Data Delay DDU8C-5075 5-tap, hcmos-interfaced fixed delay line Datasheet

DDU8C
data 3 
delay
devices, inc.
5-TAP, HCMOS-INTERFACED
FIXED DELAY LINE
(SERIES DDU8C)
FEATURES
•
•
•
•
•
•
PACKAGES
Five equally spaced outputs
Fits standard 8-pin DIP socket
Low profile
Auto-insertable
Input & outputs fully CMOS interfaced & buffered
10 T2L fan-out capability
IN
1
8
VDD
T2
2
7
T1
T4
3
6
T3
GND
4
5
T5
DDU8C-xx
DDU8C-xxA1
DDU8C-xxB1
DDU8C-xxM
IN
N/C
N/C
T2
N/C
T4
GND
DIP
Gull-Wing
J-Lead
Military DIP
1
2
3
4
5
6
7
14
13
12
11
10
9
8
VDD
N/C
T1
N/C
T3
N/C
T5
Military SMD
DDU8C-xxMD1
DDU8C-xxMD4
FUNCTIONAL DESCRIPTION
PIN DESCRIPTIONS
The DDU8C-series device is a 5-tap digitally buffered delay line. The
signal input (IN) is reproduced at the outputs (T1-T5), shifted in time by an
amount determined by the device dash number (See Table). The total
delay of the line is measured from IN to T5. The nominal tap-to-tap delay
increment is given by one-fifth of the total delay.
IN
T1-T5
VDD
GND
Signal Input
Tap Outputs
+5 Volts
Ground
SERIES SPECIFICATIONS
DASH NUMBER SPECIFICATIONS
•
•
•
•
Part
Number
DDU8C-5050
DDU8C-5060
DDU8C-5075
DDU8C-5100
DDU8C-5125
DDU8C-5150
DDU8C-5175
DDU8C-5200
DDU8C-5250
•
•
Minimum input pulse width: 40% of total delay
Output rise time: 8ns typical
Supply voltage: 5VDC ± 5%
Supply current: ICCL = 40µa typical
ICCH = 10ma typical
Operating temperature: 0° to 70° C
Temp. coefficient of total delay: 300 PPM/°C
Total
Delay (ns)
50 ± 2.5
60 ± 3.0
75 ± 4.0
100 ± 5.0
125 ± 6.5
150 ± 7.5
175 ± 8.0
200 ± 10.0
250 ± 12.5
Delay Per
Tap (ns)
10.0 ± 3.0
12.0 ± 3.0
15.0 ± 3.0
20.0 ± 3.0
25.0 ± 3.0
30.0 ± 3.0
35.0 ± 4.0
40.0 ± 4.0
50.0 ± 5.0
NOTE: Any dash number between 5004 and 5250
not shown is also available.
20%
VDD IN
20%
T1
20%
T2
20%
T3
20%
T4
T5 GND
DDU8C Functional diagram
1997 Data Delay Devices
Doc #97013
1/28/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
1
DDU8C
APPLICATION NOTES
Delay Devices if your application requires device
testing at a specific input condition.
HIGH FREQUENCY RESPONSE
The DDU8C tolerances are guaranteed for input
pulse widths and periods greater than those
specified in the test conditions. Although the
device will function properly for pulse widths as
small as 40% of the total delay and periods as
small as 80% of the total delay (for a symmetric
input), the delays may deviate from their values
at low frequency. However, for a given input
condition, the deviation will be repeatable from
pulse to pulse. Contact technical support at Data
POWER SUPPLY BYPASSING
The DDU8C relies on a stable power supply to
produce repeatable delays within the stated
tolerances. A 0.1uf capacitor from VDD to GND,
located as close as possible to the VDD pin, is
recommended. A wide VDD trace and a clean
ground plane should be used.
