M Series 50 Watt DC-DC Converters Wide input voltage from 8...372 V DC 1, 2 or 3 isolated outputs up to 48 V DC 4 kV AC I/O electric strength test voltage LGA • Rugged electrical and mechanical design • Outputs individually controlled with excellent dynamic properties • Operating ambient temperature range –40...71°C Selection chart Output 1 Output 2 Uo nom Io nom Uo nom Io nom [V DC] [A] [V DC] [A] 5.1 8 12 4 15 3.4 24 2 48 1 12 2 12 2 15 1.7 15 1.7 5.1 5 12 0.7 5.1 5 15 0.6 Output 3 Uo nom Io nom [V DC] [A] 12 0.7 15 0.6 Type Input voltage 8...35 V DC AM 1001-7R AM 1301-7R AM 1501-7R AM 1601-7R AM 1901-7R AM 2320-7 AM 2540-7 AM 3020-7 AM 3040-7 Type Type Input voltage Input voltage 14...70 V DC 20...100 V DC BM 1001-7R FM 1001-7R BM 1301-7R FM 1301-7R BM 1501-7R FM 1501-7R BM 1601-7R FM 1601-7R BM 1901-7R FM 1901-7R BM 2320-7 FM 2320-7 BM 2540-7 FM 2540-7 BM 3020-7 FM 3020-7 BM 3040-7 FM 3040-7 Output 1 Output 2 Uo nom Io nom Uo nom Io nom [V DC] [A] [V DC] [A] 5.1 8 12 4 15 3.4 24 2 48 1 12 2 12 2 15 1.7 15 1.7 5.1 5 12 0.7 5.1 5 15 0.6 Output 3 Type Type Type Uo nom Io nom Input voltage Input voltage Input voltage [V DC] [A] 28...140 V DC 44...220 V DC 88...372 V DC CM 1001-7R DM 1001-7R LM 1001-7R CM 1301-7R DM 1301-7R LM 1301-7R CM 1501-7R DM 1501-7R LM 1501-7R CM 1601-7R DM 1601-7R LM 1601-7R CM 1901-7R DM 1901-7R LM 1901-7R CM 2320-7 DM 2320-7 LM 2320-7 CM 2540-7 DM 2540-7 LM 2540-7 12 0.7 CM 3020-7 DM 3020-7 LM 3020-7 15 0.6 CM 3040-7 DM 3040-7 LM 3040-7 Options -9, P, D, V, A, H, F -9, P, D, A, H, F -9, P, D, A, H, F -9, P, D, A, H, F -9, P, D, A, H, F -9, P, D, A, H, F -9, P, D, A, H, F -9, P, D, V, A, H, F -9, P, D, V, A, H, F Options -9, E, P, D, V, A, H, F -9, E, P, D, A, H, F -9, E, P, D, A, H, F -9, E, P, D, A, H, F -9, E, P, D, A, H, F -9, E, P, D, A, H, F -9, E, P, D, A, H, F -9, E, P, D, V, A, H, F -9, E, P, D, V, A, H, F CM, DM and LM types available as CMZ, DMZ and LMZ class II equipment 2/12.2000 www.power-one.com 1 Cassette Style M Series Input Input voltage Inrush current limitation 6 wide-input ranges (1:5) CM, DM, LM by thermistor refer to selection chart Output Efficiency Output voltage setting accuracy Output voltage switching noise Line regulation Load regulation Minimum load Current limitation main output Current limitation aux. output(s) Operation in parallel Hold-up time Ui nom, Io nom up to 83% Ui nom, Io nom ±0.6% Uo nom IEC/EN 61204, total typ. 50 mVpp Ui min...Ui max, Io nom, each output regulated typ. ±0.3% Uo nom Ui nom, 0...Io nom, each output regulated typ. 0.15% Uo nom not required 0A rectangular U/I characteristic typ. 110% Io nom rectangular U/I characteristic typ. 120% Io nom by current limitation, only main outputs Ui nom, Io nom, LM typ. 100 ms Ui nom, Io nom, A/B/C/D/FM with ext. diode in input line up to 7 ms Protection Input reverse polarity Input undervoltage lockout Input overvoltage lockout Input transient protection Output Output overvoltage Overtemperature built-in fuse typ. 80% Ui min typ. 110% Ui max varistor or suppressor diode no-load, overload and short circuit proof suppressor diode in each output switch-off with auto restart typ. 150% Uo nom TC typ. 100°C Control Output voltage adjustment Inhibit Status indication single output types TTL input, output(s) disabled if open circuit LEDs: OK, inhibit, overload 