motion sensor EKMB(WL)series Current consumption 1/2/6μA Digital output ○Low current consumption for battery-driven applications ○A special differential input circuit design(EKMB 6μA type only) for applications where a high noise resistance is required(up to GHz range). Standard detection type Long distance detection type Recommended applications IoT, occupancy sensor module for smart home, battery-driven applications, wireless devices Lensless type available 6μA type: EKMB1300100K 1μA type: EKMB1100100 2μA type: EKMB1200100 Wall installation type Specifications Detection performance Model no. Standard detection type EKMB1101111 Current consumption EKMB1101112 Pearl white White 6μA EKMB1103111 Digital 102° 92° 92 12m(1st step lens) 6m(2nd step lens) 3m(3rd step lens) Please refer to page 8 for details. 40° 105° 68 Black Pearl white EKMB1104111 White 1μA Black EKMB1104113 Pearl white EKMB1204111 White 2μA Black EKMB1204113 Pearl white EKMB1304111K White 6μA EKMB1304113K Black Pearl white EKMB1 ●PaPIRs motion sensor ●Current consumption in standby mode 1: 1μA / 2: 2μA / 3: 6μA ●Detection(Lens) 00: Lensless / 01: 5m distance standard / 03: 12m long distance / 04: Wall installation type 5 Black 6μA EKMB1303113K information 12m White 2μA White ■ Ordering 64 Pearl white Pearl white EKMB1304112K 82° Black EKMB1303111K EKMB1204112 94° White EKMB1203113 EKMB1104112 5m Black 1μA EKMB1203111 EKMB1303112K Detection zones Pearl white EKMB1103113 Wall installation type Black EKMB1301111K EKMB1203112 Vertical White EKMB1201113 EKMB1103112 Horizontal Black 2μA EKMB1301113K Long distance detection type Detection area Detection distance Pearl white EKMB1201111 EKMB1301112K Output type White 1μA EKMB1101113 EKMB1201112 Lens color 1 ●Others K: 6μA / Blank: Other than 6μA ●Lens color 0: Lensless / 1: White / 2: Black / 3: Pearl white ● Lens 0: Lensless / 1:with lens Characteristics ■ Maximum rated values Items Value Power supply voltage -0.3 to 4.5V Ambient temperature -20 to +60℃ (No frost, no condensation) Storage temperature -20 to +70 ℃ ■ Electrical Characteristics Items Symbol Operating voltage Max Min 1μA type 2μA type 6μA type Conditions 4.0V Vdd ー 2.3V Current consumption (in standby mode) Note 1) Ave Iw Output current (during detection period) Note 2) Max Iout 100μA Ambient temperature: 25 ℃ Vout≧Vdd-0.5 Output voltage (during detection period) Min Vout Vdd‐0.5V Ambient temperature: 25 ℃ Open at no detection Circuit stability time (when voltage is applied) Ave Max 1μA Twu 2μA Ambient temperature: 25 ℃ Iout=0 Vdd: 3V 6μA 25 sec ー 210 sec 10 sec, Note 3) Ambient temperature: 25 ℃ Iout=0 Vdd: 3V Note 1) The total current consumption is equal to the current consumption in standby mode (Iw) plus the output current during detection (Iout). For the 1μA type please note that the average current consumption is 1μA in sleep mode and 1.9μA in standby mode. Please also refer to the timing chart. Note 2) Please select an output resistors (pull-down concept) in accordance with Vout so that the output current is lower than or equal to 100μA. If the output current is more than 100μA, this may cause false alarms. Note 3) The sensor temperature has to be constant for the time specified. Timing chart ■ 2μA / 6μA type ■ 1μA type ON ON Power supply Power supply OFF OFF Present Present Detecting target Detecting target Absent Absent ON Output voltage Mode OFF 1)Sleep 2)Standby 3)Mask Unstable 1) 2) 3) 1) 2) 3) 1) 2) 3) Twu ON 【Explanation of the timing】 Twu: Circuit stability time: about 25 sec (typ.) for 2μA type, max. 10 sec for 6μA type. While the circuitry is stabilizing after the power is turned on, the sensor output is not fixed in the ON or OFF state. This is true regardless of whether or not the sensor has detected anything. Output voltage OFF t1(Twu) t2 t3 t2 t3 t2 ※2 ※1 【Explanation of modes】 1)Sleep mode: When the output is OFF. The electrical current consumption is around 1μA. 2) Standby mode: After the sensor's output has reached ON status, the sensor switches to standby mode. The electrical current consumption gets close to 1.9μA . When the sensor's output returns to its OFF value after the "hold time" has expired, the sensor switches again to sleep mode. 3) Mask mode: Time during which the output is forced to OFF status after the end of the standby mode. (No detection is possible during this period.) 【Explanation of the timing】 t1 (Twu): Circuit stability time: about 25 sec (typ.) While the circuitry is stabilizing after the power is turned on, the sensor output is not fixed in the ON or OFF state. This is true regardless of whether or not the sensor has detected anything. t2: Standby hold time: about 2.6 sec (typ.) after the last detection of a signal. (※1) t3: Mask time: about 1.3 sec (typ.) During this stage, even if the sensor detects something, the output will not switch to ON.