Power-One HBD060YGE-A Hbd series - dual output, 60 watt Datasheet

(888) IPD-CONVerters ● (888) 473-2668 ● www.ipdconverters.com
HBD SERIES - DUAL OUTPUT, 60 WATT
DESCRIPTION
FEATURES
HBD dual output, DC/DC converters feature high
efficiency, 1500 VDC isolation, and open-frame
packaging. The HBD family allows board designers
to deliver any combination of power from
either output, up to each model’s maximum rating.
The HBD is available in 5V/3.3V or 3.3V/2.5V
combinations in either a 24V or 48V input version. The
HBD uses planar magnetics and has an MTBF of over a
million hours.
•
•
•
•
•
Independent Dual Outputs • Independent Trim
Flexible Load Sharing
For Each Output
High Efficiency Topology • 1500V Isolation
Open-Frame Design
• 100°C Baseplate
Planar Magnetics
Operation
Efficiency vs. Load (24V Input)
85
EFFICIENCY %
80
TECHNICAL SPECIFICATIONS
75
HBD060YGE-A
70
EFF. (18V)
EFF. (24V)
EFF. (36V)
65
Input
60
Voltage Range
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
Input Reverse Voltage Protection
10
18.00 - 36.00 VDC
34.00 - 75.00 VDC
80 mA
Shunt Diode
40
50
60
70
80
90
100
Efficiency vs. Load (48V Input)
85
±1%
0.2% Vout
1.0% Vout
0.5% Vout
1.0% Vout
10% Iout Rated
25% Iout
4% Vout
500 µs
±10%
110 - 140%
115 - 140% Vout Nom.
80
EFFICIENCY %
75
70
HBD060ZGE-A
65
HBD040ZGE-A
60
HBD040ZED-A
55
50
10
20
30
40
50
60
70
80
90
100
LOAD %
General
Turn-On Time
Remote Shutdown
Switching Frequency
Isolation
Input - Output
Input - Case
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Thermal Shutdown Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
MTBF† (Bellcore TR-NWT-000332)
Safety
Weight (approx.)
30
LOAD %
Output
Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated, Output 1
Line Regulation Vin Min. - Vin Max., Iout Rated, Output 2
Load Regulation Iout Min. - Iout Max., Vin Nom., Output 1
Load Regulation Iout Min. - Iout Max., Vin Nom., Output2
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range (5V/3.3V Units)
Power Limit Threshold Range, % of Iout Rated
OVP Trip Range (Main Ouput)
20
10 ms
Positive Logic
500 kHz
1500 VDC
1050 VDC
500 VDC
0.03%/°C
-40 To +100°C
-40 To +125°C
105 To 115°C
95%
5g
6
1.3 x 10 Hrs
UL, CUL, VDE
2.4 oz
1
Notes
1
For negative logic, add suffix “N” to model number.
†
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
HBD SERIES - DUAL OUTPUT, 60 WATT
MODELS - (See the last page of this file for options.)
Vin
(Volts)
Vin Range
(Volts)
Iin Max.*
(Amps)
Vout
(Volts)
Iout Rated
(Amps)
Ripple & Noise
Pk-Pk (mV)
Efficiency
Typ. **
Model
24
24
24
48
48
48
18 - 36
18 - 36
18 - 36
34 - 75
34 - 75
34 - 75
2.89
4.54
3.02
1.51
1.62
2.27
3.3/2.5
5.0/3.3
5.0/3.3
5.0/3.3
3.3/2.5
5.0/3.3
12/15
12/15
8/12
8/12
12/15
12/15
75/75
100/75
100/75
100/75
75/75
100/75
75%
78%
80%
80%
75%
79%
HBD040YED-A
HBD060YGE-A
HBD040YGE-A
HBD040ZGE-A
HBD040ZED-A
HBD060ZGE-A
Denotes advanced product release. Consult factory for product availability.
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
Note: Current can be drawn from either output to its maximum value, or from both outputs to a combined total of 15A.
MECHANICAL DRAWING
0.18"
2.28"
(4.6mm)
(57.9mm)
MOUNTING INSERTS
M3X.5 THROUGH 4PL
1.700"(43.2mm)
1.400"(35.6mm)
1
1.000"(25.4mm)
2
5
1.500"(38.1mm)
6
1.200"(30.5mm)
7
0.900"(22.9mm)
8
0.500"(12.7mm)
9
0.200"(5.1mm)
BOTTOM VIEW
DIA 0.040"
(1.0mm)
2.40"
(61.0mm)
0.400"(10.2mm)
3
0
4
-0.100"(-2.5mm)
10
-0.300"(-7.6mm)
-0.50"(-12.7mm)
.025" REF.
-0.19"
0
1.900"
Thermal Impedance
Natural Convection
100 LFM
200 LFM
300 LFM
400 LFM
6.6
5.7
4.2
3.1
2.6
°C/W
°C/W
°C/W
°C/W
°C/W
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated for
specific application.
(0.6mm)
(48.3mm)
(-4.8mm)
Pin
Function
1
2
3
4
5
6
7
8
9
10
-Vin
Case
On/Off
+Vin
+Vout 2
- Vout 2
Trim 2
+Vout 1
-V out 1
Trim 1
2
0.50"
(12.7mm)
Tolerances
Inches:
.XX ± 0.020
.XXX ± 0.010
Pin:
± 0.002
(Millimeters)
.X ± 0.5
.XX ± 0.25
± 0.05
(Dimensions as listed unless otherwise
specified.)
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION
SUFFIX
APPLICABLE SERIES
Negative Logic
N
HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQD
Lucent Compatible Trim
T
HAS, HBD, HBS, HES, QBS, QES
Terminal Strip
TS
REMARKS
TTL “Low” Turns Module ON
TTL “High” Turns Module OFF
XWS, XWD, XWT
Trim
1
IAS, LES
Enable
2
IAD, IAS, LES, SMS
Trim and Enable
3
IAS, LES
Current Share
4
SMS
Headerless
Y
Encapsulated EWS, IWS, OWS
PIN LENGTH AND HEATSINK
OPTIONS
Standard Pin Length is 0.180”
(4.6mm)
0.110” (2.8mm) Pin Length
8
All Units (Except SMS)
0.150” (3.8mm) Pin Length
9
All Units (Except SMS)
0.24” (6.1mm) Horizontal Heatsink
1H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.24” (6.1mm) Vertical Heatsink
1V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.45” (11.4mm) Horizontal
Heatsink
2H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.45” (11.4mm) Vertical Heatsink
2V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.95” (24.1mm) Horizontal
Heatsink
3H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.95” (24.1mm) Vertical Heatsink
3V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
3