OPTEK DMF-50081ZNB-FW Dmf-50081znb-fw Datasheet

First Edition
Apr 10, 2000
LCD Module Specification
Approved by
Production Div.
Checked by
Quality Assurance Div.
Checked by
Design Engineering Div.
Prepared by
Production Div.
Final Revision
*******
Type No.
Table of Contents
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
General Specifications .............................................................................2
Electrical Specifications...........................................................................3
Optical Specifications ..............................................................................8
I/O Terminal ...........................................................................................10
Test..........................................................................................................12
Appearance Standards............................................................................13
Code System of Production Lot ..........................................................16
Type Number..........................................................................................16
Applying Precautions .............................................................................16
Precautions Relating Product Handling................................................17
Warranty..................................................................................................18
Revision History
Rev.
Date
DMF-50081ZNB-FW
Page
(AQ) No.2000-0130
Comment
OPTREX
OPTREX CORPORATION
Page 1/18
1.Gener al Spec ifi cations
Operating Temp.
min. 0
Storage Temp.
min. -20
max. 60
Dot Pixels
320 (W)
240 (H) dots
Dot Size
0.27 (W)
0.27 (H) mm
Dot Pitch
0.30 (W)
0.30 (H) mm
Viewing Area
103.0 (W)
Outline Dimensions
139.0 (W)
120.0* (H)
* Without CFL Cable
Weight
250g max.
LCD Type
NTD-10613
( STN / Blue-mode / Transmissive )
Viewing Angle
6:00
Data Transfer
4-bit parallel data transfer
Backlight
Cold Cathode Fluorescent Lamp (CFL)
Drawings
Dimensional Outline
DMF-50081ZNB-FW
(AQ) No.2000-0130
max. 50
79.0 (H) mm
OPTREX
13.2 max. (D) mm
1
UE-33270C
OPTREX CORPORATION
Page 2/18
2.Electr ical S pecif ications
2.1.Absolute Maximum Ratings
VSS=0V
Parameter
Supply Voltage
Symbol
Conditions
Min.
Max.
Units
VCC-VSS
-0.3
7.0
V
VCC-VEE
0
35.0
V
VI
-0.3
VCC+0.3
V
(Logic)
Supply Voltage
(LCD Drive)
Input Voltage
2.2.DC Characteristics
Ta=25 , VSS=0V
Parameter
Supply Voltage
Symbol
Conditions
Min.
VCC-VSS
Typ.
4.5
Max.
Units
5.5
V
(Logic)
VCC-VEE
V
Supply Voltage
(LCD Drive)
High Level
VCC-VADJ
Shown in 3.1
V
VIH
VCC=5.0V
10%
0.8 VCC
VCC
V
VIL
VCC=5.0V
10%
0
0.2 VCC
V
ICC
VCC-VSS=5.0V
4.6
15.0
mA
IEE
VCC-VADJ=23.3V
4.2
10.0
mA
Input Voltage
Low Level
Input Voltage
Supply Current
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 3/18
2.3.AC Characteristics
VCC=5.0V
Parameter
Symbol
Min.
10%
Max.
Units
6.0
MHz
CP Frequency
fCP
Clock Pulse Width
tWC
tWL
50
ns
63
ns
tSETUP
tHOLD
tCL
tLC
tr, tf
tFDS
tFDH
30
ns
30
ns
80
ns
0
ns
Load Pulse Width
Data Setup Time
Data Hold Time
Clock Pulse Setup Time
Clock Pulse Hold Time
Rise/Fall Time
FLM Setup Time
Note 1
100
ns
FLM Hold Time
100
t
t
Note 1:The rise and fall times ( r, f ) must satisfy the following relationships ( and
tr, tf
tr, tf
1
ns
ns
).
tWC
2fCP
50 ns
LP
tWL
tr
tCL
tf
tLC
tWC
CP
tWC
tr
tf
tSETUP
D0
tHOLD
D3
tFDS
tFDH
FLM
This module contain these capacitors. Please be careful about timing characteristics.
FLM
1000pF
LP
470pF
M
1000pF
VSS
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 4/18
2.4.Timing Chart
T=0.0595ms typ.
LP
CP
D0
SEG
SEG
D3
313
316
317
320
SEG
SEG
1
5
4
#1 DATA
8
SEG
SEG
313
316
317
320
SEG
SEG
1
5
4
8
FLM
LP
(Reduction)
240 T
FLM
(Reduction)
M
2.5.Comparison of Display and Data
SEG1
#1
D3
SEG320
D2
D1
D0
D1
D0
TOP VIEW
D0
D3
#240
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 5/18
2.6.Power Supply ON/OFF Sequence
2.6.1.ON Sequence
LEVEL
SIGNAL
VCC
VCC
VSS
0 t
VCC
SIGNAL
VSS
0 t
VCC
VADJ
VEE
VSS
VADJ
VEE
0 t
VCC
DISPOFF
VSS
2.6.2.OFF Sequence
LEVEL
SIGNAL
VCC
VCC
VSS
0 t
VCC
VSS
0
t
SIGNAL
VCC
VADJ
VSS
VEE
VADJ
VEE
VCC
0 t
DISPOFF
VSS
Please maintain the above sequence when turning on and off the power supply of the module.
