MPD MPM-10T-0524 Compact, 10w pc mount single, dual & triple out ac/dc power supply Datasheet

MPM-10 Series
Compact, 10W PC Mount
Single, Dual & Dual ISO Out
AC/DC Power Supplies
Electrical Specifications
Key Features:
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• 10W Output Power
Parameter
• Universal 85-264 VAC Input
Input Voltage Range
• EN 60950 Approved (UL)
Conditions
Input Frequency
• Single, Dual & Dual Iso Outputs Input Current
• Meets EN 55022 B
Inrush Current
• >200 kHour MTBF
• Compact PC Mount Case
EMI
Safety Ground Leakage Current
Min.
Typ.
85
120
47
See Model Selection Guide
115 VAC
10.0
230 VAC
20.0
Meets CISPR Pub. 22/FCC Class B
115 VAC
230 VAC
Max.
264
370
63
Units
VAC
VDC
Hz
A Pk
0.1
0.3
mA
Max.
Units
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Overload Protection
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
±2.0
±0.5
See Model Selection Guide
50
115 VAC
20
230 VAC
80
±0.02
Continuous (Autorecovery)
Typ. 110% of Output Power
%
mV Pk - Pk
mSec
%/°C
General
Parameter
Isolation Voltage
EMI/RFI
EMC Compliance
Conditions
Input to Output
Input to Ground
Output to Ground
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Min.
3,000
1,500
500
Conditions
Min.
-25
Switching Frequency
Typ.
Max.
Units
VAC
EN 55022 Level B
EN 61000-4-2 Level 3 6kV/8kV
EN61000-4-3
EN 61000-4-4 Level 3 2 kV
EN 61000-4-5 Level 3 1kV/2 kV
150
kHz
Environmental
Parameter
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Max.
+70
+90
-25
+105
Free Air Convection (See Derating Curve)
RH, Non-condensing
85
Ambient
Case
Typ.
+25
Units
°C
°C
°C
%
2.16 x 1.77 x 0.81 Inches (55.0 x 45.0 x 20.5 mm)
Non-Conductive Black Plastic (UL94-V0)
4.23 Oz (120g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
200
UL 60950, EN 60950
UL, cUL; File No. E245422
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Current (A)
Voltage
115 VAC 230 VAC
MPM-10S-03
MPM-10S-05
MPM-10S-09
MPM-10S-12
MPM-10S-15
MPM-10S-24
MPM-10D-05
MPM-10D-12
MPM-10D-15
MPM-10D-24
MPM-10ID-0505
MPM-10ID-0512
MPM-10ID-0515
MPM-10ID-0524
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
Output 2 (Vout 2)
Output 1 (Vout 1)
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
0.12
Output 3 (Vout 3)
Over Volt. Voltage Current (A)
Over Volt. Voltage Current (A) Efficiency
(%, Typ)
Load Protection (VDC) Rated Load Protection (VDC) Rated Load
(VDC)
(VDC)
Reg.
Reg.
Reg.
±1.0%
6.5
70
±1.0%
6.5
76
±1.0%
12.0
78
±1.0%
20.0
80
±1.0%
20.0
81
±1.0%
30.0
82
±2.0%
6.5
-5.0 -1.00 ±2.0%
6.5
76
±2.0%
20.0
-12.0 -0.45 ±2.0%
20.0
80
±2.0%
20.0
-15.0 -0.35 ±2.0%
20.0
81
±2.0%
30.0
-24.0 -0.20 ±2.0%
30.0
84
±3.0%
6.5
5.0
0.20 ±5.0%
6.5
75
±3.0%
6.5
12.0
0.20 ±5.0%
20.0
79
±3.0%
6.5
15.0
0.20 ±5.0%
20.0
79
±3.0%
6.5
24.0
0.20 ±5.0%
30.0
81
Current (A)
(VDC)
Rated
3.3
5.0
9.0
12.0
15.0
24.0
+5.0
+12.0
+15.0
+24.0
5.0
5.0
5.0
5.0
2.00
2.00
1.10
0.90
0.70
0.45
+1.00
+0.45
+0.35
+0.20
1.80
1.50
1.40
1.00
Notes:
1. Load regulation is measured for an output change of 10% to 90% at
nominal input line. For multiple output models, the loads are balanced.
2. The MPM-10 series is specified for operation over the wide operating temperature range of -25°C to +55°C without derating. For
operation over +55°C, derate the power linearly by 3.75%/°C from
+55°C to +70°C.
3. Model numbers MPM-10ID-05xx are dual isolated units (Dual
ISO). The outputs on these models are isolated from each other.
4. It is recommended that a fuse be used on the input of a power supply
for protection. For the MPM-10 series, a 2A/250 VAC slow blow
should be used.
Typical Connection
Mechanical Dimensions
Typical Component Values
Vout
C1, C3
C2, C4
Fuse
TVS
3.3
330 ~ 1,000 µF/16V
P6KE6.8A
5.0
330 ~ 1,000 µF/16V
P6KE6.8A
2A/
0.1 µF/50V
250 VAC
12.0
220 µF/25V
P6KE16A
Ceramic
Slow Blow
15.0
220 µF/25V
P6KE20A
24.0
120 µF/35V
P6KE33A
Notes:
1. C1 and C3 are high frequency, low resistance electrolytic capacitors. Refer to the suppliers
specifications for capacitance/current ratings.
2. Voltage derating on all capacitors should be 80% or higher.
3. C2 and C4 eliminate high frequency noise.
4. The TVS is recommended to protect load circuitry in the event of a module failure.
Pin Connections
Pin
1
2
3
4
5
6
7
8
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
Single
Dual
Dual ISO
AC-Ground AC-Ground AC-Ground
AC-Neutral AC-Neutral AC-Neutral
AC-Line
AC-Line
AC-Line
-Vo 1
-Vo 2
-Vo 1
No Pin
No Pin
+Vo 1
No Pin
Common
No Pin
No Pin
No Pin
-Vo 2
+Vo 1
+Vo 1
+Vo 2
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages