PANDUIT LCAX500-58-6 Flex conductor, one-hole, standard barrel with window lug Datasheet

ELECTRICAL SOLUTIONS
A.
System
Overview
B1.
Cable Ties
Flex Conductor, One-Hole, Standard Barrel with Window Lug
For Use with Flexible, Extra-Flexible, and Code Stranded Copper Conductors
Type LCAX
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
• Can be used with code conductor and flex conductor class: G, H, I,
K, M and Diesel Locomotive
• Generously beveled wire entry prevents bent back strands when
inserting conductor into barrel
• Color-coded barrels marked with Panduit and specified competitor
die index numbers for proper crimp die selection
C1.
Wiring
Duct
• Inspection window to visually assure full conductor insertion
• Tin-plated to inhibit corrosion
• UL Listed and CSA Certified to 35 KV** and temperature rated to
90°C when crimped with Panduit and specified competitor
crimping tools and dies
• American Bureau of Shipping approved
W
L
C2.
Surface
Raceway
B
INSPECTION
WINDOW
T
C3.
Abrasion
Protection
C4.
Cable
Management
Part Number
LCAX8-10-L
Flex Conductor Size
Code
Conductor
Class
Diesel
Size
G, H, I, K, M Locomotive
LCAX8-14-L
D2.
Power
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
W
B
T
L
0.41 0.42 0.08 1.11
Panduit
Color
Code
Red
Panduit
Die Index
No.‡
P21
Burndy
Die
Index
No.‡
49
T&B
Die
Index
No.‡
21
Wire Strip Std.
Length
Pkg.
(In.)
Qty.
1/2
50
1/4
0.48 0.42 0.07 1.20
Red
P21
49
21
1/2
50
0.56 0.42 0.05 1.32
Red
P21
49
21
1/2
50
LCAX8-38-L
3/8
0.60 0.42 0.05 1.42
Red
P21
49
21
1/2
50
LCAX6-10-L
#10
0.45 0.48 0.09 1.19
Blue
P24
7
24
9/16
50
LCAX6-14-L
1/4
0.48 0.48 0.08 1.28
Blue
P24
7
24
9/16
50
50
LCAX6-56-L
#8 AWG
#6 AWG
#8 AWG
#6 AWG
#8 AWG
#6 AWG
5/16
0.56 0.48 0.07 1.40
Blue
P24
7
24
9/16
LCAX6-38-L
3/8
0.62 0.48 0.06 1.50
Blue
P24
7
24
9/16
50
LCAX4-10-L
#10
0.55 0.53 0.09 1.26
Gray
P29
8
29
5/8
50
LCAX4-14-L
D3.
Grounding
Connectors
Figure Dimensions
(In.)
5/16
LCAX8-56-L
D1.
Terminals
Stud
Hole
Size
(In.)
#10
1/4
0.55 0.53 0.09 1.35
Gray
P29
8
29
5/8
50
5/16
0.55 0.53 0.09 1.47
Gray
P29
8
29
5/8
50
LCAX4-38-L
3/8
0.62 0.53 0.07 1.57
Gray
P29
8
29
5/8
50
LCAX2-10-E*
#10
0.70 0.59 0.11 1.40
Brown
P33
10
33
11/16
20
LCAX2-14-E*
1/4
0.70 0.59 0.11 1.50
Brown
P33
10
33
11/16
20
LCAX4-56-L
LCAX2-56-E*
#4 AWG
#5, #4, #3
AWG
#4 AWG
5/16
0.70 0.59 0.11 1.63
Brown
P33
10
33
11/16
20
3/8
0.70 0.59 0.11 1.70
Brown
P33
10
33
11/16
20
LCAX2-12-E*
1/2
0.75 0.59 0.09 1.94
Brown
P33
10
33
11/16
20
LCAX1-10-X
#10
0.76 0.66 0.12 1.50
Green
P37
11
37
3/4
10
LCAX1-14-X
1/4
0.76 0.66 0.12 1.67
Green
P37
11
37
3/4
10
#2 AWG
#2 AWG
#2 AWG
LCAX2-38-E*
LCAX1-56-X
5/16
0.76 0.66 0.12 1.72
Green
P37
11
37
3/4
10
LCAX1-38-X
3/8
0.76 0.66 0.12 1.80
Green
P37
11
37
3/4
10
LCAX1-12-X
1/2
0.80 0.66 0.12 2.03
Green
P37
11
37
3/4
10
#1 AWG
#1 AWG
#1 AWG
‡See pages D3.70 – D3.73 for tool and die information.
