NEMA Contactors & Starters Freedom 33-79 February 2007 Catalog Number Selection Catalog Number Selection Table 33-91. Freedom Catalog Numbering System A N 1 4 A N 0 A 3E 005 Device Type C396 Electronic Overload FLA Range (FNVR & FVR Only) A = Starter C = Contactor Standard E = IEC N = NEMA Device Assembly Configuration 70 = Multi-Speed 1 = Non-reversing 5 = Reversing OLR Type 4 = Starter w/C396 Electronic Overload 5 = Contactor only — no overload relay 6 = Starter w/C306 Bi-Metal OLR 7 = Starter w/C316 Bi-Metal OLR 8 = Starter w/IT. SSOLR A= B= D= G= K= N= S= T= U= V= 00 0 1 2 3 4 5 6 7 8 Continuous Amp Rating 9 18 27 45 90 135 270 540 810 1215 Frame G — NEMA Size 2 008 = 1.6 – 8.0A 032 = 6.4 – 32A 045 = 9.0 – 45A Frame B — NEMA Size 0 P05 = 0.1 – 0.5A 002 = 0.4 – 2.0A 005 = 1.0 – 5.0A 008 = 1.6 – 8.0A 032 = 6.4 – 32A Frame K — NEMA Size 3 110 = 22 – 110A Frame D — NEMA Size 1 P05 = 0.1 – 0.5A 002 = 0.4 – 2.0A 005 = 1.0 – 5.0A 008 = 1.6 – 8.0A 032 = 6.4 – 32A Frame T — NEMA Size 6 600 = 120 – 600A Frame S — NEMA Size 5 300 = 60 – 300A Frame U — NEMA Size 7 10C = 200 – 1000A Frame V — NEMA Size 8 15C = 300 – 1500A Standard C396 OLR, SEL Reset, SEL Class C= B= N/R = B= C= B= NEMA Size 00, 0 NEMA Size 1, 2 NEMA Size 3, 4 NEMA Size 5 NEMA Size 6 NEMA Size 7, 8 C306 Bi-Metallic OLR Designation N = Open For Starters Starter Mounting Option 0= V= Horizontal Vertical For Contactors Only 2-pole 3-pole 4-pole 5-pole AC Coil Suffix Suffix Coil Volts and Hertz A= B= C= D= 120/60 or 110/50 240/60 or 220/50 480/60 or 440/50 600/60 or 550/50 E= H= J= K= 208/60 277/60 208 – 240/60 240/50 L= N= T= U= 380 – 415/50 550/50 24/60, 24/50 24/50 V= W= Y= 32/50 48/60 48/50 For Contactor Only orders, add B to end of Catalog Number if NEMA Size 00 – 2, 6. 3E, 4E feature set only. Uses CT with C396 45 mm OLR, 3E, 4E feature set only. Not required. NEMA Sizes 00 and 0 only. NEMA Sizes 00 and 0 only. Sizes 1 – 8 are 24/60 only. CA08102001E Frame N — NEMA Size 4 150 = 30 – 150A 3E = NEMA Enclosure 2= 3= 4= 5= Frame A — NEMA Size 00 P05 = 0.1 – 0.5A 002 = 0.4 – 2.0A 005 = 1.0 – 5.0A 008 = 1.6 – 8.0A C396 Electronic OLR Designation (FVNR & FVR Only) Contactor Frame Size NEMA Size 33 For more information visit: www.eaton.com NEMA Contactors & Starters Freedom 33-85 February 2007 Starters — 3-Phase Non-reversing and Reversing, Full Voltage, Bi-Metallic Overload Product Selection When Ordering Supply ■ ■ Catalog Number Heater pack number (see selection table, Pages 33-117 – 33-118) or full load current. Size 0 Non-reversing Starter Size 3 Vertical Reversing Starter Size 1 Reversing Starter Table 33-101. Type AN16/AN56 NEMA — Manual or Automatic Reset Overload Relay — Non-reversing and Reversing Maximum UL Horsepower NEMA Continuous Service-Limit Current Size Ampere Rating Rating (Amperes) 00 9 11 0 18 21 1-Phase 115V 230V 208V 1/3 1 3-Pole Non-reversing 3-Phase 240V 480V 600V Catalog Number Price U.S. $ 3-Pole Reversing Vertical Reversing Catalog Number Catalog Number 1 1-1/2 1-1/2 2 2 AN16AN0_C AN56AN0_C — 2 3 3 5 5 AN16BN0_C AN56BN0_C AN56BNV0_ AN56DNV0_ 1 27 32 2 3 10 10 AN16DN0_B AN56DN0_B 2 45 52 3 7-1/2 10 15 25 25 AN16GN0_B AN56GN0_B AN56GNV0_ 3 90 104 — — 25 30 50 50 AN16KN0_ AN56KN0_ AN56KNV0_ 4 135 156 — — 40 50 100 100 AN16NN0_ AN56NN0_ AN56NNV0_ 5 270 311 — — 75 100 200 200 AN16SN0_B AN56SN0_B — 6 540 621 — — 150 200 400 400 AN16TN0_C AN56TN0_C — 7 810 932 — — 200 300 600 600 AN16UN0_B AN56UN0_B — 1215 1400 — — 400 450 900 900 AN16VN0_B AN56VN0_B — 8 7-1/2 7-1/2 Price U.S. $ Note: Starter Catalog Numbers do not include heater packs. Select one carton of three heater packs. Heater pack selection, Pages 33-117 – 33-118. Underscore (_) indicates coil suffix required, see Table 33-102. Maximum horsepower rating of starters for 380V 50 Hz applications: NEMA Size 00 0 1 2 3 4 5 6 7 8 Horsepower 1-1/2 5 10 25 50 75 150 300 600 900 The service-limit current ratings represent the maximum rms current, in amperes, which the controller shall be permitted to carry for protracted periods in normal service. At service-limit current ratings, temperature rises shall be permitted to exceed those obtained by testing the controller at its continuous current rating. The current rating of overload relays or trip current of other motor protective devices used shall not exceed the service-limit current rating of the controller. Common control. For separate 120V control, insert letter D in 7th position of listed Catalog Number. EXAMPLE: AN56VND0CB. Magnet Coils — AC or DC Starter coils listed in this section also have a 50 Hz rating as shown in the adjacent table. Select required starter by Catalog Number and replace the magnet coil alpha designation in the Catalog Number (_) with the proper Code Suffix from the adjacent table. NEMA Size 0 Cat. No. AN56BN0AC For Sizes 00 – 2 and 5 – 8, the magnet coil alpha designation will be the next to last digit of the listed Catalog Number. EXAMPLE: For a 380V, 50 Hz coil, change AN16BN0_C to AN16BN0LC. For all other sizes, the magnet coil alpha designation will be the last digit of the listed Catalog Number. For DC Magnet Coils, see Accessories, Pages 33-98 – 33-99. Table 33-102. AC Suffix Code Coil Volts and Hertz Code Suffix 120/60 or 110/50 240/60 or 220/50 480/60 or 440/50 600/60 or 550/50 A B C D 208/60 277/60 208 – 240/60 240/50 E H J K 380 – 415/50 550/50 24/60, 24/50 24/50 L N T U 32/50 48/60 48/50 NEMA Sizes 00 and 0 only. NEMA Sizes 00 and 0 only. Sizes 1 – 8 are 24/60 only. Technical Data. . . . . . . . . . Overload Relay . . . . . . . . . Dimensions . . . . . . . . . . . . Special Modifications . . . Accessories . . . . . . . . . . . . Heater Packs . . . . . . . . . . . Discount Symbol . . . . . . . . CA08102001E For more information visit: www.eaton.com V W Y Pages 33-89 – 33-91 Page 33-113 Pages 33-106 – 33-108 Page 33-100 Pages 33-92 – 33-100 Pages 33-117 – 33-118 1CD1 33 NEMA Contactors & Starters Freedom 33-117 February 2007 Relays — Thermal Overload Product Selection 33 75A Overload Cat. No. C306GN3B 75A Overload Cat. No. C306GT3B 32A Overload Cat. No. C306DT3B 32A Overload Cat. No. C306DN3B Table 33-168. C306 Thermal Overload Relays For Use with