If DISPOFF is supplied to the module while alternate signal for LCD driving (M) is unstable,
DC component will be supplied to the LCD panel. This may cause damage the LCD module.
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 6/18
2.7.Lighting Specifications
Ta=25
Parameter
Symbol
Lamp Voltage
VL
Lamp Current
IL
Starting Voltage
VS
Surface Luminance
L
Conditions
Min.
Typ.
Max.
246
4.0
5.0
6.0
370
IL=5.0mA
60
Units
Notes
Vrms
1
mArms
2
Vrms
3
cd/
4
Average Life
TAL
IL=5.0mA
10000
15000
hrs
5
Note 1 : The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after lighting for
3 minutes .
Note 2 : The current ( r.m.s. ) to flow through the lamp with the electric discharge. It is measured after
lighting for 3 minutes.
Note 3 : The voltage at starting the electric discharge when the voltage is increased gradually from 0V.
Note 4 : Surface Luminance is specified by the initial data of luminance measured at the center of display
surface after 20 minutes power on. ( All ON pattern )
Note 5 : CFL life is defined as the time for which the initial luminance is attenuated by 50% of the
luminance value. Average Life representes the time elapsed at the point of time when the residual
ratio becomes below 50% when plural lamps are lighted in comparison with the definition of life
mentioned above.
I
N
C
VS
VL
V
F
L
IL
CFL Testing Circuit
Recommended Inverter : S-12561 ( Produced by ELEVAM ) CXA-L10L ( Produced by TDK)
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 7/18
3.Optical S peci fic ati ons
3.1.LCD Driving Voltage
Parameter
Symbol
Recommended
Conditions
Min.
Typ.
Ta= 0
LCD Driving Voltage
VCC-VADJ
Ta=25
21.7
23.3
Max.
Units
27.1
V
24.9
V
Note 1
Ta=50
19.9
V
Note 1 :
Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of
minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and
response time are not guaranteed over the entire range.
3.2.Optical Characteristics
Ta=25 , 1/240 Duty, 1/15 Bias, VD=23.3V (Note 4),
Parameter
Contrast Ratio
Symbol
Note 1
CR
Conditions
=0 ,
Min.
=
Time
=
Max.
Units
4
Viewing Angle
Response
Typ.
=0 ,
Shown in 3.3
Rise
Note 2
TON
100
200
ms
Decay Note 3
TOFF
360
540
ms
Note 1 : Contrast ratio is definded as follows.
CR = LON / LOFF
LON : Luminance of the ON segments
LOFF : Luminance of the OFF segments
Note 2 : The time that the luminance level reaches 90% of the saturation level from 0% when ON
signal is applied.
Note 3 : The time that the luminance level reaches 10% of the saturation level from 100% when OFF
signal is applied.
Note 4 : Definition of Driving Voltage VD
VD=VCC-VADJ-VBE
Assuming that the typical driving waveforms shown below are applied to the LCD Panel at
1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage VD is definded
as the voltage VO-P when the contrast ratio (CR=LON / LOFF) is at its maximum.
VO-P
( B-2 ) VO-P / B
1 / ( fF
1 / fF
A)
ON SIGNAL
DMF-50081ZNB-FW
(AQ) No.2000-0130
OFF SIGNAL
OPTREX
OPTREX CORPORATION
Page 8/18
3.3.Definition of Viewing Angle and Optimum Viewing Area
Point
shows the point where contrast ratio is measured. : = 0 ,
Driving condition : 1/240 Duty, 1/15 Bias, VD=23.3V, fF=70Hz
=
90
45
135
90
10 20 30 40 50
180
(
=0
180
225
0
315
270
270
Area
shows typ. CR
2
3.4.System Block Diagram
Temperature Chamber
Rotation Table (
Photometer
#1980A WB
, )
LCD
Optical Fiber
Computer
Control Unit &
Waveform Generator
Halogen bulb
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 9/18
4.I/O Terminal
4.1.Pin Assignment
CN1
No.
