BTE4000 / PTU4000 Series Pressure transmitters FEATURES · 0...-1 to 0...10 bar absolute or gage1, 0...-15 to 0...150 psi gage1 · 0...5 V, 0...10 V, 1...6 V, 4...20 mA output · Field interchangeable · Rugged aluminium housing MEDIA COMPATIBILITY Wetted materials: aluminium, silicon, glass Housing: Aluminium, protection class IP 65 (according to DIN EN 60529) respectively NEMA 41 SPECIFICATIONS9,10 ELECTRICAL CONNECTION Maximum ratings 0...5 V, 0...10 V, 1...6 V output Supply voltage (reverse polarity protection)2 BTE(M)/PTU4...0, ...1, ...7 BTE(M)/PTU4...4 Maximum load current BTE(M)/PTU4...0, ...1, ...7 sensor -55 to 100°C -40 to 100°C 0 to 50°C Humidity limits 0 - 100 %RH Mechanical shock BTEM4.../PTU4x01..., 05... 50 g BTE4010.../PTU4150... all others December 2008 / 096 sensor 1.4 bar / 20 psi 16 bar / 200 psi 2 x rated pressure V GND 4...20 mA output 2g Proof pressure3 13 ... 30 V 1 Vout 3 -Vs 2 10 mA Temperature limits Storage Operating Compensated Vibration (5 to 500 Hz) +Vs 13...30 V 12...36 V +Vs 1 N/C 3 -Vs 2 12 ... 36 V V RL GND 1/6 www.sensortechnics.com BTE4000 / PTU4000 Series Pressure transmitters COMMON PERFORMANCE CHARACTERISTICS (VS = 15 V, tamb = 25°C) Characteristics Operating pressure Thermal effects (0 to 50°C)5 (-20 to 0°C, 50 to 70°C)5 Non-linearity and hysteresis (BSL)6 Repeatability Long term stability7 Output noise (0 - 1 kHz) Response time (10 to 90 %) Power supply rejection December 2008 / 096 Min. BTEM40070.. BTEM4P070.. BTEM4N250.. BTEM40350.. BTEM4N350.. BTEM4P350.. BTE4001.. BTE4N01.. BTE4P01.. BTE4002.. BTE4005.. BTE4010.. PTU4001.. PTU4P01.. PTU4005.. PTU4P05.. PTU4015.. PTU4P015.. PTU4030.. PTU4100.. PTU4150 Offset Span Offset Span Offset Span Typ. 0 -70 -25 0 -350 -350 0 -1 -1 0 0 0 0 -1 0 -5 0 -15 0 0 0 Max. 70 70 0 350 0 350 1 0 1 2 5 10 1 1 5 5 15 15 30 100 150 0.04 0.04 0.02 0.02 ±0.2 ±0.10 ±0.5 ±0.04 1.0 0.05 0.03 Unit mbar bar p si g %FSO/°C ±0.50 %FS ms %/V 2/6 www.sensortechnics.com BTE4000 / PTU4000 Series Pressure transmitters INDIVIDUAL PERFORMANCE CHARACTERISTICS1 0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Min. Typ. Max. Unit 4.85 -0.15 4.9 9.9 5.0 0 5.0 10.0 5.15 0.15 5.1 10.1 V Output impedance 6.0 50 Ω Power consumption (no load) 100 Zero pressure offset Full scale span4 BTE/PTU4N... all others BTE/PTU4N... all others mW 0...5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Min. Typ. Max. Unit 2.35 -0.15 2.4 4.9 2.5 0 2.5 5.0 2.65 0.15 2.6 5.1 V Output impedance 6.0 50 Ω Power consumption (no load) 100 Zero pressure offset Full scale span4 BTE/PTU4N... all others BTE/PTU4N... all others mW 1...6 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Min. Typ. Max. Unit 3.35 0.85 2.4 4.9 3.5 1.0 2.5 5.0 3.65 1.15 2.6 5.1 V Output impedance 6.0 50 Ω Power consumption (no load) 100 Zero pressure offset Full scale span4 BTE/PTU4N... all others BTE/PTU4N... all others mW 4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C) Characteristics Zero pressure offset Full scale span4 BTE/PTU4N... all others BTE/PTU4N... all others Min. Typ. Max. Unit 11.8 3.8 7.9 15.8 12.0 4.0 8.0 16.0 12.2 4.2 8.1 16.2 mA Output impedance 0.1 Ω Power consumption (IL = 20 mA) 260 mW December 2008 / 096 3/6 www.sensortechnics.com BTE4000 / PTU4000 Series Pressure transmitters OUTPUT CHARACTERISTICS 0...5 V output version 0...10 V output version 10 10 Vout V 9 Vout 9 V 8 8 7 BTE/PTU4P... 7 6 6 BTE/PTU4P... 5 BTE/PTU4N... 4 5 4 3 all others BTE/PTU4N... 3 all others 2 1 2 1 -100 -80 -60 -40 -20 0 +20 +40 +60 +80 +100 % operating pressure 1...6 V output version -100 -80 -60 -40 -20 0 +20 +40 +60 +80 +100 % operating pressure 4...20 mA output version 10 20 Vout 9 V 8 Iout 18 mA 16 7 14 6 BTE/PTU4P... 12 BTE/PTU4P... 5 10 BTE/PTU4N... BTE/PTU4N... 4 8 3 all others 6 all others 2 4 1 2 -100 -80 -60 -40 -20 0 +20 +40 +60 +80 +100 % operating pressure -100 -80 -60 -40 -20 0 +20 +40 +60 +80 +100 % operating pressure LOAD LIMITATION 1200 Ohm 1000 800 600 operating range 400 200 0 10 December 2008 / 096 20 30 V Vsupply 4/6 www.sensortechnics.com BTE4000 / PTU4000 Series Pressure transmitters ELECTROMAGNETIC CAPABILITY8 Radiated, radio frequency electromagnetic field immunity (RFI) Electrical fast transient / burst immunity (EFT) Electrostatic discharge immunity test (ESD) Immunity to conducted disturbances induced by radio-frequency fields Test conditions Criterion Interference EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz A <1 %FSO 80 % AMC (1 kHz) EN61000-4-4: Grade 3, ±2 kV B <1 %FSO EN61000-4-2: Grade 4, ±8 kV, contact discharge EN61000-4-6: Grade 3, 0.15 to 80 MHz 10 V, 80 % AMC (1 kHz) B <1 %FSO A <1 %FSO OUTLINE DRAWING 93.0 (3.66) 12.0 (0.47) 70.0 (2.76) 10.0 (0.39) 18.0 (0.71) 18.0 (0.71) 14.0 (0.55) 30.0 (1.18) 2.0 (0.08) 1 2 vent hole 3/8" BSP (1/4"-18 NPT for PTU devices) 3 12.0 (0.47) mass: typ. 145 g dimensions in mm (inches) PIN Voltage version Current version 1 +Vs +Vs 2 -Vs -Vs 3 Vout N/C ca se ca se RECOMMENDED ACCESSORY Plug DIN EN 175301-803 A and profile washer included in delivery. For a complete connector/cable assembly use order no. ZK000110-x (x=cable lenghts in m). 50 34 Profile washer M3 31 dimensions in mm Note: For proper function of all gage devices the gage port must be vented to the atmosphere through the connector/cable assembly. December 2008 / 096 5/6 www.sensortechnics.com BTE4000 / PTU4000 Series Pressure transmitters Specification notes: 1. IP 65 protection is given with locked connector only. The package is an all-sealed housing. For proper function, the gage port is vented to the atmosphere through the connecting cable. Thus, the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Full scale span is the algebraic difference between the positive full scale output and offset. 5. Thermal effects tested and guaranteed from 0 to 50°C relative to 25°C. All specifications shown are relative to 25°C. 6. Linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full scale pressure. 7. Long term stability is the change in output after one year or 1 million pressure cycles. 8. Test are in accordance with EN61000-6-2, April 1999. 9. CE-labelling is in accordance with 89/336/EEC. 10. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. ORDERING INFORMATION xTx(x)4 BTE(M): PTU: (x)xxx (m)bar calibration psi calibration BTE(M)4000 series 001: 0 to 1 bar N01: 0 to -1 bar P01: -1 to +1 bar 002: 0 to 2 bar 005: 0 to 5 bar 010: 0 to 10 bar 0070: 0 to 70 mbar P070: -70 to +70 mbar N250: 0 to -250 mbar 0350: 0 to 350 mbar N350: 0 to -350 mbar P350: -350 to +350 mbar Note: PTU4000 series 001: 0 to 1 psi P01: -1 to +1 psi 005: 0 to 5 psi P05: -5 to +5 psi 015: 0 to 15 psi P15: -15 to +15 psi 030: 0 to 30 psi 100: 0 to 100 psi 150: 0 to 150 psi x x Output signal 0: 0...10 V 1: 1...6 V 4: 4...20 mA 7: 0...5 V Pressure mode G: gage pressure1 A: absolute pressure (available for pressure ranges from 1 bar/15 psi upwards only) Other pressure ranges and options are widely available. Please contact your nearest Sensortechnics sales representative. Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. December 2008 / 096 6/6 www.sensortechnics.com