Burr-Brown OPA121 Low cost precision difet operational amplifier Datasheet

OPA121
®
Low Cost Precision Difet ®
OPERATIONAL AMPLIFIER
FEATURES
APPLICATIONS
● LOW NOISE: 6nV/√Hz typ at 10kHz
● LOW BIAS CURRENT: 5pA max
● LOW OFFSET: 2mV max
● OPTOELECTRONICS
● DATA ACQUISITION
● TEST EQUIPMENT
● MEDICAL EQUIPMENT
● LOW DRIFT: 3µV/°C typ
● HIGH OPEN-LOOP GAIN: 110dB min
● HIGH COMMON-MODE
REJECTION: 86dB min
● RADIATION HARD EQUIPMENT
DESCRIPTION
Case (TO-99) and Substrate
The OPA121 is a precision monolithic dielectricallyisolated FET (Difet ®) operational amplifier. Outstanding performance characteristics are now
available for low-cost applications.
Noise, bias current, voltage offset, drift, open-loop
gain, common-mode rejection, and power supply
rejection are superior to BIFET® amplifiers.
Very low bias current is obtained by dielectric
isolation with on-chip guarding.
Laser-trimming of thin-film resistors gives very low
offset and drift. Extremely low noise is achieved with
new circuit design techniques (patented). A new
cascode design allows high precision input specifications and reduced susceptibility to flicker noise.
Standard 741 pin configuration allows upgrading of
existing designs to higher performance levels.
8
7
+VCC
–In
2
3
+In
Noise-Free
Cascode*
6
Output
Trim 10kΩ
1
5
Trim 10kΩ
2kΩ
2kΩ
2kΩ
2kΩ
4
–VCC
*Patented
OPA121 Simplified Circuit
Difet ®, Burr-Brown Corp.
BIFET®, National Semiconductor Corp.
International Airport Industrial Park • Mailing Address: PO Box 11400
Tel: (520) 746-1111 • Twx: 910-952-1111 • Cable: BBRCORP •
• Tucson, AZ 85734 • Street Address: 6730 S. Tucson Blvd. • Tucson, AZ 85706
Telex: 066-6491 • FAX: (520) 889-1510 • Immediate Product Info: (800) 548-6132
© 1984 Burr-Brown Corporation
PDS-539F
Printed in U.S.A. September, 1993
SPECIFICATIONS
ELECTRICAL
At VCC = ±15VDC and TA = +25°C unless otherwise noted. Pin 8 connected to ground.
OPA121KM
PARAMETER
CONDITIONS
INPUT
NOISE
Voltage, fO = 10Hz
fO = 100Hz
fO = 1kHz
fO = 10kHz
fB = 10Hz to 10kHz
fB = 0.1Hz to 10 Hz
Current, fB = 0.1Hz to 10Hz
fO = 0.1Hz thru 20kHz
MIN
(1)
TYP
OPA121KP, KU
MAX
MIN
40
15
8
6
0.7
1.6
15
0.8
(1)
(1)
(1)
(1)
(1)
(1)
(1)
TYP
MAX
50
18
10
7
0.8
2
21
1.1
UNITS
nV/√Hz
nV/√Hz
nV/√Hz
nV/√Hz
µVrms
µVp-p
fA, p-p
fA/√Hz
VOLTAGE(2)
OFFSET
Input Offset Voltage
Average Drift
Supply Rejection
±0.5
±3
104
±6
VCM = 0VDC
Device Operating
VCM = 0VDC
Device Operating
VCM = 0VDC
TA = TMIN to TMAX
86
BIAS CURRENT(2)
Input Bias Current
OFFSET CURRENT(2)
Input Offset Current
IMPEDANCE
Differential
Common-Mode
±2
±10
±50
±0.5
±3
104
±6
±50
mV
µV/°C
dB
µV/V
±1
±5
±1
±10
pA
±0.7
±4
±0.7
±8
pA
86
1013 || 1
1014 || 3
VOLTAGE RANGE
Common-Mode Input Range
Common-Mode Rejection
OPEN-LOOP GAIN, DC
Open-Loop Voltage Gain