0...110% Uo nom Safety Approvals Class of equipment Protection degree Electric strength test voltage www.power-one.com EN 60950, UL 1950, CSA C22.2 No. 950 AM, BM, CM, DM, FM, LM CMZ, DMZ, LMZ units without options class I, I/case class I, I/O class II, CMZ/DMZ/LMZ, I/O and I/case O/case O/O class I class II IP 40 2 kV AC 4 kV AC 4 kV AC 1 kV AC 0.2 kV AC 2 M Series 50 Watt DC-DC Converters EMC Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge Conducted disturbances Electromagnetic emissions IEC/EN 61000-4-2, level 4 (8/15 kV) IEC/EN 61000-4-3, level x (20 V/m) IEC/EN 61000-4-4, input, level 3/4 (2/4 kV) IEC/EN 61000-4-5, input, level 3/4 (2/4 kV) IEC/EN 61000-4-6, level 3 (10 V) CISPR 22/EN 55022, conducted criterion B criterion A/B criterion A/B criterion A criterion B class B Environmental Operating ambient temperature Operating case temperature TC Storage temperature Damp heat Vibration, sinusoidal Shock Bump Random vibration MTBF Ui nom, Io nom, convection cooled Ui nom, Io nom non operational IEC/EN 60068-2-3, 93%, 40°C IEC/EN 60068-2-6, 10...60/60...2000 Hz IEC/EN 60068-2-27, 6 ms IEC/EN 60068-2-29, 6 ms IEC/EN 60068-2-64, 20...500 Hz MIL-HDBK-217E, GB, 40°C, single output types –25...71°C –25...95°C –40...100°C 56 days 0.35 mm/5 gn 100 gn 40 gn 4.9 gn rms 320'000 h Options Extended temperature range –40...71°C, ambient, operating Electronic inrush current limitation Output voltage adjustment 95...105% Uo nom, excludes feature R and vice versa Input and/or output undervoltage monitoring, excludes option V Input and/or output undervoltage monitoring (VME), excludes option D Test sockets for check of output voltage Enhanced electric strength test 2 kV AC Fuse not user accessible -9 E P D0...D9 V0, V2, V3 A H F Pin allocation Pin Electrical determination 2 5 8 11 14 17 14 17 20 23 26 29 32 Inhibit control input Safe data or ACFAIL Output voltage (positive) Output voltage (negative) Control input + Control input – Output voltage (positive) Output voltage (negative) Output voltage (positive) Output voltage (negative) Protective earth DC input voltage DC input voltage www.power-one.com AM...LM 1000 i D or V Vo1+ Vo1– R G CMZ...LMZ 1000 i D or V Vo1+ Vo1– R G AM...LM 2000 i D or V CMZ...LMZ 2000 i D or V AM...LM 3000 i D or V Vo3+ Vo3– CMZ...LMZ 3000 i D or V Vo3+ Vo3– Vo2+ Vo2– Vo1+ Vo1– Vo2+ Vo2– Vo1+ Vo1– Vo2+ Vo2– Vo1+ Vo1– Vi+ Vi– Vi+ Vi– Vi+ Vi– Vo1+ Vo1– Vo1+ Vo1– Vo2+ Vo2– Vo1+ Vo1– Vi+ Vi– Vi+ Vi– Vi+ Vi– 3 Cassette Style M Series Mechanical data Tolerances ±0.3 mm (0.012") unless otherwise indicated. 8 11 14 17 20 23 26 29 32 S09012 5 103 22 (0.87") 173.7 (6.84") M 3; depth = 4 mm (chassis mount) Measuring point for case temperature TC 68 127 (5") 168.5 (6.63") 20 (0.79") 2TE 6TE 2 European Projection 111.2 (3U) (4.38") OK Inhibit i Potentiometer (option D) or potentiometer (option V) 38.7 (1.52") IoL Test sockets (option A) Potentiometer(s) (option P) Accessories Front panels 19” (Schroff/Intermas) Mating H11 connectors with screw, solder, fast-on or press-fit terminals Connector retention facilities and code key system for connector coding Flexible PCB for connecting the converter via an H11 connector, if mounted on a PCB Chassis or wall mounting plates for frontal access Universal mounting brackets for chassis or DIN-rail mounting www.power-one.com 4