TSC HS2F 2.0amps high efficient surface mount rectifier Datasheet

HS2A - HS2M
creat by ART
2.0AMPS High Efficient Surface Mount Rectifiers
SMB/DO-214AA
Pb
RoHS
COMPLIANCE
Features
—
Glass passivated junction chip.
—
For surface mounted application
—
Low forward voltage drop
—
Low profile package
—
Built-in stain relief, ideal for automatic
placement
—
Fast switching for high efficiency
—
High temperature soldering:
260℃/10 seconds at terminals
—
Plastic material used carries Underwriters
Laboratory Classification 94V-0
—
Green compound with suffix "G" on packing
code & prefix "G" on datecode
Mechanical Data
Dimensions in inches and (millimeters)
Marking Diagram
—
—
Cases: Molded plastic
Terminal: Pure tin plated, lead free
—
Polarity: Indicated by cathode band
G
= Green Compound
—
Packing: 12mm tape per EIA STD RS-481
Y
= Year
—
Weight: 0.093 grams
M
= Work Month
HS2X = Specific Device Code
Maximum Ratings and Electrical Characteristics
Rating at 25 ℃ ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
HS
2B
100
HS
2D
200
HS
2F
300
HS
2G
400
HS
2J
600
HS
2K
800
HS
2M
1000
Maximum Recurrent Peak Reverse Voltage
VRRM
HS
2A
50
Maximum RMS Voltage
VRMS
35
70
140
210
280
420
560
700
V
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
See Fig. 1
VDC
50
100
200
300
400
600
800
1000
V
Type Number
Peak Forward Surge Current, 8.3 ms Single Half Sinewave Superimposed on Rated Load (JEDEC method)
Maximum Instantaneous Forward Voltage (Note 1)
@2A
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@ T A=25 ℃
@ T A=125 ℃
Symbol
2
A
IFSM
50
A
VF
1.0
1.3
5
IR
uA
150
uA
50
75
Typical Junction Capacitance (Note 3)
Cj
50
30
Storage Temperature Range
RθJA
V
1.7
Trr
Operating Temperature Range
V
IF(AV)
Maximum Reverse Recovery Time (Note 2)
Maximum Thermal Resistance
Units
nS
pF
O
80
C/W
TJ
- 55 to + 150
O
C
TSTG
- 55 to + 150
O
C
Note 1: Pulse Test with PW=300 usec, 1% Duty Cycle
Note 2: Reverse Recovery Test Conditions: I F=0.5A, I R=1.0A, I RR=0.25A
Note 3: Measured at 1 MHz and Applied V R=4.0 Volts
Version:E11
RATINGS AND CHARACTERISTIC CURVES (HS2A THRU HS2M)
FIG.1- MAXIMUM FORWARD CURRENT DERATING
CURVE
2.5
2
1.5
1
0.5
0
0
25
50
75
100
125
150
175
LEAD TEMPERATURE (oC)
INSTANTANEOUS REVERSE CURRENT (uA)
AVERAGE FORWARD
CURRENT (A)
3
60
TA=100℃
100
10
TA=25℃
1
0.1
FIG. 3- MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
70
PEAK FORWARD SURGE
URRENT (A)
FIG. 2- TYPICAL REVERSE
CHARACTERISTICS
1000
0
20
40
60
80
100
120
PERCENT OF RATED PEAK REVERSE
VOLTAGE (%)
140
8.3mS Single Half Sine Wave
JEDEC Method
50
40
30
20
10
0
10
NUMBER OF CYCLES AT 60 Hz
100
FIG. 4- TYPICAL JUNCTION CAPACITANCE
175
JUNCTION CAPACITANCE (pF)
FIG. 5- TYPICAL INSTANTANEOUS
FORWARD CHARACTERISRICS
10
INSTANTANEOUS FORWARD CURRENT (A)
1
150
125
100
HS2A-HS2G
75
50
1
HS2A-HS2D
0.1
HS2G
0.01
HS2J-HS2M
HS2J-HS2M
25
0
0.1
1
10
REVERSE VOLTAGE (V)
100
1000
0.001
0
0.2
0.4
0.6
0.8
1
FORWARD VOLTAGE (V)
1.2
1.4
Version:E11
Similar pages