Vitec ILPA100JU-SERIES 100w water-proof constant current led driver Datasheet

ILPA100JU SERIES
100W Water-Proof Constant Current LED Driver
–
–
–
–
–
–
–
2 Year Warranty
Wide Input Voltage 90 to 305VAC, 47 to 63Hz
Constant Output Current Available From 350mA To 4200mA
Over Voltage, Short Circuit, Lighting, and Over Temperature Protection
High Efficiency (up to 92%)
Active Power Factor Correction (PFC) (99% typical)
IP67 Waterproof Rating, Metal Housing
Comply with UL8750 & EN61347 Safety Regulation
Approvals:
Single Output
Part Number
ILPA100JU-S420ST
ILPA100JU-S357ST
ILPA100JU-S315ST
ILPA100JU-S280ST
ILPA100JU-S245ST
ILPA100JU-S210ST
ILPA100JU-S175ST
ILPA100JU-S140ST
ILPA100JU-S105ST
ILPA100JU-S070ST
ILPA100JU-S045ST
ILPA100JU-S035ST
Output Current Range
(Min. / Typ. / Max.)
3990 / 4200 / 4410 mA
3391 / 3570 / 3748 mA
2992 / 3150 / 3307 mA
2660 / 2800 / 2940 mA
2327 / 2450 / 2572 mA
1995 / 2100 / 2205 mA
1662 / 1750 / 1837 mA
1330 / 1400 / 1470 mA
997 / 1050 / 1102 mA
665 / 700 / 735 mA
427 / 450 / 473 mA
332 / 350 / 368 mA
Output Voltage
(Min. / Max.)
14 / 24 VDC
17 / 28 VDC
19 / 32 VDC
22 / 36 VDC
25 / 41 VDC
29 / 48 VDC
34 / 57 VDC
43 / 71 VDC
57 / 95 VDC
86 / 143 VDC
132 / 222 VDC
172 / 286 VDC
Efficiency
(220VAC, Full Load)
90.5%
90.5%
90.5%
90.5%
91%
91%
91%
91%
91%
91%
92%
92%
Over Voltage Protection
(Min. / Typ. / Max.)
28 / 31 / 34 VDC
33 / 36 / 40 VDC
38 / 42 / 45 VDC
43 / 47 / 51 VDC
49 / 53 / 58 VDC
57 / 63 / 67 VDC
68 / 74 / 80 VDC
86 / 94 / 101 VDC
114 / 124 / 133 VDC
171 / 186 / 200 VDC
266 / 289 / 311 VDC
343 / 372 / 401 VDC
Max.
Output Power
100W
100W
100W
100W
100W
100W
100W
100W
100W
100W
100W
100W
Electrical Characteristics
Parameter
Input Voltage
Input Frequency
Output Power Range
Input Current (Low Line)
Input Current (High Line)
High Line Inrush Current
Power Factor Correction
Efficiency
Line Regulation
Load Regulation
Over Voltage Protection
Over Temperature Protection
Short Circuit Protection
Output Overshoot / Undershoot
Start Up Time
Ripple & Noise (Peak to Peak)
Test Conditions
Operating Voltage
Max.
Unit
305
VAC
63
Hz
Vin=90 to 305VAC
100
W
Io=Full load, Vin=115VAC
1.30
A
Io=Full load, Vin=230VAC
0.60
A
Io=Full load, 25°C, Cool start, Vin=230VAC
65
A
Vin=110VAC
96
99
%
Io=Full Load, Vin=220VAC
88
92
%
Io=Full Load
1
%
Vin=230VAC
5
%
Latch mode. The power unit shall return to normal operation only after the power is turn-on again.
(Please refer to output table.)
110
°C
No damage shall occur when any output operating in a short circuit condition. The power supply shall be
self-recovery when the fault condition is removed.
When power on or off
10
%
Io=Full Load, Vin=100VAC
0.6
1
S
Measured by 20 MHz bandwidth oscilloscope and the
output paralleled a 0.1 uF ceramic capacitor and a 10
uF electrolytic capacitor.
Min.
90
47
0
Typ.
5
% Vo
Conditions
Parameter
Test Conditions
Min.
Operating Temperature
Humidity: 10% RH to 100% RH
Storage Temperature
Humidity: 5% RH to 100% RH
MTBF: Operation temperature at 25°C, calculated per MIL-HDBK-217F
Life Time at 25°C ambient temperature
-35
-40
0.478M
0.104M
Typ.
Max.
Unit
70
85
°C
°C
Hours
Hours
Approvals and Compliance
Parameter
EMI
EMS
Safety UL/c-UL, CE
Waterproof
Standards
EN55015
EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, , EN61000-4-4, , EN61000-4-5, EN61000-4-6,
EN61000-4-8, EN61000-4-11, EN61547
UL8750 Compliant to UL1310 ClaST 2, UL1012, UL935, CSA-C22.2 No. 0, CSA-C22.2 No. 107.1,
CSA-C22.2 No.250.0, EN61347-1,EN61347-2-13
IP67 Rating
Mechanical
Parameter
Specification
Dimension,
194x67.5x37mm (7.64x2.66x1.46 inches)
Net Weight
1000g approx.
Similar pages