Melexis MLX90819 Relative integrated pressure sensor datasheet Datasheet

MLX90819
Relative Integrated Pressure Sensor Datasheet
1. Features and Benefits
3. Description

Fully integrated IC: MEMS, analog front
end, 16 bit microcontroller, analog back
end, voltage regulators, SENT driver
The MLX90819 is an integrated relative pressure sensor
delivering a ratiometric analog or digital (using the SENT
protocol) signal.

Ratiometric Analog and SENT outputs

Automotive temperature (-40°C to 150°C)

Automotive qualified beyond AECQ100

Automotive diagnostic features (clamping
levels, broken track diagnostics, multiple
internal fault diagnostics)
Use of an optimized architecture and a high density
CMOS technology imparts the MLX90819 with best in
class automotive EMC performance. A DSP based
architecture using a 16bit microcontroller provides
outstanding performance in terms of initial accuracy.
Glass pedestal for easy assembly and for
back side exposed configuration for higher
resistance to common automotive media

High accuracy and robust EMC
performance
DSP
G
M
U
X
A
D
Gain & Offset
temperature
compensation
Pressure Linearization
Programmable filter
Diagnostics Logic
Analog/
Digital
Regulator
D
RAM
EEP
ROM
Figure 1: Block Diagram
2. Application Examples

Mid pressure ranges (10..50bar)

Automotive oil (engine, transmissions)

Automotive HVAC

Automotive fuel line

Industrial applications
REVISION 3 – OCTOBER 20, 2016
3901090819
A
Rev. Pol.
&
OverVolt.
Gain
VDD
OUT
TX
ROM - F/W
Diagnostic
Signals
C
16
Piezoresistive
sensing element
Temperature
Sensor
12

