AIMTEC AM2GW-2412D-NZ 2 watt | dc-dc converter Datasheet

Series AM2GW-NZ
2 Watt | DC-DC Converter
FEATURES:
• RoHS compliant
• Ultra wide 4:1 input range
• Remote On/Off Control
• 9 pin SIP package
•
•
•
•
Operating temperature -40oC to + 85oC
Continuous Short circuit protection
High efficiency up to 82%
Low ripple and noise
Models
Single output
Model
Input
Voltage (V)
Output
Voltage
(V)
Output Current
max
(mA)
Isolation
(VDC)
Max Capacitive
Load
(μF)
AM2GW-2403S-NZ
AM2GW-2405S-NZ
AM2GW-2409S-NZ
AM2GW-2412S-NZ
AM2GW-2415S-NZ
AM2GW-4803S-NZ
AM2GW-4805S-NZ
AM2GW-4809S-NZ
AM2GW-4812S-NZ
AM2GW-4815S-NZ
9-36
9-36
9-36
9-36
9-36
18-72
18-72
18-72
18-72
18-72
3.3
5
9
12
15
3.3
5
9
12
15
500
400
222
167
133
500
400
222
167
133
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1200
820
680
470
330
1200
820
680
470
330
Efficiency
73
75
78
82
81
72
76
78
81
80
Models
Dual output
Model
Input Voltage
(V)
Output
Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
Max Capacitive
Load
(μF)
Efficiency
(%)
AM2GW-2405D-NZ
AM2GW-2409D-NZ
AM2GW-2412D-NZ
AM2GW-2415D-NZ
AM2GW-4805D-NZ
AM2GW-4809D-NZ
AM2GW-4812D-NZ
AM2GW-4815D-NZ
9-36
9-36
9-36
9-36
18-72
18-72
18-72
18-72
±5
±9
±12
±15
±5
±9
±12
±15
±200
±111
±83
±67
±200
±111
±83
±67
1500
1500
1500
1500
1500
1500
1500
1500
±330
±270
±220
±180
±330
±270
±220
±180
76
78
82
81
75
77
81
80
Maximum
Units
Input Specifications
Parameters
Nominal
Typical
24
48
9-36
Voltage range
18-72
Filter
Capacitor
24 Vin
40
Maximum Rating
48 Vin
80
Peak Input Voltage time
100
On/Off Control
ON – low or open; OFF – high
On/Off input current
5
10
* Exceeding the maximum permissible value of 20mA for the Input On/Off current will damage the converter.
VDC
VDC
ms
mA
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
www.aimtec.com
F 051e R6.B
Conditions
Typical
60 sec
At 500VDC
> 1000
80
Tel: +1 514 620 2722
1 of 3
Rated
Units
1500
VDC
MOhm
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2GW-NZ
2 Watt | DC-DC Converter
Output Specifications
Parameters
Conditions
Voltage accuracy
Short Circuit protection
Short Circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Typical
Maximum
Units
±3
Continuous
Auto recovery
±0.75
±1.5
±0.03
100
LL~HL
Load 10~100%
At 20MHz Bandwidth
%
%
%
%/oC
mV p-p
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Temperature rise
Cooling
Humidity
Case material
Weight
Dimensions (L x H x W)
MTBF
Conditions
Typical
Maximum
Units
100% load, Vin nominal
With derating above 71oC
>100
550
KHz
o
C
o
C
o
C
-40 to +85
-50 to +125
Full load
15
Free air convection
35
%
95
Non-conductive black plastic (UL94V-0 rated)
7
g
1.02 x 0.37 x 0.49 inch
26.00 x 9.60 x 12.00 mm
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise
specified
Pin Out Specifications
Dimensions
26.00
(1.02)
Pin
Single
Dual
1
2
3
6
7
8
9
- V Input
+ V Input
On/Off Control
+ V Output
N.C.
N.C.
- V Output
- V Input
+ V Input
On/Off Control
+ V Output
Common
N.C.
- V Output
PRINTED
FACE
9.60
(0.37)
12.50
(0.49)
0.50
(0.02)
4.00
(0.16)
2.54
(0.10)
Derating
0.50
(0.02)
Free Air Convection
71º C
Output Power (%)
100
2.90
(0.11)
80
1
2
3
2.000
(0.079)
6
7
8
9
0.300
(0.012)
9.60
(0.37)
0.50
(0.02)
Safe Operating Area
60
40
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 051e R6.B
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM2GW-NZ
2 Watt | DC-DC Converter
Control ON/OFF pin connection example:
The voltage could be applied through a limiting resistor and a switching diode. The converter is in a low power mode during
high level phase.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R6.B
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages