Finisar FTLX3812M320 Multiprotocol 10gb/s dwdm xfp optical transceiver Datasheet

Finisar
Product Specification
Multiprotocol 10Gb/s DWDM XFP Optical Transceiver
FTLX3812M3xx
PRODUCT FEATURES
•
Supports 9.95Gb/s to 11.1Gb/s
•
Hot-pluggable XFP footprint
•
Temperature-stabilized DWDM
EML transmitter
•
RoHS-6 Compliant (lead-free)
•
100GHz ITU Grid, C-Band
•
Duplex LC connector
•
Power dissipation <3.5W
•
Built-in digital diagnostic functions
•
Temperature range: -5°C to 70°C
APPLICATIONS
•
Amplified DWDM 10G SONET/SDH
•
Amplified DWDM 10G Ethernet
Finisar’s FTLX3812M3xx Small Form Factor 10Gb/s (XFP) transceiver complies with
the current XFP Multi-Source Agreement (MSA) Specification1. It supports amplified
DWDM 10Gb/s SONET/SDH and 10-Gigabit Ethernet applications. Digital diagnostics
functions are available via a 2-wire serial interface, as specified in the XFP MSA. For a
SONET-only version, please see FTLX3812S3xx. The transceiver is RoHS compliant
and lead free per Directive 2002/95/EC3, and Finisar Application Note AN-20384.
PRODUCT SELECTION
FTLX3812M3xx
xx: 100GHz ITU-T channel
(see next page)
© Finisar Corporation 11-January-2011
Rev C1
Page 1
FTLX3812M3xx Amplified DWDM XFP Product Specification – January 2011
Channel #
17*
18*
19*
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61*
Product Code
FTLX3812M317
FTLX3812M318
FTLX3812M319
FTLX3812M320
FTLX3812M321
FTLX3812M322
FTLX3812M323
FTLX3812M324
FTLX3812M325
FTLX3812M326
FTLX3812M327
FTLX3812M328
FTLX3812M329
FTLX3812M330
FTLX3812M331
FTLX3812M332
FTLX3812M333
FTLX3812M334
FTLX3812M335
FTLX3812M336
FTLX3812M337
FTLX3812M338
FTLX3812M339
FTLX3812M340
FTLX3812M341
FTLX3812M342
FTLX3812M343
FTLX3812M344
FTLX3812M345
FTLX3812M346
FTLX3812M347
FTLX3812M348
FTLX3812M349
FTLX3812M350
FTLX3812M351
FTLX3812M352
FTLX3812M353
FTLX3812M354
FTLX3812M355
FTLX3812M356
FTLX3812M357
FTLX3812M358
FTLX3812M359
FTLX3812M360
FTLX3812M361
Frequency (THz)
191.7
191.8
191.9
192.0
192.1
192.2
192.3
192.4
192.5
192.6
192.7
192.8
192.9
193.0
193.1
193.2
193.3
193.4
193.5
193.6
193.7
193.8
193.9
194.0
194.1
194.2
194.3
194.4
194.5
194.6
194.7
194.8
194.9
195.0
195.1
195.2
195.3
195.4
195.5
195.6
195.7
195.8
195.9
196.0
196.1
Finisar
Center Wavelength (nm)
1563.86
1563.05
1562.23
1561.42
1560.61
1559.79
1558.98
1558.17
1557.36
1556.55
1555.75
1554.94
1554.13
1553.33
1552.52
1551.72
1550.92
1550.12
1549.32
1548.51
1547.72
1546.92
1546.12
1545.32
1544.53
1543.73
1542.94
1542.14
1541.35
1540.56
1539.77
1538.98
1538.19
1537.40
1536.61
1535.82
1535.04
1534.25
1533.47
1532.68
1531.90
1531.12
1530.33
1529.55
1528.77
*This channel is supported with limited availability -- Please contact Finisar for further details.
© Finisar Corporation 11-January-2011
Rev C1
Page 2
FTLX3812M3xx Amplified DWDM XFP Product Specification – January 2011
I.
Finisar
Pin Descriptions
Pin
1
2
3
Logic
LVTTL-I
4
LVTTL-O
5
6
7
8
9
10
11
LVTTL-I
Symbol
GND
VEE5
Mod-Desel
Interrupt
TX_DIS
VCC5
GND
VCC3
VCC3
SCL
SDA
12
LVTTL-I
LVTTLI/O
LVTTL-O
Mod_Abs
13
LVTTL-O
Mod_NR
14
15
16
17
18
19
20
21
LVTTL-O
LVTTL-I
RX_LOS
GND
GND
RDRD+
GND
VCC2
P_Down/RST
22
23
24
PECL-I
VCC2
GND
RefCLK+
25
PECL-I
RefCLK-
26
27
28
29
30
CML-O
CML-O
CML-I
CML-I
GND
GND
TDTD+
GND
Name/Description
Module Ground
Optional –5.2 Power Supply – Not required
Module De-select; When held low allows the module to
respond to 2-wire serial interface commands
Interrupt (bar); Indicates presence of an important condition
which can be read over the serial 2-wire interface
Transmitter Disable; Transmitter laser source turned off
+5 Power Supply
Module Ground
+3.3V Power Supply
+3.3V Power Supply
Serial 2-wire interface clock
Serial 2-wire interface data line
Ref.
1
Module Absent; Indicates module is not present. Grounded
in the module.
Module Not Ready; Finisar defines it as a logical OR
between RX_LOS and Loss of Lock in TX/RX.
Receiver Loss of Signal indicator
Module Ground
Module Ground
Receiver inverted data output
Receiver non-inverted data output
Module Ground
+1.8V Power Supply
Power Down; When high, places the module in the low
power stand-by mode and on the falling edge of P_Down
initiates a module reset
Reset; The falling edge initiates a complete reset of the
module including the 2-wire serial interface, equivalent to a
power cycle.
+1.8V Power Supply
Module Ground
Reference Clock non-inverted input, AC coupled on the
host board – Not required
Reference Clock inverted input, AC coupled on the host
board – Not required
Module Ground
Module Ground
Transmitter inverted data input
Transmitter non-inverted data input
Module Ground
2
2
1
2
2
2
2
1
1
1
1
1
1
1
Notes:
1. Module circuit ground is isolated from module chassis ground within the module.
2. Open collector; should be pulled up with 4.7k – 10kohms on host board to a voltage between 3.15V
and 3.6V.
© Finisar Corporation 11-January-2011
Rev C1
Page 3
Finisar
FTLX3812M3xx Amplified DWDM XFP Product Specification – January 2011
Diagram of Host Board Connector Block Pin Numbers and Names
II.
Absolute Maximum Ratings
Parameter
Maximum Supply Voltage #1
Maximum Supply Voltage #2
Maximum Supply Voltage #3
Storage Temperature
Case Operating Temperature
Receiver Damage Threshold
© Finisar Corporation 11-January-2011
Symbol
Vcc3
Vcc5
Vcc5
TS
TOP
PRdmg
Min
-0.5
-0.5
-0.5
-40
-5
+1
Rev C1
Typ
Max
4.0
6.0
2.0
85
70
Unit
V
V
V
°C
°C
dBm
Ref.
Page 4
Finisar
FTLX3812M3xx Amplified DWDM XFP Product Specification – January 2011
III.
Electrical Characteristics (TOP = -5 to 70 °C, VCC5 = 4.75 to 5.25 Volts)
Parameter
Supply Voltage #1
Supply Voltage #2
Supply Voltage #3
Supply Current – Vcc5 supply
Supply Current – Vcc3 supply
Supply Current – Vcc2 supply
Module total power
Transmitter
Input differential impedance
Differential data input swing
Transmit Disable Voltage
Transmit Enable Voltage
Transmit Disable Assert Time
Receiver
Differential data output swing
Data output rise time
Data output fall time
LOS Fault
LOS Normal
Power Supply Rejection
Reference Clock
Clock differential input impedance
Reference Clock frequency
Differential clock input swing
Clock output rise/fall time
Reference clock frequency tolerance
Symbol
Vcc5
Vcc3
Vcc2
Icc5
Icc3
Icc2
P
Rin
Vin,pp
VD
VEN
Vout,pp
tr
tf
VLOS fault
VLOS norm
PSR
Rclkin
f0
Vclkin,pp
trf
Df
Min
4.75
3.13
1.71
Typ
Max
5.25
3.46
1.89
350
400
750
3.5
Unit
V
V
V
mA
mA
mA
W
Ω
mV
V
V
us
2
820
Vcc
GND+ 0.8
10
650
mV
ps
ps
V
V
4
5
5
6
6
7
100
Baud/64
Ω
MHz
mV
ps
PPM
100
120
2.0
GND
340
Vcc – 0.5
GND
640
200
-100
850
38
38
VccHOST
GND+0.5
See Note 6 below
1600
1250
+100
Ref.
1
3
5
Notes:
1. Maximum total power value is specified across the full temperature and voltage range.
2. After internal AC coupling.
3. Or open circuit.
4. Into 100 ohms differential termination.
5. 20 – 80 %
6. Loss Of Signal is open collector to be pulled up with a 4.7k – 10kohm resistor to 3.15 – 3.6V. Logic 0
indicates normal operation; logic 1 indicates no signal detected.
7. Per Section 2.7.1. in the XFP MSA Specification1.
© Finisar Corporation 11-January-2011
Rev C1
Page 5
Finisar
FTLX3812M3xx Amplified DWDM XFP Product Specification – January 2011
IV.
Optical Characteristics (EOL, TOP = -5 to 70°C, VCC5 = 4.75 to 5.25 Volts)
Please note that the Transmitter of the FTLX3812M3xx becomes operational within 60
seconds of power-up. This is due to the time required for the EML to reach its optimum
operating temperature.
Transmitter
Parameter
Output Opt. Pwr: 9/125 SMF
Optical Extinction Ratio
Center Wavelength Spacing
Transmitter Center Wavelength –
End Of Life
Transmitter Center Wavelength –
Beginning Of Life
Sidemode Suppression ratio
Tx Jitter Generation (peak-to-peak)
Tx Jitter Generation (RMS)
Symbol
POUT
ER
Min
-3
8.2
λc
X-100
100
X
λc
X-25
X
SSRmin
Txj
TxjRMS
30
Relative Intensity Noise
Receiver
Maximum Input Power
Optical Center Wavelength
Receiver Reflectance
LOS De-Assert
LOS Assert
LOS Hysteresis
Receiver Sensitivity
Data rate
(Gb/s)
BER
9.95
1e-12
10.3
1e-12
10.7
1e-4
11.1
1e-4
OSNR Performance
Data rate
(Gb/s)
BER
Typ
RIN
PMAX
λC
Rrx
LOSD
LOSA
-7
1270
Max
+3
Ref.
X+100
Unit
dBm
dB
GHz
pm
X+25
pm
2
0.1
0.01
dB
UI
UI
3
4
-130
dB/Hz
1600
-27
-30
-37
0.5
1
2
dBm
nm
dB
dBm
dBm
dB
Dispersion (ps/nm)
Sensitivity back-toback at OSNR>30dB
(dBm)
Power Penalty
at OSNR>30dB
(dB)
5
Threshold
Adjustm.
Required
-500 to 1450
-500 to 1450
-500 to 1300
-500 to 1300
-23
-23
-27
-27
3
3
3
3
No
No
Yes
Yes
Dispersion (ps/nm)
Min OSNR Back-toback at Power: -7 to 18dBm (dB)
Max OSNR Penalty
at Power:-7 to -18dBm
(dB)
6
Threshold
Adjustm.
Required
9.95
1e-12
-500 to 1450
24
4
No
10.3
1e-12
-500 to 1450
24
4
No
10.7
1e-4
-500 to 1300
16
4
Yes
11.1
1e-4
-500 to 1300
16
4
Yes
Notes:
1. Corresponds to approximately 0.8 nm.
2. X = Specified ITU Grid wavelength. Wavelength stability is achieved within 60 seconds of power up.
3. Measured with a host jitter of 50 mUI peak-to-peak.
4. Measured with a host jitter of 7 mUI RMS.
5. Measured at 1528-1600nm with worst ER; BER<10-12; PRBS31.
6. All OSNR measurements are performed with 0.1nm resolution.
© Finisar Corporation 11-January-2011
Rev C1
Page 6
Finisar
FTLX3812M3xx Amplified DWDM XFP Product Specification – January 2011
V.
General Specifications
Parameter
Bit Rate
Max. Supported Link Length
Symbol
BR
LMAX
Min
9.95
Typ
Max
11.1
80
Units
Gb/s
km
Ref.
1
Notes:
1. Amplified SONET OC-192, 10G Ethernet, SONET OC-192 with FEC, 10G Ethernet with FEC
VI.
Environmental Specifications
Finisar XFP transceivers have an operating temperature range from -5°C to +70°C case
temperature.
Parameter
Case Operating Temperature
Storage Temperature
VII.
Symbol
Top
Tsto
Min
-5
-40
Typ
Max
70
85
Units
°C
°C
Ref.
Regulatory Compliance
Finisar XFP transceivers are Class 1 Laser Products. They are certified per the following
standards:
Feature
Agency
Standard
Laser Eye
Safety
Laser Eye
Safety
FDA/CDRH
CDRH 21 CFR 1040 and Laser Notice 50
TÜV
72101686
Electrical
Safety
Electrical
Safety
TÜV
EN 60825-1: 1994+A11:1996+A2:2001
IEC 60825-1: 1993+A1:1997+A2:2001
IEC 60825-2: 2000, Edition 2
EN 60950
CLASS 3862.07
CLASS 3862.87
2283290
UL/CSA
Certificate
Number
9210176-77
72101686
Copies of the referenced certificates are available at Finisar Corporation upon request.