The MLX90819 is mounted on a glass pedestal to ease the
assembly of the die at the customers being the ideal
solution for back side exposed pressure sensor
applications requiring high accuracy, high EMC
robustness, miniaturization and compliance to harsh
automotive environments (See application note 90819
Pressure Sensor Assembly Guidelines).
(SENT)
GND
MLX90819
Datasheet
Contents
1. Features and Benefits ................................................................................................................. 1
2. Application Examples ................................................................................................................. 1
3. Description ................................................................................................................................. 1
4. Ordering Information ................................................................................................................. 3
5. Functional Diagram .................................................................................................................... 4
6. Glossary of Terms ....................................................................................................................... 5
7. Bond Pads Location and Description ........................................................................................... 5
8. Absolute Maximum Ratings ........................................................................................................ 6
9. General Electrical Specifications ................................................................................................. 7
10. Pressure Accuracy Specifications............................................................................................... 8
11. Application Information............................................................................................................ 8
12. Die Dimensions......................................................................................................................... 9
13. Standard Information ............................................................................................................. 10
14. ESD Precautions...................................................................................................................... 10
15. Contact................................................................................................................................... 11
16. Disclaimer .............................................................................................................................. 11
REVISION 3 – OCTOBER 20, 2016
3901090819
Page 2 of 11
MLX90819
Datasheet
4. Ordering Information
Product
Temperature
Package
Option Code
Packing Form
Definition
MLX90819
L (-40°C to 150°C)
UF
EBA-000
WB
10 to 35 bar range with
electronic wafer map
MLX90819
L (-40°C to 150°C)
UF
EBA-001
WB
10 to 35 bar range inked
wafer
MLX90819
L (-40°C to 150°C)
UF
EBB-000
WB
30 to 50 bar range with
electronic wafer map
MLX90819
L (-40°C to 150°C)
UF
EBA-001
WB
30 to 50 bar range inked
wafer
Table 1: Ordering information
Legend:
Temperature Code:
L: from -40°C to 150°C
Package Code:
“UF” for saw wafer on foil
Option Code:
EBA-000: 10 to 35 bar application range with electronic wafer map
EBA-001: 10 to 35 bar application range inked wafer
EBB-000: 30 to 50 bar application range with electronic wafer map
EBB-001: 30 to 50 bar application range inked wafer
Packing Form:
“WB” for wafer box
Ordering Example:
“MLX90819LUF-EBA-000-WB”
For a sensor covering 10 to 35 bar pressure span in the application delivered as a saw
wafer on foil with an electronic wafer map.
REVISION 3 – OCTOBER 20, 2016
3901090819
Page 3 of 11
MLX90819
Datasheet
5. Functional Diagram
The pressure sensing element consists of a square diaphragm realized in the silicon chip by backside etching. The
diaphragm reacts to a pressure difference between the top and bottom side of the diaphragm. The internal str ain
increases, in particular at the border of the diaphragm. Here, the piezo -resistive elements have been implanted into
the silicon diaphragm, which act as a transducer.
The electronics front end amplifies the signal from the bridge, performs a coarse of fset compensation and an ADC
conversion. The DSP performs the compensations over temperature. Furthermore, the digital circuit provides some
filtering, the possibility to linearize the pressure signal and also implements the clamping function. The analog b ack
end consists of a 12 bit DAC and an output driver. This chip delivers an analog output proportional to the pressure or a
SENT output compliant with SAE J2716 spec dated January 2010.
A broken wire detection block allows actively driving the output to one of the rails in case of a broken supply or ground
connection. Extensive protection of the supply lines allows the MLX90819 to handle extreme overvoltage conditions
and is immune to severe external disturbances. Several diagnostic functions (over -voltage, under-voltage,
overpressure, under pressure detections) have been implemented on the 90819 and can be enabled by programming
EEPROM settings. Figure 2 describes MLX90819 block diagram.
Temperature
Sensor
G
M
U
X
A
D
D
Gain & Offset
temperature
compensation
Pressure Linearization
Programmable filter
Diagnostics Logic
A
Rev. Pol.
&
OverVolt.
Gain
VDD
OUT
TX
ROM - F/W
Diagnostic
Signals
C
16
Piezoresistive
sensing element
Analog/
Digital
Regulator
12
DSP
RAM
EEP
ROM
(SENT)
GND
Figure 2: MLX90819 block diagram
