Red Lion NTCD-128 Managed industrial ethernet switch Datasheet

7506GX2 Industrial Ethernet Switch
N-Tron Networking Series
Managed
Industrial
Ethernet
THE INDUSTRIAL
NETWORK
COMPANY
7506GX2
Switch
PRODUCT FEATURES
• Four 10/100/1000BaseT(X) RJ-45 Ports
• Two SFP (Mini-GBIC) Gigabit Transceivers
(Optional)
• 1000BaseSX/LX Fiber with LC style connectors or
• 1000BaseT Copper with RJ-45 connectors
• -40o to 80oC Operating temperature
• ESD and Surge Protection Diodes on all Ports
• Auto Sensing 10/100/1000BaseT(X),
Duplex, and MDIX
• Store-and-forward Technology
• Jumbo Frame Support
• Rugged DIN-Rail Enclosure
• Onboard Temperature Sensor
• Redundant Power Inputs (10-49VDC)
• Configurable Bi-Color Fault Status LED
Fully Managed Features:
• SNMP v1, v2, v3 and Web Browser Management
• Configuration backup via Optional SD card
• EtherNet/IP™ CIP Messaging
• Detailed Ring Map and Fault Location Charting
• N-Ring™ Technology with ~30ms Healing
• N-View™ OPC Monitoring
• N-Link™ Redundant N-Ring Coupling
• IGMP Auto Configuration
• 802.1Q tag VLAN and Port VLAN
• 802.1p QoS and Port QoS, and DSCP
• LLDP (Link Layer Discovery Protocol)
• Port Trunking
• Port Mirroring
• 802.1d, 802.1w, 802.1D RSTP
• DHCP Server, Option 82 relay, Option 61, IP Fallback
• Local Port IP Addressing
• Port Security—MAC Address Based
Remote Monitoring Options - For ease of configuration and
monitoring, the 7506GX2 offers web browser management and
N-View OLE for process control (OPC) server software. The
N-TRON N-View software can be combined with popular HMI
software packages to add network traffic monitoring, trending,
and alarming to any application using N-TRON switches. In
addition, SNMP is available for switch link and status monitoring.
The status LED can be configured to respond to power failure on
power input 1 or input 2, N-Link fault, port usage fault, N-Ring
broken, partial break high, partial break low, or if multiple ring
managers are detected.
N-Ring Technology - N-TRON's 7506GX2 ring manager using
N-TRON's N-Ring technology offers expanded ring size capacity,
detailed fault diagnostics, and a standard healing time of ~30ms.
The 7506GX2 ring manager periodically checks the health of the
ring via heart beat packets. If the ring manager stops receiving these
health check packets, it converts the ring to a linear topology within
~30ms. When all switches in the ring are N-TRON fully managed
switches, a detailed ring map and fault location chart will also be
provided on the ring manager’s web browser and OPC server to
identify the health status of the ring. N-Link™ allows the linking
of two N-Rings. Up to 250 fully managed N-TRON switches can
participate in N-Ring topologies.
Industrial Packaging and Specifications - The 7506GX2 is
designed to operate in industrial environments. It is housed in a
rugged extruded aluminum DIN-Rail enclosure. It has extended
industrial specifications and features to meet or exceed the operating
parameters of connected equipment. These include extended
temperature ratings, extended shock and vibration specs, redundant
power inputs, and high MTBF (greater than 2M hours).
Ease of Use - The 10/100/1000BaseT(X) ports are auto sensing
and auto configuring. Each copper port is automatically negotiated
for maximum speed and performance by default, but can also be
hard coded through the user interface. A high speed processor
allows wire speed capability on all 10/100/1000BaseT(X) ports
simultaneously.
7506GX2 Specifications
THE INDUSTRIAL NETWORK COMPANY
7506GX2 Specifications
Switch Properties
Number of MAC Addresses:
Aging Time:
Latency Typical:
Switching Method:
Case Dimensions
Height:
Width:
Depth:
Weight (max):
DIN-Rail Mount:
Electrical
Redundant Input Voltage:
Input Current (max):
BTU/hr:
N-TRON Power Supply:
Environmental
Operating Temperature:
Storage Temperature:
Operating Humidity:
Operating Altitude:
4000
Programmable
1.6 μs
Store-and-Forward
SFP Gigabit Fiber Transceiver Characteristics
550m for 50/125μm
275m for 62.5/125μm*
10km**
TX Power Min
-9.5dBm
-9.5dBm
-2dBm
0dBm
RX Sensitivity Max
-17dBm
850nm
-20dBm
1310nm
-22dBm
1310nm
-24dBm
1550nm
Fiber Length
Wavelength
3.8"
2.0"
3.9"
1.1lbs
35mm
(9.6cm)
(5.1cm)
(9.9cm)
(0.48kg)
Assumed Fiber Loss
3.5 to 3.75 dB/km
Laser Type
40km**
80km**
0.45 dB/km 0.35 dB/km 0.25 dB/km
VCSEL
FP
DFB
DFB
* SX Fiber Optic Cable
** LX Fiber Optic Cable
Network Media
10BaseT:
100BaseTX:
1000BaseT:
>Cat3 Cable
>Cat5 Cable
>Cat5e Cable
10-49 VDC (Regulated)
440mA max.@24VDC
36@24VDC
Connectors
NTPS-24-1.3 (1.3A@24V) 10/100/1000BaseT(X):Four (4) RJ-45 Copper Ports
1000BaseT:
Up to Two (2) RJ-45 Gigabit
Copper Ports (optional)
-40oC to 80oC
1000BaseSX/LX:
Up to Two (2) LC Duplex Gigabit
-40oC to 85oC
Fiber Ports (optional)
5% to 95%
(Non Condensing)
0 to 10,000 ft.
Regulatory Approvals
Shock and Vibration (bulkhead mounted)
FCC Title 47, Part 15, Subpart B - Class A;
Reliability
UL /cUL: Class I, Div 2, Groups A, B, C, D and T4
ANSI/ISA 12.12.01-2007
Shock:
Vibration/Seismic:
MTBF:
200g @ 10ms
50g, 5-200Hz, Triaxial
ICES-003 - Class A
>2 Million Hours
CE: EN61000-6-2:2001; EN61000-6-4:2007
Recommended Wiring Clearance
Front:
Top:
4"
1"
(10.16 cm)
(2.54 cm)
EN61000-4-2, 3, 4, 5, 6
GOST-R Certied, RoHS Compliant
Designed to comply with:
IEEE 1613 for Electric Utility Substations
NEMA TS1/ TS2 for Trafc control
Contact Information
N-TRON Corp.
820 S. University Blvd., Suite 4E
Mobile, AL 36609 USA
TEL: (251) 342-2164
FAX: (251) 342-6353
Website: www.N-TRON.com
Email: [email protected]
N-TRON Asia
Suite #: 2267, 22/F, One Lujiazui
68 Yin Cheng Road Center,
Pudong New Area
200120 Shanghai, P.R. China
Phone: +86 (0) 21 6194 6777
Fax: +86 (0) 21 6194 6699
N-TRON Europe GmbH
Alte Steinhauserstr 19
6330 Cham / Zg Switzerland
TEL: +41 41 7406636
FAX: +41 41 7406637
REV 100408
® 2010 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Product names mentioned herein are for identification purposes only and may be
trademarks and/or registered trademarks of their respective company. Specifications subject to change without notice. The responsibility for the use and application of N-TRON
products rests with the end user. N-TRON makes no warranties as to the fitness or suitability of any N-TRON product for any specific application. N-TRON Corporation shall not
be liable for any damage resulting from the installation, use, or misuse of this product. Printed in USA.
