CPC1916 Power SIP Relay Parameter Blocking Voltage Load Current On-Resistance Rating 100 2.5 0.34 Description Units VP ADC/Arms Ω Clare and IXYS have combined to bring OptoMOS® technology, reliability, and compact size to a new family of high-power, solid state relays. As part of that family, the CPC1916 is a 1-Form-A solid state relay. The CPC1916 employs optically coupled MOSFET technology to provide 2500Vrms of input to output isolation. The efficient MOSFET switches and photovoltaic die use Clare’s patented OptoMOS architecture, while the output is controlled by a highly efficient GaAlAs infrared LED. The combination of low on-resistance and high load-current handling capabilities makes the relay suitable for a variety of high-performance switching applications. Features • • • • • • • • • Power SIP Package Handle Load Currents Up to 2.5ADC/Arms High Reliability No Moving Parts Low Drive Power Requirements (TTL/CMOS Compatible) Arc-Free With No Snubbing Circuits 2500Vrms Input/Output Isolation No EMI/RFI Generation Machine Insertable, Wave Solderable Approvals • UL Recognized Component: File # E69938 • Certified to: UL 508 Ordering Information Applications • • • • • Industrial Controls Motor Control Robotics Medical Equipment—Patient/Equipment Isolation Instrumentation • Multiplexers • Data Acquisition • Electronic Switching • I/O Subsystems • Meters (Watt-Hour, Water, Gas) • IC Equipment • Home Appliances Part # CPC1916Y Description Power SIP Package (25 per tube) Pin Configuration 1 - 2 + 3 4 Switching Characteristics of Normally Open (Form A) Devices Control ILOAD + 90% 10%+ Pb RoHS 2002/95/EC DS-CPC1916-R04 tOFF e3 tON www.clare.com 1 CPC1916 Absolute Maximum Ratings (@ 25˚ C) Parameter Blocking Voltage Reverse Input Voltage Input control Current Peak (10ms) Input Power Dissipation 1 Isolation voltage Input to Output Operational Temperature Storage Temperature 1 Ratings 100 5 50 1 150 2500 -40 to +85 -40 to +125 Units VP V mA A mW Vrms °C °C Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at conditions beyond those indicated in the operational sections of this data sheet is not implied. Derate Linearly 3.33 mw / ºC Electrical Characteristics Parameter Output Characteristics @ 25°C Load Current, Continuous Peak Load Current On-Resistance 1 Off-State Leakage Current Switching Speeds Turn-On Turn-Off Input Characteristics @ 25°C Input Control Current Input Dropout Current Input Voltage Drop Reverse Input Current Common Characteristics @ 25°C Capacitance Input/Output 1 Conditions Symbol Min Typ Max Units Free air t < 10ms IL=1A VL=100V IL ILPK RON ILEAK - - 2.5 6 0.34 1 ADC/Arms AP Ω µA IF=10mA, VL=10V tON tOFF - - 5 3 ms IL=1A IF=5mA VR=5V IF IF VF IR 0.3 0.9 - 3.3 1.2 - 10 1.4 10 mA mA V µA - - - 2 - pF Conditions Symbol Min Typ Max Units - RθJC - 1.5 - °C/W Measurement taken within 1 second of on time. Thermal Characteristics Parameter Thermal Resistance (junction to case) 2 www.clare.com R04 CPC1916 PERFORMANCE DATA* Typical LED Forward Voltage Drop (N=50, TA=25ºC, IF=10mA) 45 35 30 25 20 15 10 25 20 15 10 5 5 1.254 1.258 1.262 1.266 LED Forward Voltage (V) 0.216 0.220 0.224 0.228 On-Resistance (Ω) Typical Turn-On Time (N=50, TA=25ºC, IL=5mADC, IF=10mA) Typical Turn-Off Time (N=50, TA=25ºC, IL=5mADC, IF=10mA) 20 15 10 5 3.5 4.0 4.5 Turn-On (ms) 5.0 15 10 5 0.05 0.04 0.03 0.02 0.01 20 40 60 Temperature (ºC) 80 131 129 3.0 127 2.5 125 123 121 119 IF=20mA 0.08 0.06 IF=10mA 0.04 0.02 0.00 0 20 40 -40 -20 0 20 60 Temperature (ºC) 80 100 40 60 80 100 120 Typical Turn-On vs. Temperature (IL=100mADC) IF=10mA 2.0 IF=20mA 1.5 1.0 0.5 0 -40 LED Forward