Ordering information AC-DC Power Supplies Open Frame/Enclosed type LDC15F LD 1 C 2 15 3 F 4 -1 5 -O 6 1Series name 2Multiple output 3Output wattage 4Universal input 5Output voltage combination 6Optional *4 C :with Coating G :Low leakage current S :with Chassis SN :with Chassis & cover Y :with Potentiometer R LDC MODEL V1 V2 V3 DC OUTPUT LDC15F-1 +5V 2.0(Peak 3.0)A +12V 0.3(Peak 0.6)A -12V 0.2(Peak 0.3)A LDC15F-2 +5V 2.0(Peak 3.0)A +15V 0.3(Peak 0.6)A -15V 0.2(Peak 0.3)A SPECIFICATIONS INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 * * MODEL VOLTAGE[V] CURRENT[A] FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V LDC15F-1 LDC15F-2 AC85 - 264 1f or DC110 - 370 0.4typ (Io=100%) 47 - 440 or DC 70typ (Io=100%) 25typ (Io=100%) 50typ (Io=100%) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) +5 +12 -12 +5 +15 -15 0 - 2.0 (Peak 3.0) 0 - 0.3 (Peak 0.6) 0 - 0.2 (Peak 0.3) 0 - 2.0 (Peak 3.0) 0 - 0.3 (Peak 0.6) 0 - 0.2 (Peak 0.3) 20max 48max 48max 20max 60max 60max 100max 120max 120max 100max 150max 150max 100max 120max 120max 100max 120max 120max 140max 160max 160max 140max 160max 160max 120max 150max 150max 120max 150max 150max 160max 180max 180max 160max 180max 180max 50max 350max 350max 50max 350max 350max 60max 420max 420max 60max 420max 420max 20max 20max xx xx xx xx 100max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%), 20typ (ACIN 100V, Io=100%), 100typ (ACIN 200V, Io=100%) Fixed Fixed Fixed Fixed Fixed Fixed 4.9 to 5.3 11.4 to 12.6 -11.4 to -12.6 4.9 to 5.3 14.25 to 15.75 -14.25 to -15.75 Works over 105% of rating and recovers automatically Works over 115% of rating by zener diode clamping (+5V only) Not provided Not provided Not provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B 50X26X127mm [1.97X1.02X5 inches] (WXHXD) /150g max (without chassis and cover) ACIN 100V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] *1 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *2 RIPPLE[mVp-p] -10 - 0C *2 0 to +50C *2 RIPPLE NOISE[mVp-p] -10 - 0C *2 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *3 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OUTPUT-OUTPUT(V1-V2,V3) OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD Convection Peak load for 10sec. or less is acceptable if the total wattage is less than the rated wattage(-1: 16W, -2: 17.5W).When the load of +5V is OA, other output can be drawn by 80% of rated current. Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN:RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output. Please contact us about safety approvals for the model with option. Avoid prolonged use under over-load. Derating is required when operated with chassis and cover. LDC-2 LDC15F External view LDC f3.5 [0.14] 38 [1.50] [0.39] 23 [0.91] PCB t=1.6 [0.06] [0.14] 6 [0.24] [0.75] 147 [5.79] 135±0.5 [5.31] 3.5 f3.5 [0.14] 3max [0.12] 28.5 [1.12] 57 [2.24] 3.5 [0.14] [0.59] 6 [0.24] 10 19 [0.95] 120±0.5 [4.72] 127 [5] 25±0.5 [0.98] 15 4.75 3.5 [0.14] [0.19] 135±0.5 [5.31] 19 3.5 [0.14] 50 [1.97] 43±0.5 [1.69] 4-f3.5 [0.14] ¶ Weight: 150g max(without chassis and cover) ¶ Tolerance: t1[t0.04] ¶ Dimensions in mm,[ ]=inches ¶ PCB Material: Glass composite(CEM3) ¶ Chassis and cover is optional. ¶ Mounting torque: 0.6N·m(6.3kgf·cm)max Performance data ¡STATIC CHARACTERISTICS (LDC15F-1) ¡RISE TIME & FALL TIME (LDC15F-1) ¡OVERCURRENT CHARACTERISTICS (LDC15F-1) ¡DERATING CURVE LDC-3 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LDC30F LD 1 C 2 30 3 F 4 -1 5 -O 6 1Series name 2Multiple output 