Features
Description
• This Circuit is Processed in Accordance to MIL-STD883 and is Fully Conformant Under the Provisions of
Paragraph 1.2.1.
The Intersil 80C286/883 is a static CMOS version of the
NMOS 80286 microprocessor. The 80C286/883 is an
advanced, high-performance microprocessor with specially
optimized capabilities for multiple user and multi-tasking systems. The 80C286/883 has built-in memory protection that
supports operating system and task isolation as well as program and data privacy within tasks. The 80C286/883
includes memory management capabilities that map 230
(one gigabyte) of virtual address space per task into 224
bytes (16 megabytes) of physical memory.
• Compatible with NMOS 80286/883
• Static CMOS Design for Low Power Operation
- ICCSB = 5mA Maximum
- ICCOP = 185mA Maximum (80C286-10/883)
- ICCOP = 220mA Maximum (80C286-12/883)
• Large Address Space
- 16 Megabytes Physical
- 1 Gigabyte Virtual per Task
• Integrated Memory Management, Four-Level Memory
Protection and Support for Virtual Memory and
Operating Systems
• Two 80C86 Upward Compatible Operating Modes
- 80C286/883 Real Address Mode
- Protected Virtual Address Mode
• Compatible with 80287 Numeric Data Co-Processor
The 80C286/883 is upwardly compatible with 80C86 and
80C88 software (the 80C286/883 instruction set is a superset of the 80C86/80C88 instruction set). Using the 80C286/
883 real address mode, the 80C286/883 is object code compatible with existing 80C86 and 80C88 software. In protected virtual address mode, the 80C286/883 is source code
compatible with 80C86 and 80C88 software but may require
upgrading to use virtual address as supported by the
80C286/883’s integrated memory management and protection mechanism. Both modes operate at full 80C286/883
performance and execute a superset of the 80C86 and
80C88 instructions.
The 80C286/883 provides special operations to support the
efficient implementation and execution of operating systems.
For example, one instruction can end execution of one task,
save its state, switch to a new task, load its state, and start
execution of the new task. The segment-not-present exception and restartable instructions.
Ordering Information
PACKAGE
68 Pin PGA
TEMP. RANGE
10MHz
0oC to +70oC
-
o
o
-40 C to +85 C
IG80C286-10
12.5MHz
CG80C286-12
16MHz
CG80C286-16
IG80C286-12
20MHz
CG80C286-20
25MHz
PKG. NO.
-
G68.B
-
-
-
G68.B
-55oC to +125oC MG80C286-10/883 MG80C286-12/883
-
-
-
G68.B
5962-9067801MXC 5962-9067802MXC
-
-
-
G68.B
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 321-724-7143 | Intersil (and design) is a trademark of Intersil Americas Inc.
Copyright © Intersil Americas Inc. 2002. All Rights Reserved
128
FN2948.1
80C286/883
Pinout
68 LEAD PGA, COMPONENT PAD VIEW
D15
ERROR
D14
D7
D13
D6
D12
D5
D11
D4
D10
D3
D9
D2
D8
D1
A0
D0
VSS
As viewed from underside of the component when mounted on the board.
35
37
39
41
43
45
47
49
51
38
40
42
44
46
48
50
53
52
ERROR
NC
55
54
NC
BUSY
NC
D0
34
36
32
33
NC
A5
A4
26
27
61
60
PEREQ
VSS
A7
A6
24
25
63
62
READY
VCC
A8
22
23
65
64
HLDA
HOLD
A10
20
21
67
66
M/IO
COD/INTA
A13
A12
18
19
16
14
12
10
8
6
4
2
68
NC
LOCK
17
15
13
11
9
7
5
3
1
PIN 1 INDICATOR
BHE
S0
A23
VSS
NC
A9
A11
S1
NMI
NC
58
PEACK
59
A22
29
A21
28
A19
RESET
A17
A3
A20
56
A18
57
A15
31
A16
30
INTR
A12
A1
CLK
A14
A2
VCC
P.C. BOARD VIEW
D10
D9
D8
D3
D2
D1
D0
45
43
41
39
37
35
52
53
50
48
46
44
42
40
38
36
34
D0
A0
NC
54
55
33
32
A1
A2
INTR
56
57
31
30
CLK
VCC
58
59
29
28
RESET
A3
A5
NC
VSS
D11
D4
47
BUSY
D12
D5
49
ERROR
D13
D6
51
NC
D14
D7
D15
ERROR
As viewed from the component side of the P.C. board.
