7506GX2 Industrial Ethernet Switch N-Tron Networking Series Managed Industrial Ethernet THE INDUSTRIAL NETWORK COMPANY 7506GX2 Switch PRODUCT FEATURES • Four 10/100/1000BaseT(X) RJ-45 Ports • Two SFP (Mini-GBIC) Gigabit Transceivers (Optional) • 1000BaseSX/LX Fiber with LC style connectors or • 1000BaseT Copper with RJ-45 connectors • -40o to 80oC Operating temperature • ESD and Surge Protection Diodes on all Ports • Auto Sensing 10/100/1000BaseT(X), Duplex, and MDIX • Store-and-forward Technology • Jumbo Frame Support • Rugged DIN-Rail Enclosure • Onboard Temperature Sensor • Redundant Power Inputs (10-49VDC) • Configurable Bi-Color Fault Status LED Fully Managed Features: • SNMP v1, v2, v3 and Web Browser Management • Configuration backup via Optional SD card • EtherNet/IP™ CIP Messaging • Detailed Ring Map and Fault Location Charting • N-Ring™ Technology with ~30ms Healing • N-View™ OPC Monitoring • N-Link™ Redundant N-Ring Coupling • IGMP Auto Configuration • 802.1Q tag VLAN and Port VLAN • 802.1p QoS and Port QoS, and DSCP • LLDP (Link Layer Discovery Protocol) • Port Trunking • Port Mirroring • 802.1d, 802.1w, 802.1D RSTP • DHCP Server, Option 82 relay, Option 61, IP Fallback • Local Port IP Addressing • Port Security—MAC Address Based Remote Monitoring Options - For ease of configuration and monitoring, the 7506GX2 offers web browser management and N-View OLE for process control (OPC) server software. The N-TRON N-View software can be combined with popular HMI software packages to add network traffic monitoring, trending, and alarming to any application using N-TRON switches. In addition, SNMP is available for switch link and status monitoring. The status LED can be configured to respond to power failure on power input 1 or input 2, N-Link fault, port usage fault, N-Ring broken, partial break high, partial break low, or if multiple ring managers are detected. N-Ring Technology - N-TRON's 7506GX2 ring manager using N-TRON's N-Ring technology offers expanded ring size capacity, detailed fault diagnostics, and a standard healing time of ~30ms. The 7506GX2 ring manager periodically checks the health of the ring via heart beat packets. If the ring manager stops receiving these health check packets, it converts the ring to a linear topology within ~30ms. When all switches in the ring are N-TRON fully managed switches, a detailed ring map and fault location chart will also be provided on the ring manager’s web browser and OPC server to identify the health status of the ring. N-Link™ allows the linking of two N-Rings. Up to 250 fully managed N-TRON switches can participate in N-Ring topologies. Industrial Packaging and Specifications - The 7506GX2 is designed to operate in industrial environments. It is housed in a rugged extruded aluminum DIN-Rail enclosure. It has extended industrial specifications and features to meet or exceed the operating parameters of connected equipment. These include extended temperature ratings, extended shock and vibration specs, redundant power inputs, and high MTBF (greater than 2M hours). Ease of Use - The 10/100/1000BaseT(X) ports are auto sensing and auto configuring. Each copper port is automatically negotiated for maximum speed and performance by default, but can also be hard coded through the user interface. A high speed processor allows wire speed capability on all 10/100/1000BaseT(X) ports simultaneously. 7506GX2 Specifications THE INDUSTRIAL NETWORK COMPANY 7506GX2 Specifications Switch Properties Number of MAC Addresses: Aging Time: Latency Typical: Switching Method: Case Dimensions Height: Width: Depth: Weight (max): DIN-Rail Mount: Electrical Redundant Input Voltage: Input Current (max): BTU/hr: N-TRON Power Supply: Environmental Operating Temperature: Storage Temperature: Operating Humidity: Operating Altitude: 4000 Programmable 1.6 μs Store-and-Forward SFP Gigabit Fiber Transceiver Characteristics 550m for 50/125μm 275m for 62.5/125μm* 10km** TX Power Min -9.5dBm -9.5dBm -2dBm 0dBm RX Sensitivity Max -17dBm 850nm -20dBm 1310nm -22dBm 1310nm -24dBm 1550nm Fiber Length Wavelength 3.8" 2.0" 3.9" 1.1lbs 35mm (9.6cm) (5.1cm) (9.9cm) (0.48kg) Assumed Fiber Loss 3.5 to 3.75 dB/km Laser Type 40km** 80km** 0.45 dB/km 0.35 dB/km 0.25 dB/km VCSEL FP DFB DFB * SX Fiber Optic Cable ** LX Fiber Optic Cable Network Media 10BaseT: 100BaseTX: 1000BaseT: >Cat3 Cable >Cat5 Cable >Cat5e Cable 10-49 VDC (Regulated) 440mA max.