OPTREX F-51167NCU-FW-AB Lcd module specification Datasheet

First Edition
Approved by
Production Div.
May 2, 2000
LCD Module Specification
Checked by
Quality Assurance Div.
Checked by
Design Engineering Div.
Prepared by
Production Div.
Final Revision
********
Type No.
F-51167NCU-FW-AB
Table of Contents
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
General Specifications ............................................................................ 2
Electrical Specifications.......................................................................... 3
Optical Specifications ............................................................................. 8
I/O Terminal.......................................................................................... 10
Test......................................................................................................... 12
Appearance Standards........................................................................... 13
Code System of Production Lot ......................................................... 15
Type Number ........................................................................................ 15
Applying Precautions............................................................................ 15
Precautions Relating Product Handling .............................................. 16
Warranty................................................................................................. 17
Revision History
Rev.
Date
F-51167NCU-FW-AB
Page
(AB)
No.2000-0182
Comment
OPTREX
OPTREX CORPORATION
Page 1/17
1.General Specif ications
Operating Temp.
: min. 0℃ ~ max. 50℃
Storage Temp.
: min. -20℃ ~ max. 70℃
Dot Pixels
: 320×3 [R.G.B] (W) × 240 (H) dots
Dot Size
: 0.10 (W) × 0.34 (H) mm
Dot Pitch
: 0.12 (W) × 0.36 (H) mm
Viewing Area
: 122.0 (W) × 92.0 (H) mm
Outline Dimensions
: 167.1* (W) × 109.0 (H) × 8.0 max. (D) mm
* Without CFL Cable
Weight
: 204g max.
LCD Type
: CTD-17753
( F-STN / Color-mode / Transmissive )
Viewing Angle
: 12:00
Data Transfer
: 8-bit parallel data transfer
Duty
: 1/240 Duty
Backlight
: Cold Cathode Fluorescent Lamp (CFL) × 1
Additional Spec.
: Wide Viewing Type
Drawings
: Dimensional Outline
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
UE-300830
OPTREX CORPORATION
Page 2/17
2.Electrical Specif ications
2.1.Absolute Maximum Ratings
GND=0V
Parameter
Supply Voltage
Symbol
Conditions
Min.
Max.
Units
VCC1-GND
-
-0.3
7.0
V
VCC2-GND
-
0
6.0
V
VI
-
-0.3
VCC1+0.3
V
VCONT-GND
-
0
3.0
V
(Logic)
Supply Voltage
(LCD Drive)
Input Voltage
VCONT
Input Voltage
2.2.DC Characteristics
Ta=25℃, GND=0V
Parameter
Supply Voltage
Symbol
Conditions
Min.
Typ.
Max.
Units
VCC1-GND
-
3.0
-
5.5
V
VCC2-GND
-
3.0
-
5.5
V
-
0.8
-
2.7
V
(Logic)
Supply Voltage
(LCD Drive)
Voltage for Contrast VCONT-GND
Adjustment (Note1)
High Level
VIH
VCC1=3.0~5.5V
0.8× VCC1
-
VCC1
V
VIL
VCC1=3.0~5.5V
0
-
0.2× VCC1
V
ICC
VCC1-GND=5.0V
-
40.0
60.0
mA
-
-
30
MHz
Input Voltage
Low Level
Input Voltage
Supply Current
(Note2)
Clock Frequency
VCC2-GND=5.0V
fCP
VCC1=2.7~5.5V
Duty=50%
Note1:The relation between Voltage for Contrast Adjustment and LCD Contrast is shown as follows;
0.8V(Bright)~2.7V(dark)
Note2:Supply current which checker pattern displayed.
ICC= ICC1+ ICC2
fF=70Hz
VD=24.5
R G B R G B R G B R G B
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
OPTREX CORPORATION
Page 3/17
2.3. AC Characteristics
VCC1=2.7~5.5V
Parameter
Symbol
LP Low Level Width
Rise/Fall Time
FLM Setup Time
FLM Hold Time
CP Cycle Time
CP High Level Width
CP Low Level Width
LP Setup Time 1
LP Setup Time 2
LP Hold Time
Data Setup Time
Data Hold Time
LP ↑ to CP ↑
LP ↓ to CP ↓
DISPOFF Low Level Width
Max.
