TI CD74ACT05M Hex inverters with open-drain output Datasheet

CD54ACT05,, CD74ACT05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
www.ti.com
SCHS311C – JANUARY 2001 – REVISED JANUARY 2007
FEATURES
•
•
•
•
•
CD54ACT05 . . . F PACKAGE
CD74ACT05 . . . E OR M PACKAGE
(TOP VIEW)
Inputs Are TTL-Voltage Compatible
Speed of Bipolar F, AS, and S, With
Significantly Reduced Power Consumption
Fanout to 15 F Devices
SCR-Latchup-Resistant CMOS Process and
Circuit Design
Exceeds 2-kV ESD Protection Per
MIL-STD-883, Method 3015
1A
1Y
2A
2Y
3A
3Y
GND
1
14
2
13
3
12
4
11
5
10
6
9
7
8
VCC
6A
6Y
5A
5Y
4A
4Y
DESCRIPTION/ORDERING INFORMATION
The 'ACT05 devices contain six independent inverters. These devices perform the Boolean function Y = A. The
open-drain outputs require pullup resistors to perform correctly, and can be connected to other open-drain
outputs to implement active-low wired-OR or active-high wired-AND functions.
ORDERING INFORMATION
PACKAGE (1)
TA
PDIP – E
–55°C to 125°C
SOIC – M
CDIP – F
(1)
ORDERABLE PART NUMBER
Tube of 25
CD74ACT05E
Tube of 50
CD74ACT05M
Reel of 2500
CD74ACT05M96
Reel of 1000
CD54ACT05F3A
TOP-SIDE MARKING
CD74ACT05E
ACT05M
CD54ACT05F3A
Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at
www.ti.com/sc/package.
FUNCTION TABLE
(EACH INVERTER)
INPUT
A
A
OUTPUT
Y
H
L
L
Z
Y
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2001–2007, Texas Instruments Incorporated
On products compliant to MIL-PRF-38535, all parameters are
tested unless otherwise noted. On all other products, production
processing does not necessarily include testing of all parameters.
CD54ACT05,, CD74ACT05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
www.ti.com
SCHS311C – JANUARY 2001 – REVISED JANUARY 2007
Absolute Maximum Ratings (1)
over operating free-air temperature range (unless otherwise noted)
MIN
MAX
–0.5
6
UNIT
VCC
Supply voltage range
IIK
Input clamp current (2)
VI < 0 or VI > VCC
±20
mA
IOK
Output clamp current (2)
VO < 0
–50
mA
IO
Continuous current
±50
mA
θJA
Package thermal impedance (3)
Tstg
Storage temperature range
(1)
(2)
(3)
E package
80
M package
86
–65
V
°C/W
150
°C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
The input and output negative voltage ratings may be exceeded if the input and output current ratings are observed.
The package thermal impedance is calculated in accordance with JESD 51-7.
Recommended Operating Conditions (1)
TA = 25°C
–40°C TO
85°C
–55°C TO
125°C
MIN
MAX
MIN
MAX
MIN
MAX
4.5
5.5
4.5
5.5
4.5
5.5
VCC
Supply voltage
VIH
High-level input voltage
VIL
Low-level input voltage
VI
Input voltage
0
VCC
0
VCC
VO
Output voltage
0
5.5
0
5.5
IOL
Low-level output current
24
24
∆t/∆v
Input transition rise or fall rate
10
10
(1)
2
2
UNIT
V
2
0.8
V
0.8
0.8
V
0
VCC
V
0
5.5
V
24
mA
10
ns/V
All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
Electrical Characteristics
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
VOL
II
ICC
∆ICC
TEST CONDITIONS
VI = VIH or VIL
VCC
TA = 25°C
–40°C TO
85°C
–55°C TO
125°C
MIN
MIN
MIN
2
MAX
IOL = 50 mA
4.5 V
0.1
0.1
IOL = 24 mA
4.5 V
0.36
0.44
IOL = 50 mA (1)
5.5 V
IOL = 75 mA (1)
5.5 V
UNIT
MAX
0.1
0.5
1.65
V
1.65
VI = VCC or GND
5.5 V
±0.1
±1
±1
VI = VCC or GND, IO = 0
5.5 V
4
40
80
µA
2.4
2.8
3
mA
10
10
10
pF
VI = VCC– 2.1 V
4.5 V to 5.5 V
Ci
(1)
MAX
µA
Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage
to minimize power dissipation. Test verifies a minimum 50-Ω transmission-line drive capability at 85°C and 75-Ω transmission-line drive
capability at 125°C.
