Technical Specification IQ36-HP Family 16-40V 1.8-48V 200W 2250Vdc Half-brick Continuous Input Outputs Max Power Isolation DC-DC Converter The InQor® Half-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. Each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications. Operational Features • • • • • High efficiencies, up to 83% at full rated load current Delivers full power with minimal derating - no heatsink required Operating input voltage range: 16-40 V Fixed frequency switching provides predictable EMI No minimum load requirement Protection Features Mechanical Features • Industry standard Half-brick pin-out configuration • Size: 2.386" x 2.486" x 0.512" (60.6 x 63.14 x 13.0 mm) • Total weight: 5 oz (142 g) Control Features • • • • • • • On/Off control referenced to input side • Remote sense for the output voltage • Output voltage trim range of -20%, +10% CONTENTS Page No. Safety Features • 2250 V, 30 MW input-to-output isolation • UL/cUL 60950-1 recognized (US & Canada), basic insulation rating • TUV certified to EN60950-1 • Meets directives which facilitates CE Marking in user’s end product • Board and plastic components meet UL94V-0 standard • RoHS compliant (see page 30) Product # IQ36xxxHPXxx Phone 1-888-567-9596 Input under-voltage lockout Input over-voltage shutdown Output current limit and short circuit protection Active back bias limit Output over-voltage protection Thermal shutdown Mechanical Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 IQ36-HP Family Electrical Characteristics 4���������������������������������������� 3 - 4 IQ36-HP Family Figures 1���������������������������������������������������������������������� 5 IQ36018HPx60 (1.8 V, 60 A) Characteristics and Figures ������������������ 6 - 7 IQ36033HPx50 (3.3 V, 50 A) Characteristics and Figures ������������������ 8 - 9 IQ36050HPx36 (5.0 V, 36 A) Characteristics and Figures0��������������� 10 - 11 IQ36070HPx30 (7.0 V, 30 A) Characteristics and Figures2��������������� 12 - 13 IQ36120HPx18 (12 V, 15 A) Characteristics and Figures 2��������������� 12 - 13 IQ36150HPx14 (15 V, 14 A) Characteristics and Figures 4��������������� 14 - 15 IQ36240HPx09 (24 V, 9.0 A) Characteristics and Figures6��������������� 16 - 17 IQ36280HPx7F (28 V, 7.5 A) Characteristics and Figures8��������������� 18 - 19 IQ36400HPx5F (40 V, 5.5 A) Characteristics and Figures0��������������� 20 - 21 IQ36480HPx4F (48 V, 4.5 A) Characteristics and Figures2��������������� 22 - 23 Application Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 - 27 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 1 Technical Specification IQ36-HP Family IQ36-HP Mechanical Drawing ±.020 [ 63,14 2.486 2.00 1.400 1.000 ±0,5 ] [ 50,8 ] [ 35,56 ] [ 25,4 ] .700 [ 17,78 ] .400 [ 10,16 ] 8 7 6 5 +.002 -.005 +0,05 13 -0,12 OVERALL HEIGHT .512 .243 ±.020 [ 6,17 ±0,5 ] [ ] .163 [ 4,14 ] 4 .243 ±.020 [ 6,17 ±0,5 ] 2.386 ±.020 [ 60,6 ±0,5 ] TOP VIEW 1.90 [ 48,3 ] SIDE VIEW 1.90 [ 48,3 ] .233 ±.020 [ 5,92 ±0,5 ] 1 2 3 .543 ±.020 [ 13,79 ±0,5 ] .400 [ 10,16 ] 1.400 THRU HOLE M3 (SEE NOTE 8) STANDOFFS (4) 4) 5) 6) 7) 8) 9) [ ] BOTTOMSIDE CLEARANCE [ 35,56 ] PIN DESIGNATIONS NOTES 1) 2) 3) +.007 -.010 +0,17 0,69 -0,25 .027 Applied torque per screw should not exceed 6in-lb. (0.7 Nm). Baseplate flatness tolerance is 0.004" (.10 mm) TIR for surface. Pins 1-3, 5-7 are 0.040” (1.02mm) diameter, with 0.080” (2.03mm) diameter standoff shoulders. Pins 4 and 8 are 0.080” (2.03 mm) dia. with 0.125” (3.18 mm) dia. standoff shoulders All Pins: Material: Copper Alloy Finish: Matte Tin over Nickel plate Undimensioned Components are shown for visual reference only Weight: 4.9oz (142g) Threaded or Non-Threaded options available All dimensions in inches (mm) Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm) Pin Name Function 1 Vin(+) Positive input voltage 2 ON/OFF 3 Vin(–) 4 Vout(–) 5 SENSE(–) 6 TRIM 7 SENSE(+) Positive remote sense3 8 Vout(+) Positive output voltage TTL input to turn converter on and off, referenced to Vin(–), with internal pull up. Negative input voltage Negative output voltage Negative remote sense1 Output voltage trim2 Notes: 1) 2) 3) Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com SENSE(–) should be connected to Vout(–) either remotely or at the converter. Leave TRIM pin open for nominal output voltage. SENSE(+) should be connected to Vout(+) either remotely or at the converter. Doc.# 005-0005231 Rev. A 05/26/09 Page 2 Technical Specification IQ36-HP Family IQ36 FAMILY ELECTRICAL CHARACTERISTICS (all output voltages) Ta = 25 °C, airflow rate = 300 LFM, Vin = 36 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. ABSOLUTE MAXIMUM RATINGS Input Voltage Non-Operating 60 Operating 40 Operating Transient Protection 50 Isolation Voltage Input to Output 2250 Input to Base-Plate 2250 Output to Base-Plate 2250 Operating Temperature -40 100 Storage Temperature -55 125 Voltage at ON/OFF input pin -2 18 INPUT CHARACTERISTICS Operating Input Voltage Range 16 28 40 Input Under-Voltage Lockout Turn-On Voltage Threshold 16.6 17.0 17.4 Turn-Off Voltage Threshold 13.8 14.1 14.4 Lockout Voltage Hysteresis 2.9 Input Over-Voltage Shutdown 77 80 Recommended External Input Capacitance 470 Input Filter Component Values (L\C) 1.1\13.2 DYNAMIC CHARACTERISTICS Turn-On Transient Turn-On Time 10 Start-Up Inhibit Time 200 230 250 Output Voltage Overshoot 0 ISOLATION CHARACTERISTICS Isolation Voltage (dielectric strength) Isolation Resistance 30 Isolation Capacitance (input to output) 1000 TEMPERATURE LIMITS FOR POWER DERATING CURVES Semiconductor Junction Temperature 125 Board Temperature 125 Transformer Temperature 125 Maximum Baseplate Temperature, Tb 100 FEATURE CHARACTERISTICS Switching Frequency 255 275 295 ON/OFF Control Off-State Voltage 2.4 1.8 On-State Voltage -2 0.8 ON/OFF Control Pull-Up Voltage 5 Pull-Up Resistance 50 Over-Temperature Shutdown OTP Trip Point 125 Over-Temperature Shutdown Restart Hysteresis 10 RELIABILITY CHARACTERISTICS Calculated MTBF (Telcordia) TR-NWT-000332 TBD Calculated MTBF (MIL-217) MIL-HDBK-217F TBD Field Demonstrated MTBF Note 1: Start-up guaranteed above 10.4 V, but will operate down to 9V Note 2: Higher values of isolation capacitance can be added external to the module. Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Units Notes & Conditions V V V V dc V dc V dc °C °C V V Continuous Continuous 1 s transient, square wave Baseplate temperature 50V transient for 1 s; see Note 1 V V V V µF µH\µF Typical ESR 0.1-0.2 Ω Internal values; see Figure E ms ms % Full load, Vout=90% nom. -40 °C to +125 °C; Figure F Maximum Output Capacitance See Absolute Maximum Ratings MΩ pF See Note 2 °C °C °C °C Package rated to 150 °C UL rated max operating temp 130 °C kHz Isolation stage switching freq. is half this V Application notes Figures A & B V kΩ °C °C Average PCB Temperature 106 Hrs. 80% load, 200LFM, 40 °C Ta 106 Hrs. 80% load, 200LFM, 40 °C Ta 106 Hrs. See our website for details Doc.# 005-0005231 Rev. A 05/26/09 Page 3 Technical Specification IQ36-HP Family IQ36-HP Standards Compliance & Qualification Testing STANDARDS COMPLIANCE Parameter Notes & Conditions STANDARDS COMPLIANCE UL/cUL 60950-1 EN60950-1 Needle Flame Test (IEC 695-2-2) IEC 61000-4-2 File # E194341, Basic insulation Certified by TUV Test on entire assembly; board & plastic components UL94V-0 compliant ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance) Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website. QUALIFICATION TESTING Parameter QUALIFICATION TESTING Life Test Vibration Mechanical Shock Temperature Cycling Power/Thermal Cycling Design Marginality Humidity Solderability Product # IQ36xxxHPXxx # Units 32 5 5 10 5 5 5 15 pins Phone 1-888-567-9596 Test Conditions 95% rated Vin and load, units at derating point, 1000 hours 10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis 100g minimum, 2 drops in x and y axis, 1 drop in z axis -40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles Toperating = min to max, Vin = min to max, full load, 100 cycles Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load 85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day MIL-STD-883, method 2003 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 4 Technical Specification IQ36-HP Family IQ36 FAMILY FIGURES (all output voltages) 120 Typical Current Limit Inception Point Nominal Vout Output Voltage (%) 100 80 Typical Output Voltage at Shutdown 60 40 Vin min Vin nom 20 Vin max 0 5.00 0 Common Figure 1: Typical startup waveform. Input voltage pre-applied, ON/OFF Pin on Ch 2. 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Load Current (% ) Common Figure 2: Output voltage vs. load current showing typical current limit curves and converter shutdown points. 100,000.0 100,000.0 1.8 V 10,000.0 3.3 V 5V 12 V 15 V Trim Resistance (kOhms) Trim Resistance (kOhms) 10 1,000.0 100.0 10.0 24 V 28 V 40 V 48 V 10,000.0 1,000.0 100.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Increase in Vout (%) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Increase in Vout (%) Common Figure 4: Trim graph for trim-up 15 to 48 V outputs. Common Figure 3: Trim graph for trim-up 1.8 to 12 V outputs. 10,000.0 Trim Resistance (kOhms) All voltages 1,000.0 100.0 10.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Decrease in Vout (%) Common Figure 5: Trim graph for trim down. Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 5 Input: Output: Current: Part No.: Technical Specification 18-75 V 1.8 V 60 A IQ36018HPx60 IQ36018HPx60 ELECTRICAL CHARACTERISTICS (1.8 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 36 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUTPUT CHARACTERISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection EFFICIENCY 100% Load 50% Load Typ. TBD 1.8 1.818 V ±0.1 ±0.1 ±0.3 ±0.3 27 1.845 % % mV V 180 80 60 78.0 15,000 mV mV A A V A mA µF 10 10 2.3 mV µs % % V 50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5; see Note 2 Across Pins 8&4 Over full temp range % % See Figure 1 for efficiency curve See Figure 1 for efficiency curve -27 1.755 0 0 66.0 90 40 72.0 0.9 1.1 0.093 10.7 100 4 75 500 -20 2.1 Units Notes & Conditions A mA mA V mA A 80 1.8 0.15 170 1.782 Max. 2.2 83 87 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Full load Full load Subject to thermal derating Output voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at low line and full load. Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 6 Input: Output: Current: Part No.: Technical Specification 28 100 26 95 24 22 Power Dissipation (W) 90 85 Efficiency (%) 18-75 V 1.8 V 60 A IQ36018HPx60 80 75 70 18 16 14 12 10 8 6 18 Vin 36 Vin 75 Vin 65 20 60 4 18 Vin 36 Vin 2 75 Vin 0 0 5 10 15 20 25 30 35 40 45 50 55 60 0 5 10 15 20 Load Current (A) 25 30 35 40 45 50 55 60 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 70 60 60 50 50 40 Iout (A) Iout (A) 40 30 30 20 400 LFM (2.0 m/s) 20 300 LFM (1.5 m/s) 300 LFM (1.5 m/s) 10 200 LFM (1.0 m/s) 10 400 LFM (2.0 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 0 25 40 55 70 85 Ambient Air Temperature (°C) 0 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (100 mV/div), Ch 2: Iout (20 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (200 mV/div), Ch 2: Vin (20 V/div). Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 7 Input: Output: Current: Part No.: Technical Specification 18-75 V 3.3 V 50 A IQ36033HPx50 IQ36033HPx50 ELECTRICAL CHARACTERISTICS (3.3 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 36 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUTPUT CHARACTERISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection EFFICIENCY 100% Load 50% Load Typ. TBD 3.3 3.333 V ±0.1 ±0.1 ±0.3 ±0.3 50 3.383 % % mV V 180 80 60 78.0 15,000 mV mV A A V A mA µF 10 10 4.2 mV µs % % V 50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5; see Note 2 Across Pins 8&4 Over full temp range % % See Figure 1 for efficiency curve See Figure 1 for efficiency curve -50 3.218 0 0 66.0 90 40 72.0 0.9 1.1 0.093 19.7 100 4 75 500 -20 3.9 Units Notes & Conditions A mA mA V mA A 80 1.8 0.15 170 3.267 Max. 4.0 83 87 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Full load Full load Subject to thermal derating Output voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at low line and full load. Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 8 Input: Output: Current: Part No.: Technical Specification 28 100 26 95 24 22 Power Dissipation (W) 90 85 Efficiency (%) 18-75 V 3.3 V 50 A IQ36033HPx50 80 75 70 18 16 14 12 10 8 6 18 Vin 36 Vin 75 Vin 65 20 60 4 18 Vin 36 Vin 2 75 Vin 0 0 5 10 15 20 25 30 35 40 45 50 0 5 10 15 Load Current (A) 20 25 30 35 40 45 50 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 50 50 40 40 Iout (A) 60 Iout (A) 60 30 30 20 20 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 10 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 10 200 LFM (1.0 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 0 25 40 55 70 85 Ambient Air Temperature (°C) 0 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (100 mV/div), Ch 2: Iout (20 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (500 mV/div), Ch 2: Vin (20 V/div). Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 9 Input: Output: Current: Part No.: Technical Specification 18-75 V 5.0V 36 A IQ36050HPx36 IQ36050HPx36 ELECTRICAL CHARACTERISTICS (5.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 36 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUTPUT CHARACTERISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection EFFICIENCY 100% Load 50% Load Typ. TBD 5 5.05 V ±0.1 ±0.1 ±0.3 ±0.3 75 5.125 % % mV V 180 80 60 78.0 15,000 mV mV A A V A mA µF 10 10 6.4 mV µs % % V 50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5; see Note 2 Across Pins 8&4 Over full temp range % % See Figure 1 for efficiency curve See Figure 1 for efficiency curve -75 4.875 0 0 66.0 90 40 72.0 0.9 1.1 0.093 29.8 100 4 75 500 -20 5.9 Units Notes & Conditions A mA mA V mA A 80 1.8 0.15 170 4.95 Max. 6.1 83 87 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Full load Full load Subject to thermal derating Output voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at low line and full load. Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 10 Input: Output: Current: Part No.: Technical Specification 100 95 Power Dissipation (W) 90 Efficiency (%) 85 80 75 70 18 Vin 36 Vin 75 Vin 65 60 0 4 8 12 16 20 24 28 32 36 18-75 V 5.0V 36 A IQ36050HPx36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 40 18 Vin 36 Vin 75 Vin 0 Load Current (A) 4 8 12 16 20 24 28 32 36 40 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 45 40 40 35 35 30 30 Iout (A) Iout (A) 25 25 20 20 15 15 400 LFM (2.0 m/s) 10 200 LFM (1.0 m/s) 5 400 LFM (2.0 m/s) 10 300 LFM (1.5 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 5 100 LFM (0.5 m/s) 0 100 LFM (0.5 m/s) 0 0 25 40 55 70 85 Ambient Air Temperature (°C) 0 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (200 mV/div), Ch 2: Iout (10 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (500 mV/div), Ch 2: Vin (20 V/div). Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 11 Input: Output: Current: Part No.: Technical Specification 18-75 V 7.0 V 30 A IQ36070HPx30 IQ36070HPx ELECTRICAL CHARACTERISTICS (7.0 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 36 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUTPUT CHARACTERISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection EFFICIENCY 100% Load 50% Load Typ. TBD 7 7.07 V ±0.1 ±0.1 ±0.3 ±0.3 105 7.175 % % mV V 180 80 60 78.0 15,000 mV mV A A V A mA µF 10 10 8.9 mV µs % % V 50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5; see Note 2 Across Pins 8&4 Over full temp range % % See Figure 1 for efficiency curve See Figure 1 for efficiency curve -105 6.825 0 0 66.0 90 40 72.0 0.9 1.1 0.093 41.7 100 4 75 500 -20 8.2 Units Notes & Conditions A mA mA V mA A 80 1.8 0.15 170 6.93 Max. 8.5 83 87 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Full load Full load Subject to thermal derating Output voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at low line and full load. Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 12 Input: Output: Current: Part No.: Technical Specification 30 100 95 25 Power Dissipation (W) 90 85 Efficiency (%) 18-75 V 7.0 V 30 A IQ36070HPx30 80 75 70 18 Vin 36 Vin 75 Vin 65 20 15 10 18 Vin 36 Vin 5 75 Vin 60 0 0 5 10 15 20 25 30 0 5 10 Load Current (A) 15 20 25 30 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 30 30 25 25 20 20 Iout (A) 35 Iout (A) 35 15 15 400 LFM (2.0 m/s) 10 400 LFM (2.0 m/s) 10 300 LFM (1.5 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 5 200 LFM (1.0 m/s) 5 100 LFM (0.5 m/s) 0 100 LFM (0.5 m/s) 0 25 40 55 70 85 Ambient Air Temperature (°C) 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (200 mV/div), Ch 2: Iout (10 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (200 mV/div), Ch 2: Vin (50 V/div). Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 13 Input: Output: Current: Part No.: Technical Specification 18-75 V 12 V 15 A IQ36120HPx15 IQ36120HPx15 ELECTRICAL CHARACTERISTICS (12 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 36 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUTPUT CHARACTERISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection EFFICIENCY 100% Load 50% Load Typ. TBD 12 12.12 V ±0.1 ±0.1 ±0.3 ±0.3 180 12.300 % % mV V 180 80 60 78.0 15,000 mV mV A A V A mA µF 10 10 15.2 mV µs % % V 50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5; see Note 2 Across Pins 8&4 Over full temp range % % See Figure 1 for efficiency curve See Figure 1 for efficiency curve -180 11.700 0 0 66.0 90 40 72.0 0.9 1.1 0.093 71.6 100 4 75 500 -20 14.0 Units Notes & Conditions A mA mA V mA A 80 1.8 0.15 170 11.88 Max. 14.6 83 87 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Full load Full load Subject to thermal derating Output voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at low line and full load. Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 14 Input: Output: Current: Part No.: Technical Specification 100 26 24 95 22 20 Power Dissipation (W) 90 Efficiency (%) 85 80 75 70 18 Vin 36 Vin 75 Vin 65 60 18 16 14 12 10 8 6 4 18 Vin 36 Vin 2 75 Vin 0 0 2 4 6 8 10 12 14 16 18 0 2 4 6 Load Current (A) 8 10 12 14 16 18 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 20 18 18 16 16 14 14 12 12 Iout (A) 20 Iout (A) 18-75 V 12 V 18 A IQ36120HPx18 10 10 8 6 300 LFM (1.5 m/s) 4 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 4 200 LFM (1.0 m/s) 2 8 6 400 LFM (2.0 m/s) 200 LFM (1.0 m/s) 2 100 LFM (0.5 m/s) 0 100 LFM (0.5 m/s) 0 0 25 40 55 70 85 Ambient Air Temperature (°C) 0 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (500 mV/div), Ch 2: Iout (5 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (1 V/div), Ch 2: Vin (20 V/div). Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 15 Input: Output: Current: Part No.: Technical Specification 18-75 V 15 V 14 A IQ36150HPx14 IQ36150HPx12 ELECTRICAL CHARACTERISTICS (15 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 36 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. INPUT CHARACTERISTICS Maximum Input Current No-Load Input Current Disabled Input Current Response to Input Transient Input Terminal Ripple Current Recommended Input Fuse OUTPUT CHARACTERISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection EFFICIENCY 100% Load 50% Load Typ. TBD 15 15.15 V ±0.1 ±0.1 ±0.3 ±0.3 225 15.375 % % mV V 180 80 60 78.0 15,000 mV mV A A V A mA µF 10 10 19.1 mV µs % % V 50% to 75% to 50% Iout max To within 1% Vout nom Across Pins 8&4; Common Figures 3-5; see Note 2 Across Pins 8&4 Over full temp range % % See Figure 1 for efficiency curve See Figure 1 for efficiency curve -225 14.625 0 0 66.0 90 40 72.0 0.9 1.1 0.093 89.5 100 4 75 500 -20 17.6 Units Notes & Conditions A mA mA V mA A 80 1.8 0.15 170 14.85 Max. 18.3 83 87 Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 1 Full load Full load Subject to thermal derating Output voltage 10% Low Negative current drawn from output Negative current drawn from output Vout nominal at full load (resistive load) Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at low line and full load. Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 16 Input: Output: Current: Part No.: Technical Specification 100 26 24 95 22 20 Power Dissipation (W) 90 Efficiency (%) 85 80 75 70 18 Vin 36 Vin 75 Vin 65 60 18 16 14 12 10 8 6 4 18 Vin 36 Vin 2 75 Vin 0 0 2 4 6 8 10 12 14 0 2 4 Load Current (A) 6 8 10 12 14 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 16 14 14 12 12 10 10 Iout (A) 16 Iout (A) 18-75 V 15 V 14 A IQ36150HPx14 8 6 8 6 400 LFM (2.0 m/s) 4 200 LFM (1.0 m/s) 2 400 LFM (2.0 m/s) 4 300 LFM (1.5 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 2 100 LFM (0.5 m/s) 0 100 LFM (0.5 m/s) 0 0 25 40 55 70 85 Ambient Air Temperature (°C) 0 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic and 15 µF tantalum capacitors. Ch 1: Vout (500 mV/div), Ch 2: Iout (5 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (1 V/div), Ch 2: Vin (20 V/div). Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 17 Input: Output: Current: Part No.: Technical Specification 18-75 V 24 V 9A IQ36240HPx09 IQ36240HPx7F ELECTRICAL CHARACTERISTICS (24 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 36 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current 143.1 A Vin min; trim up; in current limit No-Load Input Current 80 100 mA Disabled Input Current 1.8 4 mA Response to Input Transient 0.15 V See Figure 6 Input Terminal Ripple Current 170 mA RMS Recommended Input Fuse TBD A Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 23.76 24 24.24 V Output Voltage Regulation Over Line ±0.1 ±0.3 % Over Load ±0.1 ±0.3 % Over Temperature -360 360 mV Total Output Voltage Range 23.40 24.60 V Over sample, line, load, temperature & life Output Voltage Ripple and Noise 20 MHz bandwidth; see Note 1 Peak-to-Peak 0 90 180 mV Full load RMS 40 80 mV Full load A Operating Output Current Range 0 60 Subject to thermal derating Output DC Current-Limit Inception 66.0 72.0 78.0 A Output voltage 10% Low Output DC Current-Limit Shutdown Voltage 0.9 V Back-Drive Current Limit while Enabled 1.1 A Negative current drawn from output Back-Drive Current Limit while Disabled 0.093 mA Negative current drawn from output Maximum Output Capacitance 15,000 µF Vout nominal at full load (resistive load) Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 75 mV 50% to 75% to 50% Iout max Settling Time 500 µs To within 1% Vout nom Output Voltage Trim Range -20 10 % Across Pins 8&4; Common Figures 3-5; see Note 2 Output Voltage Remote Sense Range 10 % Across Pins 8&4 Output Over-Voltage Protection 28.1 29.3 30.5 V Over full temp range EFFICIENCY 100% Load 83 % See Figure 1 for efficiency curve 50% Load 87 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at low line and full load. Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 18 Input: Output: Current: Part No.: Technical Specification 100 30 28 95 26 Power Dissipation (W) Efficiency (%) 90 85 80 75 70 18 Vin 36 Vin 75 Vin 65 24 22 20 18 16 14 12 10 8 6 1 2 3 4 5 6 7 8 9 0 Load Current (A) 2 3 4 5 6 7 8 9 Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 10 9 9 8 8 7 7 6 6 Iout (A) 10 Iout (A) 1 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 5 4 5 4 3 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 2 200 LFM (1.0 m/s) 1 75 Vin 2 0 0 2 18 Vin 36 Vin 4 60 3 18-75 V 24 V 9A IQ36240HPx09 200 LFM (1.0 m/s) 1 100 LFM (0.5 m/s) 0 100 LFM (0.5 m/s) 0 0 25 40 55 70 85 Ambient Air Temperature (°C) 0 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic capacitor. Ch 1: Vout (1 V/div), Ch 2: Iout (2 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (1 V/div), Ch 2: Vin (20 V/div). Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 19 Input: Output: Current: Part No.: Technical Specification 18-75 V 28 V 7.5 A IQ36280HPx7F IQ36280HPx6F ELECTRICAL CHARACTERISTICS (28 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 36 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current 167.0 A Vin min; trim up; in current limit No-Load Input Current 80 100 mA Disabled Input Current 1.8 4 mA Response to Input Transient 0.15 V See Figure 6 Input Terminal Ripple Current 170 mA RMS Recommended Input Fuse TBD A Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 27.72 28 28.28 V Output Voltage Regulation Over Line ±0.1 ±0.3 % Over Load ±0.1 ±0.3 % Over Temperature -420 420 mV Total Output Voltage Range 27.30 28.70 V Over sample, line, load, temperature & life Output Voltage Ripple and Noise 20 MHz bandwidth; see Note 1 Peak-to-Peak 0 90 180 mV Full load RMS 40 80 mV Full load A Operating Output Current Range 0 60 Subject to thermal derating Output DC Current-Limit Inception 66.0 72.0 78.0 A Output voltage 10% Low Output DC Current-Limit Shutdown Voltage 0.9 V Back-Drive Current Limit while Enabled 1.1 A Negative current drawn from output Back-Drive Current Limit while Disabled 0.093 mA Negative current drawn from output Maximum Output Capacitance 15,000 µF Vout nominal at full load (resistive load) Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 75 mV 50% to 75% to 50% Iout max Settling Time 500 µs To within 1% Vout nom Output Voltage Trim Range -20 10 % Across Pins 8&4; Common Figures 3-5; see Note 2 Output Voltage Remote Sense Range 10 % Across Pins 8&4 Output Over-Voltage Protection 32.8 34.2 35.6 V Over full temp range EFFICIENCY 100% Load 83 % See Figure 1 for efficiency curve 50% Load 87 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at low line and full load. Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 20 Input: Output: Current: Part No.: Technical Specification 28 100 26 95 24 22 Power Dissipation (W) 90 85 Efficiency (%) 18-75 V 28 V 7.5 A IQ36280HPx7F 80 75 70 20 18 16 14 12 10 65 8 6 18 Vin 36 Vin 75 Vin 60 4 18 Vin 36 Vin 2 75 Vin 0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 0.0 1.0 2.0 Load Current (A) 3.0 4.0 5.0 6.0 7.0 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 7 7 6 6 5 5 Iout (A) 8 Iout (A) 8 4 4 3 3 400 LFM (2.0 m/s) 2 200 LFM (1.0 m/s) 1 400 LFM (2.0 m/s) 2 300 LFM (1.5 m/s) 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 1 100 LFM (0.5 m/s) 0 100 LFM (0.5 m/s) 0 25 40 55 70 85 Ambient Air Temperature (°C) 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic capacitor. Ch 1: Vout (2 V/div), Ch 2: Iout (2 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (1 V/div), Ch 2: Vin (20 V/div). Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 21 Input: Output: Current: Part No.: Technical Specification 18-75 V 40 V 5.5 A IQ36400HPx5F IQ36400HPx4F ELECTRICAL CHARACTERISTICS (40 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 36 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current 238.6 A No-Load Input Current 80 100 mA Disabled Input Current 1.8 4 mA Response to Input Transient 0.15 V Input Terminal Ripple Current 170 mA Recommended Input Fuse Vin min; trim up; in current limit See Figure 6 RMS TBD A Fast acting external fuse recommended 40 40.4 V Over Line ±0.1 ±0.3 % Over Load ±0.1 ±0.3 % -600 600 mV 39.00 41.00 V 90 180 mV Full load 40 80 mV Full load 60 A Subject to thermal derating 78.0 A Output voltage 10% Low OUTPUT CHARACTERISTICS Output Voltage Set Point 39.6 Output Voltage Regulation Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak 20 MHz bandwidth; see Note 1 0 RMS Operating Output Current Range Output DC Current-Limit Inception Over sample, line, load, temperature & life 0 66.0 72.0 Output DC Current-Limit Shutdown Voltage 0.9 V Back-Drive Current Limit while Enabled 1.1 A Negative current drawn from output Back-Drive Current Limit while Disabled 0.093 mA Negative current drawn from output µF Vout nominal at full load (resistive load) Maximum Output Capacitance 15,000 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 75 mV 50% to 75% to 50% Iout max Settling Time 500 µs To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5; see Note 2 10 % Across Pins 8&4 50.8 V Over full temp range Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 46.8 48.8 EFFICIENCY 100% Load 83 % See Figure 1 for efficiency curve 50% Load 87 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at low line and full load. Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 22 Input: Output: Current: Part No.: Technical Specification 100 30 28 95 26 Power Dissipation (W) 90 85 Efficiency (%) 18-75 V 40 V 5.5 A IQ36400HPx5F 80 75 70 24 22 20 18 16 14 12 10 8 6 18 Vin 36 Vin 75 Vin 65 18 Vin 36 Vin 4 75 Vin 2 60 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 0.0 Load Current (A) 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 5.5 5.0 5.0 4.5 4.5 4.0 4.0 3.5 3.5 Iout (A) 6.0 5.5 Iout (A) 6.0 3.0 3.0 2.5 2.5 2.0 2.0 400 LFM (2.0 m/s) 1.5 1.0 0.5 400 LFM (2.0 m/s) 1.5 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 1.0 100 LFM (0.5 m/s) 0.5 0.0 300 LFM (1.5 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 0.0 25 40 55 70 85 Ambient Air Temperature (°C) 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic capacitor. Ch 1: Vout (2 V/div), Ch 2: Iout (2 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (1 V/div), Ch 2: Vin (20 V/div). Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 23 Input: Output: Current: Part No.: Technical Specification 18-75 V 48 V 4.5 A IQ36480HPx4F IQ36480HPx3H ELECTRICAL CHARACTERISTICS (48 Vout) Ta = 25 °C, airflow rate = 300 LFM, Vin = 36 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions INPUT CHARACTERISTICS Maximum Input Current 286.3 A No-Load Input Current 80 100 mA Disabled Input Current 1.8 4 mA Response to Input Transient 0.15 V Input Terminal Ripple Current 170 mA Recommended Input Fuse TBD A 48 48.48 V Over Line ±0.1 ±0.3 % Over Load ±0.1 ±0.3 % -720 720 mV 46.80 49.20 V Vin min; trim up; in current limit See Figure 6 RMS Fast acting external fuse recommended OUTPUT CHARACTERISTICS Output Voltage Set Point 47.52 Output Voltage Regulation Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak 20 MHz bandwidth; see Note 1 0 RMS Operating Output Current Range Output DC Current-Limit Inception Over sample, line, load, temperature & life 90 180 mV Full load 40 80 mV Full load 60 A Subject to thermal derating 78.0 A Output voltage 10% Low 0 66.0 72.0 Output DC Current-Limit Shutdown Voltage 0.9 V Back-Drive Current Limit while Enabled 1.1 A Negative current drawn from output Back-Drive Current Limit while Disabled 0.093 mA Negative current drawn from output µF Vout nominal at full load (resistive load) Maximum Output Capacitance 15,000 Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 75 mV 50% to 75% to 50% Iout max Settling Time 500 µs To within 1% Vout nom 10 % Across Pins 8&4; Common Figures 3-5; see Note 2 10 % Across Pins 8&4 61.0 V Over full temp range Output Voltage Trim Range -20 Output Voltage Remote Sense Range Output Over-Voltage Protection 56.2 58.6 EFFICIENCY 100% Load 83 % See Figure 1 for efficiency curve 50% Load 87 % See Figure 1 for efficiency curve Note 1: Output is terminated with 1 µF ceramic and 15 µF low-ESR tantalum capacitors. For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 2: Trim-up range is limited below 10% at low line and full load. Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 24 Input: Output: Current: Part No.: Technical Specification 28 100 26 95 24 22 Power Dissipation (W) 90 85 Efficiency (%) 18-75 V 48 V 4.5 A IQ36480HPx4F 80 75 70 20 18 16 14 12 10 8 6 18 Vin 36 Vin 75 Vin 65 60 4 18 Vin 36 Vin 2 75 Vin 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 0.0 0.5 1.0 1.5 Load Current (A) 2.0 2.5 3.0 3.5 4.0 4.5 Load Current (A) Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 4.5 4.0 4.0 3.5 3.5 3.0 3.0 Iout (A) 5.0 4.5 Iout (A) 5.0 2.5 2.5 2.0 2.0 1.5 1.5 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 1.0 200 LFM (1.0 m/s) 0.5 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 1.0 200 LFM (1.0 m/s) 0.5 100 LFM (0.5 m/s) 0.0 100 LFM (0.5 m/s) 0.0 25 40 55 70 85 Ambient Air Temperature (°C) 25 40 55 70 85 Ambient Air Temperature (°C) Figure 3: Encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows across the converter from input to output (nominal input voltage). Figure 5: Output voltage response to step-change in load current (50%-75%-50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 1 µF ceramic capacitor. Ch 1: Vout (2 V/div), Ch 2: Iout (2 A/div). Figure 6: Output voltage response to step-change in input voltage (1000 V/ms). Load cap: 100 µF, electrolytic output capacitance. Ch 1: Vout (1 V/div), Ch 2: Vin (20 V/div). Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 25 Technical Specification IQ36-HP Family BASIC OPERATION AND FEATURES CONTROL FEATURES This converter series uses a two-stage power topology. The first stage is a buck-converter that output voltage constant over variations in line, temperature. The second stage uses a transformer the functions of input/output isolation and voltage step-down to achieve the output voltage required. REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits the user to control when the converter is on or off. This input is referenced to the return terminal of the input bus, Vin(-). The ON/OFF signal is active low (meaning that a low turns the converter on). Figure A details four possible circuits for driving the ON/OFF pin. Figure B is a detailed look of the internal ON/ OFF circuitry. conversion keeps the load, and to provide step-up or Both the first stage and the second stage switch at a fixed frequency for predictable EMI performance. Rectification of the transformer’s output is accomplished with synchronous rectifiers. These devices, which are MOSFETs with a very low on-state resistance, dissipate far less energy than Schottky diodes. This is the primary reason that the converter has such high efficiency, even at very low output voltages and very high output currents. These converters are offered totally encased to withstand harsh environments and thermally demanding applications. Dissipation throughout the converter is so low that it does not require a heatsink for operation in many applications; however, adding a heatsink provides improved thermal derating performance in extreme situations. This series of converters use the industry standard footprint and pin-out configuration. ON/OFF ON/OFF Vin(_) Vin(_) Remote Enable Circuit REMOTE SENSE(+) (Pins 7 and 5): The SENSE(+) inputs correct for voltage drops along the conductors that connect the converter’s output pins to the load. Pin 7 should be connected to Vout(+) and Pin 5 should be connected to Vout(-) at the point on the board where regulation is desired. A remote connection at the load can adjust for a voltage drop only as large as that specified in this datasheet, that is [Vout(+) - Vout(-)] – [Vsense(+) - Vsense(-)] < Sense Range % x Vout Pins 7 and 5 must be connected for proper regulation of the output voltage. If these connections are not made, the converter will deliver an output voltage that is slightly higher than its specified value. Note: the output over-voltage protection circuit senses the