© Finisar Corporation 11-January-2011
Rev C1
Page 7
FTLX3812M3xx Amplified DWDM XFP Product Specification – January 2011
Finisar
VIII. Digital Diagnostics Functions
As defined by the XFP MSA1, Finisar XFP transceivers provide digital diagnostic
functions via a 2-wire serial interface, which allows real-time access to the following
operating parameters:
•
•
•
•
•
•
Transceiver temperature
Laser bias current
Transmitted optical power
Received optical power
Transceiver supply voltage
TEC Temperature
It also provides a sophisticated system of alarm and warning flags, which may be used to
alert end-users when particular operating parameters are outside of a factory-set normal
range.
The operating and diagnostics information is monitored and reported by a Digital
Diagnostics Transceiver Controller (DDTC) inside the transceiver, which is accessed
through the 2-wire serial interface. When the serial protocol is activated, the serial clock
signal (SCL pin) is generated by the host. The positive edge clocks data into the XFP
transceiver into those segments of its memory map that are not write-protected. The
negative edge clocks data from the XFP transceiver. The serial data signal (SDA pin) is
bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to
mark the start and end of serial protocol activation. The memories are organized as a
series of 8-bit data words that can be addressed individually or sequentially. The 2-wire
serial interface provides sequential or random access to the 8 bit parameters, addressed
from 000h to the maximum address of the memory.
For more detailed information, including memory map definitions, please see the XFP
MSA documentation1.
Receiver Threshold Adjustment
The FTLX3812M3xx also provides access to receiver decision threshold adjustment via
2-wire serial interface, in order to improve receiver OSNR performance based on specific
link conditions. It is implemented as follows:
•
•
Rx Threshold of XFP transceivers will be factory-set for optimized performance
in non-FEC applications. This will be the default value during both cold start
(power-up) and warm start (module reset).
The transceiver supports adjustment of Rx Threshold value by the host through
register 76d, table 01h. This is intended to be used in FEC applications.
© Finisar Corporation 11-January-2011
Rev C1
Page 8
FTLX3812M3xx Amplified DWDM XFP Product Specification – January 2011
•
•
IX.
Finisar
Register 76d, table 01h is a volatile memory. Therefore if the transceiver is
power-cycled, the register starts up with a value of 00h which corresponds to the
default Rx Threshold value.
The threshold adjustment input value is 2’s complement 7 bit value (-128 to
+127), with 0 corresponding to default Rx threshold value. Full range of
adjustment provides at least a ±10% change in Rx threshold from the default
value.
Mechanical Specifications
Finisar’s XFP transceivers are compliant with the dimensions defined by the XFP MultiSourcing Agreement (MSA).
77.95
22.15
18.35
13.30
8.50
LATCHED
1.95
16.00
UNLATCHED
20.85
39.00
R1.00
XFP Transceiver (dimensions are in mm)
© Finisar Corporation 11-January-2011
Rev C1
Page 9
FTLX3812M3xx Amplified DWDM XFP Product Specification – January 2011
X.
Finisar
PCB Layout and Bezel Recommendations
XFP Host Board Mechanical Layout (dimensions are in mm)
© Finisar Corporation 11-January-2011
Rev C1
Page 10
FTLX3812M3xx Amplified DWDM XFP Product Specification – January 2011
Finisar
XFP Detail Host Board Mechanical Layout (dimensions are in mm)
XFP Recommended Bezel Design (dimensions are in mm)
© Finisar Corporation 11-January-2011
Rev C1
Page 11
FTLX3812M3xx Amplified DWDM XFP Product Specification – January 2011
Finisar
XI.
References
1.
10 Gigabit Small Form Factor Pluggable Module (XFP) Multi-Source Agreement
(MSA), Rev 4.5 – August 2005. Documentation is currently available at
http://www.xfpmsa.org/
2.
Application Note AN-2035: “Digital Diagnostic Monitoring Interface for XFP
Optical Transceivers” – Finisar Corporation, December 2003
3.
Directive 2002/95/EC of the European Council Parliament and of the Council,
“on the restriction of the use of certain hazardous substances in electrical and
electronic equipment”. January 27, 2003.
4.
“Application Note AN-2038: Finisar Implementation Of RoHS Compliant
Transceivers”, Finisar Corporation, January 21, 2005.
XII.
Revision History
Revision
Date
A
4/12/2006
•
Document created.
A1
4/21/2006
•
Updated Finisar Address
A2
5/22/2006
•
Updated BOL wavelength tolerance specification.
B
10/25/2006
•
Added Safety Certificate numbers.
•
Document released.
B1
9/28/2007
•
Updated note on channels.
C1
1/11/2011
•
Updated Regulatory Compliance Data
XII.
Description
For More Information
Finisar Corporation
1389 Moffett Park Drive
Sunnyvale, CA 94089-1133
Tel. 1-408-548-1000
Fax 1-408-541-6138
[email protected]
www.finisar.com
© Finisar Corporation 11-January-2011
Rev C1
Page 12