DEVICE SPECIFICATIONS
TABLE 1: ABSOLUTE MAXIMUM RATINGS
PARAMETER
DC Supply Voltage
Input Pin Voltage
Storage Temperature
Lead Temperature
SYMBOL
VDD
VIN
TSTRG
TLEAD
MIN
-0.3
-0.3
-55
MAX
7.0
VDD+0.3
150
300
UNITS
V
V
C
C
NOTES
10 sec
TABLE 2: DC ELECTRICAL CHARACTERISTICS
(0C to 70C, 4.75V to 5.25V)
PARAMETER
High Level Output Voltage
SYMBOL
VOH
Low Level Output Voltage
VOL
High Level Output Current
Low Level Output Current
High Level Input Voltage
Low Level Input Voltage
Input Current
IOH
IOL
VIH
VIL
IIH
Doc #97013
1/28/97
MIN
3.98
TYP
4.4
MAX
UNITS
V
0.15
0.26
V
-4.0
4.0
mA
mA
V
V
µA
3.15
1.35
0.10
NOTES
VDD = 5.0, IOH = MAX
VIH = MIN, VIL = MAX
VDD = 5.0, IOL = MAX
VIH = MIN, VIL = MAX
VDD = 5.0
DATA DELAY DEVICES, INC.
Tel: 973-773-2299
Fax: 973-773-9672
http://www.datadelay.com
2
DDU8C
PACKAGE DIMENSIONS
8
7
6
5
Lead Material:
Nickel-Iron alloy 42
TIN PLATE
8
1
2
3
7
6
5
.440
MAX.
4
.280
MAX.
.500 MAX.
1
2
3
4
.500 MAX.
.290
MAX.
.020 .290
TYP. MAX.
.015 TYP.
.010±.002
.018
TYP.
.070 MAX.
.180
TYP.
.350
MAX.
.300±.010
3 Equal spaces
each .100±.010
Non-Accumulative
.300
TYP.
.040
TYP.
8
7
6
.010 TYP.
.020
TYP.
5
2
3
7
6
.300
MAX.
.050
TYP.
DDU8C-xxA1 (Commercial Gull-Wing)
.320
TYP.
.270
TYP.
1
.110
.050 TYP.
5
.430
TYP.
4
.100
.300
.520 MAX.
.040
TYP.
8
.270
TYP.
1
.300
TYP.
DDU8C-xxM (Military DIP)
DDU8C-xx (Commercial DIP)
.020
TYP.
.010 TYP.
.020
TYP.
2
3
4
.100
.300
.520 MAX.
.110
.350
MAX.
.110
TYP.
DDU8C-xxB1 (Commercial J-Lead)
.650
.100
1
.100
.017
14
1
.510
MAX.
.300
TYP.
7
.510 MAX.
.300
.200 MAX. (Com)
.225 MAX. (Mil)
.065
TYP.
.008
.065
TYP.
DDU8C-xxD1 (Commercial SMD)
DDU8C-xxMD1 (Military SMD)
Doc #97013
1/28/97
8
.050
.510 MAX.
.080
.025
.360
TYP.
.510
MAX.
.100
.050
.045
.017
.300
TYP.
7
8
.100
.300
14
.200 MAX. (Com)
.225 MAX. (Mil)
.005
.080
.008
.360 TYP.
.065 TYP.
.065 TYP.
DDU8C-xxD4 (Commercial SMD)
DDU8C-xxMD4 (Military SMD)
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
3
DDU8C
DELAY LINE AUTOMATED TESTING
TEST CONDITIONS
INPUT:
Ambient Temperature: 25oC ± 3oC
Supply Voltage (VDD): 5.0V ± 0.1V
Input Pulse:
High = 5.0V ± 0.1V
Low = 0.0V ± 0.1V
Source Impedance:
50Ω Max.
Rise/Fall Time:
5.0 ns Max. (measured
between 0.5V and 4.5V )
Pulse Width:
PWIN = 1.5 x Total Delay
Period:
PERIN = 10 x Total Delay
OUTPUT:
Load:
Cload:
Threshold:
1 FAST-TTL Gate
5pf ± 10%
2.5V (Rising & Falling)
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
PRINTER
COMPUTER
SYSTEM
REF
PULSE
GENERATOR
OUT
IN
TRIG
DEVICE UNDER
TEST (DUT)
T1
IN
T2
TRIG
TIME INTERVAL
COUNTER
T3
T4
T5
Test Setup
PERIN
PWIN
TRISE
INPUT
SIGNAL
TFALL
VIH
4.5V
2.5V
0.5V
4.5V
2.5V
0.5V
TRISE
OUTPUT
SIGNAL
VIL
TFALL
VOH
2.5V
2.5V
VOL
Timing Diagram For Testing
Doc #97013
1/28/97
DATA DELAY DEVICES, INC.
Tel: 973-773-2299
Fax: 973-773-9672
http://www.datadelay.com
4