Click on Series name for product info on aimtec.com Series AM40U-IZ 40Watt | DC-DC Converter FEATURES: • • • • • Models Single output Model AM40U-1203SIZ AM40U-1205SIZ AM40U-1212SIZ AM40U-1215SIZ AM40U-1224SIZ AM40U-2403SIZ AM40U-2405SIZ AM40U-2412SIZ AM40U-2415SIZ AM40U-2424SIZ AM40U-4803SIZ AM40U-4805SIZ AM40U-4812SIZ AM40U-4815SIZ AM40U-4824SIZ AM40U-1203SH30IZ AM40U-1205SH30IZ AM40U-1212SH30IZ AM40U-1215SH30IZ AM40U-1224SH30IZ AM40U-2403SH30IZ AM40U-2405SH30IZ AM40U-2412SH30IZ AM40U-2415SH30IZ AM40U-2424SH30IZ AM40U-4803SH30IZ AM40U-4805SH30IZ AM40U-4812SH30IZ AM40U-4815SH30IZ AM40U-4824SH30IZ Models Dual output Model AM40U-1205DIZ AM40U-1212DIZ AM40U-1215DIZ AM40U-2405DIZ AM40U-2412DIZ AM40U-2415DIZ AM40U-4805DIZ AM40U-4812DIZ AM40U-4815DIZ www.aimtec.com F 051e R12.B Wide Input 2:1 Range 1500 & 3000 VDC Isolation Efficiency up to 87% Regulated Output Soft Start • • • • Adjustable Output Voltage Remote ON/OFF Function Over Load, Voltage & Short Circuit Protection Operating temperature -40oC to + 75oC Input Voltage (V) Output Voltage (V) Output Current max (A) Isolation (VDC) Efficiency (%) 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 36-75 3.3 5 12 15 24 3.3 5 12 15 24 3.3 5 12 15 24 7 7 3 2.3 1.5 7 7 3 2.3 1.5 7 7 3 2.3 1.5 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 85 85 85 85 85 86 86 86 86 86 86 86 87 87 87 Input Voltage (V) Output Voltage (V) Output Current max (A) Isolation (VDC) Efficiency (%) 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 36-75 9-18 9-18 9-18 18-36 18-36 18-36 36-75 36-75 36-75 3.3 5 12 15 24 3.3 5 12 15 24 3.3 5 12 15 24 ±5 ±12 ±15 ±5 ±12 ±15 ±5 ±12 ±15 7 7 3 2.3 1.5 7 7 3 2.3 1.5 7 7 3 2.3 1.5 ±3.5 ±1.5 ±1.15 ±3.5 ±1.5 ±1.15 ±3.5 ±1.5 ±1.15 Tel: +1 514 620 2722 1 of 5 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 85 85 85 85 85 86 86 86 86 86 86 86 87 87 87 83 83 83 80 80 80 81 81 81 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40U-IZ 40Watt | DC-DC Converter Models Dual output (continued) Model Input Voltage (V) Output Voltage (V) Output Current max (A) Isolation (VDC) Efficiency (%) AM40U-1205DH30IZ 9-18 ±5 ±3.5 3000 83 AM40U-1212DH30IZ 9-18 ±12 ±1.5 3000 83 AM40U-1215DH30IZ 9-18 ±15 ±1.15 3000 83 AM40U-2405DH30IZ 18-36 ±5 ±3.5 3000 80 AM40U-2412DH30IZ 18-36 ±12 ±1.5 3000 80 AM40U-2415DH30IZ 18-36 ±15 ±1.15 3000 80 AM40U-4805DH30IZ 36-75 ±5 ±3.5 3000 81 AM40U-4812DH30IZ 36-75 ±12 ±1.5 3000 81 AM40U-4815DH30IZ 36-75 ±15 ±1.15 3000 81 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Filter Absolute Maximum Rating On/Off control Isolation Specifications Parameters Tested I/O voltage Resistance Nominal Parameters Ripple & Noise Voltage adjustment range Minimum Load Current General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Derating Cooling Humidity www.aimtec.com F 051e R12.B 9-18 18-36 36-75 π(Pi) Network 12 24 48 Maximum Units VDC 25 50 100 ON –TTL High or Open ; OFF – TTL Low or short Conditions Typical 3 sec 500VDC Output Specifications Voltage accuracy Over voltage protection Over current protection Short Circuit protection Short circuit restart Line voltage regulation Load voltage regulation (Single) Load voltage regulation (Dual) Temperature coefficient Typical 12 24 48 1500 or 3000 >1000 Conditions Maximum Typical Conditions 100% load See chart below Typical 2 of 5 VDC MOhm Units % % % of Vin % % %/oC mV p-p % p-p Vout % % of Max Maximum Units 95 % RH 250 -40 to +75 -55 to +115 100 45 Free air convection Tel: +1 514 620 2722 Units Maximum ±2 Zener diode clamp >110 FL Continuous Auto-Restart ±0.5 Iout=25% to 100% ±0.5 Iout=25% to 100% ±2 ±0.05 20MHz Bandwidth (5 & 3.3Vout) 80 All other output models 1 ±5 25 VDC KHz o C o C o C o C Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40U-IZ 40Watt | DC-DC Converter General Specifications (continued) Parameters Conditions Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Transient recovery time Maximum 50% load step change Safety & EMC Specifications Agency approvals Typical Nickel – coated Copper with nonconductive base 65 2.00 x 2.00 x 0.40 inches 50.81 x 50.81 10.20 mm >1 500 000 hrs ( MIL-HDBK-217 F at +25 oC) 280 g o C uS Parameters CE, (on 1500 VDC Isolation models only) EN55022: 2010, class A EN55024: 2010 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-6 IEC 61000-4-8 EMI - Conducted and radiated emission Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Standards Units Pin Out Specifications Pin 1000 & 3000VDC Single +V Input -V Input On/Off Control No pin +V Output -V Output Trim 1 2 3 4 5 6 7 Dual +V Input -V Input On/Off Control +V Output Common -V Output Trim Dimensions 10.16 (0.40) Bottom View 5 2 6 3 7 10.16 (0.40) 50.80 (2.00) 5.08 (0.20) 1 10.16 (0.40) 22.86 (0.90) 4 10.16 (0.40) 50.80 (2.00) 45.70 (1.80) Printed Face Dimensions mm (inch) Case Tolerance: ±0.25mm (±0.02inch) Pin Length Tolerence: ±0.05mm (±0.002inch) 5.60 (0.22) Side View 1.00 (0.04) www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40U-IZ 40Watt | DC-DC Converter Trimming Derating Free Air Convection 45 º C Output Power (%) 100 80 Safe Operating Area 60 40 35 20 75 0 - 40 - 20 0 20 40 60 80 100 Ambient Temperature º C Control ON/OFF pin connection example Single Output www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40U-IZ 40Watt | DC-DC Converter Dual Output Digital Control Circuit: Vpeak Control Voltage On / Off Control 0.5mA NPN 0V Ra = Vpeak – 0.6 DC/DC Converter -V input 0.5mA NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.B Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only