@24VDC 36@24VDC Connectors NTPS-24-1.3 (1.3A@24V) 10/100/1000BaseT(X):Four (4) RJ-45 Copper Ports 1000BaseT: Up to Two (2) RJ-45 Gigabit Copper Ports (optional) -40oC to 80oC 1000BaseSX/LX: Up to Two (2) LC Duplex Gigabit -40oC to 85oC Fiber Ports (optional) 5% to 95% (Non Condensing) 0 to 10,000 ft. Regulatory Approvals Shock and Vibration (bulkhead mounted) FCC Title 47, Part 15, Subpart B - Class A; Reliability UL /cUL: Class I, Div 2, Groups A, B, C, D and T4 ANSI/ISA 12.12.01-2007 Shock: Vibration/Seismic: MTBF: 200g @ 10ms 50g, 5-200Hz, Triaxial ICES-003 - Class A >2 Million Hours CE: EN61000-6-2:2001; EN61000-6-4:2007 Recommended Wiring Clearance Front: Top: 4" 1" (10.16 cm) (2.54 cm) EN61000-4-2, 3, 4, 5, 6 GOST-R Certied, RoHS Compliant Designed to comply with: IEEE 1613 for Electric Utility Substations NEMA TS1/ TS2 for Trafc control Contact Information N-TRON Corp. 820 S. University Blvd., Suite 4E Mobile, AL 36609 USA TEL: (251) 342-2164 FAX: (251) 342-6353 Website: www.N-TRON.com Email: [email protected] N-TRON Asia Suite #: 2267, 22/F, One Lujiazui 68 Yin Cheng Road Center, Pudong New Area 200120 Shanghai, P.R. China Phone: +86 (0) 21 6194 6777 Fax: +86 (0) 21 6194 6699 N-TRON Europe GmbH Alte Steinhauserstr 19 6330 Cham / Zg Switzerland TEL: +41 41 7406636 FAX: +41 41 7406637 REV 100408 ® 2010 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Product names mentioned herein are for identification purposes only and may be trademarks and/or registered trademarks of their respective company. Specifications subject to change without notice. The responsibility for the use and application of N-TRON products rests with the end user. N-TRON makes no warranties as to the fitness or suitability of any N-TRON product for any specific application. N-TRON Corporation shall not be liable for any damage resulting from the installation, use, or misuse of this product. Printed in USA. 7506GX2 Specifications THE INDUSTRIAL NETWORK COMPANY THE INDUSTRIAL NETWORK COMPANY 7506GX2 Industrial Ethernet Switch Ordering Information 7506GX2 Four 10/100/1000BaseT(X) Ports and two SFP ports without (optional) modules 7506GX2 Four Industrial Ethernet Switch Information 7506GX2-SX 10/100/1000BaseT(X) PortsOrdering and two SFP ports with 2 NTSFP-SX Multimode modules installed 7506GX2 Four 10/100/1000BaseT(X) Ports and two SFP ports without modules Singlemode modules installed 7506GX2-LX-10 Four 10/100/1000BaseT(X) Ports and two SFP ports with(optional) 2 NTSFP-LX-10 7506GX2-SX Four 10/100/1000BaseT(X) Ports and two SFP ports with 2 NTSFP-SX Multimode modules installed NTSFP-TX Optional SFP (Mini-GBIC) Transceiver with One 1000BaseT GB Copper Port 7506GX2-LX-10 Four 10/100/1000BaseT(X) Ports and two SFP ports with 2 NTSFP-LX-10 Singlemode modules installed NTSFP-SX Optional SFP (Mini-GBIC) with One 1000BaseSX Multimode GB Fiber Optic Port NTSFP-TX Optional SFP (Mini-GBIC) Transceiver Transceiver with One 1000BaseT GB Copper Port NTSFP-LX-ZZ SFP (Mini-GBIC) withOne One1000BaseSX 1000BaseLX Singlemode GBOptic Fiber Optic Port NTSFP-SX Optional Optional SFP (Mini-GBIC)Transceiver Transceiver with Multimode GB Fiber Port NTCD-128 Optional SDSFP Card, Conguration Device NTSFP-LX-ZZ Optional (Mini-GBIC) Transceiver with One 1000BaseLX Singlemode GB Fiber Optic Port NTCD-128 N-TRON Optional SD Card, Con-guration Device NTPS-24-1.3 Power Supply (1.3 Amp @ 24VDC) NTPS-24-1.3Panel N-TRON 1000-PM MountPower kit Supply - (1.3 Amp @ 24VDC) 1000-PM Panel Mount kit URMK Universal Rack Mount Kit URMK Universal Rack Mount Kit Where: ZZ = 10, 40, or 80 for GB Singlemode Where: ZZ = 10, 40, or 80 for GB Singlemode ® 2010 N-TRON, Corp. N-TRON and the N-TRON logo are trademarks of N-TRON, Corp. Specifications subject to change without notice. Printed in USA. Americas [email protected] As the global experts in communication, monitoring and control for industrial automation and networking, Red Lion has been delivering innovative solutions for over forty years. Our automation, Ethernet and Asia-Pacific cellular M2M technology enables companies worldwide to gain real-time ® 2010 N-TRON, Corp. N-TRON and the N-TRON [email protected] logo are trademarks of N-TRON, Corp. cations subject to change without notice. Printed in USA. dataSpecifi visibility that drives productivity. Product brands include Red Lion, N-Tron and Sixnet. With headquarters in York, Pennsylvania, the company Europe has offices across the Americas, Asia-Pacific and Europe. Red Lion is Middle East part of Spectris plc, the productivity-enhancing instrumentation and Africa w w w. re d l i o n . n e t controls company. For more information, please visit www.redlion.net. [email protected] Connect. Monitor. Control. +1 (717) 767-6511 ADLD0261 080116 © 2016 Red Lion Controls, Inc. All rights reserved. Red Lion, the Red Lion logo, N-Tron and Sixnet are registered trademarks of Red Lion Controls, Inc. All other company and product names are trademarks of their respective owners.