ACDC 60 Watts ECP Series xppower.com • Low Profile Design • Compact Size, 4” x 2” • IT & Medical Approvals • Single, Dual and Triple Output • <0.5 W No Load Input Power • Peak Load Capability • 3 Year Warranty Specification Input • 85-264 VAC, derate from 100% load at 90 VAC to 90% load at 85 VAC Input Frequency • 47-63 Hz Input Current • 0.85 A max at 115 VAC Inrush Current • 100 A max at 230 VAC, cold start at 25 °C Power Factor • EN61000-3-2, class A No Load Input Power • <0.5 W Earth Leakage Current • <250 µA at 264 VAC, 60 Hz Input Protection • Internal T2 A/250 V fuse in both line and neutral Input Voltage Output • See table • ±10% on V1 only, output 2 on multi output models will track by the same percentage Minimum Load • 10% minimum load required on all outputs of multi output models Start Up Delay • 1.3 s max Start Up Rise Time • 15 ms typical Hold Up Time • 16 ms min at full load at 115 VAC Total Regulation • Output 1: 2% from 0% load to 100% load Output 2: 5% from 20% load to 100% load Output 3: 5% from 10% load to 100% load Remote Sense • Fitted to US05 version, compensates for 0.5 V drop Transient Response • 4% max deviation, recovering to less than 1% within 500 µs for 50% step load change at 1 A/µs Ripple & Noise • 1% pk-pk (2% for US05 version), measured with 20 MHz bandwidth Overvoltage Protection • 115-140% of nominal output voltage on V1 only, recycle input to reset Overload Protection • 120-160% of nominal power Short Circuit Protection • Trip and restart (hiccup mode) Temperature • ±0.02%/°C max Coefficient Output Voltage Output Voltage Trim General Efficiency Isolation Switching Frequency MTBF • 88% typical at 230 VAC and full load • 4000 VAC Input to Output 1500 VAC Input to Ground 500 VDC Output to Ground • 30-130 kHz variable • >400 kHrs to MIL-HDBK-217F at 25 °C, GB Environmental Operating Temperature • -20 °C to +70 °C, derate from 100% load at 50 °C to 50% load at 70 °C Cooling • Natural convection Operating Humidity • 5% to 95% RH, non condensing Operating Altitude • 3000 m max Storage Temperature • -40 °C to +85 °C Shock • 30 g pk, half sine, 6 axes Vibration • 2 g rms, 5 Hz to 500 Hz, 3 axes EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT / Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals • EN55011/22, level B conducted & level A radiated • EN61000-3-2, class A • EN61000-3-3 • EN61000-4-2, ±4 kV indirect contact, Perf Criteria A • EN61000-4-3, 3 V/m, Perf Criteria A • EN61000-4-4, level 3 Perf Criteria A • EN61000-4-5, installation class 3, Perf Criteria A • EN61000-4-6, 3 V Perf Criteria A • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A, A, B • EN60950-1, cUL60950-1, IEC60950-1, EN60601-1, ANSI/AAMI ES60601-1, CSA22.2 No.60601-1 Including Risk Management, IEC60601-1 Output 1 Output 2 Output 3 Output Power Voltage Current Peak(1) 55 W +5.0 VDC 11.0 A 14.3 A 60 W +5.0 VDC 7.0 A 9.1 A +12.0 VDC 3.0 A 3.90 A ECP60UD01 60 W +5.0 VDC 7.0 A 9.1 A +15.0 VDC 2.0 A 2.60 A ECP60UD02 60 W +5.0 VDC 7.0 A 9.1 A +24.0 VDC 1.5 A 1.95 A 60 W +5.0 VDC 7.0 A 9.1 A +12.0 VDC 3.0 A 3.90 A 60 W +5.0 VDC 7.0 A 9.1 A +15.0 VDC 2.0 A 2.60 A 60 W +5.0 VDC 7.0 A 9.1 A +24.0 VDC 1.5 A 1.95 A 60 W +5.0 VDC 7.0 A 9.1 A +24.0 VDC 1.5 A 1.95 A -12.0 V Voltage Current Peak(1) Voltage Current Model Number ECP60US05 ECP60UD03 -12.0 V 0.30 A ECP60UT01 -15.0 V 0.30 A ECP60UT02 +12.0 V 0.30 A ECP60UT03 0.30 A ECP60UT04 Notes 1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal. Mechanical Details CN1 - Input Connector Pin 1 Neutral Pin 2 Not Fitted Pin 3 Line 4.00 (101.6) 3.75 (95.2) Voltage Adj. Mates with JST housing VHR-3N and JST Series SVH-21T-P1.1 crimp terminals 6 1 Mounting holes marked with must be connected to safety earth CN2 Output Connector Pin Pin Pin Pin Pin Pin 1 2 3 4 5 6 UD/UT US05 V3 RTN RTN V1 V1 V2 RTN RTN RTN +5 V +5 V +5 V 1 1 CN1 UD/UT 1 1.75 (44.4) US05 Mounting holes need to be isolated from ground 1.04 (26.3) CN3 Sense Connector CN2 1.75 (44.4) 3 0.13 ±0.01 (3.4 ±0.3) Mates with JST housing VHR-6N and JST Series SVH-21T-P1.1 crimp terminals Pin 1 Pin 2 CN2 2.00 (50.8) CN3 6 1.20 (30.4) -Sense +Sense Fitted to ECP60US05 only. Mates with Molex Housing 22-01-1022 and 2759 crimp terminals 0.1 (2.5) 0.06 (1.6) Notes 1. All dimensions are in inches (mm). 2. Weight: 0.34 lbs (155 g) approx. 3. Tolerance: ±0.02 (±0.5) unless stated Derating Curve Output Power (%) 100 80 60 40 20 0 -20 -10 0 10 20 30 40 50 60 70 80 Ambient Temperature (ºC) 06-Nov-13 ACDC ECP60 Models and Ratings