REVISION 3 – OCTOBER 20, 2016
3901090819
Page 4 of 11
MLX90819
Datasheet
6. Glossary of Terms
Bar
Pressure unit (1bar = 100kPa)
ADC
Analog to Digital Converter
DAC
Digital to
Analog Converter
VDD
TX
DSP
Digital Signal Processor
EMC
Electro Magnetic Compatibility
FSO
Full Span Output
SENT
Single Edge Nibble Transmission
TEST
VDD
TX
TEST
Table 2: Glossary of terms
7. Bond Pads Location and Description
The positions of the bond pads are shown Error!
are depicted in
SN Reference source not found. in Figure 3. The (X, Y) axes
SN
GND
OUT
GND
blue; they represent the basis of the Cartesian
coordinates
of
the
bond
pads
center
points.
SP
SP
VDD
VDD
TX
TEST
OUT
TX
TEST
Y
(0,0)
SN
SP
GND OUT
X
SN
SP
GND OUT
Figure 3: Bond Pads Location
2650
2650
The bond pad coordinates and their names and functional type are given in table 3.
REVISION 3 – OCTOBER 20, 2016
3901090819
Page 5 of 11
MLX90819
Datasheet
Coordinates
XY
(1)
Pad Opening
X, Y
Pin
Type
Comment
VDD
Supply
470
2345
100
150
TX
Output
612
2370
100
100
To be connected in SENT mode
TEST
Input
86
1914
95
95
Do Not Connect
SN
Output
80
325
80
120
Do Not Connect
SP
Output
80
163
80
120
Do Not Connect
GND
Ground
1070
91
150
100
OUT
Output
1397
91
100
100
To be connected in Analog Mode
Table 3: Bond pad coordinates
8. Absolute Maximum Ratings
Parameter
Symbol
Max.
Unit
VDD
+18
V
VDDREV
-14
V
(2)
+18
V
(2)
-0.5
V
Operating Temperature Range
-40 to 150
°C
Storage Temperature Range
-40 to 150
°C
PBURST
70
140
Bar
PPROOF
60
100
Bar
Supply Voltage
(2)
Reverse Supply Voltage
(3)
Positive Output Voltage
Reverse Output Voltage
Burst Pressure @ Room Temperature
For EBA
For EBB
Proof Pressure @ Room Temperature
For EBA
For EBB
Table 4: Absolute maximum ratings
Exceeding the absolute maximum ratings may cause permanent damage.
conditions for extended periods may affect device reliability.
1
2
3
Exposure to absolute maximum-rated
Coordinate of the center of the pad.
No time limit or temperature limit for these over voltage conditions
Reverse Voltage Protection at -14V at 150 C for maximum 1 hour. At Room Temperature that condition can apply for maximum 24 hours
REVISION 3 – OCTOBER 20, 2016
3901090819
Page 6 of 11
MLX90819
Datasheet
9. General Electrical Specifications
DC Operating Parameters T = -40°C to 150°C, VDD = 5V (unless otherwise specified)
Parameter
Nominal Supply Voltage
Symbol
VDD
Test Conditions
Nominal Supply Current
IDD
No output load connected
Load Resistance
RLOAD
Pull-up or Pull-down
Capacitive Load
CLOAD
Diagnostic Limits
diag_lo
Clamping Levels
Analog Saturation Output
Level
Max
5.5
Units
V
8
mA
kΩ
4.7
470
nF
2
%VDD
clamp_lo
25
%VDD
clamp_hi
50
100
%VDD
0
2
%VDD
97
vsat_lo
vsat_hi
Power Up Time
7
2.2
Pull-up ≥ 4.7kΩ
Pull-up ≥ 4.7kΩ
Pull-up ≥ 10kΩ
(4)
Typ
5
96
98
0
diag_hi
(5)
Min
4.5
Depending on the load
configuration
%VDD
100
%VDD
(6)
5.5
ms
(7)
1
ms
0.2
%VDD
2
mVrms
1.8
LSBrms
Response Time
Ratiometricity Error
Analog Output noise
SENT Output noise
(8)
(8)
Table 5: General electrical specification
4Typical
values are defined at T A = +25ºC and V DD = 5V
5
Programmable range with 8 bits resolution for the low clamping level and 9 bits resolution for the high clamping level (See application note 90819
Advanced Configuration Settings for detailed information)
6
Time from reaching the minimum allowed supply voltage of 4.5V till having the output within specification
7
Time needed for the output to react to a pressure change from 10% to 90% of its final value (pressure change corresponding to maximum a 4V
output change) using default filter settings SSF=1, PFLT = 0 (See application note 90819 Advanced Configuration Settings for detailed inform ation)
8
Bandwidth limited to 50kHz. Using default filter settings SSF = 1, PFLT = 0.
REVISION 3 – OCTOBER 20, 2016
3901090819
Page 7 of 11
MLX90819
Datasheet
10. Pressure Accuracy Specifications
DC Operating Parameters T = -40°C to 150°C, VDD = 5V (unless otherwise specified)
Parameter
Non Linearity Error
Symbol
(9)
Test Conditions
EBA
Room Temperature
10 bar (2 point calibration)
35 bar (2 point calibration)
EBB
Room Temperature
30 bar (2 point calibration)
50 bar (2 point calibration)
Min
Hysteresis
Programmable Pressure
Spans
EBA
EBB
(10)
Overall Accuracy
Max
Units
0.1
0.2
%FSO
-0.25
0.1
0.2
0.25
10
30
-2.5
35
50
2.5
%FSO
%FSO
Bar
%FSO
Table 6: Pressure accuracy specification
11. Application Information
The MLX90819 only needs 2 capacitors in the application, a 47nF decoupling capacitor on the supply line and a 47nF load on
the analog output pin. When the SENT output is used a 2.2nF capacitor is recommended. Consult Melexis to discuss the ideal
application schematics depending on the EMC specs to be fulfilled.
MLX90819 in analog mode
Vdd
47nF
Gnd
47nF
AnaOut
Figure 4: MLX90819 application schematic - analog
9
Best Fit Non Linearity using ceramics prototype package.
Indicative overall accuracy using ceramics prototype package and calibration in engineering setup of EBA at 20bar and EBB at 50bar.
10
REVISION 3 – OCTOBER 20, 2016
3901090819
Page 8 of 11
MLX90819
Datasheet
MLX90819 in SENT mode
2.2nF
SENTOut
(TX)
Vdd
47nF
Gnd
Figure 5: MLX90819 application schematic - SENT
12. Die Dimensions
The MLX90819 shall be delivered as bare die, on fully tested wafers. Each wafer is accompanied by a wafer map in order to
discriminate between good and bad die during customer assembly. The die dimensions (including scribe lane), membrane
size are depicted in Figure 6. All dimensions are in mm.
Die Dimension excluding scribe lane
TYP
0 .780