Symbol
Level
Function
1
FLM
H/L
First Line Marker
2
LP
H/L
Data Latch Signal
3
CP
H/L
Clock Signal for Shifting Data
4
M
H/L
Alternate Signal for LCD Drive
5
VADJ
Voltage Level for LCD Contrast Adjustment
6
VCC
Power Supply for Logic
7
VSS
Power Supply (0V, GND)
8
VEE
Power Supply for LCD Drive
9
D0
H/L
Display Data
10
D1
H/L
Display Data
11
D2
H/L
Display Data
12
D3
H/L
Display Data
13
DISPOFF
H/L
Display Control Signal H : Display on L : Display off
14
NC
Non-connection
CN2
No.
Symbol
Level
Function
1
FL
Power Supply for CFL (HOT)
2
NC
Non-connection
3
NC
Non-connection
4
FL GND
Power Supply for CFL (GND)
4.2.Example of Power Supply
It is recommended to apply a potentiometer for the contrast adjust due to the tolerance
of the driving voltage and its temperature dependence.
VCC
VCC (+Voltage)
R1
VADJ
VR
MODULE
R2
VEE
VEE (-Voltage)
VSS
VSS (0V)
R1+R2+VR=10 20K
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 10/18
4.3.Block Diagram
Row Driver
3
LC79431D
or equivalent
FLM
240
LCDP
320
240 dots
320
LP
Column Driver
LC79401D
4
or equivalent
2
M
DISPOFF
CP
4
D0 D3
M Circuit
VCC
VSS
Bias Circuit
To LSI
VADJ
VEE
FL
CFL Backlight
FL GND
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 11/18
5.Tes t
No change on display and in operation under the following test condition.
No.
Parameter
Conditions
1
High Temperature Operating
50
2
2
Low Temperature Operating
0
3
High Temperature Storage
60
4
Low Temperature Storage
-20
5
Damp Proof Test
40
6
Vibration Test
Total fixed amplitude : 1.5mm
2
, 96hrs (operation state)
, 96hrs (operation state)
2
2
2
Notes
, 96hrs
4
, 96hrs
, 90
3
3, 4
95%RH, 96hrs
Vibration Frequency : 10
3, 4
5
55Hz
One cycle 60 seconds to 3 directions of X, Y, Z for
each 15 minutes
7
Shock Test
To be measured after dropping from 60cm high on
the concrete surface in packing state.
F
E
G
B
D
C
A
60cm
Dropping method corner dropping
A corner : once
Edge dropping
B,C,D edge : once
Face dropping
E,F,G face : once
Concrete Surface
Note 1 : Unless otherwise specified, tests will be conducted under the following condition.
Temperature : 20 5
Humidity
: 65 5%
Note 2 : Unless otherwise specified, tests will be not conducted under functioning state.
Note 3 : No dew condensation to be observed.
Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity
after removed from the test chamber.
Note 5 : Vibration test will be conducted to the product itself without putting it in a container.
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 12/18
6.Appearance Standards
6.1.Inspection conditions
The LCD shall be inspected under 40W white fluorescent light.
The distance between the eyes and the sample shall be more than 30cm.
All directions for inspecting the sample should be within 45 against perpendicular line.
45
6.2.Definition of applicable Zones
A Zone
Bezel Flame
B Zone
C Zone
A Zone : Active display area
B Zone : Area from outside of "A Zone" to validity viewing area
C Zone : Rest parts
A Zone + B Zone = Validity viewing area
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 13/18
6.3.Standards
No.
1
Parameter
Black and
Criteria
(1) Round Shape
White Spots,
Foreign Substances
Zone
Acceptable Number
Dimension (mm)
A
B
C
D
0.1
*
*
*
0.1
D
0.2
3
5
*
0.2
D
0.25
2
3
*
0.25
D
0.3
0
1
*
0.3
D
0
0
*
D = ( Long + Short ) / 2
* : Disregard
(2) Line Shape
Zone
X (mm)
Acceptable Number
Y (mm)
A
B
C
0.03 W
*
*
*
2.0
L
0.05
W
3
3
*
1.0
L
0.1
W
3
3
*
0.1
W
X : Length Y : Width
In the same way (1)
* : Disregard
Total defects shall not exceed 5.
2
Air Bubbles
(between glass
& polarizer)
Zone
Dimension (mm)
Acceptable Number
A
B
C
D
0.3
*
*
*
0.3
D
0.4
3
*
*
0.4
D
0.6
2
3
*
0.6
D
0
0
*
* : Disregard
Total defects shall not exceed 3.
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 14/18
No.
3
Parameter
The Shape of Dot
Criteria
(1) Dot Shape (with Dent)
0.15
As per the sketch of left hand.
(2) Dot Shape (with Projection)
Should not be connected to next dot.
(3) Pin Hole
X
(X+Y) / 2
Y
0.2mm
(Less than 0.1mm is no counted.)