Units
tLP
-
5
-
ns
tWLH
tWLL
tr, td
tst
thd
tCP
tWCH
tWCL
tst1
tst2
thd1
tst3
thd2
tLH
tLS
tWDL
tSD
-
40
-
ns
-
1000
-
ns
Note 1
-
6.6
ns
-
60
-
ns
-
30
-
ns
-
40
-
ns
-
15
-
ns
-
15
-
ns
-
30
-
ns
-
30
-
ns
-
15
-
ns
-
15
-
ns
-
15
-
ns
-
25
-
ns
-
25
-
ns
-
100
-
ns
LP Cycle Time
LP High Level Width
Min.
DISPOFF Cancellation Time
20
-
-
Note 1:The rise and fall times (tr, tf ) must satisfy the following relationships.
tr, tf≦(1/f-2×tW)/2
tW:Minimum palse width
f:frequency
ns
tLP
tWLH
tWLL
tLH
VIH
LP
VIL
tst2
tWCH
CP
tst1
tLS
tWCL
thd1
tCP
VIH
VIL
tst3
thd2
D0~D7
LAST DATA
VIH
VIL
TOP DATA
tST
thd
VIH
FLM
tWDL
tSD
DISPOFF
VIH=0.8×VCC1
VIL=0.2×VCC1
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
OPTREX CORPORATION
Page 4/17
2.4.Timing Chart
T=0.0595ms typ.
LP
CP
D0
~
SEG
SEG
SEG
SEG
D7
945~
952
953~
960
1~
8
9~
16
#1 DATA
SEG
SEG
SEG
SEG
945~
952
953~
960
1~
8
9~
16
FLM
LP
(Reduction)
240×T
FLM
(Reduction)
2.5.Comparison of Display and Data
SEG1
#1
D7
SEG960
D6
D5
D4
D1
D0
TOP VIEW
D0~D7
#240
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
OPTREX CORPORATION
Page 5/17
2.6.Power Supply ON/OFF Sequence
2.6.1.ON Sequence
SIGNAL
LEVEL
VCC1,VCC2
VCC1,VCC2
GND
0≦t
VCC1
SIGNAL
50 ms≦t
GND
VCC1
DISPOFF
GND
2.6.2.OFF Sequence
LEVEL
SIGNAL
VCC1,VCC2
GND
0≦t
VCC1,VCC2
VCC1
GND
SIGNAL
TBD ms≦t
VCC1
GND
DISPOFF
Please maintain the above sequence when turning on and off the power supply of the module.
If DISPOFF is supplied to the module while internal alternate signal for LCD driving (M) is
unstable, DC component will be supplied to the LCD panel. This may cause damage the LCD
module.
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
OPTREX CORPORATION
Page 6/17
2.7.Lighting Specifications
Ta=25℃
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Units
Notes
Lamp Voltage
VL
-
-
430
-
Vrms
1
Lamp Current
IL
-
4.0
5.0
6.0
mArms
2
Starting Voltage
VS
-
-
-
700
Vrms
3
Surface Luminance
L
IL = 5.0 mA
80
120
-
cd/㎡
4
Average Life
TAL
IL = 5.0 mA
20000
hrs
5
-
-
Note 1 : The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after lighting for
3 minutes .
Note 2 : The current ( r.m.s. ) to flow through the lamp with the electric discharge. It is measured after
lighting for 3 minutes.
Note 3 : The voltage at starting the electric discharge when the voltage is increased gradually from 0V.
Note 4 : Surface Luminance is specified by the average of 9 luminance values measured at each point
shown above after 20 minutes power on with the all ON pattern adjusted to maximum contrast and
the dimming control of 100%. ( maximum brightness )
Note 5 : CFL life is defined as the time for which the initial luminance is attenuated by 50% of the
luminance value. Average Life representes the time elapsed at the point of time when the residual
ratio becomes below 50% when plural lamps are lighted in comparison with the definition of life
mentioned above.