Submit Documentation Feedback
CD54ACT05,, CD74ACT05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
www.ti.com
SCHS311C – JANUARY 2001 – REVISED JANUARY 2007
ACT INPUT LOAD TABLE
(1)
Input
Unit Load
A
0.18
(1)
Unit load is ∆ICC limit specified in
electrical characteristics table
(e.g., 2.4 mA at 25°C).
Switching Characteristics
over recommended operating free-air temperature range, VCC = 5 V ± 0.5 V, CL = 50 pF (unless otherwise noted) (see
Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
A or B
Y
tPZL
tPLZ
–40°C TO
85°C
–55°C TO
125°C
MIN
MAX
MIN
2.4
8.5
2.3
9.3
2.8
9.8
2.7
10.8
UNIT
MAX
ns
Operating Characteristics
VCC = 5 V, TA = 25°C
PARAMETER
Cpd
Power dissipation capacitance
TYP
UNIT
105
pF
PARAMETER MEASUREMENT INFORMATION
2 × VCC
From Output
Under Test
CL = 50 pF
(see Note A)
R1 =
500 Ω†
S1
VCC
50% VCC
Input
50% VCC
0V
R2 = 500 Ω†
tPZL
tPLZ
≈VCC
50% VCC
Output
†
When VCC = 1.5 V, R1 = R2 = 1 kΩ
20% VCC
VOL
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
LOAD CIRCUIT
NOTES: A. CL includes probe and jig capacitance.
B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr ≤ 3 ns, tf ≤ 3 ns.
C. The outputs are measured one at a time, with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
Submit Documentation Feedback
3
PACKAGE OPTION ADDENDUM
www.ti.com
8-Nov-2006
PACKAGING INFORMATION
Orderable Device
Status (1)
Package
Type
Package
Drawing
Pins Package Eco Plan (2)
Qty
5962-9068601QCA
ACTIVE
CDIP
J
14
1
TBD
A42 SNPB
N / A for Pkg Type
CD54ACT05F3A
ACTIVE
CDIP
J
14
1
TBD
A42 SNPB
N / A for Pkg Type
CD74ACT05E
ACTIVE
PDIP
N
14
25
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
CD74ACT05EE4
ACTIVE
PDIP
N
14
25
Pb-Free
(RoHS)
CU NIPDAU
N / A for Pkg Type
CD74ACT05M
ACTIVE
SOIC
D
14
50
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
CD74ACT05M96
ACTIVE
SOIC
D
14
2500 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
CD74ACT05M96E4
ACTIVE
SOIC
D
14
2500 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
CD74ACT05ME4
ACTIVE
SOIC
D
14
CU NIPDAU
Level-1-260C-UNLIM
50
Green (RoHS &
no Sb/Br)
Lead/Ball Finish
MSL Peak Temp (3)
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in
a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check
http://www.ti.com/productcontent for the latest availability information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and
package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS
compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame
retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder
temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited
information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI
to Customer on an annual basis.
Addendum-Page 1
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications,
enhancements, improvements, and other changes to its products and services at any time and to
discontinue any product or service without notice. Customers should obtain the latest relevant information
before placing orders and should verify that such information is current and complete. All products are sold
subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent
TI deems necessary to support this warranty. Except where mandated by government requirements, testing
of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible
for their products and applications using TI components. To minimize the risks associated with customer
products and applications, customers should provide adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent
right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine,
or process in which TI products or services are used. Information published by TI regarding third-party
products or services does not constitute a license from TI to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or
other intellectual property of the third party, or a license from TI under the patents or other intellectual
property of TI.
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without
alteration and is accompanied by all associated warranties, conditions, limitations, and notices.
Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not
responsible or liable for such altered documentation.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for
that product or service voids all express and any implied warranties for the associated TI product or service
and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
Following are URLs where you can obtain information on other Texas Instruments products and application
solutions:
Products
Applications
Amplifiers
amplifier.ti.com
Audio
www.ti.com/audio
Data Converters
dataconverter.ti.com
Automotive
www.ti.com/automotive
DSP
dsp.ti.com
Broadband
www.ti.com/broadband
Interface
interface.ti.com
Digital Control
www.ti.com/digitalcontrol
Logic
logic.ti.com
Military
www.ti.com/military
Power Mgmt
power.ti.com
Optical Networking
www.ti.com/opticalnetwork
Microcontrollers
microcontroller.ti.com
Security
www.ti.com/security
Low Power Wireless
www.ti.com/lpw
Telephony
www.ti.com/telephony
Mailing Address:
Video & Imaging
www.ti.com/video
Wireless
www.ti.com/wireless
Texas Instruments
Post Office Box 655303 Dallas, Texas 75265
Copyright © 2007, Texas Instruments Incorporated