±3
±10
1013 || 1
1014 || 3
Ω || pF
Ω || pF
VIN = ±10VDC
±10
86
±11
104
±10
82
±11
100
V
dB
RL ≥ 2kΩ
110
120
106
114
dB
FREQUENCY RESPONSE
Unity Gain, Small Signal
Full Power Response
Slew Rate
Settling Time, 0.1%
0.01%
Overload Recovery,
50% Overdrive(3)
20Vp-p, RL = 2kΩ
VO = ±10V, RL = 2kΩ
Gain = –1, RL = 2kΩ
10V Step
2
32
2
6
10
2
32
2
6
10
MHz
kHz
V/µs
µs
µs
Gain = –1
5
5
µs
RATED OUTPUT
Voltage Output
Current Output
Output Resistance
Load Capacitance Stability
Short Circuit Current
RL = 2kΩ
VO = ±10VDC
DC, Open Loop
Gain = +1
±12
±10
100
1000
40
V
mA
Ω
pF
mA
±15
VDC
10
POWER SUPPLY
Rated Voltage
Voltage Range,
Derated Performance
Current, Quiescent
TEMPERATURE RANGE
Specification
Operating
Storage
θ Junction-Ambient
±11
±5.5
±12
±10
100
1000
40
±11
±5.5
10
±15
±5
IO = 0mADC
Ambient Temperature
Ambient Temperature
Ambient Temperature
2.5
0
–40
–65
200
±18
4
±5
+70
+85
+150
0
–25
–55
2.5
150(4)
±18
4.5
VDC
mA
+70
+85
+125
°C
°C
°C
°C/W
NOTES: (1) Sample tested. (2) Offset voltage, offset current, and bias current are specified with the units fully warmed up. (3) Overload recovery is defined as
the time required for the output to return from saturation to linear operation following the removal of a 50% input overdrive. (4) 100°C/W for KU grade.
The information provided herein is believed to be reliable; however, BURR-BROWN assumes no responsibility for inaccuracies or omissions. BURR-BROWN assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change
without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. BURR-BROWN does not authorize or warrant
any BURR-BROWN product for use in life support devices and/or systems.
®
OPA121
2
ELECTRICAL (FULL TEMPERATURE RANGE SPECIFICATIONS)
At VCC = ±15VDC and TA = TMIN to TMAX unless otherwise noted.
OPA121KM
PARAMETER
TEMPERATURE RANGE
Specification Range
INPUT
OFFSET VOLTAGE(1)
Input Offset Voltage
Average Drift
Supply Rejection
CONDITIONS
MIN
Ambient Temperature
0
±1
±3
94
±20
VCM = 0VDC
Device Operating
VCM = 0VDC
Device Operating
VCM = 0VDC
82
BIAS CURRENT(1)
Input Bias Current
OFFSET CURRENT(1)
Input Offset Current
VOLTAGE RANGE
Common-Mode Input Range
Common-Mode Rejection
POWER SUPPLY
Current, Quiescent
OPA121KP, KU
MAX
MIN
+70
0
TYP
±3
±10
MAX
UNITS
+70
°C
±5
±10
±80
±1
±3
94
±20
±80
mV
µV/°C
dB
µV/V
±23
±115
±23
±250
pA
±16
±100
±16
±200
pA
82
VIN = ±10VDC
±10
82
±11
98
±10
80
±11
96
V
dB
RL ≥ 2kΩ
106
116
100
110
dB
RL = 2kΩ
VO = ±10VDC
VO = 0VDC
±10.5
±5.25
10
±11
±10
40
±10.5
±5.25
10
±11
±10
40
V
mA
mA
OPEN-LOOP GAIN, DC
Open-Loop Voltage Gain
RATED OUTPUT
Voltage Output
Current Output
Short Circuit Current
TYP
IO = 0mADC
2.5
4.5
2.5
5
mA
NOTE: (1) Offset voltage, offset current, and bias current are measured with the units fully warmed up.
