CLARE CPC1916Y Power sip relay Datasheet

CPC1916
Power SIP Relay
Parameter
Blocking Voltage
Load Current
On-Resistance
Rating
100
2.5
0.34
Description
Units
VP
ADC/Arms
Ω
Clare and IXYS have combined to bring OptoMOS®
technology, reliability, and compact size to a new
family of high-power, solid state relays. As part of
that family, the CPC1916 is a 1-Form-A solid state
relay. The CPC1916 employs optically coupled
MOSFET technology to provide 2500Vrms of input
to output isolation. The efficient MOSFET switches
and photovoltaic die use Clare’s patented OptoMOS
architecture, while the output is controlled by a highly
efficient GaAlAs infrared LED. The combination of
low on-resistance and high load-current handling
capabilities makes the relay suitable for a variety of
high-performance switching applications.
Features
•
•
•
•
•
•
•
•
•
Power SIP Package
Handle Load Currents Up to 2.5ADC/Arms
High Reliability
No Moving Parts
Low Drive Power Requirements (TTL/CMOS
Compatible)
Arc-Free With No Snubbing Circuits
2500Vrms Input/Output Isolation
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Approvals
• UL Recognized Component: File # E69938
• Certified to: UL 508
Ordering Information
Applications
•
•
•
•
•
Industrial Controls
Motor Control
Robotics
Medical Equipment—Patient/Equipment Isolation
Instrumentation
• Multiplexers
• Data Acquisition
• Electronic Switching
• I/O Subsystems
• Meters (Watt-Hour, Water, Gas)
• IC Equipment
• Home Appliances
Part #
CPC1916Y
Description
Power SIP Package (25 per tube)
Pin Configuration
1
-
2
+
3
4
Switching Characteristics of
Normally Open (Form A) Devices
Control
ILOAD
+
90%
10%+
Pb
RoHS
2002/95/EC
DS-CPC1916-R04
tOFF
e3
tON
www.clare.com
1
CPC1916
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Blocking Voltage
Reverse Input Voltage
Input control Current
Peak (10ms)
Input Power Dissipation 1
Isolation voltage Input to Output
Operational Temperature
Storage Temperature
1
Ratings
100
5
50
1
150
2500
-40 to +85
-40 to +125
Units
VP
V
mA
A
mW
Vrms
°C
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Derate Linearly 3.33 mw / ºC
Electrical Characteristics
Parameter
Output Characteristics @ 25°C
Load Current, Continuous
Peak Load Current
On-Resistance 1
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Input Characteristics @ 25°C
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Current
Common Characteristics @ 25°C
Capacitance Input/Output
1
Conditions
Symbol
Min
Typ
Max
Units
Free air
t < 10ms
IL=1A
VL=100V
IL
ILPK
RON
ILEAK
-
-
2.5
6
0.34
1
ADC/Arms
AP
Ω
µA
IF=10mA, VL=10V
tON
tOFF
-
-
5
3
ms
IL=1A
IF=5mA
VR=5V
IF
IF
VF
IR
0.3
0.9
-
3.3
1.2
-
10
1.4
10
mA
mA
V
µA
-
-
-
2
-
pF
Conditions
Symbol
Min
Typ
Max
Units
-
RθJC
-
1.5
-
°C/W
Measurement taken within 1 second of on time.
Thermal Characteristics
Parameter
Thermal Resistance (junction to case)
2
www.clare.com
R04
CPC1916
PERFORMANCE DATA*
Typical LED Forward Voltage Drop
(N=50, TA=25ºC, IF=10mA)
45
35
30
25
20
15
10
25
20
15
10
5
5
1.254
1.258
1.262
1.266
LED Forward Voltage (V)
0.216 0.220 0.224 0.228
On-Resistance (Ω)
Typical Turn-On Time
(N=50, TA=25ºC, IL=5mADC, IF=10mA)
Typical Turn-Off Time
(N=50, TA=25ºC, IL=5mADC, IF=10mA)
20
15
10
5
3.5
4.0
4.5
Turn-On (ms)
5.0
15
10
5
0.05
0.04
0.03
0.02
0.01
20
40
60
Temperature (ºC)
80
131
129
3.0
127
2.5
125
123
121
119
IF=20mA
0.08
0.06
IF=10mA
0.04
0.02
0.00
0
20
40
-40
-20
0
20
60
Temperature (ºC)
80
100
40
60
80
100
120
Typical Turn-On vs. Temperature
(IL=100mADC)
IF=10mA
2.0
IF=20mA
1.5
1.0
0.5
0
-40
LED Forward Voltage Drop (V)
0.10
-20
0.5
3.5
100
0.12
-40
IF=10mA
1.0
Typical Blocking Voltage
vs. Temperature
Typical Turn-Off vs. Temperature
(IL=100mADC)
0.14
IF=20mA
1.5
Temperature (ºC)
115
0
2.0
0
117
-20
2.5
Turn-Off (ms)
