Microchip HCS500-I/SM Keeloq code hopping decoder Datasheet

HCS500
KEELOQ® Code Hopping Decoder
FEATURES
DESCRIPTION
Security
The Microchip Technology Inc. HCS500 is a code hopping decoder designed for secure Remote Keyless
Entry (RKE) systems. The HCS500 utilizes the patented KEELOQ code hopping system and high security
learning mechanisms to make this a canned solution
when used with the HCS encoders to implement a unidirectional remote and access control systems. The
HCS500 can be used as a stand-alone decoder or in
conjunction with a microcontroller.
•
•
•
•
•
Encrypted storage of manufacturer’s code
Encrypted storage of crypt keys
Up to seven transmitters can be learned
KEELOQ code hopping technology
Normal and Secure learning mechanisms
Operating
• 3.0V—5.5V operation
• Internal oscillator
• Auto bit rate detection
•
•
•
•
•
Stand-alone decoder chipset
External EEPROM for transmitter storage
Synchronous serial interface
1 Kbit user EEPROM
8-pin DIP/SOIC package
PDIP, SOIC
VDD
1
EE_CLK
2
EE_DAT
3
MCLR
4
HCS500
Other
PACKAGE TYPE
8
VSS
7
RFIN
6
S_CLK
5
S_DAT
BLOCK DIAGRAM
Typical Applications
•
•
•
•
•
•
•
Automotive remote entry systems
Automotive alarm systems
Automotive immobilizers
Gate and garage openers
Electronic door locks
Identity tokens
Burglar alarm systems
RFIN
Reception Register
DECRYPTOR
EE_DAT
External
EEPROM
CONTROL
EE_CLK
OSCILLATOR
S_DAT
S_CLK
MCLR
Compatible Encoders
All KEELOQ encoders and transponders configured for
the following setting:
•
•
•
•
•
•
•
PWM modulation format (1/3-2/3)
TE in the range from 100us to 400us
10 x TE Header
28-bit Serial Number
16-bit Synchronization counter
Discrimination bits equal to Serial Number 8 LSbs
66- to 69-bit length code word.
 2002 Microchip Technology Inc.
The manufacturer’s code, crypt keys, and synchronization information are stored in encrypted form in external
EEPROM. The HCS500 uses the S_DAT and S_CLK
inputs to communicate with a host controller device.
The HCS500 operates over a wide voltage range of
3.0 volts to 5.5 volts. The decoder employs automatic
bit-rate detection, which allows it to compensate for
wide variations in transmitter data rate. The decoder
contains sophisticated error checking algorithms to
ensure only valid codes are accepted.
DS40153C-page 1
HCS500
1.0
SYSTEM OVERVIEW
Key Terms
The following is a list of key terms used throughout this
data sheet. For additional information on KEELOQ and
Code Hopping, refer to Technical Brief 3 (TB003).
• RKE - Remote Keyless Entry
• Button Status - Indicates what button input(s)
activated the transmission. Encompasses the 4
button status bits S3, S2, S1 and S0 (Figure 7-2).
• Code Hopping - A method by which a code,
viewed externally to the system, appears to
change unpredictably each time it is transmitted.
• Code word - A block of data that is repeatedly
transmitted upon button activation (Figure 7-1).
• Transmission - A data stream consisting of
repeating code words (Figure 7-1).
• Crypt key - A unique and secret 64-bit number
used to encrypt and decrypt data. In a symmetrical block cipher such as the KEELOQ algorithm,
the encryption and decryption keys are equal and
will therefore be referred to generally as the crypt
key.
• Encoder - A device that generates and encodes
data.
• Encryption Algorithm - A recipe whereby data is
scrambled using a crypt key. The data can only be
interpreted by the respective decryption algorithm
using the same crypt key.
• Decoder - A device that decodes data received
from an encoder.
• Decryption algorithm - A recipe whereby data
scrambled by an encryption algorithm can be
unscrambled using the same crypt key.
• Learn – Learning involves the receiver calculating
the transmitter’s appropriate crypt key, decrypting
the received hopping code and storing the serial
number, synchronization counter value and crypt
key in EEPROM. The KEELOQ product family facilitates several learning strategies to be implemented on the decoder. The following are
examples of what can be done.
- Simple Learning
The receiver uses a fixed crypt key, common
to all components of all systems by the same
manufacturer, to decrypt the received code
word’s encrypted portion.
- Normal Learning
The receiver uses information transmitted
during normal operation to derive the crypt
key and decrypt the received code word’s
encrypted portion.
- Secure Learn
The transmitter is activated through a special
button combination to transmit a stored 60-bit
seed value used to generate the transmitter’s
crypt key. The receiver uses this seed value
DS40153C-page 2
to derive the same crypt key and decrypt the
received code word’s encrypted portion.
• Manufacturer’s code – A unique and secret 64bit number used to generate unique encoder crypt
keys. Each encoder is programmed with a crypt
key that is a function of the manufacturer’s code.
Each decoder is programmed with the manufacturer code itself.
1.1
HCS Encoder Overview
The HCS encoders have a small EEPROM array which
must be loaded with several parameters before use.
The most important of these values are:
• A crypt key that is generated at the time of production
• A 16-bit synchronization counter value
• A 28-bit serial number which is meant to be
unique for every encoder
The manufacturer programs the serial number for each
encoder at the time of production, while the ‘Key Generation Algorithm’ generates the crypt key (Figure 1-1).
Inputs to the key generation algorithm typically consist
of the encoder’s serial number and a 64-bit manufacturer’s code, which the manufacturer creates.
Note:
The manufacturer code is a pivotal part of
the system’s overall security. Consequently, all possible precautions must be
taken and maintained for this code.
 2002 Microchip Technology Inc.
HCS500
FIGURE 1-1:
CREATION AND STORAGE OF CRYPT KEY DURING PRODUCTION
Production
Programmer
HCS500
Transmitter
Serial Number
EEPROM Array
Serial Number
Crypt Key
Sync Counter
Manufacturer’s
Code
Key
Generation
Algorithm
The 16-bit synchronization counter is the basis behind
the transmitted code word changing for each transmission; it increments each time a button is pressed. Due
to the code hopping algorithm’s complexity, each increment of the synchronization value results in greater
than 50% of the bits changing in the transmitted code
word.
Figure 1-2 shows how the key values in EEPROM are
used in the encoder. Once the encoder detects a button
press, it reads the button inputs and updates the synchronization counter. The synchronization counter and
crypt key are input to the encryption algorithm and the
output is 32 bits of encrypted information. This data will
change with every button press, its value appearing
externally to ‘randomly hop around’, hence it is referred
to as the hopping portion of the code word. The 32-bit
hopping code is combined with the button information
and serial number to form the code word transmitted to
the receiver. The code word format is explained in
greater detail in Section 7.2.
FIGURE 1-2:
.
.
.
Crypt
Key
A receiver may use any type of controller as a decoder,
but it is typically a microcontroller with compatible firmware that allows the decoder to operate in conjunction
with an HCS500 based transmitter. Section 3.0
provides detail on integrating the HCS500 into a system.
A transmitter must first be ‘learned’ by the receiver
before its use is allowed in the system. Learning
includes calculating the transmitter’s appropriate crypt
key, decrypting the received hopping code and storing
the serial number, synchronization counter value and
crypt key in EEPROM.
In normal operation, each received message of valid
format is evaluated. The serial number is used to determine if it is from a learned transmitter. If from a learned
transmitter, the message is decrypted and the synchronization counter is verified. Finally, the button status is
checked to see what operation is requested. Figure 1-3
shows the relationship between some of the values
stored by the receiver and the values received from
the transmitter.
BUILDING THE TRANSMITTED CODE WORD (ENCODER)
EEPROM Array
Crypt Key
Sync Counter
KEELOQ
Encryption
Algorithm
Serial Number
Button Press
Information
Serial Number
32 Bits
Encrypted Data
Transmitted Information
 2002 Microchip Technology Inc.
DS40153C-page 3
HCS500
FIGURE 1-3:
BASIC OPERATION OF RECEIVER (DECODER)
1 Received Information
EEPROM Array
Button Press
Information
Serial Number
2
32 Bits of
Encrypted Data
Manufacturer Code
Check for
Match
Serial Number
Sync Counter
Crypt Key
3
KEELOQ
Decryption
Algorithm
Decrypted
Synchronization
Counter
4
Check for
Match
Perform Function
5 Indicated by
button press
Note: Circled numbers indicate the order of execution.
