Dc HS05MFL Technical specifications of surface mount glass passivated rectifier voltage range - 50 to 1000 volt Datasheet

HS05JFL
THRU
HS05MFL
DC COMPONENTS CO., LTD.
R
RECTIFIER SPECIALISTS
TECHNICAL SPECIFICATIONS OF SURFACE MOUNT GLASS PASSIVATED RECTIFIER
VOLTAGE RANGE - 50 to 1000 Volts
CURRENT - 0.5 Ampere
FEATURES
*
*
*
*
*
*
ldeal for surface mounted applications
Low leakage current
Low profile space
Low forward voltage drop
High forward surge capability
Glass passivated junction
SOD-123FL
.154(3.9)
.138(3.5)
MECHANICAL DATA
.115(2.9)
.098(2.5)
* Case: Molded plastic
* Epoxy: UL 94V-0 rate flame retardant
*Terminals: Solder plated, solderable per
MIL-STD-750, Method 2026
* Polarity: As marked
* Mounting position: Any
* Weight: 0.017 gram
.039(1.0)
.024(0.6)
.075(1.9)
.063(1.6)
.047(1.2)
.031(0.8)
.010(0.25)
.002(0.05)
.043(1.1)
.020(0.5)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
SYMBOL
Maximum Recurrent Peak Reverse Voltage
VRRM
Maximum RMS Voltage
VRMS
Maximum DC Blocking Voltage
VDC
Maximum Average Forward Rectified Current
Peak Forward Surge Current I FM(surge): 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage at 0.5A DC
Maximum DC Reverse Current at
Rated DC Blocking Voltage
@T A = 25 o C
@T A = 125 o C
Typical Thermal Resistance (Note 1)
Operating and Storage Temperature Range
NOTES :1. Mounted on FR-4 P.C.B. with 0.9X1.5 mm copper pads areas.
HS05JFL
600
420
600
HS05KFL
800
HS05MFL
1000
560
800
700
1000
UNITS
Volts
Volts
Volts
IO
0.3
Amps
I FSM
20
Amps
VF
Volts
RθJA
1.1
2.0
50
220
T J , T STG
-55 to + 150
IR
uAmps
0
C/ W
0
C
FIG. 1 - TYPICAL FORWARD CURRENT
DERATING CURVE
.5
.4
.3
.2
Single Phase
Half Wave 60Hz
Resistive or
Inductive Load
.1
0
0
25 50
75 100 125 150
AMBIENT TEMPERATURE, ( C)
175
O
FIG. 2 - MAXIMUM NON-REPETITIVE FOREARD
SURGE CURRENT
PEAK FORWARD SURGE CURRENT, (A)
AVERAGE FORWARD CURRENT, (A)
RATING AND CHARACTERISTIC CURVES (HS05JFL THRU HS05MFL)
10
1.0
O
TJ = 25 C
.1
Pulse Width = 300us
1% Duty Cycle
.01
.4
.6
.8
1.0
1.2
1.4
1.6
INSTANTANEOUS FORWARD VOLTAGE, (V)
20
15
10
5
8.3ms Single Half Sine-Wave
(JEDEC Method)
0
1
2
100
TJ= 125oC
10
1.0
TJ= 75oC
.01
TJ= 25oC
0.01
10
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
DC COMPONENTS CO., LTD.
R
4 6 8 10
20
40 60 80 100
NUMBER OF CYCLES AT 60Hz
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
INSTANTANEOUS REVERSE CURRENT, (uA)
INSTANTANEOUS FORWARD CURRENT, (A)
FIG. 3 - TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
25