0
Fsw > Fsw_desired
to PS0, DVID to PS0,
Current limit to PS0
a) Command
Current level in 1Φ
a) Command to PS2/1/0
b) DVID to PS0
c) Current limit to PS0
Fsw > Fsw_desired
to PS0, DVID to PS0,
Current limit to PS0
a)
Command
n/a
a)
In Single Mode- Any
SVID Clock Toggle.
In Multi Mode – Any
SetVID Command
n/a
b)
.
DYNAMIC PHASE CONTROL (DPC) IN PS0
Near OFF
The Power States may be commanded through
I2C/PMBus, the SVID interface, or the IR35204 can
autonomously step through the Power States based
33
PS4
Entry
Auto Mode
a) Command
www.irf.com | © 2016 International Rectifier
IR35204 optionally supports the ability to
autonomously adjust the number of phases with load
current, thus optimizing efficiency over a wide range
of loads.
The output current level at which a phase is added
can be programmed individually for each phase for
optimum results (Table 24).
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
TABLE 24: DPC THRESHOLDS
Function
Register (2A steps)
Phase1_thresh
2Φ when I > Phase1_thresh
Phase2_delta
3Φ when I > Phase1_thresh +
Phase2_delta
Phase3_delta
4Φ when I > Phase1_thresh +
Phase2_delta+Phase3_delta
VCORE
As shown in Figure 33 (loop one, 3-phase example
shown), the designer can configure the VR to
dynamically add or shed phases as the load current
varies. Both control loops of the IR35204 have the
DPC feature.
yDCM
Efficiency
Programmable
Threshold for
Auto DCM
1Ø
Per -phase
Programmable
Threshold for Auto
Phase Shed
2Ø
3Ø
PWM3
Figure 34: Phase Shed 3Φ1Φ
During a large load step, and based on the error
voltage, the controller instantly goes to the maximum
programmed number of phases. It remains at this
level for a period equivalent to the DPC filter delay,
after which phases get dropped depending on the
load current. The Dynamic Phase Control (DPC)
algorithm is designed to meet customer specifications
even if the VR experiences a large load transient
when operating with a lower number of phases. The
ATA circuitry ensures that the idle phases are
activated with optimum timing during a load step as
shown in Figure 35 and Figure 36 below.
VCORE
Load Current
Figure 33: Dynamic Phase Control Regions
The IR35204 Dynamic Phase Control reduces the
number of phases (Figure 34) based upon monitoring
both the filtered total current and the error voltage
over the DPC filter window. Monitoring the error
voltage insures that the VR does not drop phases
during large load oscillations.
Figure 35: Phase Add 1Φ3Φ
34
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
IR35204
TABLE 25: SWITCHING PERIOD SKEW FACTOR OPTIONS
Vdd
Switching Period Skew Range
Per-Phase
Starting Current
(A)
Fsw to 2 x Fsw
8
Fsw to 2 x Fsw
12
Fsw to 2 x Fsw
16
Fsw to 0.5 x Fsw
8
Fsw to 0.5 x Fsw
12
Idd
16
Fsw to 0.5 x Fsw
Note: Per Phase Current is limited to 62A in normal mode,
124A in doubler mode.
Figure 36: Zoomed-out view of Phase Shed/Add
Current limit and current balancing circuits remain active
during ATA events to prevent inductor saturation and
maintain even distribution of current across the active
phases.
Using the above feature, the switching frequency can be
skewed based on the different register settings and perphase currents – the switching frequency skew factor versus
per-phase currents have been plotted in Figure 38 below for
3 of the register settings for reference.
The add/drop points for each phase can be set in 2A
increments from 0 to 62A per phase, with a fixed 4A
hysteresis. This results in a uniform per-phase current
density as the load increases or decreases.
Having DPC enabled optimizes the number of phases used
in real time, resulting in significant light and medium-load
efficiency improvements, as shown in Figure 37.
Figure 38: Normalized Switching Frequency
DISCONTINUOUS MODE OPERATION - PS2, PS3
Figure 37: Light Load Efficiency Improvement with DPC
Under very light loads, the VR efficiency is dominated by
MOSFET switching losses. In PS2 mode, the IR35204
operates as a constant on-time controller where the user
sets the desired peak-to-peak ripple by programming an
error threshold and an on-time duration (Table 26). PS3
operation is identical to PS2, with the additional ability to
disable the internal current sense amplifiers within the
controller for further reduction in power consumption.
VARIABLE FREQUENCY WITH LOAD ON LOOP1
In addition, the controller can be made to operate at a high
frequency when only a few phases are running, and lower
the frequency as more phases are added. This skew feature
is based on monitoring the per-phase current. The different
skews of the switching frequency available are:
35
www.irf.com | © 2016 International Rectifier
TABLE 26: PS2/PS3 MODE CONSTANT ON-TIME CONTROL
MTP Register
Function
ni_thresh
Sets the current level below which
PS2/PS3 is entered.
de_thresh
Sets the error threshold to start a pulse
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
during diode emulation, in 3mV resolution.
Sets the duration of the ON time pulse in
40ns steps during diode emulation.
de_pw
off_time_adj
Reduces the calculated low-side FET
ON time during diode emulation in 60ns
steps. Useful for compensating for DrMOS
or other drivers’ tri-state delay for better
zero-crossing prediction.
In PS2 mode (Active Diode Emulation Mode), the internal
circuitry estimates when the inductor current declines to
zero on a cycle-by-cycle basis, and shuts off the low-side
MOSFET at an appropriate time in each cycle (Figure 39).
This effectively lowers the switching frequency, resulting in
lowered switching losses and improved efficiency.
Industry standard tri-state drivers typically have delays when
entering tri-state, typically 150ns to 300ns, which allows
negative current to build up, causing switch node ringing
and reducing efficiency.
The off_time_adj variable allows for compensation of the tristate delay by reducing the low-side FET on-time by an
equivalent amount.
The controller does not shutdown the circuitry for lowest
power consumption.
PS4 wake up can be set to wake on any SVID clock
or alternatively on any SVID Set_VID or SetPS0/1/2/3
command.
PS4 REGISTER SUPPORT
IR35204 controller supports SVID register “PS4 Exit
Latency” (2B). This register holds the encoded value for PS4
exit latency calculated as
(
)=
Where x =bits[3:0], y = bits[7:4]
16
∗2
FAULTS & PROTECTION
The comprehensive fault coverage of the IR35204 protects
the VR against a variety of fault conditions. Faults can be
configured and monitored through the IR PowIRCenter GUI.
There are two types of fault monitoring registers. In addition
to real-time fault registers, there are “sticky” fault registers
that can only be cleared with an I2C command or 3.3V
power cycle. These will indicate if any fault has occurred
since the last power cycle, even if the fault has cleared itself
and the VR has resumed normal operation.Table 27 lists the
available faults.