2.0
PIN
PIN ASSIGNMENT
Decoder
Function
I/O(1)
Buffer
Type(1)
Description
1
VDD
P
—
2
EE_CLK
O
TTL
Clock to I 2C™ EEPROM
Power Connection
3
EE_DAT
I/O
TTL
Data to I 2C EEPROM
4
MCLR
I
ST
Master clear input
5
S_DAT
I/O
TTL
Synchronous data from controller
6
S_CLK
I
TTL
Synchronous clock from controller
7
RFIN
I
TTL
8
GND
P
—
RF input from receiver
Ground connection
Note: P = power, I = in, O = out, and ST = Schmitt Trigger input.
DS40153C-page 4
 2002 Microchip Technology Inc.
HCS500
3.0
DECODER OPERATION
3.1
Learning a Transmitter to a
Receiver (Normal or Secure Learn)
Before the transmitter and receiver can work together,
the receiver must first ‘learn’ and store the following
information from the transmitter in EEPROM:
• A check value of the serial number
• The crypt key
• The current synchronization counter value
The decoder must also store the manufacturer’s code
(Section 1.1) in protected memory. This code will
typically be the same for all of the decoders in a system.
The HCS500 has seven memory slots, and, consequently, can store up to seven transmitters. During the
learn procedure, the decoder searches for an empty
memory slot for storing the transmitter’s information.
When all of the memory slots are full, the decoder will
overwrite the last transmitter’s information. To erase all
of the memory slots at once, use the ERASE_ALL command (C3H).
3.2
LEARNING PROCEDURE
Learning is initiated by sending the ACTIVATE_LEARN
(D2H) command to the decoder. The decoder acknowledges reception of the command by pulling the data
line high.
For the HCS500 decoder to learn a new transmitter, the
following sequence is required:
1.
2.
3.
4.
Activate the transmitter once.
Activate the transmitter a second time. (In
Secure Learning mode, the seed transmission
must be transmitted during the second stage of
learn by activating the appropriate buttons on
the transmitter.)
The HCS500 will transmit a learn-status string,
indicating that the learn was successful.
The decoder has now learned the transmitter.
Repeat steps 1-3 to learn up to seven
transmitters
Note 1: Learning will be terminated if two
nonsequential codes were received or if
two acceptable codes were not decoded
within 30 seconds.
2: If more than seven transmitters are
learned, the new transmitter will replace
the last transmitter learned. It is, therefore,
not possible to erase lost transmitters by
repeatedly learning new transmitters. To
remove lost or stolen transmitters,
ERASE_ALL transmitters and relearn all
available transmitters.
 2002 Microchip Technology Inc.
3: Learning a transmitter with a crypt key that
is identical to a transmitter already in memory replaces the existing transmitter. In
practice, this means that all transmitters
should have unique crypt keys. Learning a
previously learned transmitter does not use
any additional memory slots.
The following checks are performed by the decoder to
determine if the transmission is valid during learn:
• The first code word is checked for bit integrity.
• The second code word is checked for bit integrity.
• The crypt key is generated according to the
selected algorithm.
• The hopping code is decrypted.
• The discrimination value is checked.
• If all the checks pass, the key, serial number
check value, and synchronization counter values
are stored in EEPROM memory.
Figure 3-1 shows a flow chart of the learn sequence.
FIGURE 3-1:
LEARN SEQUENCE
Enter Learn
Mode
Wait for Reception
of a Valid Code
Wait for Reception
of Second
Non-Repeated
Valid Code
Generate Key
from Serial Number/
Seed Value
Use Generated Key
to Decrypt
Compare Discrimination
Value with Serial Number
Equal?
No
Yes
Learn successful. Store:
Learn
Unsuccessful
Serial number check value
crypt key
Sync. counter value
Exit
DS40153C-page 5
HCS500
3.3
Validation of Codes
The decoder waits for a transmission and checks the
serial number to determine if it is a learned transmitter.
If it is, it takes the code hopping portion of the transmission and decrypts it, using the crypt key. It uses the discrimination value to determine if the decryption was
valid. If everything up to this point is valid, the
synchronization counter value is evaluated.
3.4
Validation Steps
FIGURE 3-2:
Start
No Transmission
Received?
Yes
No
Validation consists of the following steps:
1.
2.
3.
4.
5.
6.
Search EEPROM to find the Serial Number
Check Value Match
Decrypt the Hopping Code
Compare the 10 bits of the discrimination value
with the lower 10 bits of serial number
Check if the synchronization counter value falls
within the first synchronization window.
Check if the synchronization counter value falls
within the second synchronization window.
If a valid transmission is found, update the
synchronization counter, else use the next
transmitter block, and repeat the tests.
DECODER OPERATION
Does
Ser # Check Val
Match?
Yes
Decrypt Transmission
No
Is
decryption
valid?
Yes
Is
Yes
counter within
16?
Execute
Command
and
Update
Counter
No
Is
No counter
within
16K?
Yes
Save Counter
in Temp Location
DS40153C-page 6
 2002 Microchip Technology Inc.
HCS500
3.5
Synchronization with Decoder
(Evaluating the Counter)
The KEELOQ technology patent scope includes a
sophisticated synchronization technique that does not
require the calculation and storage of future codes. The
technique securely blocks invalid transmissions while
providing transparent resynchronization to transmitters
inadvertently activated away from the receiver.
Figure 3-3 shows a 3-partition, rotating synchronization
window. The size of each window is optional but the
technique is fundamental. Each time a transmission is
authenticated, the intended function is executed and
the transmission’s synchronization counter value is
stored in EEPROM. From the currently stored counter
value there is an initial "Single Operation" forward window of 16 codes. If the difference between a received
synchronization counter and the last stored counter is
within 16, the intended function will be executed on the
single button press and the new synchronization
counter will be stored. Storing the new synchronization
counter value effectively rotates the entire synchronization window.
FIGURE 3-3:
A "Double Operation" (resynchronization) window further exists from the Single Operation window up to 32K
codes forward of the currently stored counter value. It
is referred to as "Double Operation" because a transmission with synchronization counter value in this window will require an additional, sequential counter
transmission prior to executing the intended function.
Upon receiving the sequential transmission the
decoder executes the intended function and stores the
synchronization counter value. This resynchronization
occurs transparently to the user as it is human nature
to press the button a second time if the first was unsuccessful.
The third window is a "Blocked Window" ranging from
the double operation window to the currently stored
synchronization counter value. Any transmission with
synchronization counter value within this window will
be ignored. This window excludes previously used,
perhaps code-grabbed transmissions from accessing
the system.
SYNCHRONIZATION WINDOW
Entire Window
rotates to eliminate
use of previously
used codes
Blocked
Window
(32K Codes)
Stored
Synchronization
Counter Value
Double Operation
(resynchronization)
Window
(32K Codes)
 2002 Microchip Technology Inc.
Single Operation
Window
(16 Codes)
DS40153C-page 7
HCS500
4.0
INTERFACING TO A
MICROCONTROLLER
edge by taking the clock line high. The decoder then
takes the data line low. The microcontroller can then
begin clocking a data stream out of the HCS500. The
data stream consists of:
The HCS500 interfaces to a microcontroller via a synchronous serial interface. A clock and data line are
used to communicate with the HCS500. The microcontroller controls the clock line. There are two groups of
data transfer messages. The first is from the decoder
whenever the decoder receives a valid transmission.
The decoder signals reception of a valid code by taking
the data line high (maximum of 500 ms) The microcontroller then services the request by clocking out a data
string from the decoder. The data string contains the
function code, the status bit, and block indicators. The
second is from the controlling microcontroller to the
decoder in the form of a defined command set.
•
•
•
•
•
START bit ‘0’.
2 status bits [REPEAT, VLOW].
4-bit function code [S3 S2 S1 S0].
STOP bit ‘1’.
4 bits indicating which block was used
[TX3…TX0].
• 4 bits indicating the number of transmitters
learned into the decoder [CNT3…CNT0].
• 64 bits of the received transmission with the hopping code decrypted.
Note:
Figure 4-1 shows the HCS500 decoder and the I/O
interface lines necessary to interface to a microcontroller.
4.1
The decoder will terminate the transmission of the data
stream at any point where the clock is kept low for
longer than 1 ms. Therefore, the microcontroller can
only clock out the required bits. A maximum of 80 bits
can be clocked out of the decoder.
Valid Transmission Message
The decoder informs the microcontroller of a valid
transmission by taking the data line high for up to
500 ms. The controlling microcontroller must acknowl-
FIGURE 4-1:
Data is always clocked in/out Least
Significant Bit (LSB) first.
HCS500 DECODER AND I/O INTERFACE LINES
VDD
RF RECEIVER
1K
1
2
3
4
A0
Vcc
A1
WP
A2
SCL
Vss
SD
8
1
7
2
6
3
5
4
VDD
EE_CLK
RFIN
EE_DAT
S_CLK
MCLR
S_DAT
8
SYNC CLOCK
7
6
SYNC DATA
5
MICRO RESET
HCS500
24LC02
FIGURE 4-2:
Vss
DECODER VALID TRANSMISSION MESSAGE
TPP1
TPP3
TCLKL
TCLKH
TDS
S_CLK
TCLA
TCLKH
TDHI
0
S_DAT
Decoder Signal Valid
Transmission
A
DS40153C-page 8
REPT VLOW S0
S1
S2
S3
1
CNT0
CNT3 TX0
TX3
RX0
Information
B
RX1
RX62 RX63
Received String
Ci
Cii
 2002 Microchip Technology Inc.
HCS500
4.2
4.2.2
Command Mode
4.2.1
The HCS500 uses collision detection to prevent
clashes between the decoder and microcontroller.
Whenever the decoder receives a valid transmission
the following sequence is followed:
MICROCONTROLLER COMMAND
MODE ACTIVATION
The microcontroller command consists of four parts.
The first part activates the Command mode, the second part is the actual command, the third is the address
accessed, and the last part is the data. The microcontroller starts the command by taking the clock line high
for up to 500 ms. The decoder acknowledges the startup sequence by taking the data line high. The microcontroller takes the clock line low, after which the
decoder will take the data line low, tri-state the data line
and wait for the command to be clock in. The data must
be set up on the rising edge and will be sampled on the
falling edge of the clock line.
FIGURE 4-3:
COLLISION DETECTION
• The decoder first checks to see if the clock line is
high. If the clock line is high, the valid transmission notification is aborted, and the microcontroller Command mode request is serviced.
• The decoder takes the data line high and checks
that the clock line doesn’t go high within 50 µs. If
the clock line goes high, the valid transmission
notification is aborted and the Command mode
request is serviced.
• If the clock line goes high after 50 µs but before
500 ms, the decoder will acknowledge by taking
the data line low.
• The microcontroller can then start to clock out the
80-bit data stream of the received transmission.
MICROCONTROLLER COMMAND MODE ACTIVATION
TCLKL
TREQ
TSTART
TADDR
TCMD
TCLKH
TDATA
TDS
CLK
µC Data
LSB
MSB
LSB
MSB
LSB
MSB
TACK
TRESP
Decoder
Data
Start Command
A
Command Byte
B
 2002 Microchip Technology Inc.
Address Byte
C
Data Byte
D
E
DS40153C-page 9
HCS500
4.2.3
COMMAND ACTIVATION TIMES
The command activation time (Table 4-1) is defined as
the maximum time the microcontroller has to wait for a
response from the decoder. The decoder will abort and
service the command request. The response time
depends on the state of the decoder when the Command mode is requested.
TABLE 4-1:
4.2.4
DECODER COMMANDS
The command byte specifies the operation required by
the controlling microcontroller. Table 4-2 lists the commands.
COMMAND ACTIVATION TIMES
Decoder State
Min
Max
While receiving transmissions
—
2.5 ms BPWMAX = 2.7 ms
During the validation of a received transmission
—
3 ms
During the update of the sync counters
—
40 ms
During learn
—
170 ms
*
These parameters are characterized but not tested.
TABLE 4-2:
DECODER COMMANDS
Instruction
Command Byte
Operation
READ
F016
Read a byte from user EEPROM
WRITE
E116
Write a byte to user EEPROM
ACTIVATE_LRN
D216
Activate a learn sequence on the decoder
ERASE_ALL
C316
Activate an erase all function on the decoder
PROGRAM
B416
Program manufacturer’s code and configuration byte
DS40153C-page 10
 2002 Microchip Technology Inc.
HCS500
4.2.5
READ BYTE/S FROM USER
EEPROM
4.2.6
The write command (Figure 4-5) is used to write a location in the user EEPROM. The address byte is truncated to seven bits (C to D). The data is clocked in
Least Significant bit first. The clock line must be
asserted to initiate the write. Sequential writes of bytes
are possible by clocking in the byte and then asserting
the clock line (D – F). The decoder will terminate the
write command if no clock pulses are received for a
period longer than 1.2 ms After a successful write
sequence the decoder will acknowledge by taking the
data line high and keeping it high until the clock line
goes low.
The read command (Figure 4-4) is used to read bytes
from the user EEPROM. The offset in the user
EEPROM is specified by the address byte which is
truncated to seven bits (C to D). After the address, a
dummy byte must be clocked in (D to E). The EEPROM
data byte is clocked out on the next rising edge of the
clock line with the Least Significant bit first (E to F).
Sequential reads are possible by repeating sequence E
to F within 1 ms after the falling edge of the previous
byte’s Most Significant Bit (MSB) bit. During the
sequential read, the address value will wrap after 128
bytes. The decoder will terminate the read command if
no clock pulses are received for a period longer than
1.2 ms.
FIGURE 4-4:
WRITE BYTE/S TO USER EEPROM
READ BYTES FROM USER EEPROM
TRD
TRD
CLK
µC DATA
LSB
MSB
LSB
MSB
LSB
MSB
MSB
LSB
Decoder
DATA
Start Command
A
FIGURE 4-5:
Address Byte
Command Byte
B
Dummy Byte
C
Data Byte
D
F
E
WRITE BYTES TO USER EEPROM
TACK
TWR
TRESP
CLK
µC DATA
LSB
MSB
LSB
MSB
LSB
MSB
TACK2
Decoder
DATA
Start Command
A
Address Byte
Command Byte
B
 2002 Microchip Technology Inc.
C
Data Byte
D
Acknowledge
E
F
DS40153C-page 11
HCS500
4.2.7
ACTIVATE LEARN
Upon reception of the second transmission, the
decoder will respond with a learn status message
(Figure 4-8).
The activate learn command (Figure 4-6) is used to
activate a transmitter learning sequence on the
decoder. The command consists of a Command mode
activation sequence, a command byte, and two dummy
bytes. The decoder will respond by taking the data line
high to acknowledge that the command was valid and
that learn is active.
The learn status message after the second transmission consists of the following:
• 1 START bit.
• The function code [S3:S0] of the message is zero,
indicating that this is a status string.
• The RESULT bit indicates the result of the learn
sequence. The RESULT bit is set if successful
and cleared otherwise.
• The OVR bit will indicate whether an exiting transmitter is over written. The OVR bit will be set if an
existing transmitter is learned over.
• The [CNT3…CNT0] bits will indicate the number
of transmitters learned on the decoder.
• The [TX3…TX0] bits indicate the block number
used during the learning of the transmitter.
Upon reception of the first transmission, the decoder
will respond with a learn status message (Figure 4-7).
During learn, the decoder will acknowledge the reception of the first transmission by taking the data line high
for 60 ms. The controlling microcontroller can clock out
at most eight bits, which will all be zeros. All of the bits
of the status byte are zero, and this is used to distinguish between a learn time-out status string and the
first transmission received string. The controlling microcontroller must ensure that the clock line does not go
high 60 ms after the falling edge of the data line, for this
will terminate learn.