7506GX2 Specifications
THE INDUSTRIAL NETWORK COMPANY
THE INDUSTRIAL NETWORK COMPANY
7506GX2 Industrial Ethernet Switch Ordering Information
7506GX2
Four 10/100/1000BaseT(X) Ports and two SFP ports without (optional) modules
7506GX2 Four
Industrial
Ethernet Switch
Information
7506GX2-SX
10/100/1000BaseT(X)
PortsOrdering
and two SFP
ports with 2 NTSFP-SX Multimode modules installed
7506GX2
Four
10/100/1000BaseT(X)
Ports
and
two
SFP
ports
without
modules Singlemode modules installed
7506GX2-LX-10 Four 10/100/1000BaseT(X) Ports and two SFP ports
with(optional)
2 NTSFP-LX-10
7506GX2-SX
Four 10/100/1000BaseT(X) Ports and two SFP ports with 2 NTSFP-SX Multimode modules installed
NTSFP-TX
Optional SFP (Mini-GBIC) Transceiver with One 1000BaseT GB Copper Port
7506GX2-LX-10 Four 10/100/1000BaseT(X) Ports and two SFP ports with 2 NTSFP-LX-10 Singlemode modules installed
NTSFP-SX
Optional
SFP
(Mini-GBIC)
with
One
1000BaseSX
Multimode
GB Fiber Optic Port
NTSFP-TX
Optional
SFP
(Mini-GBIC) Transceiver
Transceiver with
One
1000BaseT
GB Copper
Port
NTSFP-LX-ZZ
SFP
(Mini-GBIC)
withOne
One1000BaseSX
1000BaseLX
Singlemode
GBOptic
Fiber
Optic Port
NTSFP-SX Optional
Optional
SFP
(Mini-GBIC)Transceiver
Transceiver with
Multimode
GB Fiber
Port
NTCD-128
Optional
SDSFP
Card,
Conguration
Device
NTSFP-LX-ZZ
Optional
(Mini-GBIC)
Transceiver
with One 1000BaseLX Singlemode GB Fiber Optic Port
NTCD-128 N-TRON
Optional
SD Card,
Con-guration
Device
NTPS-24-1.3
Power
Supply
(1.3 Amp
@ 24VDC)
NTPS-24-1.3Panel
N-TRON
1000-PM
MountPower
kit Supply - (1.3 Amp @ 24VDC)
1000-PM
Panel Mount kit
URMK
Universal Rack Mount Kit
URMK
Universal Rack Mount Kit
Where:
ZZ = 10, 40, or 80 for GB Singlemode
Where: ZZ = 10, 40, or 80 for GB Singlemode
® 2010 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Specifications subject to change without notice. Printed in USA.
Americas
[email protected]
As the global experts in communication, monitoring and control for
industrial automation and networking, Red Lion has been delivering
innovative solutions for over forty years. Our automation, Ethernet and
Asia-Pacific
cellular M2M technology enables companies worldwide to gain real-time
® 2010 N-TRON, Corp. N-TRON and the N-TRON [email protected]
logo are trademarks of N-TRON, Corp.
cations
subject
to change
without notice.
Printed
in USA.
dataSpecifi
visibility
that
drives
productivity.
Product
brands
include Red Lion,
N-Tron and Sixnet. With headquarters in York, Pennsylvania, the company
Europe
has offices across the Americas, Asia-Pacific and Europe. Red Lion is
Middle East
part of Spectris plc, the productivity-enhancing instrumentation and
Africa
w w w. re d l i o n . n e t
controls company. For more information, please visit www.redlion.net.
[email protected]
Connect. Monitor. Control.
+1 (717) 767-6511
ADLD0261 080116 © 2016 Red Lion Controls, Inc. All rights reserved. Red Lion, the Red Lion logo, N-Tron and Sixnet are
registered trademarks of Red Lion Controls, Inc. All other company and product names are trademarks of their respective owners.
Similar pages