TABLE 27: STICKY & NON-STICKY FAULTS
VOUT
Zero-crossing prediction
at the correct time
IΦ1
Register Type
Faults
Sticky
OTP, OCP, OVP, UVP,
VIN UVLO, 3.3V UVLO,
phase-fault, slow-OCP
Non-Sticky
Programmed
on-time
Calculated low-side
FET on-time
PWM(Φ1)
Output Over-voltage Protection (OVP)
Figure 39: PS2 Active Diode Emulation Mode
If the output voltage exceeds a user-programmable
threshold (Table 32) above the VID set-point, the IR35204
detects an output over-voltage fault and latches ON the lowside MOSFETS to limit the output voltage rise.
PS4 MODE
The IR35204 controller supports the PS4 command but
does not reduce controller power consumption .
When a valid PS4 command is received by the controller,
the IR35204 does the following:

Acknowledge the command.

Output voltage is DVID or Decay down to 0 Vdc
depending upon the configuration in
“ps4_dvid_or_decay” register.

PWM signals of all phases are tristated.
36
www.irf.com | © 2016 International Rectifier
TABLE 28: OVP ACTION
OVP Action
Low-side MOSFET latched on
Low-side MOSFET on until
Output<0.248V
Per Table 28 above, the low-side MOSFETs may be
configured to either latch ON indefinitely (Figure 40) or stay
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
ON until the output voltage falls below the release threshold
(Figure 41), in case of an over-voltage condition. This
release mode reduces the undershoot of the output voltage
during recovery from an OVP condition. If the output voltage
rises above the OVP threshold during recovery, the low side
MOSFET’s will again be turned on until Vout drops below
the release threshold level. Note that OVP is disabled during
a DVID-down event to prevent false triggering.
During soft-start, OVP is triggered at a user-selectable level
from one of the thresholds listed in Table 29 below.
Figure 41: OVP - MOSFET released when output<0.3V
TABLE 29: OVP THRESHOLDS DURING START-UP
Value
Threshold
0
2.5V
1
1.2V
2
1.275V
3
1.35V
The IR35204 also provides the option to allow OVP to
remain active when the device is disabled, in order to
prevent system leakage from causing over-voltage on the
output (Table 30).
Note: OVP functionality is only available when both the
controller and drivers or power stages have Vcc power.
TABLE 30: OVP OPTIONS
OVP_when-disabled
setting
When active
On
IC disabled & IC enabled
Off
IC enabled
Output Under-voltage Protection (UVP)
The IR35204 detects an output under-voltage condition if
the sensed voltage at the CPU is below the userprogrammable UVP threshold (Table 32) or a fixed 248mV
(if the ADC detection is used instead of the comparator), as
shown inTable 31.
TABLE 31: UVP THRESHOLD OPTIONS
Use the common comparator
Use the ADC
The user also has the option to choose if the threshold
needs to factor in the load line or not. Upon detecting an
output under-voltage condition, the IR35204 responds in the
same manner as the OCP, according to the setting selected
inTable 33.
TABLE 32: OVP & UVP THRESHOLDS
Value
Threshold
0
50mV
1
100mV
2
150mV
3
200mV
4
250mV
5
300mV
6
350mV
7
400mV
Over-current Protection (OCP)
Figure 40: OVP - MOSFET latched on
37
www.irf.com | © 2016 International Rectifier
The IR35204 provides a programmable output overcurrent protection threshold of up to 62A per phase.
This would translate to an overall maximum system
OCP threshold of 62A times the number of phases.
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
The controller action during an OCP event can be
configured as shown in TABLE 33. Note that the OCP
protection is disabled during start up and during VID
transitions. Also, the threshold scales by a factor of 2x
in the doubler mode and 4x in the quad mode.
TABLE 33: OCP & UVP MODE SELECTION
OCP/UVP Behavior Mode
devices need to be placed close to the thermal hot
spot for optimal performance. The thresholds are
programmable in 1°C increments within the range
shown in Table 35. If the measured temperature
exceeds the OTP threshold, the IR35204 will latch off
the VR, requiring a system power recycle or an
ENABLE recycle to resume operation.
TABLE 35: VR_HOT & OTP
Per phase OCP Threshold (0 to 62A)
Shutdown immediately
(cycle power or enable to restart)
Hiccup 2X before Shutdown
Hiccup indefinitely
Slow Current Limit
Function
VR_HOT threshold (64°C to 127°C)
OTP threshold (VR_HOT + 0°C to 32°C) max 135°C
MAX 158C with IR3555 temp sense
NTC Temperature Sense
In addition to the (fast) OCP, a Slow Current Limit can
be programmed to monitor and protect against the
thermal effects of the average current over time. This
allows the system designer to operate close to the
TDP level of the system. The slow current limit
bandwidth is set by the telemetry bandwidth to one of
the following options:
The IR35204 includes a pre-programmed look-up
table that is optimized for the recommended NTC
options shown in Table 36. The NTC network is
connected to the TSEN pin as shown in Figure 42.
A 0.01µF capacitor is recommended for filtering when
used with the NTC sense network.
TABLE 34: TELEMETRY BANDWIDTH SETTING OPTIONS
TABLE 36: NTC TEMPERATURE SENSE RANGE
Value
Bandwidth (Hz)
0
0.69
NTC
Value
Rparallel
1
1.39
Murata NCP15WB473F03RC or
Panasonic ERT-J0EP473J
47KΩ
13KΩ
2
2.78
3
5.55
4
11.1
5
22.2
6
44.6
7
89.5
When the slow OCP threshold is exceeded, the VR
will shut down based upon the OCP mode
programmed in the MTP.
Note that the slow OCP protection is disabled during
start up and during VID transitions.
VR_HOT and Over Temperature Protection (OTP)
The IR35204 provides a temperature measurement
capability at the TSEN pin that is used for over
temperature protection, VR_HOT flag and
temperature monitoring. The temperature is measured
with either an NTC network or by monitoring IR
PowIRstage temperature reporting outputs. Sense
38
www.irf.com | © 2016 International Rectifier
Figure 42: Temperature Sense NTC Network
IR Power Stage Temperature Sense
The controller is designed to interface to the IR3555
power stage to receive temperature and fault
information from the IR3555 power stage. The power
stage temperature output is scaled to 8mV/C and a
1:1.64 divider is required to scale this down to the
4.88mV/C gain of the controller input as shown in
Figure 43. Fault communication from the IR3555 is a
3.3Vdc high. The 3.3Vdc high from the power stage
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
indicates either 1) a power stage phase fault, 2) an
over temperature, 3) a persistent overcurrent or 4) an
over voltage condition. The controller will shut down
and assert the CAT_FLT pin (high) upon receiving the
power stage fault.
To controller
TSEN
6.49KOhm
TOUT
From IR3555 100pF
10KOhm
Figure 43: Temperature Sense IR Power Stage Network
7
Input Over-voltage Protection
The IR35204 offers protection against input supply
over-voltage. When enabled (Table 39), the VINSEN
pin is compared to a fixed threshold of 14.5V with a
14:1 divider, and shuts down the IC if the threshold is
exceeded.
TABLE 39: INPUT OVER-VOLTAGE OPTIONS
disabled
VR_HOT_ICRIT Pin Functionality Options
The functionality of the VR_HOT_ICRIT pin can be set
to assert when levels of Temp_max, Icc_max, and/or
OCP levels are exceeded. Table 37 shows the
multiple configurations of the VR_HOT_ICRIT pin.
TABLE 37: VR_HOT_ICRIT PIN OPTIONS
Temp_max Only
Temp_max or Icc_max
Temp_max or OCP
Icc_max Only
Icritical Flag
The IR35204 VR_HOT_ICRIT pin can optionally be
programmed to assert when a user programmable
output current level is exceeded. The assertion is not
a fault, and the VR continues to regulate. I_CRITICAL
monitors a long term averaged output current, which
is a useful indicator of average operating current and
thermal condition. The user can select between the
I_CRITICAL filters bandwidths shown in Table 38.
TABLE 38: I_CRITICAL OVER-CURRENT OPTIONS
39
Value
Bandwidth (Hz)
0
0.69
1
1.39
2
2.78
3
5.55
4
11.1
5
22.2
6
44.6
www.irf.com | © 2016 International Rectifier
89.5
I_CRITICAL has a 5% hysteresis level and the
VR_HOT_ICRIT pin will de-assert when the average
output current level drops below 95% of the
programmed current level threshold.
enabled
Phase Faults
The IR35204 can detect and declare a phase fault
when the current in one or more phases is too high or
too low. It detects the fault when the duty cycle of a
particular phase is 5% higher or lower than the
average duty cycle of all the phases. This feature
helps detect severe imbalances in the phase currents,
an unpowered or damaged MOSFET driver, or a
phase that is disconnected from Vin. The phase fault
feature can be enabled or disabled through an MTP
bit. When a phase fault occurs, the controller shuts
down the loop where the fault occurred, and sets
register bits to display which phase had the fault and
whether it faulted high or low. The phase fault
registers are cleared via a register bit and the VR will
restart once ENABLE or Vcc is cycled.
TABLE 40: PHASE FAULT REGISTERS
Register
Function
pi_fault_en
Enables phase current fault
shutdown.
clear_phase_faults
Clears all phase faults for each loop.
pi_fault
Indicates which phase has a phase
current fault. 0 – phase1, 1 – phase2,
2 – phase3, 3 – phase4…7-phase 8
max_cond
Indicates one or more phase currents
are too high.
min_cond
Indicates one or more phase currents
are too low.
I2C/PMBUS COMMUNICATION
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
The IR35204 simultaneously supports I2C and PMBus
through the use of exclusive addressing. This means
that a motherboard PMBus master may communicate
with as many as 127 IR35204-based VRs. Optionally,
a resistor offset can be enabled as shown in Table 41
(note that a 0.01µF capacitor is required across the
resistor per Figure 44), with the offsets shown in Table
42.
As an example, setting a base 7-bit I2C address of
28h with a resistor offset of +15 sets the 7-bit I2C
address to 37h. Similarly setting a base 7-bit PMBus
address of 40h with a resistor offset of +15 sets the 7bit PMBus address to 4Fh.
The IR35204 can also set the I2C address independently from the PMBus address. By using a 7-bit
address the user can configure the device to any one
of 127 different I2C addresses.
Once the address of the IR35204 is set, it is locked to
protect it from being overridden.
For default programmed devices, the I2C/PMBus
address can be temporarily forced to address 0Ah for
I2C and 0Dh for PMBus by setting EN=VR_HOT=low.
TABLE 41: I2C OFFSET OPTIONS
Enable_I2C
Addr_Offset MTP
bit
0
1
I2C Address
Offset
6.98kΩ
+10
7.87kΩ
+11
8.87kΩ
+12
10.00kΩ
+13
11.00kΩ
+14
12.10kΩ
+15
Note: Extends the range of PMBus
addresses.
Figure 44: ADDR pin components
REAL-TIME I2C MONITORING FUNCTIONS
IR35204 provides real-time accurate measurement of
input voltage, input current, output voltage, output
current and temperature over the I2C interface.
Output voltage is calculated based upon the VID
setting and load line, and the result is reported
through the I2C.
Accuracy Optimization Registers
I2C Address Offset
disabled
enabled
TABLE 42: ADDR RESISTOR OFFSET
ADDR Resistor
I2C Address
Offset
0.845kΩ
+0
1.30kΩ
+1
1.78kΩ
+2
2.32kΩ
+3
2.87kΩ
+4
3.48kΩ
+5
4.12kΩ
+6
4.75kΩ
+7
5.49kΩ
+8
6.19kΩ
+9
40
ADDR Resistor
www.irf.com | © 2016 International Rectifier
The IR35204 provides excellent factory-trimmed chip
accuracy. In addition, the designer has calibration
capability that can be used to optimize reporting
accuracy for a given design, with minimum component
changes. Once a design is optimized, the IR35204
provides excellent repeatability from board to board.
The IR35204 also provides capability for individual
board calibration and programming in production for
best accuracy. Table 43 shows the MTP registers
used to fine tune the accuracy of the reported
measurements. Figure 45 to Figure 47 show the
typical accuracy of the output current, input voltage
and output voltage measurements using the IR35204.
TABLE 43: ACCURACY OPTIMIZATION REGISTERS
NVM
Register
IIN Fixed
Offset
Function
Offsets the input current in 1/32A
steps.
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
IOUT
Current
Offset
Offsets the output current from
-2A to +1.875A per phase in 0.125A
steps
Vout Offset
Offsets the output voltage +40mV to
-35mV in 5mV steps (Intel® VR12
mode), or +80mV to -70mV in 10mV
steps (Intel® VR12.5 mode).
1.050
1.00%
Vout (DMM)
1.025
0.75%
Vout (I2C)
0.50%
Vout error (2nd axis)
0.975
0.25%
0.950
0.00%
0.925
-0.25%
0.900
-0.50%
0.875
-0.75%
0.850
Error
1.000
Vout (V)
IIN Per
Phase Offset
Offsets the input current dependent
upon the number of active phases
in 1/128A steps e.g. the drive
current for the MOSFET’s. This
current increases every time a new
phase is added.
-1.00%
0
20
40
60
80
100
E-Load (A)
Temperature
Offset
Offsets the temperature +31°C to 32°C in 1°C steps to compensate
for offset between the hottest
component and the NTC sensing
location.
Duty Cycle
Adjust
Adjusts the input current calculation
to compensate for a non-ideal
driver.
I2C SECURITY
20%
15%
Iout Error
10%
CPU spec with 7% inductors
The IR35204 provides robust and flexible security
options to meet a wide variety of customer
applications. A combination of hardware pin and
software passwords prevent accidental overwrites,
discourages hackers, and secures custom
configurations and operating data. The Read and
Write Security can be in set in MTP (Table 44 and
Table 45) with the protection methods shown in Table
46.
TABLE 44: READ SECURITY
5%
Error
Figure 47: I2C Output Voltage Measurements
0%
0
10
20
30
40
50
60
70
80
90
No Protection
100
-5%
Configuration Registers Only
-10%
Protect All Registers But Telemetry
-15%
Protect All
-20%
E-Load (A)
Figure 45: I2C IOUT Error using 10% DCR Inductors
No Protection
1.0%
12.3
TABLE 45: WRITE SECURITY
Configuration Registers Only
12.2
0.5%
Protect All
0.0%
12
Error
Vin (V)
12.1
Vin (DMM)
11.9
-0.5%
Vin (I2C)
11.8
Vin error (2nd axis)
TABLE 46: READ OR WRITE UNLOCK OPTIONS
Password Only
-1.0%
11.7
0
20
40
60
80
Pin Only
100
E-Load (A)
Pin & Password
Figure 46: I2C Input Voltage Measurements
Lock Forever
Password Protection
The system designer can set any 16-bit password
(other than 00h). This password is stored in MTP. To
unlock, a user must write the correct password into
41
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
the “Password Try” register, which is a volatile
read/write register. After four incorrect tries, the IC will
lock up to prevent unauthorized access.