FIGURE 4-6:
LEARN MODE ACTIVATION
TACK
TLRN
TRESP
CLK
µC DATA
MSB
LSB
Decoder
DATA
Start Command
A
LSB
Command Byte
LSB
MSB
TACK2
Dummy Byte
Dummy Byte
B
FIGURE 4-7:
MSB
Acknowledge
D
C
E
F
LEARN STATUS MESSAGE AFTER FIRST TRANSMISSION
TCA
TCLL
TDS
TCLKH
CLK
TCLH
TCLA
TCLKL
TDHI
0
Decoder
Data
0
Command Request
A
FIGURE 4-8:
0
0
0
0
0
0
Status Byte
B
C
LEARN STATUS MESSAGE AFTER SECOND TRANSMISSION
TCA
TCLL
TCLKL
TDS
TCLKH
CLK
TCLH
TCLA
TDHI
0 OVR RSLT
Decoder
Data
Communications Request
A
DS40153C-page 12
0
0
0
0
1
CNT0
CNT3 TX0
TX3
RX0
Learn Status Bits
B
RX1
RX62 RX63
Decoded Tx
Ci
Cii
 2002 Microchip Technology Inc.
HCS500
4.2.8
ERASE ALL
The erase all command (Figure 4-9) erases all the
transmitters in the decoder. After the command and two
dummy bytes are clocked in, the clock line must be
asserted to activate the command. After a successful
completion of an erase all command, the data line is
asserted until the clock line goes low.
4.3
The HCS500 decoder can also be used in stand-alone
applications. The HCS500 will activate the data line for
up to 500 ms if a valid transmission was received, and
this output can be used to drive a relay circuit. To activate learn or erase all commands, a button must be
connected to the CLK input. User feedback is indicated
on an LED connected to the DATA output line. If the
CLK line is pulled high, using the learn button, the LED
will switch on. After the CLK line is kept high for longer
than 2 seconds, the decoder will switch the LED line off,
indicating that learn will be entered if the button is
released. If the CLK line is kept high for another 6 seconds, the decoder will activate an ERASE_ALL Command.
Learn mode can be aborted by taking the clock line
high until the data line goes high (LED switches on).
During learn, the data line will give feedback to the user
and, therefore, must not be connected to the relay drive
circuitry.
The REPS bit must be cleared in the configuration byte in Stand-alone mode.
After taking the clock low and before a transmitter is
learn, any low-to-high change on the clock line may terminate learn. This has learn implications when a switch
with contact bounce is used.
4.4
Erase All Command and Erase
Command
The Table 4-3 describes two versions of the Erase All
command.
TABLE 4-3:
Programming of the manufacturer’s code.
Erasing of all transmitters
(subcommand 00 only).
Test mode
A special test mode is activated after:
1.
2.
Programming of the manufacturer’s code.
Erasing of all transmitters.
Test mode can be used to test a decoder before any
transmitters are learned on it. Test mode enables testing of decoders without spending the time to learn a
transmitter. Test mode is terminated after the first successful learning of an ordinary transmitter. In test
mode, the decoder responds to a test transmitter. The
test transmitter has the following properties:
1.
2.
3.
4.
crypt key = manufacturer’s code.
Serial number = any value.
Discrimination bits = lower 10 bits of the serial
number.
Synchronization counter value = any value
(synchronization information is ignored).
Because the synchronization counter value is ignored
in test mode, any number of test transmitters can be
used, even if their synchronization counter values are
different.
4.6
Power Supply Supervisor
Reliable operation of the HCS500 requires that the
contents of the EEPROM memory be protected against
erroneous writes. To ensure that erroneous writes do
not occur after supply voltage “brown-out” conditions,
the use of a proper power supply supervisor device
(like Microchip part MCP100-450) is imperative.
ERASE ALL COMMAND
Command
Byte
Subcommand
Byte
C316
0016
Erase all
transmitters.
0116
Erase all transmitters except 1. The
first transmitter in
memory is not
erased.
C316
1.
2.
4.5
Stand-alone Mode
Note:
other transmitters are erased. The first transmitter
learned after any of the following events is the first
transmitter in memory and becomes the permanent
transmitter:
Description
Subcommand 01 can be used where a transmitter with
permanent status is implemented in the microcontroller
software. Use of subcommand 01 ensures that the permanent transmitter remains in memory even when all
 2002 Microchip Technology Inc.
DS40153C-page 13
HCS500
FIGURE 4-9:
ERASE ALL
TACK
TERA
TRESP
CLK
µC DATA
LSB
MSB
LSB
MSB
LSB
MSB
TACK2
Decoder
DATA
Start Command
B
A
Subcommand Byte
Command Byte
C
Dummy Byte
Acknowledge
D
E
F
FIGURE 4-10: STAND-ALONE MODE LEARN/ERASE-ALL TIMING
TPP1
TPP2
TPP3
TPP4
CLK
DATA
Learn Activation
A
B
Erase-All Activation
Successful
C
E
D
FIGURE 4-11: TYPICAL STAND-ALONE APPLICATION CIRCUIT
OUTPUT
Vcc
Vcc
VCC
RF
Receiver
LEARN
1K
1
2
3
4
A0
A1
A2
VSS
VCC
WP
SCL
SDA
RELAY SPST
1
2
3
4
8
7
6
5
VDD
VSS 8
EECLK RFIN 7
EEDAT SCLK 6
5
MCLR SDAT
HCS500
24LC02B
22 µF
VCC
Power Supply
Supervisor
Vi
DS40153C-page 14
10K
10K
LED
RST
MCP100-4.5
Note:
NPN
10K
In-circuit
Programming
Probe Pads (Note)
Because each HCS500 is individually matched to its EEPROM, in-circuit programming is
strongly recommended.
 2002 Microchip Technology Inc.
HCS500
5.0
DECODER PROGRAMMING
The decoder uses a 2K, 24LC02B serial EEPROM. The memory is divided between system memory that stores the
transmitter information (read protected) and user memory (read/write). Commands to access the user memory are
described in Sections 4.2.5 and 4.2.6.
The following information stored in system memory needs to be programmed before the decoder can be used:
• 64-bit manufacturer’s code
• Decoder configuration byte
Note 1: These memory locations are read protected and can only be written to using the program command with
the device powered up.
2: The contents of the system memory is encrypted by a unique 64-bit key that is stored in the HCS500. To
initialize the system memory, the HCS500’s program command must be used. The EEPROM and HCS500
are matched, and the devices must be kept together. In-circuit programming is therefore recommended.
5.1
Configuration Byte
The decoder is configured during initialization by setting the appropriate bits in the configuration byte. The following table
list the options:
5.1.1
Bit
Mnemonic
0
LRN_MODE
1
LRN_ALG
2
REPEAT
3
4
5
6
7
Not Used
Not Used
Not Used
Not Used
Not Used
Description
Learning mode selection
LRN_MODE = 0—Normal Learn
LRN_MODE = 1—Secure Learn
Algorithm selection
LRN_ALG = 0—KEELOQ Decryption Algorithm
LRN_ALG = 1—XOR Algorithm
Repeat Transmission enable
0 = Disable
1 = Enabled
Reserved
Reserved
Reserved
Reserved
Reserved
LRN_MODE
LRN_MODE selects between two learning modes. With LRN_MODE = 0, the Normal (serial number derived) mode is
selected; with LRN_MODE=1, the Secure (seed derived) mode is selected. See Section 6.0 for more detail on learning
modes.
5.1.2
LRN_ALG
LRN_ALG selects between the two available algorithms. With LRN_ALG = 0, is selected the KEELOQ decryption
algorithm is selected; with LRN_ALG = 1, the XOR algorithm is selected. See Section 6.0 for more detail on learning
algorithms.
5.1.3
REPEAT
The HCS500 can be configured to indicate repeated transmissions. In a stand-alone configuration, repeated transmissions must be disabled.
 2002 Microchip Technology Inc.
DS40153C-page 15
HCS500
5.2
Programming Waveform
5.3
The programming command consists of the following:
•
•
•
•
•
A total of 80 bits are clocked into the decoder. The 8-bit
command byte is clocked in first, followed by the 8-bit
configuration byte and the 64-bit manufacturer’s code.
The data must be clocked in Least Significant Bit (LSB)
first. The decoder will then encrypt the manufacturer’s
code using the decoder’s unique 64-bit EEPROM crypt
key. After completion of the programming EEPROM,
the decoder will acknowledge by taking the data line
high (G to H). If the data line goes high within 30 ms
after the clock goes high, programming also fails.