Freedom Series Contactors NEMA Size 00, 0 1, 2 3 4 5–8 Maximum Ampere Rating Number of Poles 32 75 105 144 — 3 3 3 3 — Open Type Catalog Number Number of Poles NEMA Size Maximum Ampere Rating 00, 0, 1 1 3 4 5–8 32 75 105 144 — 3 3 3 3 — Catalog Number Price U.S. $ C306DG3B C306GG3B — NEMA Sizes 5 – 8 use the 32A overload in conjunction with CTs. Series B overload relays have load lugs built into relay base and will only accept Series B heater packs. These relays can be directly attached to contactor or they can be DIN rail or panel mounted using adapter on Page 33-115. These relays can be panel mounted only. For Stand-Alone Applications Price U.S. $ C306DN3B C306GN3B C306KN3 C306NN3 — Heater Pack Selection Table 33-169. C306 Thermal Overload Relays NEMA 1 Enclosed Open Type Catalog Number Price U.S. $ C306DT3B C306GT3B C306KN3 C306NN3 — Overload relay assembled with mounting adapter for DIN rail or panel mount. Panel mount only. NEMA Sizes 5 – 8 use the 32A overload in conjunction with CTs. Heater packs H2001B to H2017B and H2101B to H2117B are to be used only with Series B overload relays Catalog Numbers C306DN3B (Part No. 10-7016) and C306GN3B (Part No. 10-7020). The load lugs are built into the overload relay base to allow load wiring prior to heater pack installation. The previous heater design had integral load lugs. The Series B heater packs are electrically equivalent to the previous heater design. Heaters H2018-3 to H2024-3 have not changed. Table 33-170. Starters with Series B Overload Relays NEMA — AN Type IEC — AE Type Size Series Size Series 00 – 0 1–2 5 6 7–8 C B B C B A–F G–K C B Note: The series of a starter is the last digit of the listed Catalog Number. EXAMPLE: AN16DN0AB. Heater Pack H2001B – H2017B Heater Pack H2101B – H2117B Heater Pack H2018 – H2024 Technical Data . . . . . . . . Dimensions . . . . . . . . . . . . Replacement Parts . . . . . Discount Symbol . . . . . . . CA08102001E For more information visit: www.eaton.com Page 33-114 Page 33-116 Pages 33-115 – 33-116 1CD1C NEMA Contactors & Starters Freedom 33-118 February 2007 Relays — Thermal Overload Table 33-171. Standard Trip — Class 20 Heater Selection Overload Relay Size 33 Motor Full Load Ampere Rating Catalog Number (Includes 3 Heater Packs) Dial Position A B C D Table 33-172. Fast Trip — Class 10 Heater Selection Price U.S. $ For Use with NEMA Sizes 00 – 0 Series C, NEMA Sizes 1 – 2 Series B; IEC Sizes A – F Series C, IEC Sizes G – K Series B 32A or 75A .254 .375 .560 .814 1.20 .306 .452 .676 .983 1.45 .359 .530 .791 1.15 1.71 1.79 2.15 3.23 4.55 6.75 2.16 2.60 3.90 5.50 8.17 2.53 3.04 4.56 6.45 9.58 9.14 14.0 18.7 23.5 10.8 16.9 22.7 28.5 12.4 19.9 26.7 33.5 .411 .607 .907 1.32 1.96 H2001B-3 H2002B-3 H2003B-3 H2004B-3 H2005B-3 29.0 39.6 53.9 34.0 45.5 60.9 39.1 51.5 67.9 11.5 15.7 19.0 24.5 33.4 H2025-3 H2026-3 H2027-3 H2018-3 H2019-3 33.5 45.7 62.2 84.7 106.0 37.5 51.2 69.7 95.0 118.0 41.5 56.7 77.1 105.0 131.0 45.6 62.1 84.6 115.0 144.0 H2020-3 H2021-3 H2022-3 H2023-3 H2024-3 79 118 174 209 — H2004B-3 H2005B-3 H2006B-3 H2007B-3 H2008B-3 For Use with