Typical Leakage vs. Temperature at
Measured across Pins 3 & 4
(VL=100V)
0
-40
3.0
0.070 0.073 0.076 0.079 0.082 0.085 0.088
Blocking Voltage (VP)
Leakage (μA)
20
5.5
0.06
Turn-Off (ms)
Typical Load Current vs. Temperature
3.5
-20
0
20
40
60
80
-40
100
0
20
40
60
80
100
Temperature (ºC)
Typical LED Forward Voltage Drop
vs. Temperature
Typical Turn-On vs. LED Forward Current
(IL=100mADC)
1.8
1.6
1.4
IF=50mA
1.2
IF=20mA
IF=10mA
1.0
0.8
-40
-20
Temperature (ºC)
Turn-On (ms)
0.07
Blocking Voltage (VP)
Turn-On (ms)
3.0
10
119.1 119.6 120.0 120.6 121.1 121.6 122.1
0
0
15
0.232
Load Current (ADC/Arms)
25
20
0
0.212
Device Count (N)
Device Count (N)
1.250
25
5
0
0
Typical Blocking Voltage Distribution
(N=50, TA=25ºC)
30
Device Count (N)
35
25
35
30
Device Count (N)
Device Count (N)
40
Typical On-Resistance Distribution
(N=50, TA=25ºC, IL=1.0ADC, IF=10mA)
-20
0
20
40
60
80
Temperature (ºC)
100
120
6.0
5.4
4.8
4.2
3.6
3.0
2.4
1.8
1.2
0.6
0
0
5
10
15
20
25
30
35
40
50
45
LED Forward Current (mA)
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please
contact our application department.
R04
www.clare.com
3
CPC1916
PERFORMANCE DATA*
0.36
0.10
0.32
On-Resistance (Ω)
0.11
Turn-Off (ms)
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.28
0.24
0.20
0.16
0.12
0.08
0.04
0.02
0
0
5
10 15 20 25 30 35 40
LED Forward Current (mA)
45
50
-40
Typical Load Current vs. Load Voltage
(TA=25ºC, IF=10mA)
2.5
2.0
1.5
1.0
0.5
0
-0.5
-1.0
-1.5
-2.0
-2.5
-0.6
-0.4
-0.2
0
0.2
Load Voltage (V)
0.4
0.6
-20
0
20
40
60
Temperature (ºC)
80
100
Typical IF for Switch Operation
vs. Temperature
(IL=100mADC)
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
-40
-20
0
20
40
60
80
100
Temperature (ºC)
Energy Rating Curve
(Free Air, No Heat Sink)
7
Load Currrent (A)
Load Current (A)
Typical On-Resistance vs. Temperature
(IL=1.0ADC, IF=10mA)
LED Current (mA)
Typical Turn-Off vs. LED Forward Current
(IL=100mADC)
6
5
4
3
2
10μs 100μs 1ms 10ms 100ms
Time
1s
10s
100s
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please
contact our application department.
4
www.clare.com
R04
CPC1916
Manufacturing Information
Soldering
For proper assembly, the component must be
processed in accordance with the current revision
of IPC/JEDEC standard J-STD-020. Failure to
follow the recommended guidelines may cause
permanent damage to the device resulting in impaired
performance and/or a reduced lifetime expectancy.
Washing
Clare does not recommend ultrasonic cleaning or the
use of chlorinated solvents.
Pb
RoHS
2002/95/EC
e3
MECHANICAL DIMENSIONS
21.082 ± 0.381
(0.830 ± 0.015)
7º TYP
4 PLCS
3.302 ± 0.051
(0.130 ± 0.002)
10.160 ± 0.127
(0.400 ± 0.005)
1.016 ± 0.127
(0.040 ± 0.005)
Pin 1
0.762 ± 0.076
(0.030 ± 0.003)
2.540 ± 0.127
(0.100 ± 0.005)
1.778
(0.070)
10.160 ± 0.127
(0.400 ± 0.005)
Pin 4
4.572 ± 0.127
(0.180 ± 0.005)
0.381 ± 0.013
(0.015 ± 0.0005)
1.651 ± 0.102
(0.065 ± 0.004)
5.080 ± 0.127
(0.200 ± 0.005)
Recommended Hole Pattern
4 x 1.326 (0.052) DIA.
2.540 (0.100)
12.700 (0.500)
17.780 (0.700)
Dimensions
mm
(inches)
Note: Recommended hole size is based on the maximum
cross-section diagonal measure of the pin plus 0.4mm (0.016).
For additional information please visit our website at: www.clare.com
Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications
and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of
Sale, Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability,
fitness for a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other
applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental
damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice.
5
Specification: DS-CPC1916-R04
©Copyright 2008, Clare, Inc.
OptoMOS® is a registered trademark of Clare, Inc.
All rights reserved. Printed in USA.
9/16/08
Similar pages