Command Request Sequence (A to B)
Command Byte (B to C)
Configuration Byte (C to D)
Manufacturer’s Code Eight Data Bytes (D to G)
Activation and Acknowledge Sequence (G to H)
FIGURE 5-1:
Programming Data String
PROGRAMMING WAVEFORM
TCLKL
TPP1
TPP3
TCMD
TADDR
TCLKH
TDATA
TDATA
TACK
TWT2
TDS
CLK
µC DATA
LSB
MSB
LSB
MSB
MSB
LSB
MSB
TPP2TPP4
TAW
DECODER
DATA
Start Command
A
DS40153C-page 16
B
Command Byte
Configuration Byte
C
Least Significant Byte
D
E
Most Significant Byte
F
Acknowledge
G
H
 2002 Microchip Technology Inc.
HCS500
6.0
KEY GENERATION
The HCS500 supports three learning schemes which are selected during the initialization of the system EEPROM. The
learning schemes are:
• Normal learn using the KEELOQ decryption algorithm
• Secure learn using the KEELOQ decryption algorithm
• Secure learn using the XOR algorithm
6.1
Normal (Serial Number derived) Learn using the KEELOQ Decryption Algorithm
This learning scheme uses the KEELOQ decryption algorithm and the 28-bit serial number of the transmitter to derive
the crypt key. The 28-bit serial number is patched with predefined values as indicated below to form two 32-bit seeds.
SourceH = 60000000 00000000H + Serial Number | 28 Bits
SourceL = 20000000 00000000H + Serial Number | 28 Bits
Then, using the KEELOQ decryption algorithm and the manufacturer’s code the crypt key is derived as follows:
KeyH Upper 32 bits = F KEELOQ Decryption (SourceH) | 64-Bit Manufacturer’s Code
KeyL Lower 32 bits = F KEELOQ Decryption (SourceL) | 64-Bit Manufacturer’s Code
6.2
Secure (Seed Derived) Learn using the KEELOQ Decryption Algorithm
This scheme uses the secure seed transmitted by the encoder to derive the two input seeds. The decoder always uses
the lower 64 bits of the transmission to form a 60-bit seed. The upper 4 bits are always forced to zero.
For 32-bit seed encoders (HCS200, HCS201, HCS300, HCS301):
SourceH = Serial Number Lower 28 bits
SourceL = Seed 32 bits
For 48-bit seed encoders (HCS360, HCS361):
SourceH = Serial Number (with upper 4 bits set to zero) Upper 16 bits <<16 + Seed Upper 16 bits
SourceL = Seed Lower 32 bits
For 60-bit seed encoders (HCS362, HCS365, HCS370, HCS410, HCS412, HCS473):
SourceH = Seed Upper 32 bits (with upper 4 bits set to zero)
SourceL = Seed Lower 32 bits
The KEELOQ decryption algorithm and the manufacturer’s code is used to derive the crypt key as follows:
KeyH Upper 32 bits = Decrypt (SourceH) 64 Bit Manufacturer’s Code
KeyL Lower 32 bits = Decrypt (SourceL) 64 Bit Manufacturer’s Code
6.3
Secure (Seed Derived) Learn using the XOR Algorithm
This scheme uses the seed transmitted by the encoder to derive the two input seeds. The decoder always use the lower
64 bits of the transmission to form a 60-bit seed. The upper 4 bits are always forced to zero.
For 32-bit seed encoders (HCS200, HCS201, HCS300, HCS301):
SourceH = Serial Number Lower 28 bits
SourceL = Seed 32 bits
For 48-bit seed encoders (HCS360/HCS361):
SourceH = Serial Number (with upper 4 bits set to zero) Upper 16 bits <<16 + Seed Upper 16 bits
SourceL = Seed Lower 32 bits
For 60-bit seed encoders (HCS362, HCS365, HCS370, HCS410, HCS412, HCS473):
SourceH = Seed Upper 32 bits with upper 4 bits set to zero
SourceL = Seed Lower 32 bits
Then, using the manufacturer’s code the crypt key is derived as follows:
KeyH Upper 32 bits = SourceH XOR 64-Bit Manufacturer’s Code Upper 32 bits
KeyL Lower 32 bits = SourceL XOR 64-Bit Manufacturer’s Code Lower 32 bits
 2002 Microchip Technology Inc.
DS40153C-page 17
HCS500
7.0
KEELOQ ENCODERS
7.1
Transmission Format (PWM)
bits, and the 28-bit serial number. The encrypted and
non-encrypted combined sections increase the number
of combinations to 7.38 x 1019.
The KEELOQ encoder transmission is made up of several parts (Figure 7-1). Each transmission begins with
a preamble and a header, followed by the encrypted
and then the fixed data. The actual data is 66/69 bits
which consists of 32 bits of encrypted data and 34/35
bits of non-encrypted data. Each transmission is followed by a guard period before another transmission
can begin. The code hopping portion provides up to
four billion changing code combinations and includes
the button status bits (based on which buttons were
activated), along with the synchronization counter
value and some discrimination bits. The non-code hopping portion is comprised of the status bits, the function
FIGURE 7-1:
7.2
Code Word Organization
The HCS encoder transmits a 66/69-bit code word
when a button is pressed. The 66/69-bit word is constructed from a code hopping portion and a non-code
hopping portion (Figure 7-2).
The Encrypted Data is generated from four button bits,
two overflow counter bits, ten discrimination bits, and
the 16-bit synchronization counter value.
The Non-encrypted Data is made up from 2 status
bits, 4 function bits, and the 28/32-bit serial number.
TRANSMISSION FORMAT (PWM)
TE
TE
TE
LOGIC "0"
LOGIC "1"
TBP
50% Preamble
FIGURE 7-2:
10xTE
Header
Fixed Code
Portion
Guard
Time
CODE WORD ORGANIZATION
34 bits of Fixed Portion
Repeat VLOW
(1-bit) (1-bit)
MSb
Button
Status
S2 S1 S0 S3
Serial Number
(28 bits)
32 bits of Encrypted Portion
Button
Status
S2 S1 S0 S3
OVR
(2 bits)
DISC
(10 bits)
Sync Counter
(16 bits)
66 Data bits
Transmitted
LSb first.
Repeat VLOW
(1-bit) (1-bit)
MSb
Encrypted
Portion
Button
Status
1 1 1 1
Serial Number
(28 bits)
LSb
SEED
(32 bits)
LSb
SEED replaces Encrypted Portion when all button inputs are activated at the same time.
DS40153C-page 18
 2002 Microchip Technology Inc.
HCS500
8.0
ELECTRICAL CHARACTERISTICS FOR HCS500
Absolute Maximum Ratings†
Ambient temperature under bias............................................................................................................ -40°C to +125°C
Storage temperature .............................................................................................................................. -65 °C to +150°C
Voltage on any pin with respect to VSS (except VDD)......................................................................... -0.6V to VDD +0.6V
Voltage on VDD with respect to Vss ..................................................................................................................0 to +7.5V
Total power dissipation (Note) .............................................................................................................................700 mW
Maximum current out of VSS pin ...........................................................................................................................200 mA
Maximum current into VDD pin ..............................................................................................................................150 mA
Input clamp current, IIK (VI < 0 or VI > VDD) ......................................................................................................... ± 20 mA
Output clamp current, IOK (VO < 0 or VO >VDD) ..................................................................................................± 20 mA
Maximum output current sunk by any I/O pin..........................................................................................................25 mA
Maximum output current sourced by any I/O pin ....................................................................................................25 mA
Note:
Power dissipation is calculated as follows: PDIS = VDD x {IDD - ∑ IOH} + ∑ {(VDD–VOH) x IOH} + ∑(VOl x IOL)
†
NOTICE: Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the
device. This is a stress rating only and functional operation of the device at those or any other conditions above
those indicated in the operation listings of this specification is not implied. Exposure to maximum rating conditions for
extended periods may affect device reliability.