ABSOLUTE MAXIMUM RATINGS
CONNECTION DIAGRAMS
Top View
Supply ........................................................................................... ±18VDC
Internal Power Dissipation(1) ......................................................... 500mW
Differential Input Voltage ............................................................... ±36VDC
Input Voltage Range ..................................................................... ±18VDC
Storage Temperature Range
M package .................................................................... –65°C to +150°C
P, U packages ............................................................... –55°C to +125°C
Operating Temperature Range
M package ...................................................................... –40°C to +85°C
P, U packages ................................................................. –25°C to +85°C
Lead Temperature
M, P packages (soldering, 10s) ................................................... +300°C
U package (soldering, 3s) ........................................................... +260°C
Output Short-Circuit Duration(2) ............................................... Continuous
Junction Temperature .................................................................... +175°C
Substrate and Case
Offset
Trim 1
–In 2
+In
OPA121KM
OPA121KP
OPA121KU
PACKAGE
TO-99
8-Pin Plastic DIP
8-Pin SOIC
001
006
182
7 +VCC
OPA121
3
6
5
Output
Offset
Trim
–V CC
Top View
PACKAGE INFORMATION
MODEL
8
4
NOTES: (1) Packages must be derated based on θJA = 150°C/W
(P package); θJA = 200°C/W (M package); θJA = 100°C/W (U package).
(2) Short circuit may be to power supply common only. Rating applies to
+25°C ambient. Observe dissipation limit and TJ.
PACKAGE DRAWING
NUMBER(1)
M-Package TO-99 (Hermetic)
P-Package Plastic Mini-DIP
U-Package Plastic SOIC
Offset Trim
1
8
Substrate
–In
2
7
+VCC
OPA121
+In
3
6
Output
–V CC
4
5
Offset Trim
NOTE: (1) For detailed drawing and dimension table, please see end of data
sheet, or Appendix D of Burr-Brown IC Data Book.
ORDERING INFORMATION
MODEL
OPA121KM
OPA121KP
OPA121KU
PACKAGE
TEMPERATURE
RANGE
TO-99
8-Pin Plastic DIP
8-Pin SOIC
0°C to +70°C
0°C to +70°C
0°C to +70°C
®
3
OPA121
TYPICAL PERFORMANCE CURVES
TA = +25°C, VCC = ±15VDC unless otherwise noted.
BIAS AND OFFSET CURRENT
vs TEMPERATURE
INPUT VOLTAGE NOISE SPECTRAL DENSITY
1k
1k
100
100
KM
10
100
KM
10
10
1
1
0.1
1
0.1
0.01
0.01
1
10
100
1k
10k
Frequency (Hz)
100k
1M
–50
–25
1
Offset Current
KM
0.1
Power Supply Rejection (dB)
Offset Current (pA)
0
+5
+125
+10
1M
10M
120
100
80
60
40
20
1
+15
10
100
1k
10k
100k
Frequency (Hz)
Common-Mode Voltage (V)
COMMON-MODE REJECTION
vs FREQUENCY
OPEN-LOOP FREQUENCY RESPONSE
140
140
KM
KM
–45
120
120
100
Voltage Gain (dB)
Common-Mode Rejection (dB)
+100
0
0.01
0.01
–5
+75
80
60
40
Gain
100
Ø
80
60
Phase
Margin
∼
≈ 65°
40
–90
–135
20
20
0
–180
0
1
10
100
1k
10k
100k
1M
1
10M
100
1k
10k
Frequency (Hz)
Frequency (Hz)
®
OPA121
10
4
100k
1M
10M
Phase Shift (Degrees)
Bias Current (pA)
Bias Current
–10
+50
140
10
–15
+25
POWER SUPPLY REJECTION
vs FREQUENCY
10
0.1
0
Ambient Temperature (°C)
BIAS AND OFFSET CURRENT
vs INPUT COMMON-MODE VOLTAGE
1
Offset Current (pA)
KP, KU
Bias Current (pA)
Voltage Noise (nV/√Hz)
1k
TYPICAL PERFORMANCE CURVES (CONT)
TA = +25°C, VCC = ±15VDC unless otherwise noted.
SMALL SIGNAL TRANSIENT RESPONSE
LARGE SIGNAL TRANSIENT RESPONSE
+80
Output Voltage (mV)
Output Voltage (V)
+15
0
+40
0
+40
-15
+80
0
25
0
50
1
2
3
4
5
Time(µs)
Time(µs)
INPUT CURRENTS vs INPUT VOLTAGE
WITH ±VCC PINS GROUNDED
Input Current (mA)
+2
Maximum Safe Current
IIN
+1
V
0
–1
Maximum Safe Current
–2
–15
–10
–5
0
+5
+10
+15
Input Voltage (V)
APPLICATIONS INFORMATION
+VCC
OFFSET VOLTAGE ADJUSTMENT
7
2
The OPA121 offset voltage is laser-trimmed and will require
no further trim for most applications. As with most amplifiers, externally trimming the remaining offset can change
drift performance by about 0.3µV/°C for each 100µV of
adjusted offset. Note that the trim (Figure 1) is similar to
operational amplifiers such as 741 and AD547. The OPA121
can replace most BIFET amplifiers by leaving the external
null circuit unconnected.
6
OPA121
1
3
5
±10mV Typical
Trim Range
4
*
–VCC
*10k Ω to 1M Ω
Trim Potentiometer
(100k Ω Recommended)
INPUT PROTECTION
FIGURE 1. Offset Voltage Trim.
Conventional monolithic FET operational amplifiers require
external current-limiting resistors to protect their inputs
against destructive currents that can flow when input FET
gate-to-substrate isolation diodes are forward-biased. Most
BIFET amplifiers can be destroyed by the loss of –VCC.
than 6V more negative than –VCC. A 10kΩ series resistor
will limit input current to a safe level with up to ±15V input
levels even if both supply voltages are lost.
Static damage can cause subtle changes in amplifier input
characteristics without necessarily destroying the device. In
precision operational amplifiers (both bipolar and FET types),
Unlike BIFET amplifiers, the Difet OPA121 requires input
current limiting resistors only if its input voltage is greater
®
5
OPA121
this may cause a noticeable degradation of offset voltage and
drift.
Non-Inverting
Static protection is recommended when handling any
precision IC operational amplifier.
8
2
GUARDING AND SHIELDING
3
In
As in any situation where high impedances are involved,
careful shielding is required to reduce “hum” pickup in input
leads. If large feedback resistors are used, they should also
be shielded along with the external input circuitry.
Buffer
8
2
6 Out
OPA121
3
OPA121
6 Out
In
TO-99 Bottom View
Inverting
Leakage currents across printed circuit boards can easily
exceed the bias current of the OPA121. To avoid leakage
problems, it is recommended that the signal input lead of the
OPA121 be wired to a Teflon™ standoff. If the OPA121 is
to be soldered directly into a printed circuit board, utmost
care must be used in planning the board layout. A “guard”
pattern should completely surround the high-impedance input leads and should be connected to a low-impedance point
which is at the signal input potential.
4 5 6
In
3
2
3
6 Out
OPA121
7
2
8
8
1
Mini-DIP Bottom View
The amplifier case should be connected to any input shield
or guard via pin 8. This insures that the amplifier itself is
fully surrounded by guard potential, minimizing both leakage and noise pickup (see Figure #2).
1
8
BOARD LAYOUT
FOR INPUT GUARDING
Guard top and bottom of board.
Alternate: use Teflon standoff
for sensitive input pins.
7
2
6
3
4
5
If guarding is not required, pin 8 (case) should be connected
to ground.
FIGURE 2. Connection of Input Guard.
BIAS CURRENT CHANGE
VERSUS COMMON-MODE VOLTAGE
80
70
Input Bias Current (pA)
The input bias currents of most popular BIFET operational
amplifiers are affected by common-mode voltage (Figure 3).
Higher input FET gate-to-drain voltage causes leakage and
ionization (bias) currents to increase. Due to its cascode
input stage, the extremely-low bias current of the OPA121
is not compromised by common-mode voltage.
60
50
AD547
40
30
LF155
LF156/157
20
10
0
–10
Teflon™ E.I. du Pont de Nemours & Co.
LF156/157
TA = +25°C; curves taken from
mfg. published typical data
LF155
AD547
OPA121
OPA121
OP-15/16/17 "Perfect Bias Current Cancellation"
–20
–10
–5
0
+5
+10
Common-Mode Voltage (VDC)
FIGURE 3. Input Bias Current vs Common-Mode Voltage.
®
OPA121
6