TABLE 50: MIN/MAX REGISTER SETTINGS
Pointer
Value
Reading
0
loop_1_current_min
1
loop_1_current_max
2
loop_2_current_min
3
loop_2_current_max
4
loop_1_input
_current_min
5
loop_1_input
_current_max
6
loop_2_input
_current_min
# now write new password into MTP
Write new password high Byte to high Byte Password register
7
loop_2_input
_current_max
# password has changed! Must unlock to change the low byte
Write new password high Byte to R/W high Byte Try register
Write new password low Byte to low Byte Password register
8
loop_1_output_
voltage_min
9
loop_1_output_
voltage_max
10
loop_2_output_
voltage_min
11
loop_2_output_
voltage_max
12
input_voltage_min
13
input_voltage_max
14
temp1_min
15
temp1_max
16
temp2_min
17
temp2_max
TABLE 47: PASSWORD REGISTERS
Register
Length
Location
Password
16 bit (2 bytes)
MTP
Try
16 bit (2 bytes)
R/W
The following pseudo-code illustrates how to change
a password:
# first unlock the IC
Write old password high Byte to R/W high Byte Try register
Write old password low Byte to R/W low Byte Try register
# password change complete, status is locked
# Need to write new low byte to Try register to unlock
Pin Protection
The ADDR/PROTECT pin is a dual function pin.
When the IC is enabled, the resistor value is latched
and stored for use in the I2C address offset function.
Thereafter, the pin acts entirely as a PROTECT pin.
If enabled, the PROTECT pin must be driven high to
unlock and low to lock. If the resistor address offset
function is being used, care must be taken to allow the
IC to read the resistor value before driving the pin high
or low to set the security state. Failure to follow this
precaution may result in an erroneous address offset
value being latched in. The user should at least wait
until the completion of the auto-trim time t4 in Figure 6.
Min/Max Registers
Min/Max registers for IOUT, IIN, VOUT, VIN, and
TEMPERATURE are available. The data is read by
setting a pointer and reading the value from a register
that contains the minimum and maximum data. These
registers store high and low values from startup or the
last read, whichever was the latest to occur. The
registers are automatically cleared when the data is
read back from the controller
The minmax_sel[4:0] register is the pointer used to
select the appropriate signal and the minmax_val[7:0]
register will show the min or max value of what has
been selected. The list of available min/max values,
bandwidth, and resolutions are shown in Table 50.
42
www.irf.com | © 2016 International Rectifier
Signal
bandwidth
62 KHz/ 3.93
KHz (based
on minmax
_output_i_bw)
Resolution
of reading
value
2A
0.5A
0.125A
102Hz
0.0625A
Telemetry_bw
0.0625V
760Hz
0.125V
Telemetry_bw
Telemetry_bw
1C
1C
1C
1C
AMD SVI2 MODE
When the power-on sequence is initiated, both rails
will ramp to the configured Vboot voltage and assert
the PWRGD on each loop. The soft-start occurs at the
½ or ¼ multiplier slew rate as selected in Table 51.
TABLE 51: SLEW RATES
mV/µs
FAST rate
½ Multiplier
¼ Multiplier
10
5.0
2.50
15
7.5
3.75
20
10
5.00
25
12.5
6.25
The boot voltage is decoded from the SVC and SVD
levels when the EN pin is asserted high as shown in
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
Table 52. This value is latched and will be re-used in
the event of a soft reset (de-assertion and re-assertion
of PwrOK).
Note: VCC and VDDIO must be stable for a
minimum 5ms before the IC is enabled to ensure
that the Boot voltage is decoded from the SVC,
SVD pins correctly.
TABLE 52: AMD SVI BOOT TABLE
Boot Voltage
SVC
SVD
1.1V
0
0
1.0V
0
1
0.9V
1
0
0.8V
1
1
Alternatively, the AMD boot voltage can be set by an
MTP register instead of decoding the SVC, SVD pins
as shown in Table 53. Boot values are shown in Table
54.
TABLE 53: AMD BOOT OPTIONS
MTP Boot Register
Boot Location
Bit[7] = low
Decode from SVC, SVD pins per Table 52
Bit[7] = high
Use MTP boot register bits [6:0]
IR35204
The IR35204 implements a fully compliant AMD SVI2
Serial VID interface (SVI). SVI2 is a three-wire
interface between a SVI2 compliant processor and a
VR. It consists of clock, data, and telemetry/alert
signals. The processor will send a data packet with
the clock (SVC) and data (SVD) lines. This packet has
SVI commands to change VID, go to a low power
state, enable and configure telemetry, change load
line slope and change VID offset. The VR, when
configured to do so, will send telemetry to the
processor. The telemetry data consists of voltage
only, or voltage and current of each output rail (VDD,
VDDNB). The telemetry line (SVT) is also used as an
alert signal (VOTF complete) to alert the processor
when a positive going VID change in complete, or an
offset or load line scale change has occurred.
VID Change
The IR35204 accepts an 8-bit VID within the SVD
packet and will change the output voltage at the FAST
rate specified in Table 51 of one or both of the loops
based on the VID in Table 54. This is a VID-on-the-flyrequest (VOTF Request).
PWROK De-assertion
The IR35204 responds to SVI commands on the SVI
bus interface when PWROK is high. In the event that
PWROK is de-asserted the controller resets the SVI
state machine, drives the SVT pin high and returns to
the Boot voltage, initial load line slope and offset.