 2002 Microchip Technology Inc.
DS40153C-page 19
HCS500
TABLE 8-1:
DC CHARACTERISTICS
Standard Operating Conditions (unless otherwise stated)
Operating temperature
Commercial (C):
0°C ≤ TA ≤ +70°C
Industrial (I):
-40°C ≤ TA ≤ +85°C
Symbol
Parameters
Min
Typ(†)
Max
Units
Conditions
VDD
Supply voltage
3.0
—
5.5
V
VPOR
VDD start voltage to
ensure RESET
—
Vss
—
V
SVDD
VDD rise rate to
ensure RESET
0.05*
—
—
V/ms
IDD
Supply current
—
—
1.8
0.3
2.4
5
mA
µA
FOSC = 4 MHz, VDD = 5.5V
SLEEP mode (no RF input)
IPD
Power-Down Current
—
0.25
4
µA
VDD = 3.0V, Commercial
VIL
VIH
Input low voltage
Input high voltage
—
0.3
5
µA
VDD = 3.0V, Industrial
VSS
VSS
—
—
0.8
0.15 VDD
V
V
VDD between 4.5V and 5.5V
Otherwise
VSS
—
0.15 VDD
V
MCLR
2.0
0.25 VDD + 0.8
—
—
VDD
VDD
V
V
VDD between 4.5V and 5.5V
Otherwise
0.85 VDD
—
VDD
V
MCLR
VOL
Output low voltage
—
—
0.6
V
IOL = 8.7 mA, VDD = 4.5V
VOH
Output high voltage
VDD - 0.7
—
—
V
IOH = -5.4 mA, VDD = 4.5V
† Data in “Typ” column is at 5.0V, 25°C unless otherwise stated. These parameters are for design guidance only
and are not tested.
* These parameters are characterized but not tested.
Note:
Negative current is defined as coming out of the pin.
TABLE 8-2:
AC CHARACTERISTICS
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C ≤ TA ≤ +70°C
Industrial (I):
-40°C ≤ TA ≤ +85°C
Symbol
TE
TOD
TMCLR
TOV
*
Parameters
Min
Typ
Max
Units
65
—
660
µs
Output delay
48
75
237
ms
MCLR low time
150
—
—
ns
—
150
222
ms
Transmit elemental period
Time output valid
Conditions
These parameters are characterized but not tested.
DS40153C-page 20
 2002 Microchip Technology Inc.
HCS500
FIGURE 8-1:
RESET WATCHDOG TIMER, OSCILLATOR START-UP TIMER AND POWER-UP
TIMER TIMING
VDD
MCLR
TMCLR
Tov
I/O Pins
 2002 Microchip Technology Inc.
DS40153C-page 21
HCS500
8.1
AC Electrical Characteristics
8.1.1
COMMAND MODE ACTIVATION
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C ≤ TA ≤ +70°C
Industrial (I):
-40°C ≤ TA ≤ +85°C
Symbol
*
Parameters
Min
Typ
Max
Units
TREQ
Command request time
0.0150
—
500
ms
TRESP
Microcontroller request
acknowledge time
—
—
1
ms
TACK
Decoder acknowledge time
—
—
30
µs
TSTART
Start Command mode to first
command bit
20
—
1000
µs
TCLKH
Clock high time
20
—
1000
µs
TCLKL
Clock low time
20
—
1000
µs
FCLK
Clock frequency
500
—
25000
Hz
TDS
Data hold time
14
—
—
µs
TCMD
Command validate time
—
—
10
µs
TADDR
Address validate time
—
—
10
µs
TDATA
Data validate time
—
—
10
µs
These parameters are characterized but not tested.
8.1.2
READ FROM USER EEPROM COMMAND
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C ≤ TA ≤ +70°C
Industrial (I):
-40°C ð TA ≤ +85°C
Symbol
TRD
*
Parameters
Decoder EEPROM read time
Min
Typ
Max
Units
400
—
1500
µs
These parameters are characterized but not tested.
8.1.3
WRITE TO USER EEPROM COMMAND
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C ≤ TA ≤ +70°C
Industrial (I):
-40°C ≤ TA ≤ +85°C
Symbol
*
Parameters
Min
Typ
Max
Units
TWR
Write command activation time
20
—
1000
µs
TACK
EEPROM write acknowledge time
—
—
10
ms
TRESP
Microcontroller acknowledge
response time
20
—
1000
µs
TACK2
Decoder response
acknowledge time
—
—
10
µs
These parameters are characterized but not tested.
DS40153C-page 22
 2002 Microchip Technology Inc.
HCS500
8.1.4
ACTIVATE LEARN COMMAND IN MICRO MODE
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C ≤ TA ≤ +70 °C
Industrial (I):
-40°C ≤ TA ≤ +85°C
Symbol
*
Parameters
Min
Typ
Max
Units
TLRN
Learn command activation time
20
—
1000
µs
TACK
Decoder acknowledge time
—
—
20
µs
TRESP
Microcontroller acknowledge
response time
20
—
1000
µs
TACK2
Decoder data line low
—
—
10
µs
These parameters are characterized but not tested.
8.1.5
ACTIVATE LEARN COMMAND IN STAND-ALONE MODE
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C ≤ TA ≤ +70°C
Industrial (I):
-40°C ≤ TA ≤ +85°C
Symbol
*
Parameters
Min
Typ
Max
Units
TPP1
Command request time
—
—
100
ms
TPP2
Learn command activation time
—
—
2
s
TPP3
Erase-all command activation time
—
—
6
s
These parameters are characterized but not tested.
8.1.6
LEARN STATUS STRING
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C ≤ TA ≤ +70°C
Industrial (I):
-40°C ð TA ≤ +85°C
Symbol
*
Parameters
TDHI
Command request time
TCLA
Microcontroller command
request time
TCA
Decoder request
acknowledge time
TCLH
Clock high hold time
TCLL
Clock low hold time
Min
Typ
Max
Units
—
—
500
ms
0.005
—
500
ms
—
—
10
µs
1.2
ms
0.020
—
1.2
ms
TCLKH
Clock high time
20
—
1000
µs
TCLKL
Clock low time
20
—
1000
µs
FCLK
Clock frequency
500
—
25000
Hz
TDS
Data hold time
—
—
5
µs
These parameters are characterized but not tested.
 2002 Microchip Technology Inc.
DS40153C-page 23
HCS500
8.1.7
ERASE ALL COMMAND
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C ≤ TA ≤ +70°C
Industrial (I):
-40°C ≤ TA ≤ +85°C
Symbol
*
Parameters
Min
Typ
Max
Units
TERA
Learn command activation time
20
—
1000
µs
TACK
Decoder acknowledge time
20
—
210
ms
TRESP
Microcontroller acknowledge
response time
20
—
1000
µs
TACK2
Decoder data line low
—
—
10
µs
These parameters are characterized but not tested.
8.1.8
PROGRAMMING COMMAND
Standard Operating Conditions (unless otherwise specified):
Commercial (C): 0°C ≤ TA ≤ +70°C
Industrial (I):
-40°C ≤ TA ≤ +85°C
Symbol
*
Parameters
Min
Typ
Max
Units
TPP1
Command request time
—
—
500
ms
TPP2
Decoder acknowledge time
—
—
1
ms
TPP3
Start Command mode to first
command bit
20
—
1000
µs
TPP4
Data line low before tri-stated
—
—
5
µs
TCLKH
Clock high time
20
—
1000
µs
TCLKL
Clock low time
20
—
1000
µs
FCLK
Clock frequency
500
—
25000
Hz
TDS
Data hold time
—
—
5
µs
TCMD
Command validate time
—
—
10
µs
TACK
Command acknowledge time
30
—
240
ms
TWT2
Acknowledge respond time
20
—
1000
µs
TALW
Data low after clock low
—
—
10
µs
These parameters are characterized but not tested.
DS40153C-page 24
 2002 Microchip Technology Inc.
HCS500
FIGURE 8-2:
TYPICAL MICROCONTROLLER INTERFACE CIRCUIT
VCC
RF
Receiver
1K
Microcontroller
1
2
3
4
A0
A1
A2
VSS
VCC
WP
SCL
SDA
1
2
3
4
8
7
6
5
VDD
VSS 8
EECLK RFIN 7
EEDAT SCLK 6
5
MCLR SDAT
CLOCK
DATA
MCLR
HCS500
24LC02B
10K
VCC
Power Supply
Supervisor
Vi
RST
In-circuit
Programming
Probe Pads (Note)
MCP100-4.5
Note:
Because each HCS500 is individually matched to its EEPROM, in-circuit programming is
strongly recommended.
 2002 Microchip Technology Inc.
DS40153C-page 25
HCS500
9.0
PACKAGING INFORMATION
9.1
Package Marking Information
8-Lead PDIP (300 mil)
Example
XXXXXXXX
XXXXXNNN
YYWW
HCS500
XXXXXNNN
0025
8-Lead SOIC (150 mil)
Example
XXXXXXX
XXXYYWW
NNN
HCS500
XXX0025
NNN
Legend:
Note:
*
XX...X
Y
YY
WW
NNN
Customer specific information*
Year code (last digit of calendar year)
Year code (last 2 digits of calendar year)
Week code (week of January 1 is week ‘01’)
Alphanumeric traceability code
In the event the full Microchip part number cannot be marked on one line, it will
be carried over to the next line thus limiting the number of available characters
for customer specific information.
