XP Power ECP60UD01 60 watts ecp sery Datasheet

ACDC
60 Watts
ECP Series
xppower.com
•
Low Profile Design
•
Compact Size, 4” x 2”
•
IT & Medical Approvals
•
Single, Dual and Triple Output
•
<0.5 W No Load Input Power
•
Peak Load Capability
•
3 Year Warranty
Specification
Input
• 85-264 VAC, derate from 100% load at
90 VAC to 90% load at 85 VAC
Input Frequency
• 47-63 Hz
Input Current
• 0.85 A max at 115 VAC
Inrush Current
• 100 A max at 230 VAC, cold start at 25 °C
Power Factor
• EN61000-3-2, class A
No Load Input Power • <0.5 W
Earth Leakage Current • <250 µA at 264 VAC, 60 Hz
Input Protection
• Internal T2 A/250 V fuse in both
line and neutral
Input Voltage
Output
• See table
• ±10% on V1 only, output 2 on multi output
models will track by the same percentage
Minimum Load
• 10% minimum load required on all
outputs of multi output models
Start Up Delay
• 1.3 s max
Start Up Rise Time
• 15 ms typical
Hold Up Time
• 16 ms min at full load at 115 VAC
Total Regulation
• Output 1: 2% from 0% load to 100% load
Output 2: 5% from 20% load to 100% load
Output 3: 5% from 10% load to 100% load
Remote Sense
• Fitted to US05 version, compensates for
0.5 V drop
Transient Response
• 4% max deviation, recovering to less than
1% within 500 µs for 50% step load
change at 1 A/µs
Ripple & Noise
• 1% pk-pk (2% for US05 version),
measured with 20 MHz bandwidth
Overvoltage Protection • 115-140% of nominal output voltage
on V1 only, recycle input to reset
Overload Protection
• 120-160% of nominal power
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature
• ±0.02%/°C max
Coefficient
Output Voltage
Output Voltage Trim
General
Efficiency
Isolation
Switching Frequency
MTBF
• 88% typical at 230 VAC and full load
• 4000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
• 30-130 kHz variable
• >400 kHrs to MIL-HDBK-217F
at 25 °C, GB
Environmental
Operating Temperature • -20 °C to +70 °C, derate from 100% load
at 50 °C to 50% load at 70 °C
Cooling
• Natural convection
Operating Humidity
• 5% to 95% RH, non condensing
Operating Altitude
• 3000 m max
Storage Temperature • -40 °C to +85 °C
Shock
• 30 g pk, half sine, 6 axes
Vibration
• 2 g rms, 5 Hz to 500 Hz, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT / Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
• EN55011/22, level B conducted & level A
radiated
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-2, ±4 kV indirect contact,
Perf Criteria A
• EN61000-4-3, 3 V/m, Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, installation class 3,
Perf Criteria A
• EN61000-4-6, 3 V Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms,
Perf Criteria A, A, A, B
• EN60950-1, cUL60950-1, IEC60950-1,
EN60601-1, ANSI/AAMI ES60601-1,
CSA22.2 No.60601-1 Including Risk
Management, IEC60601-1
Output 1
Output 2
Output 3
Output
Power
Voltage
Current
Peak(1)
55 W
+5.0 VDC
11.0 A
14.3 A
60 W
+5.0 VDC
7.0 A
9.1 A
+12.0 VDC
3.0 A
3.90 A
ECP60UD01
60 W
+5.0 VDC
7.0 A
9.1 A
+15.0 VDC
2.0 A
2.60 A
ECP60UD02
60 W
+5.0 VDC
7.0 A
9.1 A
+24.0 VDC
1.5 A
1.95 A
60 W
+5.0 VDC
7.0 A
9.1 A
+12.0 VDC
3.0 A
3.90 A
60 W
+5.0 VDC
7.0 A
9.1 A
+15.0 VDC
2.0 A
2.60 A
60 W
+5.0 VDC
7.0 A
9.1 A
+24.0 VDC
1.5 A
1.95 A
60 W
+5.0 VDC
7.0 A
9.1 A
+24.0 VDC
1.5 A
1.95 A
-12.0 V
Voltage
Current
Peak(1)
Voltage
Current
Model Number
ECP60US05
ECP60UD03
-12.0 V
0.30 A
ECP60UT01
-15.0 V
0.30 A
ECP60UT02
+12.0 V
0.30 A
ECP60UT03
0.30 A
ECP60UT04
Notes
1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal.
Mechanical Details
CN1 - Input Connector
Pin 1
Neutral
Pin 2
Not Fitted
Pin 3
Line
4.00 (101.6)
3.75 (95.2)
Voltage Adj.
Mates with JST housing
VHR-3N and JST Series
SVH-21T-P1.1 crimp terminals
6
1
Mounting holes marked with
must be connected to safety earth
CN2 Output Connector
Pin
Pin
Pin
Pin
Pin
Pin
1
2
3
4
5
6
UD/UT
US05
V3
RTN
RTN
V1
V1
V2
RTN
RTN
RTN
+5 V
+5 V
+5 V
1
1
CN1
UD/UT
1
1.75
(44.4)
US05
Mounting holes need to be isolated from ground
1.04
(26.3)
CN3 Sense Connector
CN2
1.75
(44.4)
3
0.13 ±0.01 (3.4 ±0.3)
Mates with JST housing
VHR-6N and JST Series
SVH-21T-P1.1 crimp terminals
Pin 1
Pin 2
CN2
2.00
(50.8)
CN3
6
1.20
(30.4)
-Sense
+Sense
Fitted to ECP60US05 only. Mates
with Molex Housing 22-01-1022
and 2759 crimp terminals
0.1 (2.5)
0.06 (1.6)
Notes
1. All dimensions are in inches (mm).
2. Weight: 0.34 lbs (155 g) approx.
3. Tolerance: ±0.02 (±0.5) unless stated
Derating Curve
Output Power (%)
100
80
60
40
20
0
-20
-10
0
10
20
30
40
50
60
70
80
Ambient Temperature (ºC)
06-Nov-13
ACDC
ECP60
Models and Ratings