Die Dimension including scribe lane (after dicing)
TYP < 0 .1
2 . 555
± 0 . 05
TYP 0 .55
1 .05
± 0 .05
TYP < 0 . 1
0.8
±0.08
2.555 ± 0 .05
TYP 0 . 5
1.09
±0.08
Figure 6: Floorplan of a single die, including central position of membrane
REVISION 3 – OCTOBER 20, 2016
3901090819
Page 9 of 11
MLX90819
Datasheet
13. Standard Information
Our products are classified and qualified regarding soldering technology, solderability and moisture sensitivity level
according to standards in place in Semiconductor industry.
For further details about test method references and for compliance verification of selected soldering method for
product integration, Melexis recommends reviewing on our web site the General Guidelines soldering
recommendation. For all soldering technologies deviating from the one mentioned in above document (regarding peak
temperature, temperature gradient, temperature profile etc), additional class ification and qualification tests have to
be agreed upon with Melexis.
For package technology embedding trim and form post-delivery capability, Melexis recommends to consult the
dedicated trim&form recommendation application note: lead trimming and forming recommendations
Melexis is contributing to global environmental conservation by promoting lead free solutions. For more information
on qualifications of RoHS compliant products (RoHS = European directive on the Restriction Of the use of certain
Hazardous Substances) please visit the quality page on our website: http://www.melexis.com/en/quality-environment
14. ESD Precautions
Electronic semiconductor products are sensitive to Electro Static Discharge (ESD).
Always observe Electro Static Discharge control procedures whenever handling semiconductor products.
REVISION 3 – OCTOBER 20, 2016
3901090819
Page 10 of 11
MLX90819
Datasheet
15. Contact
For the latest version of this document, go to our website at www.melexis.com.
For additional information, please contact our Direct Sales team and get help for your specific needs:
Europe, Africa
Telephone: +32 13 67 04 95
Email : [email protected]
Americas
Telephone: +1 603 223 2362
Email : [email protected]
Asia
Email : [email protected]
16. Disclaimer
The information furnished by Melexis herein (“Information”) is believed to be correct and accurate. Melexis disclaims (i) any and all liability in connection with or arising out of the
furnishing, performance or use of the technical data or use of the product(s) as described herein (“Product”) (ii) any and all liability, including without limitation, special,
consequential or incidental damages, and (iii) any and all warranties, express, statutory, implied, or by description, includ ing warranties of fitness for particular purpose, noninfringement and merchantability. No obligation or liability shall arise or flow out of Melexis’ rendering of technical or other services.
The Information is provided "as is” and Melexis reserves the right to change the Information at any time and without notice. Therefore, before placing orders and/or prior to
designing the Product into a system, users or any third party should obtain the latest version of the relevant information to verify that the information being relied upon is current.
Users or any third party must further determine the suitability of the Product for its application, including the level of reliability required and determine whether it is fit for a
particular purpose.
The Information is proprietary and/or confidential information of Melexis and the use thereof or anything described by the In formation does not grant, explicitly or implicitly, to
any party any patent rights, licenses, or any other intellectual property rights.
This document as well as the Product(s) may be subject to export control regulations. Please be aware that export might require a prior authorization from competent authorities.
The Product(s) are intended for use in normal commercial applications. Unless otherwise agreed upon in writing, the Product(s) are not designed, authorized or warranted to be
suitable in applications requiring extended temperature range and/or unusual environmental requirements. High reliability applications, such as medical life-support or lifesustaining equipment are specifically not recommended by Melexis.
The Product(s) may not be used for the following applications subject to export control regulations: the development, product ion, processing, operation, maintenance, storage,
recognition or proliferation of 1) chemical, biological or nuclear weapons, or for the development, production, maintenance o r storage of missiles for such weapons: 2) civil
firearms, including spare parts or ammunition for such arms; 3) defense related products, or other material for military use or for law enforcement; 4) any applications that, alone
or in combination with other goods, substances or organisms could cause serious harm to persons or goods and that can be used as a means of violence in an armed conflict or any
similar violent situation.
The Products sold by Melexis are subject to the terms and conditions as specified in the Terms of Sale, which can be found at https://www.melexis.com/en/legal/terms-andconditions.
This document supersedes and replaces all prior information regarding the Product(s) and/or previous versions of this document.
Melexis NV © - No part of this document may be reproduced without the prior written consent of Melexis. (2016)
ISO/TS 16949 and ISO14001 Certified
REVISION 3 – OCTOBER 20, 2016
3901090819
Page 11 of 11
Similar pages