Y=60
I
N
C
VS
VL
V
Y=160
Y=260
P1
P2
P3
P4
P5
P6
P7
P8
P9
F
L
X=60
X=120
X=180
IL
Measurement Points
CFL Testing Circuit
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
OPTREX CORPORATION
Page 7/17
3.Optical Specif ications
3.1.Optical Characteristics
Ta=25℃, 1/240 Duty,1/16 Bias, VOD=24.5V, θ= 0 ゚, φ=-゚
Parameter
Contrast Ratio
Symbol
Conditions
Min.
Typ.
Max.
CR
θ= 0 ゚, φ=-゚
-
20
-
x
-
-
0.324
-
y
-
-
0.361
-
Note 1
Chromaticity (white)
Viewing Angle
Response
Units
Shown in 3.3
Rise
Note 2
TON
-
-
540
810
ms
Time
Decay Note 3
TOFF
160
240
ms
-
-
Note 1 : Contrast ratio is definded as follows.
CR = LON / LOFF
LON : Luminance of the ON segments
LOFF : Luminance of the OFF segments
Note 2 : The time that the luminance level reaches 90% of the saturation level from 0% when ON
signal is applied.
Note 3 : The time that the luminance level reaches 10% of the saturation level from 100% when OFF
signal is applied.
Note 4 : Definition of Driving Voltage VOD
VOD= VCC1-VADJ-VBE
Assuming that the typical driving waveforms shown below are applied to the LCD Panel at
1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage VOD is definded
as the voltage VO-P when the contrast ratio (CR=LON / LOFF) is at its maximum.
VO-P
( B-2 )×VO-P / B
1 / ( f F× A )
1 / fF
〈ON SIGNAL〉
F-51167NCU-FW-AB
(AB)
No.2000-0182
〈OFF SIGNAL〉
OPTREX
OPTREX CORPORATION
Page 8/17
3.2.Definition of Viewing Angle and Optimum Viewing Area
・Point ● shows the point where contrast ratio is measured. : θ= 0 ゚, φ=-゚
・Driving condition : 1/240 Duty,1/16 Bias, VOD= 24.5V(Shown in 3.1 Note4), fF=70Hz
90 ゚
45 ゚
135 ゚
θ
φ
180 ゚
10 20 30 40 50
90 ゚
(φ= 0 ゚)
θ
φ
180 ゚
225 ゚
0゚
315 ゚
270 ゚
270 ゚
・Area
shows typ. CR≧2
3.3.System Block Diagram
Temperature Chamber
Rotation Table (θ,φ)
Photometer
#1980A WB
LCD
φ
Optical Fiber
θ
Control Unit &
Computer
Waveform Generator
Halogen bulb
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
OPTREX CORPORATION
Page 9/17
4.I/O Terminal
4.1.Pin Assignment
CN1
No.
Symbol
Level
Function
1
D0
H/L
Display Data
2
D1
H/L
Display Data
3
D2
H/L
Display Data
4
D3
H/L
Display Data
5
D4
H/L
Display Data
6
D5
H/L
Display Data
7
D6
H/L
Display Data
8
D7
H/L
Display Data
9
DISP OFF
H/L
Display Control Signal
10
FLM
H/L
First Line Marker
11
LP
H→L
Data Latch Signal
12
CP
H→L
Clock Signal for Shifting Data
13
M
H/L
Alternate Signal for LCD Drive
14
VCC1
-
Power Supply for Logic
15
VSS
―
Power Supply (0V, GND)
16
VSS
―
Power Supply (0V, GND)
17
VCC2
-
Power Supply for LCD Drive
18
CN2
VADJ
―
Voltage Level for LCD Contrast Adjustment
No.
Symbol
Level
1
HOT
-
Power Supply for CFL (HOT)
2
NC
-
Non-connection
3
NC
-
Non-connection
4
LGND
-
Power Supply for CFL (GND)
H : Display on
L : Display off
Function
4.2.Example of Power Supply
It is recommended to apply a potentiometer for the contrast adjust due to the tolerance
of the driving voltage and its temperature dependence.