65
23
22
A8
A9
COD/INTA
M/IO
66
67
21
20
A10
A11
68
2
4
6
8
10
12
14
16
19
18
A12
A13
1
3
5
7
9
11
13
15
17
PIN 1 INDICATOR
NC
BHE
LOCK
A12
64
A14
HLDA
A15
HOLD
A16
A7
A17
A6
A18
24
A19
25
A20
63
A21
62
VSS
READY
A22
VCC
A23
26
PEACK
27
S0
61
S1
60
A4
NC
NMI
PEREQ
NC
NC
VSS
129
80C286/883
Absolute Maximum Ratings
Thermal Information
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +8.0V
Input, Output or I/O Voltage Applied. . . . . . GND -1.0V to VCC +1.0V
Storage Temperature Range . . . . . . . . . . . . . . . . . -65oC to +150oC
Junction Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +175oC
Lead Temperature (Soldering 10s). . . . . . . . . . . . . . . . . . . . +300oC
ESD Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class 1
θJC
Thermal Resistance (Typical)
θJA
PGA Package . . . . . . . . . . . . . . . . . . . . .
35oC/W
6oC/W
Gate Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22,500 Gates
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTE:
1. θJA is measured with the component mounted on an evaluation PC board in free air.
Operating Conditions
Operating Voltage Range . . . . . . . . . . . . . . . . . . . . . +4.5V to +5.5V
Operating Temperature Range. . . . . . . . . . . . . . . . -55oC to +125oC
System Clock (CLK) RISE Time (From 1.0V to 3.6V . . . . 8ns (Max)
System Clock (CLK) FALL Time (from 3.6V to 1.0V) . . . . 8ns (Max)
Input RISE and FALL Time (From 0.8V to 2.0V
80C286-10/883 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10ns (Max)
80C286-12/883 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8ns (Max)
TABLE 1. 80C286/883 D.C. ELECTRICAL PERFORMANCE SPECIFICATIONS
Device Guaranteed and 100% Tested
PARAMETER
Input LOW Voltage
Input HIGH Voltage
CLK Input LOW Voltage
CLK Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
SYMBOL
VIL
VIH
V ILC
VIHC
VOL
VOH
CONDITIONS
VCC = 4.5V
VCC = 5.5V
VCC = 4.5V
VCC = 5.5V
IOL = 2.0mA, VCC = 4.5V
IOH = -2.0mA, VCC = 4.5V
LIMITS
GROUP A
SUBGROUPS
TEMPERATURE
MIN
MAX
UNITS
1, 2, 3
-55oC ≤ TA ≤ +125oC
-0.5
0.8
V
1, 2, 3
-55oC
≤ TA ≤
+125oC
2.0
VCC +0.5
V
1, 2, 3
-55oC
≤ TA ≤
+125oC
-0.5
1.0
V
1, 2, 3
-55 C ≤ TA ≤ +125 C
3.6
VCC +0.5
V
1, 2, 3
-55oC
-
0.4
V
1, 2, 3
-55 C ≤ TA ≤ +125 C
o
o
≤ TA ≤
o
+125oC
o
IOH = -100µA, VCC = 4.5V
Input Leakage Current
II
3.0
-
V
VCC -0.4
-
V
VIN = GND or VCC ,
VCC = 5.5V,
Pins 29, 31, 57, 59, 61,
63-64
1, 2, 3
-55 C ≤ TA ≤ +125 C
-10
10
µA
o
o
Input Sustaining Current
LOW
IBHL
VCC = 4.5V and 5.5V,
VIN = 1.0V, Note 1
1, 2, 3
-55oC ≤ TA ≤ +125oC
38
200
µA
Input Sustaining Current
HIGH
IBHH
VCC = 4.5V and 5.5V,
VIN = 3.0V, Note 2
1, 2, 3
-55oC ≤ TA ≤ +125oC
-50
-400
µA
Input Sustaining Current
on BUSY and ERROR
Pins
ISH
VCC = 4.5V and 5.5V
VIN = GND, Note 5
1, 2, 3
-55oC ≤ TA ≤ +125oC
-30
-500
µA
Output Leakage Current
IO
VO = GND or VCC
VCC = 5.5V,
Pins 1, 7-8, 10-28, 32-34
1, 2, 3
-55oC ≤ TA ≤ +125oC
-10
10
µA
1, 2, 3
-55oC ≤ TA ≤ +125oC
-
185
mA
-
220
mA
1, 2, 3
-55oC ≤ TA ≤ +125oC
-
5
mA
Active Power Supply
Current
ICCOP
80C286-10/883, Note 4
Standby Power
Supply Current
ICCSB
VCC = 5.5V, Note 3
80C286-12/883, Note 4
NOTES:
2. IBHL should be measured after lowering VIN to GND and then raising to 1.0V on the following pins: 36-51, 66, 67.
3. IBHH should be measured after raising V IN to VCC and then lowering to 3.0V on the following pins: 4-6, 36-51, 66-68.
4. ICCSB should be tested with the clock stopped in phase two of the processor clock cycle. VIN = VCC or GND, VCC = 5.5V, outputs unloaded.