Standard PICmicro device marking consists of Microchip part number, year code, week code, and
traceability code. For PICmicro device marking beyond this, certain price adders apply. Please check
with your Microchip Sales Office. For QTP devices, any special marking adders are included in QTP
price.
DS40153C-page 26
 2002 Microchip Technology Inc.
HCS500
9.2
Package Details
8-Lead Plastic Dual In-line (P) - 300 mil (PDIP)
E1
D
2
n
1
α
E
A2
A
L
c
A1
β
B1
p
eB
B
Units
Dimension Limits
n
p
Number of Pins
Pitch
Top to Seating Plane
Molded Package Thickness
Base to Seating Plane
Shoulder to Shoulder Width
Molded Package Width
Overall Length
Tip to Seating Plane
Lead Thickness
Upper Lead Width
Lower Lead Width
Overall Row Spacing
Mold Draft Angle Top
Mold Draft Angle Bottom
* Controlling Parameter
§ Significant Characteristic
A
A2
A1
E
E1
D
L
c
§
B1
B
eB
α
β
MIN
.140
.115
.015
.300
.240
.360
.125
.008
.045
.014
.310
5
5
INCHES*
NOM
MAX
8
.100
.155
.130
.170
.145
.313
.250
.373
.130
.012
.058
.018
.370
10
10
.325
.260
.385
.135
.015
.070
.022
.430
15
15
MILLIMETERS
NOM
8
2.54
3.56
3.94
2.92
3.30
0.38
7.62
7.94
6.10
6.35
9.14
9.46
3.18
3.30
0.20
0.29
1.14
1.46
0.36
0.46
7.87
9.40
5
10
5
10
MIN
MAX
4.32
3.68
8.26
6.60
9.78
3.43
0.38
1.78
0.56
10.92
15
15
Notes:
Dimensions D and E1 do not include mold flash or protrusions. Mold flash or protrusions shall not exceed
.010” (0.254mm) per side.
JEDEC Equivalent: MS-001
Drawing No. C04-018
 2002 Microchip Technology Inc.
DS40153C-page 27
HCS500
8-Lead Plastic Small Outline (SM) - Medium, 208 mil (SOIC)
E
E1
p
D
2
n
1
B
α
c
A2
A
φ
β
L
Units
Dimension Limits
n
p
Number of Pins
Pitch
Overall Height
Molded Package Thickness
Standoff §
Overall Width
Molded Package Width
Overall Length
Foot Length
Foot Angle
Lead Thickness
Lead Width
Mold Draft Angle Top
Mold Draft Angle Bottom
A
A2
A1
E
E1
D
L
φ
c
B
α
β
MIN
.070
.069
.002
.300
.201
.202
.020
0
.008
.014
0
0
INCHES*
NOM
8
.050
.075
.074
.005
.313
.208
.205
.025
4
.009
.017
12
12
A1
MAX
.080
.078
.010
.325
.212
.210
.030
8
.010
.020
15
15
MILLIMETERS
NOM
8
1.27
1.78
1.97
1.75
1.88
0.05
0.13
7.62
7.95
5.11
5.28
5.13
5.21
0.51
0.64
0
4
0.20
0.23
0.36
0.43
0
12
0
12
MIN
MAX
2.03
1.98
0.25
8.26
5.38
5.33
0.76
8
0.25
0.51
15
15
* Controlling Parameter
§ Significant Characteristic
Notes:
Dimensions D and E1 do not include mold flash or protrusions. Mold flash or protrusions shall not exceed
.010” (0.254mm) per side.
Drawing No. C04-056
DS40153C-page 28
 2002 Microchip Technology Inc.
HCS500
ON-LINE SUPPORT
Microchip provides on-line support on the Microchip
World Wide Web (WWW) site.
The web site is used by Microchip as a means to make
files and information easily available to customers. To
view the site, the user must have access to the Internet
and a web browser, such as Netscape or Microsoft
Explorer. Files are also available for FTP download
from our FTP site.
Systems Information and Upgrade Hot Line
The Systems Information and Upgrade Line provides
system users a listing of the latest versions of all of
Microchip's development systems software products.
Plus, this line provides information on how customers
can receive any currently available upgrade kits.The
Hot Line Numbers are:
1-800-755-2345 for U.S. and most of Canada, and
1-480-792-7302 for the rest of the world.
Connecting to the Microchip Internet Web Site
The Microchip web site is available by using your
favorite Internet browser to attach to:
www.microchip.com
The file transfer site is available by using an FTP service to connect to:
ftp://ftp.microchip.com
The web site and file transfer site provide a variety of
services. Users may download files for the latest
Development Tools, Data Sheets, Application Notes,
User’s Guides, Articles and Sample Programs. A variety of Microchip specific business information is also
available, including listings of Microchip sales offices,
distributors and factory representatives. Other data
available for consideration is:
• Latest Microchip Press Releases
• Technical Support Section with Frequently Asked
Questions
• Design Tips
• Device Errata
• Job Postings
• Microchip Consultant Program Member Listing
• Links to other useful web sites related to
Microchip Products
• Conferences for products, Development Systems,
technical information and more
• Listing of seminars and events
 2002 Microchip Technology Inc.
DS40153C-page 29
HCS500
READER RESPONSE
It is our intention to provide you with the best documentation possible to ensure successful use of your Microchip product. If you wish to provide your comments on organization, clarity, subject matter, and ways in which our documentation
can better serve you, please FAX your comments to the Technical Publications Manager at (480) 792-4150.
Please list the following information, and use this outline to provide us with your comments about this Data Sheet.
To:
Technical Publications Manager
RE:
Reader Response
Total Pages Sent
From: Name
Company
Address
City / State / ZIP / Country
Telephone: (_______) _________ - _________
FAX: (______) _________ - _________
Application (optional):
Would you like a reply?
Device: HCS500
Y
N
Literature Number: DS40153C
Questions:
1. What are the best features of this document?
2. How does this document meet your hardware and software development needs?
3. Do you find the organization of this data sheet easy to follow? If not, why?
4. What additions to the data sheet do you think would enhance the structure and subject?
5. What deletions from the data sheet could be made without affecting the overall usefulness?
6. Is there any incorrect or misleading information (what and where)?
7. How would you improve this document?
8. How would you improve our software, systems, and silicon products?
DS40153C-page 30
 2002 Microchip Technology Inc.
HCS500
HCS500 PRODUCT IDENTIFICATION SYSTEM
To order or obtain information, e.g., on pricing or delivery, refer to the factory or the listed sales office.
HCS500
—
/P
Package:
P = Plastic DIP (300 mil Body), 8-lead
SM = Plastic SOIC (207 mil Body), 8-lead
Temperature
Range:
Device:
Blank = 0°C to +70°C
I = –40°C to +85°C
HCS500
HCS500T
Code Hopping Decoder
Code Hopping Decoder (Tape and Reel)
Sales and Support
Data Sheets
Products supported by a preliminary Data Sheet may have an errata sheet describing minor operational differences and recommended workarounds. To determine if an errata sheet exists for a particular device, please contact one of the following:
1.
2.
3.
Your local Microchip sales office
The Microchip Corporate Literature Center U.S. FAX: (480) 792-7277
The Microchip Worldwide Site (www.microchip.com)
Please specify which device, revision of silicon and Data Sheet (include Literature #) you are using.
New Customer Notification System
Register on our web site (www.microchip.com/cn) to receive the most current information on our products.
 2002 Microchip Technology Inc.
DS40153C-page 31
HCS500
NOTES:
DS40153C-page 32
 2002 Microchip Technology Inc.
Microchip’s Secure Data Products are covered by some or all of the following patents:
Code hopping encoder patents issued in Europe, U.S.A., and R.S.A. — U.S.A.: 5,517,187; Europe: 0459781; R.S.A.: ZA93/4726
Secure learning patents issued in the U.S.A. and R.S.A. — U.S.A.: 5,686,904; R.S.A.: 95/5429
Information contained in this publication regarding device
applications and the like is intended through suggestion only
and may be superseded by updates. It is your responsibility to
ensure that your application meets with your specifications.