voltage across the output (pins 8 and 4) to determine when it should trigger, not the voltage across the converter’s sense leads (pins 7 and 5). Therefore, the resistive drop on the board should be small enough so that output OVP does not trigger, even during load transients. Negative Logic (Permanently Enabled) 5V ON/OFF TTL/ CMOS 50k ON/OFF ON/OFF Vin(_) Vin(_) Open Collector Enable Circuit 5V 50k TTL Direct Logic Drive 100pF Figure A: Various circuits for driving the ON/OFF pin. Vin(_) Figure B: Internal ON/OFF pin circuitry Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 26 Technical Specification IQ36-HP Family OUTPUT VOLTAGE TRIM (Pin 6): The TRIM input permits the user to adjust the output voltage across the sense leads up or down according to the trim range specifications. To decrease the output voltage, the user should connect a resistor between Pin 6 and Pin 5 (SENSE(-) input). For a desired decrease of the nominal output voltage, the value of the resistor should be Rtrim-down = - 10.22 (511 ∆% ) (kW) where ∆% = Vnominal – Vdesired Vnominal x 100% To increase the output voltage, the user should connect a resistor between Pin 6 and Pin 7 (SENSE(+) input). For a desired increase of the nominal output voltage, the value of the resistor should be Rtrim-up = where ( 5.11VOUT x (100+∆%) 1.225∆% _ 511 _ 10.22 ∆% ) (kW) Vout = Nominal Output Voltage Trim graphs show the relationship between the trim resistor value and Rtrim-up and Rtrim-down, showing the total range the output voltage can be trimmed up or down. Note: the TRIM feature does not affect the voltage at which the output over-voltage protection circuit is triggered. Trimming the output voltage too high may cause the over-voltage protection circuit to engage, particularly during transients. It is not necessary for the user to add capacitance at the Trim pin. The node is internally bypassed to eliminate noise. Total DC Variation of VOUT: For the converter to meet its full specifications, the maximum variation of the dc value of VOUT, due to both trimming and remote load voltage drops, should not be greater than that specified for the output voltage trim range. Product # IQ36xxxHPXxx Phone 1-888-567-9596 PROTECTION FEATURES Input Under-Voltage Lockout: The converter is designed to turn off when the input voltage is too low, helping avoid an input system instability problem, described in more detail in the application note titled “Input System Instability” on our website. The lockout circuitry is a comparator with dc hysteresis. When the input voltage is rising, it must exceed the typical TurnOn Voltage Threshold value (listed on the specifications page) before the converter will turn on. Once the converter is on, the input voltage must fall below the typical Turn-Off Voltage Threshold value before the converter will turn off. Output Current Limit: The maximum current limit remains constant as the output voltage drops. However, once the impedance of the load across the output is small enough to make the output voltage drop below the specified Output DC CurrentLimit Shutdown Voltage, the converter turns off. The converter then enters a “hiccup mode” where it repeatedly turns on and off at a 5 Hz (nominal) frequency with a 5% duty cycle until the short circuit condition is removed. This prevents excessive heating of the converter or the load board. Output Over-Voltage Limit: If the voltage across the output pins exceeds the Output Over-Voltage Protection threshold, the converter will immediately stop switching. This prevents damage to the load circuit due to 1) excessive series resistance in output current path from converter output pins to sense point, 2) a release of a short-circuit condition, or 3) a release of a current limit condition. Load capacitance determines exactly how high the output voltage will rise in response to these conditions. After 200 ms the converter will automatically restart. Over-Temperature Shutdown: A temperature sensor on the converter senses the average temperature of the module. The thermal shutdown circuit is designed to turn the converter off when the temperature at the sensed location reaches the Over-Temperature Shutdown value. It will allow the converter to turn on again when the temperature of the sensed location falls by the amount of the Over-Temperature Shutdown Restart Hysteresis value. www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 27 Technical Specification IQ36-HP Family APPLICATION CONSIDERATIONS Input System Instability: This condition can occur because any dc-dc converter appears incrementally as a negative resistance load. A detailed application note titled “Input System Instability” is available on the SynQor website which provides an understanding of why this instability arises, and shows the preferred solution for correcting it. Application Circuits: Figure C provides a typical circuit diagram which details the input filtering and voltage trimming. Vin(+) External Input Filter Vin Electrolytic Capacitor Vout(+) Vsense(+) Trim ON/OFF Vsense(_) Vin(_) Rtrim-up or Rtrim-down Cload Iload Vout(_) Figure C: Typical application circuit (negative logic unit, permanently enabled). Input Filtering and External Capacitance: Figure D provides a diagram showing the internal input filter components. This filter dramatically reduces input terminal ripple current, which otherwise could exceed the rating of an external electrolytic input capacitor. The recommended external input capacitance is specified in the Input Characteristics section on the Electrical Characteristics page. More detailed information is available in the application note titled “EMI Characteristics” on the SynQor website. L Vin(+) C Vin(_) Figure D: Internal Input Filter Diagram (component values listed on the specifications page). Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 28 Technical Specification IQ36-HP Family Startup Inhibit Period: The Startup Inhibit Period ensures that the converter will remain off for approximately 200 ms when it is shut down for any reason. When an output short is present, this generates a 5 Hz “hiccup mode,” which prevents the converter from overheating. In all, there are seven ways that the converter can be shut down, initiating a Startup Inhibit Period: • Input Under-Voltage Lockout When the ON/OFF pin goes high after t2, the Startup Inhibit Period has elapsed, and the output turns on within the typical Turn-On Time. Thermal Considerations: The maximum operating base-plate temperature, TB, is 100 ºC. As long as the user’s thermal system keeps TB < 100 ºC, the converter can deliver its full rated power. A power derating curve can be calculated for any heatsink that is attached to the base-plate of the converter. It is only necessary to determine the thermal resistance, RTHBA, of the chosen heatsink between the base-plate and the ambient air for a given airflow rate. This information is usually available from the heatsink vendor. The following formula can the be used to determine the maximum power the converter can dissipate for a given thermal condition if its base-plate is to be no higher than 100 ºC. • Input Over-Voltage Shutdown • Output Over-Voltage Protection • Over Temperature Shutdown • Current Limit • Short Circuit Protection • Turned off by the ON/OFF input Figure E shows three turn-on scenarios, where a Startup Inhibit Period is initiated at t0, t1, and t2: Before time t0, when the input voltage is below the UVL threshold, the unit is disabled by the Input Under-Voltage Lockout feature. When the input voltage rises above the UVL threshold, the Input Under-Voltage Lockout is released, and a Startup Inhibit Period is initiated. At the end of this delay, the ON/OFF pin is evaluated, and since it is active, the unit turns on. At time t1, the unit is disabled by the ON/OFF pin, and it cannot be enabled again until the Startup Inhibit Period has elapsed. max Pdiss = 100 ºC - TA RTHBA This value of power dissipation can then be used in conjunction with the data shown in Figure 2 to determine the maximum load current (and power) that the converter can deliver in the given thermal condition. For convenience, power derating curves for an encased converter without a heatsink and with a typical heatsink are provided for each output voltage. Vin Under-Voltage Lockout TurnOn Threshold ON/OFF (neg logic) ON OFF ON Vout OFF ON 9ms (typical turn on time) 200ms (typical start-up inhibit period) t1 t0 200ms 200ms t2 t Figure E: Startup Inhibit Period (turn-on time not to scale) Product # IQ36xxxHPXxx Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 29 Technical Specification IQ36-HP Family PART NUMBERING SYSTEM ORDERING INFORMATION The part numbering system for SynQor’s dc-dc converters follows the format shown in the example below. The tables below show the valid model numbers and ordering options for converters in this product family. When ordering SynQor converters, please ensure that you use the complete 15 character part number consisting of the 12 character base part number and the additional characters for options. Add “-G” to the model number for 6/6 RoHS compliance. IQ 36 120 H P C 18 N R S - G 6/6 RoHS Options (see Ordering Information) Continuous Input Voltage 18-75 V 18-75 V 18-75 V 18-75 V 18-75 V 18-75 V 18-75 V 18-75 V 18-75 V 18-75 V Model Number IQ36018HPw60NRS IQ36033HPw50NRS IQ36050HPw40NRS IQ36070HPw30NRS IQ36120HPw18NRS IQ36150HPw14NRS IQ36240HPw09NRS IQ36280HPw7FNRS IQ36400HPw5FNRS IQ36480HPw4FNRS) Output Current Thermal Design Performance Level Package Size Output Voltage Input Voltage Product Family The first 12 characters comprise the base part number and the last 3 characters indicate available options. The “-G” suffix indicates 6/6 RoHS compliance. Application Notes A variety of application notes and technical white papers can be downloaded in pdf format from our website. RoHS Compliance: The EU led RoHS (Restriction of Hazardous Substances) Directive bans the use of Lead, Cadmium, Hexavalent Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor product is 6/6 RoHS compliant. For more information please refer to SynQor’s RoHS addendum available at our RoHS Compliance / Lead Free Initiative web page or e-mail us at [email protected]. Output Voltage 1.8 V 3.3 V 5.0 V 7.0 V 12 V 15 V 24 V 28 V 40 V 48 V Maximum Output Current 60 A 50 A 40 A 30 A 18 A 14 A 9.0 A 7.5 A 5.5 A 4.5 A The following options must be included in place of the w x y z spaces in the model numbers listed above. Options Description: w x y z Thermal Design Enable Logic Pin Style Feature Set C - Encased with Threaded Baseplate D - Encased with Non-Threaded Baseplate N - Negative R - 0.180" S - Standard Not all combinations make valid part numbers, please contact SynQor for availability. See the Product Summary web page for more options. PATENTS SynQor holds the following patents, one or more of which might apply to this product: 5,999,417 6,594,159 6,927,987 7,119,524 6,222,742 6,731,520 7,050,309 7,269,034 6,545,890 6,894,468 7,072,190 7,272,021 6,577,109 6,896,526 7,085,146 7,272,023 Contact SynQor for further information: Phone: Toll Free: Fax: E-mail: Web: Address: Product # IQ36xxxHPXxx 978-849-0600 888-567-9596 978-849-0602 [email protected] www.synqor.com 155 Swanson Road Boxborough, MA 01719 USA Phone 1-888-567-9596 Warranty SynQor offers a two (2) year limited warranty. Complete warranty information is listed on our website or is available upon request from SynQor. Information furnished by SynQor is believed to be accurate and reliable. However, no responsibility is assumed by SynQor for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SynQor. www.synqor.com Doc.# 005-0005231 Rev. A 05/26/09 Page 30