5. ICCOP measured at 10MHz for the 80C286-10/883 and 12.5MHz for the 80C286-12/883. VIN = 2.4V or 0.4V, VCC = 5.5V, outputs unloaded.
6. ISH should be measured after raising VIN to VCC and then lowering to 0V on pins 53 and 54.
130
80C286/883
TABLE 2. 80C286/883 AC ELECTRICAL PERFORMANCE SPECIFICATIONS
AC Timings are Referenced to 0.8V and 2.0V Points of the Signals as Illustrated in Datasheet Waveforms, Unless Otherwise Noted. Device
Guaranteed and 100% Tested.
80C286/883
10MHz
12.5MHz
SYMBOL
CONDITIONS
GROUP A
SUBGROUPS
System Clock
(CLK) Period
1
VCC = 4.5V and 5.5V
9, 10, 11
-55oC ≤ TA ≤ +125oC
50
-
40
-
ns
System Clock
(CLK) Low Time
2
VCC = 4.5V and 5.5V
at 1.0V
9, 10, 11
-55oC ≤TA ≤ +125oC
12
-
11
-
ns
System Clock (CLK)
High Time
3
VCC = 4.5V and 5.5V
at 3.6V
9, 10, 11
-55oC ≤ TA ≤ +125oC
16
-
13
-
ns
Asynchronous Inputs
SETUP Time
(Note 1)
4
VCC = 4.5V
and 5.5V
9, 10, 11
-55oC ≤ TA ≤ +125oC
20
-
15
-
ns
Asynchronous Inputs
HOLD Time
(Note 1)
5
VCC = 4.5V
and 5.5V
9, 10, 11
-55oC ≤ TA ≤ +125oC
20
-
15
-
ns
RESET SETUP Time
6
VCC = 4.5V
and 5.5V
9, 10, 11
-55oC ≤ TA ≤ +125oC
19
-
10
-
ns
RESET HOLD Time
7
VCC = 4.5V
and 5.5V
9, 10, 11
-55oC ≤ TA ≤ +125oC
0
-
0
-
ns
Read Data
SETUP Time
8
VCC = 4.5V
and 5.5V
9, 10, 11
-55oC ≤ TA ≤ +125oC
8
-
5
-
ns
Read Data
HOLD Time
9
VCC = 4.5V
and 5.5V
9, 10, 11
-55oC ≤ TA ≤ +125oC
4
-
4
-
ns
READY SETUP Time
10
VCC = 4.5V
and 5.5V
9, 10, 11
-55oC ≤ TA ≤ +125oC
26
-
20
-
ns
READY HOLD Time
11
VCC = 4.5V
and 5.5V
9, 10, 11
-55oC ≤TA ≤ +125oC
25
-
20
-
ns
Status/PEACK Active
Delay, (Note 4)
12A
VCC = 4.5V and
5.5V, CL = 100pF
IL = |2mA|
9, 10, 11
-55oC ≤ TA ≤ +125oC
1
22
1
21
ns
Status/PEACK
Inactive Delay
(Note 3)
12B
VCC = 4.5V and
5.5V, CL = 100pF
IL = |2mA|
9, 10, 11
-55oC ≤ TA ≤ +125oC
1
30
1
24
ns
Address Valid
Delay (Note 2)
13
VCC = 4.5V and
5.5V, CL = 100pF
IL = |2mA|
9, 10, 11
-55oC ≤ TA ≤ +125oC
1
35
1
32
ns
Write Data
Valid Delay, (Note 2)
14
VCC = 4.5V and
5.5V, CL = 100pF
IL = |2mA|
9, 10, 11
-55oC ≤ TA ≤ +125oC
0
40
0
31
ns
PARAMETER
131
TEMPERATURE
MIN
MAX
MIN
MAX
UNITS
80C286/883
TABLE 2. 80C286/883 AC ELECTRICAL PERFORMANCE SPECIFICATIONS (Continued)
AC Timings are Referenced to 0.8V and 2.0V Points of the Signals as Illustrated in Datasheet Waveforms, Unless Otherwise Noted. Device
Guaranteed and 100% Tested.