No representation or warranty is given and no liability is
assumed by Microchip Technology Incorporated with respect
to the accuracy or use of such information, or infringement of
patents or other intellectual property rights arising from such
use or otherwise. Use of Microchip’s products as critical components in life support systems is not authorized except with
express written approval by Microchip. No licenses are conveyed, implicitly or otherwise, under any intellectual property
rights.
Trademarks
The Microchip name and logo, the Microchip logo, FilterLab,
KEELOQ, MPLAB, PIC, PICmicro, PICMASTER, PICSTART,
PRO MATE, SEEVAL and The Embedded Control Solutions
Company are registered trademarks of Microchip Technology
Incorporated in the U.S.A. and other countries.
dsPIC, ECONOMONITOR, FanSense, FlexROM, fuzzyLAB,
In-Circuit Serial Programming, ICSP, ICEPIC, microID,
microPort, Migratable Memory, MPASM, MPLIB, MPLINK,
MPSIM, MXDEV, PICC, PICDEM, PICDEM.net, rfPIC, Select
Mode and Total Endurance are trademarks of Microchip
Technology Incorporated in the U.S.A.
Serialized Quick Turn Programming (SQTP) is a service mark
of Microchip Technology Incorporated in the U.S.A.
All other trademarks mentioned herein are property of their
respective companies.
© 2002, Microchip Technology Incorporated, Printed in the
U.S.A., All Rights Reserved.
Printed on recycled paper.
Microchip received QS-9000 quality system
certification for its worldwide headquarters,
design and wafer fabrication facilities in
Chandler and Tempe, Arizona in July 1999. The
Company’s quality system processes and
procedures are QS-9000 compliant for its
PICmicro® 8-bit MCUs, KEELOQ® code hopping
devices, Serial EEPROMs and microperipheral
products. In addition, Microchip’s quality
system for the design and manufacture of
development systems is ISO 9001 certified.
 2002 Microchip Technology Inc.
DS40153C - page 33
WORLDWIDE SALES AND SERVICE
AMERICAS
ASIA/PACIFIC
Japan
Corporate Office
Australia
2355 West Chandler Blvd.
Chandler, AZ 85224-6199
Tel: 480-792-7200 Fax: 480-792-7277
Technical Support: 480-792-7627
Web Address: http://www.microchip.com
Microchip Technology Australia Pty Ltd
Suite 22, 41 Rawson Street
Epping 2121, NSW
Australia
Tel: 61-2-9868-6733 Fax: 61-2-9868-6755
Microchip Technology Japan K.K.
Benex S-1 6F
3-18-20, Shinyokohama
Kohoku-Ku, Yokohama-shi
Kanagawa, 222-0033, Japan
Tel: 81-45-471- 6166 Fax: 81-45-471-6122
Rocky Mountain
China - Beijing
2355 West Chandler Blvd.
Chandler, AZ 85224-6199
Tel: 480-792-7966 Fax: 480-792-7456
Microchip Technology Consulting (Shanghai)
Co., Ltd., Beijing Liaison Office
Unit 915
Bei Hai Wan Tai Bldg.
No. 6 Chaoyangmen Beidajie
Beijing, 100027, No. China
Tel: 86-10-85282100 Fax: 86-10-85282104
Atlanta
500 Sugar Mill Road, Suite 200B
Atlanta, GA 30350
Tel: 770-640-0034 Fax: 770-640-0307
Boston
2 Lan Drive, Suite 120
Westford, MA 01886
Tel: 978-692-3848 Fax: 978-692-3821
Chicago
333 Pierce Road, Suite 180
Itasca, IL 60143
Tel: 630-285-0071 Fax: 630-285-0075
Dallas
4570 Westgrove Drive, Suite 160
Addison, TX 75001
Tel: 972-818-7423 Fax: 972-818-2924
Detroit
Tri-Atria Office Building
32255 Northwestern Highway, Suite 190
Farmington Hills, MI 48334
Tel: 248-538-2250 Fax: 248-538-2260
Kokomo
2767 S. Albright Road
Kokomo, Indiana 46902
Tel: 765-864-8360 Fax: 765-864-8387
Los Angeles
18201 Von Karman, Suite 1090
Irvine, CA 92612
Tel: 949-263-1888 Fax: 949-263-1338
China - Chengdu
Microchip Technology Consulting (Shanghai)
Co., Ltd., Chengdu Liaison Office
Rm. 2401, 24th Floor,
Ming Xing Financial Tower
No. 88 TIDU Street
Chengdu 610016, China
Tel: 86-28-6766200 Fax: 86-28-6766599
China - Fuzhou
Microchip Technology Consulting (Shanghai)
Co., Ltd., Fuzhou Liaison Office
Unit 28F, World Trade Plaza
No. 71 Wusi Road
Fuzhou 350001, China
Tel: 86-591-7503506 Fax: 86-591-7503521
China - Shanghai
Microchip Technology Consulting (Shanghai)
Co., Ltd.
Room 701, Bldg. B
Far East International Plaza
No. 317 Xian Xia Road
Shanghai, 200051
Tel: 86-21-6275-5700 Fax: 86-21-6275-5060
China - Shenzhen
150 Motor Parkway, Suite 202
Hauppauge, NY 11788
Tel: 631-273-5305 Fax: 631-273-5335
Microchip Technology Consulting (Shanghai)
Co., Ltd., Shenzhen Liaison Office
Rm. 1315, 13/F, Shenzhen Kerry Centre,
Renminnan Lu
Shenzhen 518001, China
Tel: 86-755-2350361 Fax: 86-755-2366086
San Jose
Hong Kong
Microchip Technology Inc.
2107 North First Street, Suite 590
San Jose, CA 95131
Tel: 408-436-7950 Fax: 408-436-7955
Microchip Technology Hongkong Ltd.
Unit 901-6, Tower 2, Metroplaza
223 Hing Fong Road
Kwai Fong, N.T., Hong Kong
Tel: 852-2401-1200 Fax: 852-2401-3431
New York
Toronto
6285 Northam Drive, Suite 108
Mississauga, Ontario L4V 1X5, Canada
Tel: 905-673-0699 Fax: 905-673-6509
India
Microchip Technology Inc.
India Liaison Office
Divyasree Chambers
1 Floor, Wing A (A3/A4)
No. 11, O’Shaugnessey Road
Bangalore, 560 025, India
Tel: 91-80-2290061 Fax: 91-80-2290062
Korea
Microchip Technology Korea
168-1, Youngbo Bldg. 3 Floor
Samsung-Dong, Kangnam-Ku
Seoul, Korea 135-882
Tel: 82-2-554-7200 Fax: 82-2-558-5934
Singapore
Microchip Technology Singapore Pte Ltd.
200 Middle Road
#07-02 Prime Centre
Singapore, 188980
Tel: 65-334-8870 Fax: 65-334-8850
Taiwan
Microchip Technology Taiwan
11F-3, No. 207
Tung Hua North Road
Taipei, 105, Taiwan
Tel: 886-2-2717-7175 Fax: 886-2-2545-0139
EUROPE
Denmark
Microchip Technology Nordic ApS
Regus Business Centre
Lautrup hoj 1-3
Ballerup DK-2750 Denmark
Tel: 45 4420 9895 Fax: 45 4420 9910
France
Microchip Technology SARL
Parc d’Activite du Moulin de Massy
43 Rue du Saule Trapu
Batiment A - ler Etage
91300 Massy, France
Tel: 33-1-69-53-63-20 Fax: 33-1-69-30-90-79
Germany
Microchip Technology GmbH
Gustav-Heinemann Ring 125
D-81739 Munich, Germany
Tel: 49-89-627-144 0 Fax: 49-89-627-144-44
Italy
Microchip Technology SRL
Centro Direzionale Colleoni
Palazzo Taurus 1 V. Le Colleoni 1
20041 Agrate Brianza
Milan, Italy
Tel: 39-039-65791-1 Fax: 39-039-6899883
United Kingdom
Arizona Microchip Technology Ltd.
505 Eskdale Road
Winnersh Triangle
Wokingham
Berkshire, England RG41 5TU
Tel: 44 118 921 5869 Fax: 44-118 921-5820
01/18/02
DS40153C-page 34
 2002 Microchip Technology Inc.
Similar pages