*Not UL Listed or CSA Certified with Class K flex conductor when crimped with Burndy tools.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
Order number of pieces required, in multiples of Standard Package Quantity.
Prime items appear in BOLD.
ELECTRICAL SOLUTIONS
A.
System
Overview
Flex Conductor, One-Hole, Standard Barrel with Window Lug (continued)
B1.
Cable Ties
W
B
T
L
0.85 0.72 0.13 1.82
Panduit
Die Index
No.‡
P42
Burndy
Die
Index
No.‡
12
T&B
Die
Index
No.‡
42
5/16
0.85 0.72 0.13 1.82
Pink
P42
12
42
3/4
10
3/8
0.85 0.72 0.13 1.89
Pink
P42
12
42
3/4
10
1/2
0.85 0.72 0.13 2.14
Pink
P42
12
42
3/4
10
LCAX1/0-58-X
5/8
0.96 0.72 0.11 2.38
Pink
P42
12
42
3/4
10
LCAX2/0-10-X
#10
0.96 0.83 0.13 1.72
Black
P45
13
45
7/8
10
LCAX2/0-14-X
1/4
0.96 0.83 0.13 1.97
Black
P45
13
45
7/8
10
LCAX2/0-56-X
5/16
0.96 0.83 0.13 1.97
Black
P45
13
45
7/8
10
Part Number
LCAX1/0-14-X
LCAX1/0-56-X
LCAX1/0-38-X
1/0 AWG
1/0 AWG
1/0 AWG
LCAX1/0-12-X
LCAX2/0-38-X
2/0 AWG
2/0 AWG
2/0 AWG
Stud
Hole
Size
(In.)
1/4
Figure Dimensions
(In.)
Panduit
Color
Code
Pink
Flex Conductor Size
Code
Conductor
Class
Diesel
Size
G, H, I, K, M Locomotive
Wire Strip Std.
Length
Pkg.
(In.)
Qty.
3/4
10
3/8
0.96 0.83 0.13 2.03
Black
P45
13
45
7/8
10
LCAX2/0-12-X
1/2
0.96 0.83 0.13 2.28
Black
P45
13
45
7/8
10
LCAX2/0-58-X
5/8
0.96 0.83 0.13 2.52
Black
P45
13
45
7/8
10
LCAX3/0-10-X
#10
1.06 0.91 0.14 1.84
Orange
P50
14
50
1
10
LCAX3/0-14-X
1/4
1.06 0.91 0.14 2.08
Orange
P50
14
50
1
10
LCAX3/0-56-X
5/16
1.06 0.91 0.14 2.10
Orange
P50
14
50
1
10
3/8
1.06 0.91 0.14 2.17
Orange
P50
14
50
1
10
LCAX3/0-12-X
1/2
1.06 0.91 0.14 2.40
Orange
P50
14
50
1
10
LCAX3/0-58-X
5/8
1.06 0.91 0.14 2.64
Orange
P50
14
50
1
10
LCAX4/0-14-X
1/4
1.19 1.03 0.16 2.30
Purple
P54
15
54
1 1/16
10
LCAX4/0-56-X
5/16
1.19 1.03 0.16 2.53
Purple
P54
15
54
1 1/16
10
3/8
1.19 1.03 0.16 2.53
Purple
P54
15
54
1 1/16
10
1/2
1.19 1.03 0.16 2.64
Purple
P54
15
54
1 1/16
10
LCAX4/0-58-X
5/8
1.19 1.03 0.16 2.85
Purple
P54
15
54
1 1/16
10
LCAX4/0-34-X
3/4
1.19 1.03 0.16 3.04
Purple
P54
15
54
1 1/16
10
10
LCAX3/0-38-X
3/0 AWG
3/0 AWG
3/0 AWG
LCAX4/0-38-X
LCAX4/0-12-X
4/0 AWG
4/0 AWG
4/0 AWG
LCAX250-14-X
1/4
1.28 1.03 0.17 2.34
Yellow
P62
16
62
1 1/16
LCAX250-56-X
5/16
1.28 1.03 0.17 2.57