3Output wattage 4Universal input 5Output voltage combination 6Optional *4 C :with Coating G :Low leakage current S :with Chassis SN :with Chassis & cover Y :with Potentiometer R LDC MODEL V1 V2 V3 DC OUTPUT LDC30F-1 +5V 3.0(Peak 4.5)A +12V 1.2(Peak 2.0)A -12V 0.3(Peak 0.45)A LDC30F-2 +5V 3.0(Peak 4.5)A +15V 1.0(Peak 2.0)A -15V 0.3(Peak 0.45)A SPECIFICATIONS INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 * * MODEL VOLTAGE[V] CURRENT[A] FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V LDC30F-1 LDC30F-2 AC85 - 264 1f or DC110 - 370 0.8typ (Io=100%) 47 - 440 or DC 72typ (Io=100%) 25typ (Io=100%) (At cold start) 50typ (Io=100%) (At cold start) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) +5 +12 -12 +5 +15 -15 0 - 3.0 (Peak 4.5) 0 - 1.2 (Peak 2.0) 0 - 0.3 (Peak 0.45) 0 - 3.0 (Peak 4.5) 0 - 1.0 (Peak 2.0) 0 - 0.3 (Peak 0.45) 20max 48max 48max 20max 60max 60max 100max 120max 150max 100max 120max 150max 100max 120max 120max 100max 120max 120max 150max 160max 160max 150max 160max 160max 120max 150max 150max 120max 150max 150max 170max 180max 180max 170max 180max 180max 50max 350max 350max 50max 350max 350max 60max 420max 420max 60max 420max 420max 20max 20max xx xx xx xx 100max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%), 20typ (ACIN 100V, Io=100%), 100typ (ACIN 200V, Io=100%) Fixed Fixed Fixed Fixed Fixed Fixed 4.9 to 5.3 11.4 to 12.6 -11.4 to -12.6 4.9 to 5.3 14.25 to 15.75 -14.25 to -15.75 Works over 105% of rating and recovers automatically Works at 115 - 140% of rating (+5V only) Not provided Not provided Not provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B 65X26X140mm [2.56X1.02X5.51 inches] (WXHXD) / 220g max (without chassis and cover) ACIN 100V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] *1 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *2 RIPPLE[mVp-p] -10 - 0C *2 0 to +50C *2 RIPPLE NOISE[mVp-p] -10 - 0C *2 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *3 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OUTPUT-OUTPUT(V1-V2,V3) OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD Convection Peak load for 10sec. or less is acceptable if the total wattage is less than the rated wattage(-1: 33W, -2: 34.5W).When the load of +5V is OA, other output can be drawn by 80% of rated current. Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN:RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output. Please contact us about safety approvals for the model with option. Avoid prolonged use under over-load. Derating is required when operated with chassis and cover. LDC-4 LDC30F External view 57.5 [2.26] 36 [1.42] 72 [2.83] 3.5 [0.14] [1.57] 20±0.5 [0.79] 26 16 [0.63] 40±0.5 [1.02] LDC 2-f3.5 [0.14] 132±0.5 [5.20] 140 [5.51] 19 [0.91] 3max [0.12] 38 5 [0.20] [1.50] 160 [6.30] 150±0.5 [5.91] 3.5 10 [0.14] f3.5 [0.14] 23 5 [0.20] [0.36] 9.25 4 [0.16] 150±0.5 [5.91] [0.75] [0.39] 4 [0.16] 65 [2.56] 57±0.5 [2.24] 4-f3.5 [0.14] PCB t=1.6 [0.06] ¶ Weight: 220g max(without chassis and cover) ¶ Tolerance: t1[t0.04] ¶ Dimensions in mm,[ ]=inches ¶ PCB Material: Glass composite(CEM3) ¶ Chassis and cover is optional. ¶ Mounting torque: 0.6N·m(6.3kgf·cm)max Performance data ¡STATIC CHARACTERISTICS (LDC30F-1) ¡RISE TIME & FALL TIME (LDC30F-1) ¡OVERCURRENT CHARACTERISTICS (LDC30F-1) ¡DERATING CURVE LDC-5 Ordering information AC-DC Power Supplies Open Frame/Enclosed type LDC60F LD 1 C 2 60 3 F 4 -1 5 -O 6 1Series name 2Multiple output 3Output wattage 4Universal input 5Output voltage combination 6Optional *4 C :with Coating G :Low leakage current S :with Chassis SN :with Chassis & cover Y :with Potentiometer R LDC MODEL V1 V2 V3 DC OUTPUT LDC60F-1 +5V 5.0(Peak 7.0)A +12V 2.5(Peak 3.5)A -12V 0.5(Peak 0.7)A LDC60F-2 +5V 5.0(Peak 7.0)A +15V 2.0(Peak 3.5)A -15V 0.5(Peak 0.7)A SPECIFICATIONS INPUT OUTPUT PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 * * MODEL VOLTAGE[V] CURRENT[A] FREQUENCY[Hz] EFFICIENCY[%] ACIN 100V LDC60F-1 LDC60F-2 AC85 - 264 1f or DC110 - 370 1.4typ (Io=100%) 47 - 440 or DC 72typ (Io=100%) 30typ (Io=100%) (At cold start) 60typ (Io=100%) (At cold start) 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN) +5 +12 -12 +5 +15 -15 0 - 5.0 (Peak 7.0) 0 - 2.5 (Peak 3.5) 0 - 0.5 (Peak 0.7) 0 - 5.0 (Peak 7.0) 0 - 2.0 (Peak 3.5) 0 - 0.5 (Peak 0.7) 20max 48max 48max 20max 60max 60max 100max 150max 150max 100max 150max 150max 100max 120max 120max 100max 120max 120max 150max 160max 160max 150max 160max 160max 120max 150max 150max 120max 150max 150max 170max 180max 180max 170max 180max 180max 50max 350max 350max 50max 350max 350max 60max 420max 420max 60max 420max 420max 20max 20max xx xx xx xx 200max (ACIN 85V, Io=100%) 10typ (ACIN 85V, Io=100%), 20typ (ACIN 100V, Io=100%), 100typ (ACIN 200V, Io=100%) Fixed Fixed Fixed Fixed Fixed Fixed 4.9 to 5.3 11.4 to 12.6 -11.4 to -12.6 4.9 to 5.3 14.25 to 15.75 -14.25 to -15.75 Works over 105% of rating and recovers automatically Works over 115% of rating by zener diode clamping (only available with V1, V2) Not provided Not provided Not provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature) AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature) -10 to +60C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1 Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B 83X26X185mm [3.27X1.02X7.28 inches] (WXHXD) / 300g max (without chassis and cover) ACIN 100V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] *1 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *2 RIPPLE[mVp-p] -10 - 0C *2 0 to +50C *2 RIPPLE NOISE[mVp-p] -10 - 0C *2 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *3 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG OUTPUT-FG OUTPUT-OUTPUT(V1-V2,V3) OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CASE SIZE/WEIGHT COOLING METHOD Convection Peak load for 10sec. or less is acceptable if the total wattage is less than the rated wattage(-1: 61W, -2: 62.5W).When the load of +5V is OA, other output can be drawn by 80% of rated current. Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN:RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output. Please contact us about safety approvals for the model with option. Avoid prolonged use under over-load. Derating is required when operated with chassis and cover. LDC-6 LDC60F External view 8 7 [0.28] 4.5 7 [0.28] [1.18] 19 11 [0.91] 38 195±0.5 [7.68] f4.5 [0.18] 23 46 [1.81] [1.22] 30±0.5 [0.18] 210 [8.27] 195±0.5 [7.68] 3max [0.12] 92 [3.62] 31 [1.97] 4.5 [0.18] 21 [0.83] 50±0.5 2-f4.5 [1.50] [1.60] [0.75] [0.43] 111±0.5 [4.37] 177±0.5 [6.97] 185 [7.28] 40.75 [0.18] 4 [0.16] LDC [0.31] 83 [3.27] 75±0.5 [2.95] 39±0.5 [1.54] 4 [0.16] 5-f3.5 [0.14] PCB t=1.6 [0.06] ¶ Weight: 300g max(without chassis and cover) ¶ Tolerance: t1[t0.04] ¶ Dimensions in mm,[ ]=inches ¶ PCB Material: Glass composite(CEM3) ¶ Chassis and cover is optional. ¶ Mounting torque: 1.5N·m(16kgf·cm)max Performance data ¡STATIC CHARACTERISTICS (LDC60F-1) ¡RISE TIME & FALL TIME (LDC60F-1) ¡OVERCURRENT CHARACTERISTICS (LDC60F-1) ¡DERATING CURVE LDC-7