Voltage Drop (V) 0.10 -20 0.5 3.5 100 0.12 -40 IF=10mA 1.0 Typical Blocking Voltage vs. Temperature Typical Turn-Off vs. Temperature (IL=100mADC) 0.14 IF=20mA 1.5 Temperature (ºC) 115 0 2.0 0 117 -20 2.5 Turn-Off (ms) Typical Leakage vs. Temperature at Measured across Pins 3 & 4 (VL=100V) 0 -40 3.0 0.070 0.073 0.076 0.079 0.082 0.085 0.088 Blocking Voltage (VP) Leakage (μA) 20 5.5 0.06 Turn-Off (ms) Typical Load Current vs. Temperature 3.5 -20 0 20 40 60 80 -40 100 0 20 40 60 80 100 Temperature (ºC) Typical LED Forward Voltage Drop vs. Temperature Typical Turn-On vs. LED Forward Current (IL=100mADC) 1.8 1.6 1.4 IF=50mA 1.2 IF=20mA IF=10mA 1.0 0.8 -40 -20 Temperature (ºC) Turn-On (ms) 0.07 Blocking Voltage (VP) Turn-On (ms) 3.0 10 119.1 119.6 120.0 120.6 121.1 121.6 122.1 0 0 15 0.232 Load Current (ADC/Arms) 25 20 0 0.212 Device Count (N) Device Count (N) 1.250 25 5 0 0 Typical Blocking Voltage Distribution (N=50, TA=25ºC) 30 Device Count (N) 35 25 35 30 Device Count (N) Device Count (N) 40 Typical On-Resistance Distribution (N=50, TA=25ºC, IL=1.0ADC, IF=10mA) -20 0 20 40 60 80 Temperature (ºC) 100 120 6.0 5.4 4.8 4.2 3.6 3.0 2.4 1.8 1.2 0.6 0 0 5 10 15 20 25 30 35 40 50 45 LED Forward Current (mA) *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. R04 www.clare.com 3 CPC1916 PERFORMANCE DATA* 0.36 0.10 0.32 On-Resistance (Ω) 0.11 Turn-Off (ms) 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.28 0.24 0.20 0.16 0.12 0.08 0.04 0.02 0 0 5 10 15 20 25 30 35 40 LED Forward Current (mA) 45 50 -40 Typical Load Current vs. Load Voltage (TA=25ºC, IF=10mA) 2.5 2.0 1.5 1.0 0.5 0 -0.5 -1.0 -1.5 -2.0 -2.5 -0.6 -0.4 -0.2 0 0.2 Load Voltage (V) 0.4 0.6 -20 0 20 40 60 Temperature (ºC) 80 100 Typical IF for Switch Operation vs. Temperature (IL=100mADC) 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0 -40 -20 0 20 40 60 80 100 Temperature (ºC) Energy Rating Curve (Free Air, No Heat Sink) 7 Load Currrent (A) Load Current (A) Typical On-Resistance vs. Temperature (IL=1.0ADC, IF=10mA) LED Current (mA) Typical Turn-Off vs. LED Forward Current (IL=100mADC) 6 5 4 3 2 10μs 100μs 1ms 10ms 100ms Time 1s 10s 100s *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 4 www.clare.com R04 CPC1916 Manufacturing Information Soldering For proper assembly, the component must be processed in accordance with the current revision of IPC/JEDEC standard J-STD-020. Failure to follow the recommended guidelines may cause permanent damage to the device resulting in impaired performance and/or a reduced lifetime expectancy. Washing Clare does not recommend ultrasonic cleaning or the use of chlorinated solvents. Pb RoHS 2002/95/EC e3 MECHANICAL DIMENSIONS 21.082 ± 0.381 (0.830 ± 0.015) 7º TYP 4 PLCS 3.302 ± 0.051 (0.130 ± 0.002) 10.160 ± 0.127 (0.400 ± 0.005) 1.016 ± 0.127 (0.040 ± 0.005) Pin 1 0.762 ± 0.076 (0.030 ± 0.003) 2.540 ± 0.127 (0.100 ± 0.005) 1.778 (0.070) 10.160 ± 0.127 (0.400 ± 0.005) Pin 4 4.572 ± 0.127 (0.180 ± 0.005) 0.381 ± 0.013 (0.015 ± 0.0005) 1.651 ± 0.102 (0.065 ± 0.004) 5.080 ± 0.127 (0.200 ± 0.005) Recommended Hole Pattern 4 x 1.326 (0.052) DIA. 2.540 (0.100) 12.700 (0.500) 17.780 (0.700) Dimensions mm (inches) Note: Recommended hole size is based on the maximum cross-section diagonal measure of the pin plus 0.4mm (0.016). For additional information please visit our website at: www.clare.com Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of Sale, Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice. 5 Specification: DS-CPC1916-R04 ©Copyright 2008, Clare, Inc. OptoMOS® is a registered trademark of Clare, Inc. All rights reserved. Printed in USA. 9/16/08