PWROK
Figure 49: PWROK De-assertion
SVI2 Interface
43
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
TABLE 54: SVI2 VID TABLE
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
0
1.55000
32
1.23750
64
0.92500
96
0.61250
C8
0.30000
1
1.54375
33
1.23125
65
0.91875
97
0.60625
C9
0.29375
2
1.53750
34
1.22500
66
0.91250
98
0.60000
CA
0.28750
3
1.53125
35
1.21875
67
0.90625
99
0.59375
CB
0.28125
4
1.52500
36
1.21250
68
0.90000
9A
0.58750
CC
0.27500
5
1.51875
37
1.20625
69
0.89375
9B
0.58125
CD
0.26875
6
1.51250
38
1.20000
6A
0.88750
9C
0.57500
CE
0.26250
7
1.50625
39
1.19375
6B
0.88125
9D
0.56875
CF
0.25625
8
1.50000
3A
1.18750
6C
0.87500
9E
0.56250
D0
0.25000
9
1.49375
3B
1.18125
6D
0.86875
9F
0.55625
D1
0.24375
A
1.48750
3C
1.17500
6E
0.86250
A0
0.55000
D2
0.23750
B
1.48125
3D
1.16875
6F
0.85625
A1
0.54375
D3
0.23125
C
1.47500
3E
1.16250
70
0.85000
A2
0.53750
D4
0.22500
D
1.46875
3F
1.15625
71
0.84375
A3
0.53125
D5
0.21875
E
1.46250
40
1.15000
72
0.83750
A4
0.52500
D6
0.21250
F
1.45625
41
1.14375
73
0.83125
A5
0.51875
D7
0.20625
10
1.45000
42
1.13750
74
0.82500
A6
0.51250
D8
0.20000
11
1.44375
43
1.13125
75
0.81875
A7
0.50625
D9
0.19375
12
1.43750
44
1.12500
76
0.81250
A8
0.50000
DA
0.18750
13
1.43125
45
1.11875
77
0.80625
A9
0.49375
DB
0.18125
14
1.42500
46
1.11250
78
0.80000
AA
0.48750
DC
0.17500
15
1.41875
47
1.10625
79
0.79375
AB
0.48125
DD
0.16875
16
1.41250
48
1.10000
7A
0.78750
AC
0.47500
DE
0.16250
17
1.40625
49
1.09375
7B
0.78125
AD
0.46875
DF
0.15625
18
1.40000
4A
1.08750
7C
0.77500
AE
0.46250
E0
0.15000
19
1.39375
4B
1.08125
7D
0.76875
AF
0.45625
E1
0.14375
1A
1.38750
4C
1.07500
7E
0.76250
B0
0.45000
E2
0.13750
1B
1.38125
4D
1.06875
7F
0.75625
B1
0.44375
E3
0.13125
1C
1.37500
4E
1.06250
80
0.75000
B2
0.43750
E4
0.12500
1D
1.36875
4F
1.05625
81
0.74375
B3
0.43125
E5
0.11875
1E
1.36250
50
1.05000
82
0.73750
B4
0.42500
E6
0.11250
1F
1.35625
51
1.04375
83
0.73125
B5
0.41875
E7
0.10625
20
1.35000
52
1.03750
84
0.72500
B6
0.41250
E8
0.10000
21
1.34375
53
1.03125
85
0.71875
B7
0.40625
E9
0.09375
22
1.33750
54
1.02500
86
0.71250
B8
0.40000
EA
0.08750
23
1.33125
55
1.01875
87
0.70625
B9
0.39375
EB
0.08125
24
1.32500
56
1.01250
88
0.70000
BA
0.38750
EC
0.07500
25
1.31875
57
1.00625
89
0.69375
BB
0.38125
ED
0.06875
44
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
VID
(Hex)
Voltage
(V)
26
1.31250
58
1.00000
8A
0.68750
BC
0.37500
EE
0.06250
27
1.30625
59
0.99375
8B
0.68125
BD
0.36875
EF
0.05625
28
1.30000
5A
0.98750
8C
0.67500
BE
0.36250
F0
0.05000
29
1.29375
5B
0.98125
8D
0.66875
BF
0.35625
F1
0.04375
2A
1.28750
5C
0.97500
8E
0.66250
C0
0.35000
F2
0.03750
2B
1.28125
5D
0.96875
8F
0.65625
C1
0.34375
F3
0.03125
2C
1.27500
5E
0.96250
90
0.65000
C2
0.33750
F4
0.02500
2D
1.26875
5F
0.95625
91
0.64375
C3
0.33125
F5
0.01875
2E
1.26250
60
0.95000
92
0.63750
C4
0.32500
F6
0.01250
2F
1.25625
61
0.94375
93
0.63125
C5
0.31875
F7
0.00625
30
1.25000
62
0.93750
94
0.62500
C6
0.31250
F6-FF
OFF
31
1.24375
63
0.93125
95
0.61875
C7
0.30625
45
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
PSI[x]_L and TFN
Load Line Slope Trim
PSI0_L is Power State Indicator Level 0. When this bit
is asserted the IR35204 will drop to 1 phase
depending on configuration. This will only occur if the
output current is low enough (typically <20A) to enter
PSI0, else the VR will remain in full phase operation.
PSI1_L is Power State Indicator Level 1. When this bit
is asserted along with the PSI0_L bit, the IR35204 will
enter diode emulation mode. This will only occur if the
output current is low enough (typically <5A) to enter
PSI1, else the VR will enter PSI0_L mode of
operation.
TFN is an active high signal that allows the processor
to control the telemetry functionality of the VR. If
TFN=1, then the VR telemetry will be configured per
Table 55.
The IR35204 has the ability for the processor to
change the load line slope of each loop independently
through the SVI2 bus while ENABLE and PWROK are
asserted via the serial VID interface. The slope
change applies to initial load line slope as set by the
external RCSP/RCSM resistor network. The load line
slope can be disabled or adjusted by -40%, -20%, 0%,
+20%, +40%, +60%, or +80%.
Offset Trim
The IR35204 has the ability for the processor to
change the offset of each loop independently while
ENABLE and PWROK are asserted via the serial VID
interface. The offset can be left unchanged, disabled,
or changed +25mV or -25mV.
Ispike/Dual OCP Support
TABLE 55: TFN TRUTH TABLE
VDD, VDDNB Domain
Selector bit
Meaning
0, 0
Telemetry is in voltage only mode.
0, 1
Telemetry is in voltage
& current mode.
1, 0
Telemetry is disabled.
1, 1
Reserved.
SVT Telemetry
The IR35204 has the ability to sample and report
voltage and current for the VDD and VDDNB
domains. The IR35204 reports this telemetry serially
over the SVT wire which is clocked by the processor
driven SVC. If in voltage-only telemetry mode then the
sampled voltage for VDD and VDDNB are sent
together in every SVT telemetry packet at a rate of
20kHz. If in voltage and current mode then the
sampled voltage and current for VDD is sent out in
one SVT telemetry packet followed by the sampled
voltage and current for VDDNB in the next SVT
telemetry packet at a rate of 40kHz. The voltage and
current are moving averages based on the filters and
update rates specified in the Electrical Specification
Table. The voltage is reported as a function of the Set
VID minus Iout times the Load Line Resistance. The
current is reported as a percentage of the Icc_max
register, where a value of FFh represents 100% and
00h represents 0% of the Icc_max setting. Resolution
of the current reporting is 0.39% (1/256).
46
IR35204
www.irf.com | © 2016 International Rectifier
The IR35204 has two current limit thresholds. One
threshold is for short duration current spikes (Fast
OCP). When this threshold, typically a percentage
above the peak processor current, is exceeded, the
VR quickly shuts down. The other threshold, typically
a percentage above the thermal design current (TDC),
is heavily filtered (Slow OCP) and shuts down the VR
when the average current exceeds it. To meet AMD
specifications, exceeding both thresholds will assert
the OCP_L (VR_HOT) pin and delay the over-current
shut down by 10usec for FAST threshold and 20usec
for the SLOW threshold, typically. Figure 50 and
Figure 51 show the delay action of the OCP shutdown
with the OCP_L (VR_HOT) and PWRGD pins.
Over-current
detected
Vdd
Idd
OCP Delay
(fast)
OCP_L
PG
VR shuts
down
Figure 50: OCP_L (VR_HOT) assertion with
OCP_spike (Fast) threshold. OCP delay action (11usec)
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
IR35204
Over-current
detected
Vdd
Idd
OCP Delay
(slow)
OCP_L
PG
VR shuts
down
Figure 51: OCP_L (VR_HOT) assertion with
OCP_TDC (Slow) threshold. OCP delay action (22usec)
Thermal Based Protection
The IR35204 can also assert the PROC_HOT_L
(VR_HOT) pin when the temperature of the VR
exceeds a configurable temp_max threshold (typically
100⁰ C). If the temperature continues to rise and
exceeds a second configurable threshold
(OTP_thresh) then the VR will shut down and latch
off. The VR can only be restarted if ENABLE or VCC
is cycled.
AMD SVI Address Programming
By default, loop 1 is addressed as the VDD rail and
loop 2 is addressed as the VDDNB rail which is
sufficient for most applications. The IR35204 however,
can also be configured with a single bit change to
swap this addressing scheme so that loop 1 can be
addressed as the VDDNB rail and loop 2 can be
addressed as the VDD rail. This is for application
where the VDDNB requires more than one phase and
VDD only requires one.
47
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
I2C PROTOCOLS
All registers may be accessed using either I2C or PMBus protocols. I2C allows the use of a simple format
whereas PMBus provides error checking capability. Figure 52 shows the I2C format employed by the IR35204.
Figure 52: I2C Format
PMBUS PROTOCOLS
To access IR’s configuration and monitoring registers, 4 different protocols are required:

the PMBus Send Byte protocol with/without PEC (for CLEAR_FAULTS only)

the PMBus Read/Write Byte/Word protocol with/without PEC (for status and monitoring)

the PMBus Block Read and Block Write protocols with Byte Count = 1 and Byte Count = 2

the PMBus Block Read Process call (for accessing Configuration Registers)
An explanation of which command codes and protocols are required to access them is given in Table 6.
In addition, the IR35204 supports:

Alert Response Address (ARA)

Bus timeout (30ms)

Group Command for writing to many VRs within one command
48
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
IR35204
LEGEND:
Figure 53: PMBus Send Byte
Figure 54: PMBus Write Byte/Word
Figure 55: PMBus Read Byte/Word
49
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
Figure 56: PMBus Block Read with Byte Count=1
Figure 57: PMBus Block Read with Byte Count=2
Figure 58: PMBus Block Write with Byte Count=1
Figure 59: PMBus Block Write with Byte Count=2
Figure 60: MFR_WRITE_REG
S
PMBus
Address
Sr
PMBus
Address
W
R
Command
D0h
A
A
Data Byte
Register
Address
A
Address+1
Data Byte
A*
A
A
...
N
PEC*
P
Figure 61: MFR_READ_REG
S
PMBus
Address
PMBus
Sr Address
W
A
R
A
Command
1
A
A
1
Data Byte
A
Command
A*
PEC*
A
N
...
P
Figure 62: Block Read Process Call
50
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
Figure 63: Group Command
TABLE 56: PMBUS COMMANDS
COMMAND
PMBUS
PROTOCOL
COMMAND
CODE
OPERATION
Read/Write Byte
01h
Enables or disables the output and controls margining.
Ignores OVP on Margin High, UVP on Margin Low.
ON_OFF_CONFIG
Read/Write Byte
02h
Configures the combination of CONTROL pin and
OPERATION command needed to turn the unit on and off.
CLEAR FAULTS
Send Byte
03h
Clear contents of Fault registers
WRITE_PROTECT
Read/Write Byte
10h
Provides protection from accidental changes
RESTORE_DEFAULT_ALL
Send Byte
12h
Reloads the OTP
CAPABILITY
Read Byte
19h
Returns 1010xxxx to indicate Packet Error Checking is
supported and Maximum bus speed is 400kHz
SMBALERT_MASK
Block Write/ Block
Read Process Call
1Bh
Set to prevent warning or fault conditions from asserting the
SMBALERT# signal. Write command code for STATUS
register to be masked in the low byte, the bit to be masked
in the High byte.
VOUT_MODE
Read/Write Byte
20h
Sets the format for VOUT related commands.
Linear mode, -8 and -9 exponents supported.
VOUT_COMMAND
Read/Write Word
21h
Sets the voltage to which the device should set the output.
Format according to VOUT_MODE.
VOUT_TRIM
Read/Write Word
22h
Applies a fixed offset to the output voltage command value.
Format according to VOUT_MODE.
VOUT_MAX
Read/Write Word
24h
Sets an upper limit on the output voltage the unit can
command. Format according to VOUT_MODE.
VOUT_MARGIN_HIGH
Read/Write Word
25h
Sets the margin high voltage when commanded by
OPERATION. Must be in format determined by
VOUT_MODE.
VOUT_MARGIN_LOW
Read/Write Word
26h
Sets the margin low voltage when commanded by
OPERATION. Must be in format determined by
VOUT_MODE.
VOUT_TRANSITION_RATE
Read/Write Word
27h
DESCRIPTION
Sets the rate at which the output changes voltage due to
VOUT_COMMAND or OPERATION commands.
mV/s; exp = [0,-1,-2,-3,-4]
VOUT_DROOP
Read/Write Word
28h
VOUT_SCALE_LOOP
Read/Write Word
29h
51
www.irf.com | © 2016 International Rectifier
Sets the rate at which the output voltage decreases or
increases with increasing or decreasing output current for
use with Adaptive Voltage Positioning.
Sets the gain of the output voltage sensing circuitry to take
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
COMMAND
PMBUS
PROTOCOL
COMMAND
CODE
DESCRIPTION
into account an external resistor divider.
Fixed to E8 08h
FREQUENCY_SWITCH
Read/Write Word
33h
Sets the switching frequency in KHz per table found in user
note AN00031. Exp = 0, 1
VIN_ON
Read/Write Word
35h
Sets the value of the input voltage at which the unit should
begin power conversion. Exp = -1.
VIN_OFF
Read/Write Word
36h
Sets the value of the input voltage that the unit, once
operation has started, should stop power conversion.
Exp = -1.
INTERLEAVE
Read/Write Word
37h
The INTERLEAVE command is used to arrange multiple
units so that their switching periods can be distributed in
time. This may be used to facilitate paralleling of multiple
units or to reduce ac currents injected into the power bus.
Only available on parts with the SYNC function.
IOUT_CAL_OFFSET
Read/Write Word
39h
Used to null out any offsets in the output current sensing
circuitry. Exp = -2.
VOUT_OV_FAULT_LIMIT
Read Only
40h
Returns the value of the output voltage, measured at the
sense or output pins, that causes an output overvoltage
fault.
VOUT_OV_FAULT_RESPONSE
Read/Write Byte
41h
Instructs the device on what action to take in response to an
output overvoltage fault. Only shutdown and ignore are
supported.
VOUT_OV_WARN_LIMIT
Read/Write Word
42h
Sets the value of the output voltage, measured at the sense
or output pins, that causes an output overvoltage warning.
Format as determined by VOUT_MODE.