80C286/883
10MHz
PARAMETER
SYMBOL
HLDA Valid Delay
(Note 5)
15
CONDITIONS
VCC = 4.5V and
5.5V, CL = 100pF
IL = |2mA|
12.5MHz
GROUP A
SUBGROUPS
TEMPERATURE
MIN
MAX
MIN
MAX
UNITS
9, 10, 11
-55oC ≤ TA ≤ +125oC
0
47
0
25
ns
NOTES:
1. Asynchronous inputs are INTR, NMI, HOLD, PEREQ, ERROR, and BUSY. This specification is given only for testing purposes, to assure
recognition at a specific CLK edge.
2. Delay from 1.0V on the CLK to 0.8V or 2.0V.
3. Delay from 1.0V on the CLK to 0.8V for Min (HOLD time) and to 2.0V for Max (inactive delay).
4. Delay from 1.0V on the CLK to 2.0V for Min (HOLD time) and to 0.8V for Max (active delay).
5. Delay from 1.0V on the CLK to 2.0V.
TABLE 3. 80C286/883 ELECTRICAL PERFORMANCE SPECIFICATIONS
80C286/883
10MHz
PARAMETER
SYMBOL
CLK Input Capacitance
CCLK
Other Input Capacitance
CIN
I/O Capacitance
CI/O
Address/Status/Data
Float Delay
15
Address Valid to Status
SETUP Time
19
CONDITIONS
FREQ = 1MHz
FREQ = 1MH
FREQ = 1MH
NOTES
TEMPERATURE
5
TA =
o
MIN
MAX
MIN
MAX
UNITS
-
10
-
10
pF
5
TA = +25 C
-
10
-
10
pF
5
+25oC
TA =
-
10
-
10
pF
+125oC
0
47
0
32
ns
-55oC ≤ TA ≤ +125oC
27
-
20
-
ns
-55oC
1, 3, 4, 5
IL = | 2.0mA|
+25oC
12.5MHz
1, 2, 5
≤ TA ≤
NOTES:
1. Output Load: C L = 100pF.
2. Delay measured from address either reaching 0.8V or 2.0V (valid) to status going active reaching 0.8V or status going inactive reaching
2.0V.
3. Delay from 1.0V on the CLK to Float (no current drive) condition.
4. I L = -6mA (VOH to Float), IL = 8mA (VOL to Float).
5. The parameters listed in Table 3 are controlled via design or process parameters and are not directly tested. These parameters are characterized upon initial design and after major process and/or design changes.
TABLE 4. APPLICABLE SUBGROUPS
CONFORMANCE GROUPS
METHOD
SUBGROUPS
Initial Test
100%/5004
-
Interim Test
100%/5004
1, 7, 9
PDA
100%
1
Final Test
100%
2, 3, 8A, 8B, 10, 11
-
1, 2, 3, 7, 8A, 8B, 9, 10, 11
Samples/5005
1, 7, 9
Group A
Group C & D
132
80C286/883
AC Electrical Specifications
82C284 and 82C288 Timing Specifications Are Given For Reference Only, And No Guarantee is
Implied.
82C284 Timing
10MHz
SYMBOL
PARAMETER
12.5MHz
MIN
MAX
MIN
MAX
UNIT
TEST CONDITION
TIMING REQUIREMENTS
11
SRDY/SRDYEN Setup Time
15
-
15
-
ns
12
SRDY/SRDYEN Hold Time
2
-
2
-
ns
13
ARDY/ARDYEN Setup Time
5
-
5
-
ns
(Note 1)
14
ARDY/ARDYEN Hold Time
30
-
25
-
ns
(Note 1)
0
20
0
16
ns
CL = 75pF, IOL = 5mA,
IOH = -1mA
TIMING RESPONSES
19
PCLK Delay
NOTE:
1. These times are given for testing purposes to ensure a predetermined action.
82C288 Timing
10MHz
SYMBOL
PARAMETER
12.5MHz
MIN
MAX
MIN
MAX
UNIT
TEST CONDITION
TIMING REQUIREMENTS
12
CMDLY Setup Time
15
-
15
-
ns
13
CMDLY Hold Time
1
-
1
-
ns
TIMING RESPONSES
16
ALE Active Delay
1
16
1
16
ns
17
ALE Inactive Delay
-
19
-
19
ns
19
DT/R Read Active Delay
-
23
-
23
ns
CL = 150pF
20
DEN Read Active Delay
0
21
0
21
ns
IOL = 16mA Max
21
DEN Read Inactive Delay
3
23
3
21
ns
IOH = -1mA Max
22
DT/R Read Inactive Delay
5
24
5
18
ns
23
DEN Write Active Delay
-
23
-
23
ns
24
DEN Write Inactive Delay
3
23
3
23
ns
29
Command Active Delay from CLK
3
21
3
21
ns
CL = 300pF
30
Command Inactive Delay from CLK
3
20
3
20
ns
IOL = 32mA Max
133
80C286/883
AC Specifications
4.0V
3.6V
3.6V
CLK INPUT
1.0V
1.0V
0.45V
4.0V
3.6V
3.6V
CLK INPUT
1.0V
1.0V
0.45V
tSETUP
tHOLD
2.4V
2.0V
2.0V
0.8V
0.8V
OTHER
DEVICE
INPUT
0.4V
tDELAY (MAX)
tDELAY (MIN)
2.0V
DEVICE
OUTPUT
0.8V
NOTE:
1. For AC testing, input rise and fall times are driven at 1ns per volt.
FIGURE 1. AC DRIVE AND MEASURE POINTS - CLK INPUT
134
80C286/883
135
80C286/883
Waveforms
READ CYCLE
ILLUSTRATED WITH ZERO
WAIT STATES
TS
TC
TI
BUS CYCLE TYPE
VOH
3
1
φ2
φ2
φ1
WRITE CYCLE
ILLUSTRATED WITH ONE
WAIT STATE
TS
TC
φ2
φ1
φ2
φ1
READ
(TI OR TS)
TC
φ2
φ1
φ2
φ1
CLK
2
12A
12B
VOL
S1 • S0
19
19
80C286/883
13
A23 - A0
M/IO,
COD INTA
13
VALID ADDRESS
VALID ADDRESS
13
VALID CONTROL
BHE, LOCK
VALID IF TS
13
VALID CONTROL
9
14
15
8
VALID WRITE DATA
D15 - D0
VALID READ DATA
11
11
10
10
READY
12
82C284 (SEE NOTE 2)
11
SRDY +
SRDYEN
19
14
13
ARDY +
ARDYEN
19
19
16
17
20
PCLK
ALF
12
13
13
12
13
12
82C288 (SEE NOTE 2)
CMDLY
29
30
MWTC
29
30
(SEE NOTE 1)
MRDC
19
DT/R
22
20
21
23
DEN
NOTES:
1. The modified timing is due to the CMDLY signal being active.
2. 82C254 and 82C288 Timing Waveforms are shown for reference only, and no guarantee is inplied.
FIGURE 2. MAJOR CYCLE TIMING
136
24
80C286/883
Waveforms
(Continued)
BUS CYCLE TYPE
VCH
TX
φ1
VCH
φ2
CLK
φ2
TX
φ1
VCL
19
VCL
19
PCLK
(SEE NOTE 1)
7
(SEE NOTE 1)
6
RESET
5
INTR, NMI
HOLD, PEREQ
(SEE NOTE 2)
4
φ2
φ1
CLK
4
VCH
TX
φ2
φ1
φ2
CLK
VCL
5
7
6
(SEE NOTE 1)
RESET
ERROR, BUSY
(SEE NOTE 2)
NOTES:
1. PCLK indicates which processor cycle phase will occur on the
next CLK. PCLK may not indicate the correct phase until the first
cycle is performed.
NOTE:
2. These inputs are asynchronous. The setup and hold times shown
assure recognition for testing purposes.
1. When RESET meets the setup time shown, the next CLK will
start or repeat φ1 of a processor cycle.
FIGURE 3. 80C286/883 ASYNCHRONOUS INPUT SIGNAL
TIMING
FIGURE 4. 80C286/883 RESET INPUT TIMING AND SUBSEQUENT PROCESSOR CYCLE PHASE
137
80C286/883
Waveforms
(Continued)
BUS CYCLE TYPE
φ1
VCH
TH
φ2
TH OR TI
φ1
φ2
φ1
TI
φ2
φ1
TH
φ2
CLK
VCL
HILDA
16
16
(SEE NOTE 4)
12A (NOTE 3)
80C286/883
S1 • S0
15
(SEE NOTE 3)
IF TS
12B
15
PEACK
IF NPX TRANSFER
BHE, LOCK
A23 - A0,
M/IO,
COD/INTA
(SEE NOTE 1)
13
15
(SEE NOTE 5)
VALID
(SEE NOTE 2)
15
14
D15 - D0
(SEE NOTE 6)
80C284
VALID IF WRITE
PCLK
NOTES:
1.