(4) Deformation
(X+Y) / 2
Y
0.2mm
X
Total acceptable number : 1/dot, 5/cell
(Defect number of (4) : 1pc.)
4
Polarizer Scratches
Not to be conspicuous defects.
5
Polarizer Dirts
If the stains are removed easily from LCDP surface, the module is not
defective.
6
7
Complex Foreign
Black spots, line shaped foreign substances or air bubbles between
Substance Defects
glass & polarizer should be 5pcs maximum in total.
Distance between
D 0.2 : 20mm or more
Different Foreign
0.2
D : 40mm or more
Substance Defects
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 15/18
7.Code System of P roducti on Lot
The production lot of module is specified as follows.
Factory Number (Numeral)
Factory Code (Alphabet)
Production Week (1 5)
Production Month (1 9, X, Y, Z)
Production Year (Lower 2 digits)
8.Type Number
The type number of module is specified on the back of module as follows.
Stamp
Etching or Printing
9.Applying Pr ecautions
Please contact us when questions and/or new problems not specified in this specifications arise.
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 16/18
10.P recautions Relating Pr oduct Handling
The Following precautions will guide you in handling our product correctly.
1) Liquid crystal display devices
The liquid crystal display device panel used in the liquid crystal display module is made of plate
glass. Avoid any strong mechanical shock. Should the glass break handle it with care.
The polarizer adhering to the surface of the LCD is made of a soft material.
Guard against scratching it.
2) Care of the liquid crystal display module against static electricity discharge.
When working with the module, be sure to ground your body and any electrical equipment you may
be using. We strongly recommend the use of anti static mats ( made of rubber ), to protect work
tables against the hazards of electrical shock.
Avoid the use of work clothing made of synthetic fibers. We recommend cotton clothing or other
conductivity-treated fibers.
Slowly and carefully remove the protective film from the LCD module, since this operation can
generate static electricity.
3) When the LCD module alone must be stored for long periods of time:
Protect the modules from high temperature and humidity.
Keep the modules out of direct sunlight or direct exposure to ultraviolet rays.
Protect the modules from excessive external forces.
4) Use the module with a power supply that is equipped with an overcurrent protector circuit,
since the module is not provided with this protective feature.
5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should hands
or clothing come in contact with LCD fluid, wash immediately with soap.
6) Conduc1tivity is not guaranteed for models that use metal holders where solder connections
between the metal holder and the PCB are not used. Please contact us to discuss appropriate
ways to assure conductivity.
7) For models which use CFL:
High voltage of 1000V or greater is applied to the CFL cable connector area.
Care should be taken not to touch connection areas to avoid burns.
Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn.
The use of CFLs for extended periods of time at low temperatures will significantly shorten their
service life.
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 17/18
8) For models which use touch panels:
Do not stack up modules since they can be damaged by components on neighboring modules.
Do not place heavy objects on top of the product. This could cause glass breakage.
9) For models which use COG,TAB,or COF:
The mechanical strength of the product is low since the IC chip faces out unprotected from the rear.
Be sure to protect the rear of the IC chip from external forces.
Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical
damage, avoid installation configurations in which the rear of the IC chip runs the risk of making
any electrical contact.
10) Models which use flexible cable, heat seal, or TAB:
In order to maintain reliability, do not touch or hold by the connector area.
Avoid any bending, pulling, or other excessive force, which can result in broken connections.
11.W ar ranty
This product has been manufactured to your company’s specifications as a part for use in your company’s
general electronic products. It is guaranteed to perform according to delivery specifications. For any other
use apart from general electronic equipment, we cannot take responsibility if the product is used in medical
devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other
applications in which there is a direct risk to human life and where extremely high levels of reliability are
required. If the product is to be used in any of the above applications, we will need to enter into a separate
product liability agreement.
We cannot accept responsibility for any defect, which may arise from additional manufacturing of
the product (including disassembly and reassembly), after product delivery.
We cannot accept responsibility for any defect, which may arise after the application of strong
external force to the product.
We cannot accept responsibility for any defect, which may arise due to the application of static
electricity after the product has passed your company’s acceptance inspection procedures.
When the product is in CFL models, CFL service life and brightness will vary according to the
performance of the inverter used, leaks, etc. We cannot accept responsibility for product
performance, reliability, or defect, which may arise.
We cannot accept responsibility for intellectual property of a third party, which may arise through the
application of our product to your assembly with exception to those issues relating directly to the
structure or method of manufacturing of our product.
Optrex will not be held responsible for any quality guarantee issue for defect products judged as
Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex
America, Optrex Europe, Display LC delivery which ever comes later.
DMF-50081ZNB-FW
(AQ) No.2000-0130
OPTREX
OPTREX CORPORATION
Page 18/18
Similar pages