VOUT_UV_WARN_LIMIT
Read/Write Word
43h
Sets the value of the output voltage, measured at the
sense or output pins, that causes an output voltage low
warning. Format as determined by VOUT_MODE.
VOUT_UV_FAULT_LIMIT
Read Only
44h
Returns the value of the output voltage, measured at the
sense or output pins, that causes an output undervoltage
fault.
VOUT_UV_FAULT_RESPONSE
Read/Write Byte
45h
Instructs the device on what action to
take in response to an output undervoltage fault.
Only shutdown and ignore are supported.
IOUT_OC_FAULT_LIMIT
Read/Write Word
46h
IOUT_OC_FAULT_RESPONSE
Read/Write Byte
47h
IOUT_OC_WARN_LIMIT
Read/Write Word
4Ah
OT_FAULT_LIMIT
Read/Write Word
4Fh
Sets the value of the output current, in amperes, that causes
the overcurrent detector to indicate an overcurrent fault
condition. Set by writing this command in Linear format with
a -1 exponent.
Instructs the device on what action to take in response to an
output overcurrent fault.
Only C0h (shutdown immediately), F8h (hiccup forever), and
D8 (hiccup 3 times) are supported.
Sets the value of the output current that causes an output
overcurrent warning. Set by writing this command in Linear
format with a -1 exponent.
Sets the temperature, in degrees Celsius, of the unit at
which it should indicate an overtemperature fault.
Exp = 0.
OT_FAULT_RESPONSE
52
Read/Write Byte
www.irf.com | © 2016 International Rectifier
50h
Instructs the device on what action to take in response to an
overtemperature fault. Only shutdown and ignore are
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
COMMAND
PMBUS
PROTOCOL
COMMAND
CODE
DESCRIPTION
supported.
OT_WARN_LIMIT
Read/Write Word
51h
Sets the temperature, in degrees Celsius, of the unit at
which it should indicate an Overtemperature Warning alarm.
Exp = 0.
VIN_OV_FAULT_LIMIT
Read/Write Word
55h
Sets the value of the input voltage that causes an input
overvoltage fault. Exp = -4.
VIN_OV_FAULT_RESPONSE
Read/Write Byte
56h
Instructs the device on what action to take in response to an
input overvoltage fault. Only shutdown and ignore are
supported.
VIN_UV_WARN_LIMIT
Read/Write Word
58h
Sets the value of the input voltage that causes an input
voltage low warning. Exp = -4.
IIN_OC_WARN_LIMIT
Read/Write Word
5Dh
POWER_GOOD_ON
Read/Write Word
5Eh
Sets the value of the input current, in amperes,
that causes a warning that the input current is high.
Exp = -1.
Sets the output voltage at which an optional
POWER_GOOD signal should be asserted.
Format according to VOUT_MODE.
Sets the output voltage at which an optional
POWER_GOOD_OFF
Read/Write Word
5Fh
POWER_GOOD signal should be negated.
Format according to VOUT_MODE.
TON_DELAY
Read/Write Word
60h
TON_RISE
Read/Write Word
61h
Sets the time, in milliseconds, from when a start condition is
received (as programmed by the ON_OFF_CONFIG
command) until the output voltage starts to rise. Exp = 0.
Sets the time, in milliseconds, from when the output starts to
rise until the voltage has entered the regulation band.
Exp = 0.
Sets an upper limit, in milliseconds, on how
TON_MAX_FAULT_LIMIT
Read/Write Word
62h
TON_MAX_FAULT_RESPONSE
Read/Write Byte
63h
Instructs the device on what action to take in response to a
TON_MAX fault. Only shutdown and ignore are supported.
long the unit can attempt to power up the output without
reaching the output undervoltage fault limit. Exp = 0.
TOFF_DELAY
Read/Write Word
64h
Sets the time, in milliseconds, from when a stop condition is
received (as programmed by the ON_OFF_CONFIG
command) until the unit stops transferring energy to the
output. Exp = 0.
TOFF_FALL
Read/Write Word
65h
Sets the time, in milliseconds, from the end of the turn-off
delay time until the voltage is commanded to zero. Exp = 0.
78h
Returns 1 byte where the bit meanings are:
Bit <7> Reserved
Bit <6> Output off (due to fault or enable)
Bit <5> Output over-voltage fault
Bit <4> Output over-current fault
Bit <3> Input Under-voltage fault
Bit <2> Temperature fault
Bit <1> Communication/Memory/Logic fault
Bit <0>: Reserved
79h
Returns 2 bytes where the Low byte is the same as the
STATUS_BYTE data. The High byte has bit meanings are:
Bit <7> Output high or low fault
Bit <6> Output over-current fault
Bit <5> Input under-voltage fault
STATUS_BYTE
STATUS_WORD
53
Read/Write Byte
Read/Write Word
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
COMMAND
PMBUS
PROTOCOL
COMMAND
CODE
DESCRIPTION
Bit <4> MFR_SPECIFIC
Bit <3> POWER_GOOD#
Bit <2:0> Reserved
STATUS_VOUT
STATUS_IOUT
Read/Write Byte
Read/Write Byte
7Ah
Bit <7>
Bit <6>
Bit <5>
Bit <4>
Bit <3>
Bit <2>
Bit <1>
Bit <0>
Output Overvoltage Fault
Output Overvoltage Warning
Output Undervoltage Warning
Output Undervoltage Fault
VOUT_MAX Warning
TON_MAX_FAULT
Reserved
Reserved
7Bh
Bit <7> Output Overcurrent Fault
Bit <6> Reserved
Bit <5> Output Overcurrent Warning
Bit <4> Reserved
Bit <3> Current Share Fault
Bit <2:0> Reserved
STATUS_INPUT
Read/Write Byte
7Ch
Bit <7>
Bit <6>
Bit <5>
Bit <4>
Bit <3>
Bit <2>
Bit <1>
Bit <0>
STATUS_TEMPERATURE
Read/Write Byte
7Dh
Bit <7> Over Temperature Fault
Bit <6> Over Temperature Warning
Bit <5:0> Reserved
7Eh
Returns 1 byte where the bit meanings are:
Bit <7> Invalid or unsupported command
Bit <6> Invalid or unsupported data
Bit <5> PEC fault
Bit <4:2> Reserved
Bit <1> Other communication fault not listed here
Bit <0> Reserved
STATUS_CML
Read/Write Byte
Input Overvoltage Fault
Reserved
Input Undervoltage Warning
Input Undervoltage Fault
Unit Off For Insufficient Input Voltage
Reserved
Input Overcurrent Warning
Reserved
STATUS_MFR_SPECIFIC
Read/Write Byte
80h
Returns 1 byte where the bit meanings are:
Bit <7:4> Reserved
Bit <3> Loss of SYNC
Bit <2> Driver Fault
Bit <1> Unpopulated Phase
Bit <0> External Overtemperature Fault
READ_VIN
Read Word
88h
Returns the input voltage in Volts
READ_IIN
Read Word
89h
Returns the input current in Amperes
READ_VOUT
Read Word
8Bh
Returns the output voltage in the format set by
VOUT_MODE
READ_IOUT
Read Word
8Ch
Returns the output current in Amperes
READ_TEMPERATURE_1
Read Word
8Dh
Returns the addressed loop NTC temperature in degrees
Celsius
READ_TEMPERATURE_2
Read Word
8Eh
Returns the other loop NTC temperature in degrees Celsius
READ_DUTY_CYCLE
Read Word
94h
Returns the duty cycle of the PMBus device’s main
power converter in percent.
