AIMTEC AM1LR-0512S-NZ Continuous short circuit protection Datasheet

Click on Series name for product info on aimtec.com
Series AM1LR-NZ
1 Watt | DC-DC Converter
FEATURES:
• Regulated output
• Continuous short circuit protection
• Efficiency up to 75%
• Operating temperature: -40oC to +85 oC
•
•
•
Isolation Voltage of 1500 & 3000VDC
Small SMD package
Universal industry pinout
Models
Single output
Model
AM1LR-0503S-NZ
AM1LR-0505S-NZ
AM1LR-0512S-NZ
AM1LR-0515S-NZ
AM1LR-1205S-NZ
AM1LR-1212S-NZ
AM1LR-1215S-NZ
AM1LR-2405S-NZ
AM1LR-2412S-NZ
AM1LR-2415S-NZ
Input Voltage
(V)
Output
Voltage
(V)
Output
Current (mA)
Isolation
(VDC)
Max Capacitive
Load (µF)
Efficiency
(%)
4.75-5.25
4.75-5.25
4.75-5.25
4.75-5.25
11.4-12.6
11.4-12.6
11.6-12.6
22.8-25.2
22.8-25.2
22.8-25.2
3.3
5
12
15
5
12
15
5
12
15
243
200
84
67
200
84
67
200
84
67
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
220
220
220
220
220
220
220
220
220
220
58
72
73
74
73
73
75
73
73
74
AM1LR-0503SH30-NZ
4.75-5.25
3.3
243
3000
220
58
AM1LR-0505SH30-NZ
4.75-5.25
5
200
3000
220
72
AM1LR-0512SH30-NZ
4.75-5.25
12
83
3000
220
73
AM1LR-0515SH30-NZ
4.75-5.25
15
67
3000
220
74
AM1LR-1205SH30-NZ
11.4-12.6
5
200
3000
220
73
AM1LR-1212SH30-NZ
11.4-12.6
12
83
3000
220
73
AM1LR-2405SH30-NZ
22.8-25.2
5
200
3000
220
73
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage Range
Absolute Max Input Voltage
(1 sec max)
Nominal
Typical
5
12
24
5 Vin
12 Vin
24 Vin
4.75-5.25
11.4-12.6
22.8-25.2
Filter
Quiescent Current
5
12
24
Input Reflected Ripple current
Maximum
Units
VDC
9
18
30
Capacitor
15
10
7
15
VDC
mA
mA
Isolation Specifications
Parameters
Tested I/O Voltage
Resistance
Capacitance
www.aimtec.com
F 051e R12
Conditions
60 sec, <1mA
500VDC
Typical
>1000
20
Tel: +1 514 620 2722
1 of 3
Rated
Units
1500 & 3000
VDC
MOhm
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1LR-NZ
1 Watt | DC-DC Converter
Output Specifications
Parameters
Voltage Accuracy
Short Circuit Protection
Short Circuit Restart
Line Voltage Regulation
Load Voltage Regulation
Temperature Coefficient
Ripple & Noise
Conditions
Typical
100% load (see tolerance chart)
Maximum
±3
Continuous
Auto-Recovery
±0.25
±3
±2
For ±1% of Vin
(10% - 100% Load) 3.3V
(10% - 100% Load) Other outputs
100% load
Units
%
% of Vin
%
±0.03
50
o
%/ C
mV p-p
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum Case temperature
Cooling
Storage Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Maximum case temperature
Conditions
Typical
Maximum
Units
100% load
With derating above +71
100
300
KHz
o
C
o
C
o
C
-40 to +85
-55 to +125
95
Free air convection
Non Condensing
95
Epoxy resin (UL94-V0)
2
0.60 x 0.44 x 0.28inches 15.24 x 11.20 x 7.25mm
o
>3,500,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25 C)hours
1.5mm from case for 10 sec
300
130
Pin Out Specifications
% RH
g
o
C
C
o
Dimensions
Front View
Pin
Dual Output
Models
1
2
3
4
5
6
7
8
9
10
-V Input
+V Input
No Pin
-V Output
-V Output
No Pin
+V Output
No Pin
No Pin
N.C.
7.62
(0.30)
Side View
7.00
(0.28)
0.25
(0.01)
0º~5º angle
1.50
(0.06)
Top View
15.2
(0.60)
7.62
(0.30)
All dimensions are in mm (inch)
All Pins are on a 2.54mm (0.10inch) pitch
with tolerance of ±0.25mm (0.01inch)
11.20 8.40
(0.44) (0.33)
1
2.54
(0.10)
www.aimtec.com
F 051e R12
0.50
(0.02)
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM1LR-NZ
1 Watt | DC-DC Converter
Derating
Free Air Convection
Input Reflected Ripple Current Test Circuit
71º C
Output Power (%)
100
80
L1
(4.7 µh)
Vin+
Safe Operating Area
60
Test
Point
Vo+
+
40
C1
(220 µf)
20
Vin-
0
- 40
Aimtec
DC-DC
Converter
- 20
0
20
40
60
80
85
Vo-
-
100
RL
(Full
Load)
* Tested at full load, and nominal input
Ambient Temperature º C
EMI Recommended Circuit (Class B)
LDM
6.8µH
C1
4.7µF/
50V
Output Capacitor (C2)
+V output
+V input
DC/DC
Converter
-V input
C2
Vout
(VDC)
Load
3.3 & 5
12
15
C2
(µF)
10
2.2
1
-V output
NOTE: 1.Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified.5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only