Size 6 Starters Only — Series B and IEC T – V with 600/5 CT 32A 144 215 258 388 174 259 312 468 205 304 365 547 235 348 419 627 H2005B-3 H2006B-3 H2007B-3 H2008B-3 75A 163 240 358 430 646 197 290 432 520 780 230 342 506 608 912 .313 .464 .688 1.02 1.55 2.33 2.79 4.10 6.03 8.58 264 392 580 698 — 11.2 17.5 21.8 27.3 .367 .543 .806 1.20 1.83 .420 .623 .924 1.37 2.10 H2101B-3 H2102B-3 H2103B-3 H2104B-3 H2105B-3 2.74 3.28 4.82 7.09 10.1 3.15 3.77 5.54 8.16 11.6 H2106B-3 H2107B-3 H2108B-3 H2109B-3 H2110B-3 12.8 20.7 25.0 31.0 14.4 23.8 28.1 34.8 H2111B-3 H2112B-3 H2113B-3 H2114B-3 H2004B-3 H2005B-3 H2006B-3 H2007B-3 H2008B-3 28.3 36.6 53.8 32.6 42.3 60.8 37.0 48.1 67.9 41.3 53.8 74.9 H2115B-3 H2116B-3 H2117B-3 For Use with Size 5 Starters Only — Series B and IEC P, R and S with 300/5 CT 32A 51 77 115 138 203 61 93 140 167 246 72 110 164 197 289 82 126 189 226 — H2104B-3 H2105B-3 H2106B-3 H2107B-3 H2108B-3 For Use with Size 6 Starters Only — Series B and IEC T – V with 600/5 CT 32A 154 230 276 406 186 280 335 492 220 329 394 578 252 378 452 — H2105B-3 H2106B-3 H2107B-3 H2108B-3 For Use with Size 7 Starters Only — Series B and IEC W – X with 1000/5 CT 32A 169 256 384 460 676 204 310 466 558 820 240 366 543 656 — 274 420 630 754 — H2104B-3 H2105B-3 H2106B-3 H2107B-3 H2108B-3 For Use with Size 8 Starters Only — Series B and IEC Z with 1500/5 CT 32A For Use with Size 7 Starters Only — Series B and IEC W – X with 1000/5 CT 32A D Price U.S. $ For Use with NEMA Size 2, IEC Sizes G – K Only — Series B H2015B-3 H2016B-3 H2017B-3 10.3 14.3 17.4 22.3 30.5 69 103 152 182 274 C .260 .384 .570 .846 1.28 9.60 14.4 18.7 23.5 9.2 12.8 15.7 20.2 27.6 59 87 130 156 234 32A or 75A H2011B-3 H2012B-3 H2013B-3 H2014B-3 44.1 57.4 74.9 Catalog Number (Includes 3 Heater Packs) For Use with NEMA Sizes 00 – 0 Series C, NEMA Sizes 1 – 2 Series B; IEC Sizes A – F Series C, IEC Sizes G – K Series B 14.0 22.8 30.7 38.5 8.0 11.4 14.3 18.0 24.6 49 72 107 129 194 B 1.92 2.30 3.38 4.96 7.07 For Use with Size 5 Starters — Series B and IEC P, R and S with 300/5 CT 32A A H2006B-3 H2007B-3 H2008B-3 H2009B-3 H2010B-3 For Use with NEMA Sizes 3 – 4, IEC Sizes L – N Only — Series A 105A or 144A Motor Full Load Ampere Rating Dial Position 2.90 3.49 5.23 7.40 11.0 For Use with NEMA Size 2, IEC Sizes G – K Only — Series B 75A Overload Relay Size 254 384 576 690 1014 306 465 699 837 1230 360 549 822 984 — 411 630 945 1131 — H2104B-3 H2105B-3 H2106B-3 H2107B-3 H2108B-3 Heater packs are shipped 3 to a carton. Catalog Numbers are for 3 heater packs. Sizes 5 – 8 and IEC P – Z use the 32A overload relay with current transformers. For Use with Size 8 Starters Only — Series B and IEC Z with 1500/5 CT 32A 244 360 537 645 969 295 435 648 780 1170 345 513 759 912 1368 396 588 870 1047 — H2004B-3 H2005B-3 H2006B-3 H2007B-3 H2008B-3 Heater packs are shipped 3 to a carton. Catalog Numbers are for 3 heater packs. Sizes 5 – 8 and IEC P – Z use the 32A overload relay with current transformers. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C For more information visit: www.eaton.com CA08102001E