54
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
COMMAND
PMBUS
PROTOCOL
COMMAND
CODE
READ_POUT
Read Word
96h
Returns the output power in Watts
READ_PIN
Read Word
97h
Returns the input power in Watts
PMBUS_REVISION
Read Byte
98h
Reports PMBus Part I rev 1.1 & PMBUs
Part II rev 1.2(draft)
MFR_ID
Block Read/Write
Byte count = 2
99h
The MFR_ID is set to IR (ASCII 52 49) unless programmed
different in the USER registers of the controller.
MFR_MODEL
Block Read,
byte count = 1
9Ah
The MFR_Model is the same as the device ID if the USER
register for Manufacturer model is 00. Otherwise
MFR_Model command returns the value in the USER
register for MFR_Model.
MFR_REVISION
Block Read,
byte count = 2
9Bh
The MFR_Revision is the same as the device revision if the
USER register for Manufacturer revision is 00. Otherwise
MFR_Revision command returns the value in the USER
register for MFR_Revison.
MFR_DATE
Block Read/Write
Byte count = 2
9Dh
The MFR_DATE command returns the value in the USER
register called MFR_DATE
IC_DEVICE_ID
Block Read
ADh
Returns a 1 byte code with the following values:
50 = IR35204
IC_DEVICE_REV
Block Read
AEh
The IC revision that is stored inside the IC
MFR_READ_REG
Custom MFR
protocol
D0h
MFR_WRITE_REG
Write Word
D1h
55
www.irf.com | © 2016 International Rectifier
DESCRIPTION
Read I2C registers
Write to I2C registers, High Byte is reg, low byte is data
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
11-BIT LINEAR DATA FORMAT
Monitored parameters use the Linear Data Format (Figure 64) encoding into 1 Word (2 bytes), where:
Value Y  2N
Note: N and Y are “signed” values.
Databyte Low
Databyte High
7 6 5 4 3
2 1 0
7 6 5 4 3 2 1 0
N
Y
Figure 64: 11-bit Linear Data Format
16-BIT LINEAR DATA FORMAT
This format is only used for VOUT related commands (READ_VOUT, VOUT_MARGIN_HIGH,
VOUT_MARGIN_LOW, VOUT_COMMAND):
Value Y  2N
Note: N is a “signed” value. If VOUT is set to linear format (by VOUT_MODE), then N is set by the VOUT_MODE
command and only Y is returned in the data-field as a 16-bit unsigned number.
Figure 65: 16-bit Linear Data Format
56
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
IR35204
SVID REGISTERS
A list of all the SVID registers is given in Table 57. SVID registers supported by IR35204 in VR12.5 and IMVP8 mode conform
to VR12.5 and IMVP8 specifications respectively.
Table 57: SVID Registers
Register
Address
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
Register Name
Access
VR12.5 Mode
IMVP8 Mode
Vendor ID
Product ID
Product Revision
Product Date Code
Lot Code
Protocol ID
Capability
Vendor-Timeout
Vendor Use
Vendor Use
Vendor Use
Vendor Use
Vendor Use
RO
RO
RO
RO
RO
RW
RO
-
0D
Vendor Use
RO
0E
Vendor Use
RW
0F
Vendor Use
RW
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
Status_1
Status_2
Temperature Zone
Reserved
Reserved
Output Current
Output Voltage
VR Temperature
Output Power
Input Current
Input Voltage
Input Power
Status 2 Last Read
Future Command
Future Command
Future Command
Future Command
ICC Max
Temp Max
DC_LL
SR_Fast
SR_Slow
Vboot
VR Tolerance
Current-Offset
Temperature Offset
Slow Slew Rate Select
PS4 Exit Latency
PS3 Exit Latency
Enable to Ready
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
Supported
Supported
Supported
Not Supported
Not Supported
Supported
Supported
Supported
Supported
Not Supported
Not Supported
Not Supported
Not Supported
Supported, For
Factor Use Only
Supported, For
Factor Use Only
Supported, For
Factor Use Only
Supported
Supported
Supported
Not Supported
Not Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Not Supported
Not Supported
Not Supported
Not Supported
Supported
Supported
Supported
Supported
Supported
Supported
Not Supported
Supported
Supported
Not Supported
Not Supported
Not Supported
Not Supported
Supported
Supported
Supported
Not Supported
Not Supported
Supported
Supported
Supported
Supported
Not Supported
Not Supported
Not Supported
Not Supported
Supported, For
Factor Use Only
Supported, For
Factor Use Only
Supported, For
Factor Use Only
Supported
Supported
Supported
Not Supported
Not Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Not Supported
Not Supported
Not Supported
Not Supported
Supported
Supported
Supported
Supported
Supported
Supported
Not Supported
Supported
Supported
Supported
Supported
Supported
Supported
57
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
Register
Address
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
58
IR35204
Register Name
Access
VR12.5 Mode
IMVP8 Mode
Pin Max
Pin Alert Threshold
VOUT Max
VID Setting
Pwr State
Offset
Multi VR Config
Set RegADR
Future Command
Future Command
Future Command
Future Command
Work Point 0
Work Point 1
Work Point 2
Work Point 3
Work Point 4
Work Point 5
Work Point 6
Work Point 7
IVID1-VID
IVID1-I
IVID2-VID
IVID2-I
IVID3-VID
IVID3-I
RO
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
Not Supported
Not Supported
Supported
Supported
Supported
Supported
Supported
Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Not Supported
Supported
Supported
Supported
Supported
Supported
Supported
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
IR35204
MARKING INFORMATION
PIN 1
PART #
ASSEMBLER (A)/DATE(YWW)/MARKING CODE(X)
LOT CODE
(ENG MODE - MIN. LAST 5 DIGITS OF EATI #)
(PROD MODE – 4 DIGIT SPN CODE)
35204
AYWWX
XXXXX
Figure 66: Package Marking
PACKAGE INFORMATION
QFN 5x5mm, 40-pin
Figure 67: Package Dimensions
59
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
IR35204
3+1 Dual Output Digital Multi-Phase Controller
ENVIRONMENTAL QUALIFICATIONS
Industrial
Qualification Level
Moisture Sensitivity Level
QFN package
MSL2
Machine Model
JESD22-A115-A
Human Body Model
JESD22-A114-E
Charged Device Model
JESD22-C101-C
Latch-up
JESD78
ESD
RoHS Compliant
Yes
† Qualification standards can be found at International Rectifier web site: http://www.irf.com
†† Exceptions to AEC-Q101 requirements are noted in the qualification report.
60
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6
3+1 Dual Output Digital Multi-Phase Controller
IR35204
Data and specifications subject to change without notice.
This product will be designed and qualified for the Industrial market.
Qualification Standards can be found on IR’s Web site.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7903
Visit us at www.irf.com for sales contact information.
www.irf.com
61
www.irf.com | © 2016 International Rectifier
February 8, 2016 | V1.6