3.3V
R1
VR
VCONT
MODULE
R2
GND
GND
VCC1
VCC1
VCC2
VCC2
R1+R2+VR=10~20KΩ
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
OPTREX CORPORATION
Page 10/17
4.3.Block Diagram
8
D0~D7
SEG.DRIVER
MN863830 × 4
or equivalent
CP
2
LP
DISPOFF
1
2
960
M
M CIRCUIT
240
COM.DRIVER
MN86372 × 2
or equivalent
FLM
L C D P
320×3[RGB]×240dots
TO LSI LOGIC
VCC1
VCC2
VADJ
DC/DC Converter+
Bias circuit
TO LSI
VSS
CFL
HOT
LGND
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
OPTREX CORPORATION
Page 11/17
5.Test
No change on display and in operation under the following test condition.
No.
Parameter
Conditions
Notes
1
High Temperature Operating
50℃±2℃, 96hrs (operation state)
2
Low Temperature Operating
0℃±2℃, 96hrs (operation state)
3
3
High Temperature Storage
70℃±2℃, 96hrs
4
4
Low Temperature Storage
-20℃±2℃, 96hrs
3, 4
5
Damp Proof Test
40℃±2℃, 90~95%RH, 96hrs
3, 4
6
Vibration Test
Total fixed amplitude : 1.5mm
5
Vibration Frequency : 10~55Hz
One cycle 60 seconds to 3 directions of X, Y, Z for
each 15 minutes
7
Shock Test
To be measured after dropping from 60cm high on
the concrete surface in packing state.
F
E
G
B
D
C
A
60cm
Concrete Surface
Dropping method corner dropping
A corner : once
Edge dropping
B,C,D edge : once
Face dropping
E,F,G face : once
Note 1 : Unless otherwise specified, tests will be conducted under the following condition.
Temperature : 20±5℃
Humidity
: 65±5%
Note 2 : Unless otherwise specified, tests will be not conducted under functioning state.
Note 3 : No dew condensation to be observed.
Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity
after removed from the test chamber.
Note 5 : Vibration test will be conducted to the product itself without putting it in a container.
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
OPTREX CORPORATION
Page 12/17
6.Appearance Standards
6.1.Inspection conditions
The LCD shall be inspected under 40W white fluorescent light.
The distance between the eyes and the sample shall be more than 30cm.
All directions for inspecting the sample should be within 45 ゚ against perpendicular line.
45゚
6.2.Definition of applicable Zones
A Zone
Bezel Flame
B Zone
C Zone
A Zone : Active display area
B Zone : Area from outside of "A Zone" to validity viewing area
C Zone : Rest parts
A Zone + B Zone = Validity viewing area
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
OPTREX CORPORATION
Page 13/17
6.3.Standards
No.
1
Parameter
Black and
Criteria
(1) Round Shape
White Spots,
Foreign Substances
Zone
Acceptable Number
Dimension (mm)
A
B
C
D ≦0.1
*
*
*
0.1 < D ≦0.2
3
5
*
0.2 < D ≦0.25
2
3
*
0.25< D ≦0.3
0
1
*
0.3 < D
0
0
*
D = ( Long + Short ) / 2
* : Disregard
(2) Line Shape
Zone
X (mm)
Acceptable Number
Y (mm)
A
B
C
-
0.03≧W
*
*
*
2.0≧L
0.05≧W
3
3
*
1.0≧L
0.1 ≧W
3
3
*
-
0.1 <W
X : Length
Y : Width
In the same way (1)
* : Disregard
Total defects shall not exceed 5.
2
Air Bubbles
(between glass
& polarizer)
Zone
Dimension (mm)
Acceptable Number
A
B
C
D ≦ 0.3
*
*
*
0.3 < D ≦ 0.4
3
*
*
0.4 < D ≦ 0.6
2
3
*
0.6 < D
0
0
*
* : Disregard
Total defects shall not exceed 3.
3
The Shape of Dot
However, each pixel shall remain more than one-third of the original
pixel size.
4
Polarizer Scratches
Not to be conspicuous defects.
5
Polarizer Dirts
If the stains are removed easily from LCDP surface, the module is not
defective.
6
7
Complex Foreign
Black spots, line shaped foreign substances or air bubbles between
Substance Defects
glass & polarizer should be 5pcs maximum in total.
Distance between
D≦0.2 : 20mm or more
Different Foreign
0.2<D : 40mm or more
Substance Defects
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
OPTREX CORPORATION
Page 14/17
7.Code System of Production Lot
The production lot of module is specified as follows.