2.
3.
4.
5.
6.
These signals may not be driven by the 80C286/883 during the time shown. The worst case in terms of latest float time is shown.
The data bus will be driven as shown if the last cycle before TI in the diagram was a write TC.
The 80C286/883 puts its status pins in a high impedance logic one state during TH.
For HOLD request set up to HLDA, refer to Figure 8.
BHE and LOCK are driven at this time but will not become valid until TS.
The data bus will remain in a high impedance state if a read cycle is performed.
FIGURE 5. EXITING AND ENTERING HOLD
138
80C286/883
Waveforms
(Continued)
BUS CYCLE TYPE
VCH
TI
φ2
TS
φ1
φ2
1
TC
φ2
TS
φ1
φ2
φ1
TC
φ2
TI
φ1
CLK
VCL
I/0 READ IF PROC. EXT. TO MEMORY
MEMORY READ IF MEMORY TO PROC. EXT
S1 • S0
CLK
A23 -A0
M/IO,
COD INTA
MEMORY WRITE IF PROC. EXT. TO MEMORY
I/O WRITE IF MEMORY TO PROC. EXT.
MEMORY ADDRESS IF PROC. EXT. TO MEMORY TRANSFER I/O
PORT ADDRESS 00FA(H) IF MEMORY TO PROC. EXT. TRANSFER
12A
I/O PORT ADDRESS 00FA(H) IF PROC. EXT. TO MEMORY TRANSFER
MEMORY ADDRESS IF MEMORY TO PROC. EXT. TRANSFER
12B
PEACK
(SEE NOTE 1)
5
(SEE NOTE 2)
4
PEREQ
NOTES:
1. PEACK always goes active during the first bus operation of a processor extension data operand transfer sequence. The first bus operation
will be either a memory read at operand address or I/O read at port address 00FA(H).
2. To prevent a second processor extension data operand transfer, the worst case maximum time (shown above) is 3 x 1 - 12A MAX -(4)MIN
The actual, configuration dependent, maximum time is: 3 x 1 - 12AMAX - (4)MIN +N x 2 x (1). N is the number of extra TC states added
to either the first or second bus operation of the processor extension data operand transfer sequence.
FIGURE 6. 80C286/883 PEREQ/PEACK TIMING FOR ONE TRANSFER ONLY
BUS CYCLE TYPE
VCH
φ2
φ1
TX
φ2
φ1
TX
φ2
TX
φ1
φ2
φ1
TI
φ2
CLK
VCL
6
(SEE NOTE 2)
(SEE NOTE 1)
AT LEAST
16 CLK PERIODS
RESET
6
7
12B
S1 • S0
UNKNOWN
PEACK
13
A23 - A0
BHE
UNKNOWN
13
M/IO
COD/INTA
UNKNOWN
13
LOCK
UNKNOWN
15
(SEE NOTE 3)
DATA
16
HILDA
UNKNOWN
NOTES:
1. Setup time for RESET ↑ may be violated with the consideration that φ1 of the processor clock may begin one system CLK period later.
2. Setup and hold times for RESET ↓ must be met for proper operation, but RESET ↓ may occur during φ1 or φ2.
3. The data bus is only guaranteed to be in a high impedance state at the time shown.
FIGURE 7. INITIAL 80C286/883 PIN STATE DURING RESET
BUS HOLD ACKNOWLEDGE
BUS HOLD
ACKNOWLEDGE
WRITE CYCLE
BUS CYCLE TYPE
TH
φ1
CLK
TH
φ2
φ1
TS
TH
φ2
φ1
φ2
φ1
TC
φ2
φ1
TC
φ2
φ1
TC
φ2
φ1
139
(SEE NOTE 5)
TI
φ2
φ1
TH
φ2
φ1
φ2
80C286/883
Die Characteristics
DIE DIMENSIONS:
286 x 283 x 19 ±1mils
METALLIZATION:
Type: Si-Al
Thickness: 8kÅ
GLASSIVATION:
Type: Nitrox
Thickness: 10kÅ
WORST CASE CURRENT DENSITY: 2 X 105A/cm2
LEAD TEMPERATURE: (10s Soldering): ≤ 300oC
Metallization Mask Layout
80C286/883
All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems.
Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without
notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and
reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
Spec Number
140
Similar pages