(※2) 6 Lenses for the EKMB/EKMC series Dimension Detection zone (mm) Detection characteristics Y Standard detection type 5m Y Detection distance Field of view Detection zone Detection condition 2.5m φ9.5 CAD data (48.5° ) 41° A A 13 φ0.45 ±0.05 5.6m X 14.4 4.6 φ11 VDD GND 45°±4 6.6m X-Y Cross Section (48.5° )41° P.C.D.φ5. 08 ±0.2 OUT SIDE VIEW ±4 45° Max. 5m ×82 ° 94 ° 64 beams ・The temperature difference between the target and the surroundings must be higher than 4℃. ・Movement speed: 1.0m/s 47° (53° ) ・Target concept: Human 47° (53° ) body with an approx. size of 700×250mm X A-A Cross sectional ・Target moving direction: Crossing the detection beam. TOP VIEW 5m Y 12m Long distance detection type 2.5m (49.5° ) 46.3° Y CAD data Detection distance Field of view Detection zone Detection condition 5m 22 φ20.7 11.6m X 20.2 A A 7.3 φ0.45 ±0.05 P.C 4.6 φ11 .D.φ 5.0 ± 8 0 13.8m X-Y Cross Section VDD .2 2.5 GND 46.3° (49.5° ) 5 OUT 45°± 4° SIDE VIEW ° ±4 45° Max. 12m ×92 ° 102 ° 92 beams ・The temperature difference between the target and the surroundings must be higher than 4℃. ・Movement speed: 1.0m/s 51.3° (54° ) 51.3° (54° ) ・Target concept: Human body with an approx. size of 700×250mm X ・Target moving direction: Crossing the detection beam. TOP VIEW 12m A-A Cross sectional Wall installation type 5m Detection distance Y φ22 φ20.7 CAD data 5.7m 2nd step 18° 25° A 20.2 A φ0.45 ±0.05 4.6 X-Y Cross Section SIDE VIEW φ11 .D.φ 5.0 ± 8 0 3rd step 14.9m 44° 5m (49° ) 12m 7.3 P.C 1st step 4° VDD .2 2.5 GND 52.5° (56° ) 5 OUT 45°± 4° X Field of view Detection zone Detection condition 52.5° (56° ) 5m ° ±4 45° TOP VIEW 12m 1st step lens Max. 12m 2nd step lens Max. 6m 3rd step lens Max. 3m ×105 ° 40 ° 68 beams ・The temperature difference between the target and the surroundings must be higher than 4℃. ・Movement speed: 1.0m/s ・Target concept: Human body with an approx. size of 700×250mm ・Target moving direction: Crossing the detection beam. A-A Cross sectional ■ PIR element Lensless type 3.0 0.6mm 3.0 Average: 5.6μW/c ㎡ Detection sensitivity 0.4mm φ9.1 φ8.3 55° 0.6mm Maximum: 7.6μW/c ㎡ ELEMENT 9.3 8.4 ※Detection sensitivity is measured by following system 0.6mm 0.6mm 0.4mm ■ Test setup φ0.45 ±0.05 5.5 P.C .D.φ 5.08 ±0 Black body 250℃ Aperture φ3.2mm Masking plate PaPIRs VDD DC5V .2 GND OUT 45°± 4° 340mm Chopper (1Hz) ° ±4 45° CAD data CAD data can be downloaded from the PaPIRs WEB site. Panasonic PaPIRs Recorder Search Please refer to the formal specification for the dimension, and the tolerance ※Please note that the horizontal and vertical field of view depends on the position of the metal tab on which the lens is mounted. 8 SATURN LENS – NEW Dual zone 90° 90° 44° 44° Standard motion detection area 2.2m 1.8m Slight motion detection area ø4.4m Standard and slight-motion detection type Choose by the current consumption in standby mode 1μA (1μA type: in sleep mode) 2μA Choose by output 6μA Digital 170μA Digital Analog White EKMB1193111 EKMB1293111 EKMB1393111K EKMC1693111 By request Black EKMB1193112 EKMB1293112 EKMB1393112K EKMC1693112 By request Pearl white EKMB1193113 EKMB1293113 EKMB1393113K EKMC1693113 By request Choose by lens color Saturn lens Dimension Detection zone (mm) Standard and slightmotion detection type Detection characteristics Detection distance Vertical Slight motion detection area CAD data by request 14.9 14.1 17.2 7.9 A (0.018 dia) 4.6 0.45 ±0.05 11 P.C.D 5.08 ±0.2 Max. 2.2m* Slight motion Standard motion Slight motion Standard motion 2 4.5 GND OUT 45 4° °± 44° x 44° 90° x 90° 36 48 • The temperature difference between the target and the surroundings must be higher than 4°C. • Movement speed: 0.5ms • Target concept: Human head with an approx. size of 200x200mm • Target moving direction: Crossing the detection beam, 1 zone Standard motion • The temperature VDD ±4° Field of view Detection zone Detection Slight motion condition ▲ A 45° Standard motion detection area Horizontal difference between the target and the surroundings must be higher than 4°C. • Movement speed: 1.0ms • Target concept: Human body with an approx. size of 400x200mm • Target moving direction: Crossing the detection beam, 2 zones * Under specified detection conditions ▲ Please refer to “Caution for use” (page 13) and “Basic principles”(page 13, point 5), for more details Please contact your local sales representative for detailed specifications.