Yellow
P62
16
62
1 1/16
10
LCAX250-38-X
3/8
1.28 1.03 0.17 2.57
Yellow
P62
16
62
1 1/16
10
1/2
1.28 1.03 0.17 2.68
Yellow
P62
16
62
1 1/16
10
LCAX250-12-X
250 kcmil
262.6 kcmil
—
LCAX250-58-X
5/8
1.28 1.03 0.17 2.89
Yellow
P62
16
62
1 1/16
10
LCAX250-34-X
3/4
1.28 1.03 0.17 3.08
Yellow
P62
16
62
1 1/16
10
LCAX300-38-6
3/8
1.39 1.19 0.18 2.91
Red
P71
18
71H
1 1/4
6
LCAX300-12-6
1/2
1.39 1.19 0.18 2.91
Red
P71
18
71H
1 1/4
6
LCAX300-58-6
5/8
1.39 1.19 0.18 3.12
Red
P71
18
71H
1 1/4
6
LCAX350-56-6
5/16
1.54 1.29 0.22 2.93
Blue
P76
19
76H
1 3/8
6
LCAX350-38-6
3/8
1.54 1.29 0.22 2.93
Blue
P76
19
76H
1 3/8
6
LCAX350-12-6
300 kcmil
350 kcmil
313.1 kcmil
373.7 kcmil
—
—
1/2
1.54 1.29 0.22 3.09
Blue
P76
19
76H
1 3/8
6
LCAX350-58-6
5/8
1.54 1.29 0.22 3.30
Blue
P76
19
76H
1 3/8
6
LCAX450-12-6
1/2
1.70 1.40 0.26 3.60
Brown
P87
20
87H
1 7/16
6
5/8
1.70 1.40 0.26 3.73
Brown
P87
20
87H
1 7/16
6
LCAX450-58-6
450 kcmil
444.4 kcmil
—
LCAX500-56-6
5/16
1.89 1.48 0.26 3.27
Pink
P99
L99
99H
1 9/16
6
LCAX500-38-6
3/8
1.89 1.48 0.26 3.27
Pink
P99
L99
99H
1 9/16
6
LCAX500-12-6
500 kcmil
535.3 kcmil
—
1/2
1.89 1.48 0.26 3.64
Pink
P99
L99
99H
1 9/16
6
LCAX500-58-6
5/8
1.89 1.48 0.26 4.20
Pink
P99
L99
99H
1 9/16
6
LCAX650-56-6
5/16
1.95 1.45 0.30 3.27
Black
P106
24
106H
1 1/2
6
LCAX650-38-6
3/8
1.95 1.45 0.30 3.27
Black
P106
24
106H
1 1/2
6
1/2
1.95 1.45 0.30 3.64
Black
P106
24
106H
1 1/2
6
5/8
1.95 1.45 0.30 4.20
Black
P106
24
106H
1 1/2
6
LCAX650-12-6
—
646.4 kcmil
—
LCAX650-58-6
LCAX750-12-3
LCAX750-58-3
—
777.7 kcmil
—
1/2
2.17 1.66 0.32 3.94
Yellow
P115
L115
115H
1 3/4
3
5/8
2.17 1.66 0.32 4.59
Yellow
P115
L115
115H
1 3/4
3
‡See pages D3.70 – D3.73 for tool and die information.
*Not UL Listed or CSA Certified with Class K flex conductor when crimped with Burndy tools.
**Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V.
B2.
Cable
Accessories
B3.
Stainless
Steel Ties
C1.
Wiring
Duct
C2.
Surface
Raceway
C3.
Abrasion
Protection
C4.
Cable
Management
D1.
Terminals
D2.
Power
Connectors
D3.
Grounding
Connectors
E1.
Labeling
Systems
E2.
Labels
E3.
Pre-Printed
& Write-On
Markers
E4.
Permanent
Identification
E5.
Lockout/
Tagout
& Safety
Solutions
F.
Index
For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory)
Similar pages