□
□
□
□
□
□
Factory Number (Numeral)
Factory Code (Alphabet)
Production Week (1~5)
Production Month (1~9, X, Y, Z)
Production Year (Lower 2 digits)
8.Type Number
The type number of module is specified on the back of module as follows.
F-51167NCU-FW-AB
Seal
9.Applying Precautions
Please contact us when questions and/or new problems not specified in this specifications arise.
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
OPTREX CORPORATION
Page 15/17
10. Precautions Relating Product Handling
The Following precautions will guide you in handling our product correctly.
1) Liquid crystal display devices
① The liquid crystal display device panel used in the liquid crystal display module is made of plate
glass. Avoid any strong mechanical shock. Should the glass break handle it with care.
The
polarizer adhering to the surface of the LCD is made of a soft material.
②
Guard against scratching it.
2) Care of the liquid crystal display module against static electricity discharge.
① When working with the module, be sure to ground your body and any electrical equipment you may
be using. We strongly recommend the use of anti static mats ( made of rubber ), to protect work
tables against the hazards of electrical shock.
② Avoid the use of work clothing made of synthetic fibers. We recommend cotton clothing or other
conductivity-treated fibers.
③ Slowly and carefully remove the protective film from the LCD module, since this operation can
generate static electricity.
3) When the LCD module alone must be stored for long periods of time:
① Protect the modules from high temperature and humidity.
② Keep the modules out of direct sunlight or direct exposure to ultraviolet rays.
③ Protect the modules from excessive external forces.
4) Use the module with a power supply that is equipped with an overcurrent protector circuit,
since the module is not provided with this protective feature.
5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should hands
or clothing come in contact with LCD fluid, wash immediately with soap.
6) Conduc1tivity is not guaranteed for models that use metal holders where solder connections
between the metal holder and the PCB are not used. Please contact us to discuss appropriate
ways to assure conductivity.
7) For models which use CFL:
① High voltage of 1000V or greater is applied to the CFL cable connector area.
Care should be taken not to touch connection areas to avoid burns.
② Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn.
③The use of CFLs for extended periods of time at low temperatures will significantly shorten their
service life.
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
OPTREX CORPORATION
Page 16/17
8) For models which use touch panels:
①Do not stack up modules since they can be damaged by components on neighboring modules.
②Do not place heavy objects on top of the product. This could cause glass breakage.
9) For models which use COG,TAB,or COF:
①The mechanical strength of the product is low since the IC chip faces out unprotected from the rear.
Be sure to protect the rear of the IC chip from external forces.
②Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical
damage, avoid installation configurations in which the rear of the IC chip runs the risk of making
any electrical contact.
10) Models which use flexible cable, heat seal, or TAB:
①In order to maintain reliability, do not touch or hold by the connector area.
②Avoid any bending, pulling, or other excessive force, which can result in broken connections.
11. Warranty
This product has been manufactured to your company’s specifications as a part for use in your company’s
general electronic products. It is guaranteed to perform according to delivery specifications. For any other
use apart from general electronic equipment, we cannot take responsibility if the product is used in medical
devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other
applications in which there is a direct risk to human life and where extremely high levels of reliability are
required. If the product is to be used in any of the above applications, we will need to enter into a separate
product liability agreement.
① We cannot accept responsibility for any defect, which may arise from additional manufacturing of
the product (including disassembly and reassembly), after product delivery.
② We cannot accept responsibility for any defect, which may arise after the application of strong
external force to the product.
③ We cannot accept responsibility for any defect, which may arise due to the application of static
electricity after the product has passed your company’s acceptance inspection procedures.
④ When the product is in CFL models, CFL service life and brightness will vary according to the
performance of the inverter used, leaks, etc. We cannot accept responsibility for product
performance, reliability, or defect, which may arise.
⑤ We cannot accept responsibility for industrial property, which may arise through the use of your
product, with exception to those issues relating directly to the structure or method of
manufacturing of our product.
⑥ Optrex will not be held responsible for any quality guarantee issue for defect products judged as
Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex
America, Optrex Europe, Display LC delivery which ever comes later.
F-51167NCU-FW-AB
(AB)
No.2000-0182
OPTREX
OPTREX CORPORATION
Page 17/17
Similar pages