MPD D114EHI Low cost, miniature sip 1w, very high isolation dc/dc converter Datasheet

D100EHI Series
Low Cost, Miniature SIP
1W, Very High Isolation
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 1W Output Power
• 6,000 VDC Isolation
• 7 Pin SIP Case
• 5V and 12V Inputs
• Single & Dual Outputs
• 16 Standard Models
• 3.5 MH MTBF
• LOWEST COST!!
Input
Parameter
Conditions
Input Voltage Range
Min.
Typ.
5 VDC Input
4.5
5.0
5.5
12 VDC Input
10.8
12.0
13.2
Input Filter
Units
VDC
Internal Capacitor
Short Circuit Input Power
1,500
mW
Units
Output
Parameter
Conditions
Min.
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Dual Output , Balanced Loads
Typ.
Max.
±2.0
±4.0
%
±1.0
±3.0
%
±1.2
%/%
For Vin Change of 1%
Load Regulation, 5V Input
Iout = 10% to 100%
±15
%
Load Regulation, 12V & 24V Input
Iout = 10% to 100%
±10
%
300
mV P - P
Ripple & Noise (20 MHz) (Note 1)
250
Output Power Protection
120
Temperature Coefficient
RoHS Compliant
Max.
%
±0.01
Output Short Circuit
±0.03
%/ºC
Max.
Units
Momentary (1.0 Seconds)
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Min.
60 Seconds
6,000
500 VDC
1,000
Typ.
VDC
MΩ
Isolation Capacitance
100 kHz, 1V
20
Switching Frequency
5 VDC Input
250
12 VDC Input
50
pF
kHz
Environmental
Parameter
Conditions
Operating Temperature Range
Min.
Ambient
Storage Temperature Range
Cooling
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Max.
Units
-40
Typ.
+85
ºC
-55
+125
ºC
95
%
Free Air Convection
Humidity
RH, Non-condensing
Physical
Case Size
0.77 x 0.38 x 0.50 Inches (19.5 x 9.8 x 12.5 mm)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
0.42 Oz (12g)
Reliability Specifications
Parameter
Conditions
MTBF
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
Typ.
Max.
3.5
Units
MHours
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Min.
Typ.
Max.
5 VDC Input
-0.7
7.5
12 VDC Input
-0.7
15.0
1.5 mm From Case For 10 Sec.
All Models
Units
VDC
300
ºC
1,500
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Input
Model
Number
D101EHI
D102EHI
D103EHI
D104EHI
D105EHI
D106EHI
D107EHI
D108EHI
D111EHI
D112EHI
D113EHI
D114EHI
D115EHI
D116EHI
D117EHI
D118EHI
Voltage (VDC)
Output
Current (mA)
Nominal
Range
Full-Load
No-Load
Voltage
(VDC)
5
5
5
5
5
5
5
5
12
12
12
12
12
12
12
12
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
286
286
278
278
277
277
267
267
113
113
110
110
111
111
107
107
60
60
60
60
60
60
60
60
40
40
40
40
40
40
40
40
5.0
9.0
12.0
15.0
±5.0
±9.0
±12.0
±15.0
5.0
9.0
12.0
15.0
±5.0
±9.0
±12.0
±15.0
Current
Current
(mA, Max) (mA, Min)
200
111
84
67
±100
±56
±42
±33
200
111
84
67
±100
±56
±42
±33
20.0
12.0
9.0
7.0
±10.0
±6.0
±5.0
±4.0
20.0
12.0
9.0
7.0
±10.0
±6.0
±5.0
±4.0
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
(mA)
72
72
75
75
72
72
75
75
74
74
76
76
75
75
78
78
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
250
250
250
250
250
250
250
250
Derating Curve
Notes:
1. Output load regulation is specified for a load change of 10% to
100%.
2. These units should not be operated with a load under 10% of full
load. Operation at no-load may cause damage to the unit.
3. These converters will operate without external components.
However, when measuring output ripple, it is recommended that
an external ceramic
Input
Output
capacitor be placed
Vin
Vout
Capacitor
Capacitor
from the +Vout pin
to the -Vout pin for 5 VDC
4.7 µF
5 VDC 4.7 µF
single output units 12 VDC
2.2 µF
9 VDC 2.2 µF
and from each out12 VDC 1.0 µF
put to common for
15 VDC 0.47 µF
dual output units. An
input capacitor will enhance stability over temperature and input
line variations. Recommended capacitor values are given in the
table above.
For applications requiring very low output noise levels, a simple Pi
filter should be effective. Component values would depend upon
the application, but capacitor values of 4.7 µF and inductor
values of 10 µH are often sufficient.
4. Dual output units may be connected to provide a 10V, 18V, 24V
or 30 VDC output. To do this, connect the load across the positive
(+Vout) and negative (-Vout) outputs and float the output common
5. It is recommended that a fuse be used on the input of a power
supply for protection. See the Model Selection table above for the
correct rating.
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
1
2
5
6
7
+Vin
-Vin
-Vout
No Pin
+Vout
+Vin
-Vin
-Vout
Common
+Vout
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]