AHF-10 Series 10 Watts Universal Input Range AC/DC Power Modules Single and Dual Outputs Key Features y y y y y y y y y y High Efficiency up to 77% 85~265VAC, 47~440Hz Universal Input Range Single and Dual Output Modules I/O Isolation 3000VAC EMI Complies With EN55022 Class B and FCC part 15, level B EMC Complies With EN61000 MTBF > 300,000 Hours UL 60950-1 Safety Approval IEC61140 Safety Class II Approval Operating Temperature 71] (Reference to Derating Curve) AHF-10 is a 10-Watt series of AC-DC power modules. These modules have universal input range of 85-265VAC and are available in output voltages of 3.3V, 5V, 12V, 15V, 24V, ±12 and ±15V with efficiency as high as 77%. ~ 85 265 VAC Other features include continuous short circuit protection, overvoltage protection, output current limitation, EMC EN61000-4(-2,-3,-4) and EMI EN55022 level B approved which conducted noise compliance minimize design-in time, cost and eliminate the need for external components. 3000 VAC The AHF-10 series has IEC / EN / UL 60950-1 safety approval qualifies this product for worldwide markets. The series is a wide variety of applications including in commercial and industrial of the MTBF 300,000 hours. I/O Isolation OVP Universal Voltage Protection EMI EMC EN55022 EN61000 Derating Curve 100 Output Power (%) 80 60 40 25% 20 0 ~ -25 10 20 30 40 50 60 70 Ambient Temperature ] 1 MINMAX REV:9 2008/10 AHF-10 Series Model Selection Guide Model Number Output Voltage AHF-10S03 AHF-10S05 AHF-10S12 AHF-10S15 AHF-10S24 AHF-10D12 AHF-10D15 # VDC 3.3 5 12 15 24 {12 {15 Output Current Max. mA 2000 2000 833 666 416 {380 {300 Capacitive Load Input Current Efficiency Max. uF 3900 3300 2200 2200 1000 # 1000 # 1000 115VAC, 60Hz @Max. Load @No Load mA (Typ.) mA (Typ.) 137 15 199 15 191 15 191 15 190 15 172 15 169 15 @Max. Load % (Typ.) 70 73 76 76 76 77 77 Min. mA 200 200 83 66 42 {38 {30 For each output. Note : Environmental Specifications Parameter Operating Temperature Storage Temperature Humidity Cooling Conducted EMI Conditions Ambient Min. Max. -25 71 -40 85 --95 Free-Air Convection EN55022 Class B Unit ] ] % Standard specification requirement Performance Criteria EN61000-4-2 Air {8KV Cont. {4KV B EN61000-4-3 80~1000MHz 10V/m 80% AM1KHz modulation A EN61000-4-4 AC port {2KV DC, SL, TL {2KV not less than 1 min. B EN61000-4-5 1.2/50uS(8/20uS) AC dif. {1KV DC {0.5KV B EN61000-4-6 0.15~80MHz 10Vrms (functional earth ports included) 80% AM 1kHz modulation B EN61000-4-11 30% 10ms 60% 100ms 95% 5000ms B C C Conducted EMC 1. Specifications typical at Ta=+25], resistive load, 115VAC, 60Hz input voltage, rated output current unless otherwise noted. 2. Ripple & Noise measurement bandwidth is 0-20 MHz. 3. These power modules require a minimum output loading to maintain specified regulation. 4. Operation under no-load conditions will not damage these devices; however they may not meet all listed specifications. 5. Other input and output voltage may be available, please contact factory. 6. Specifications subject to change without notice. Input Specifications Parameter Input Voltage Range Input Frequency Range Inrush Current (Cold Start at 25]) REV:9 2008/10 Conditions All Models Min. Typ. Max. Unit 85 --- 265 VAC 47 --- 440 Hz 115VAC --- --- 10 A 230VAC --- --- 20 A MINMAX 2 AHF-10 Series Input Fuse All Models Built-in Fuse 2A / 250VAC External Fuse (Recommended) 1.5A Slow - Blow Type Output Specifications Parameter Conditions Min. Typ. Max. Unit --- {1.0 {2.0 % --- {0.5 {1.0 % --- {0.5 {1.0 % --- {2.5 {5.0 % 3.3 & 5.0VDC Output Models --- 1.5 1.8 %Vpp of Vo Other Output Models --- 0.8 1.0 %Vpp of Vo Zener diode clamp --- 120 --- % of Vo Temperature Coefficient --- {0.01 {0.02 %/] Overshoot --- --- 5.0 % 105 --- --- % Output Voltage Accuracy Line Regulation Vin=Min. to Max. Load Regulation - Single output Iout=Min. to Max. - Dual output Ripple & Noise (20MHz) Over Voltage Protection Current limitation 85VAC, Hiccup technique, auto-recovery Short circuit protection Hiccup mode, indefinite (automatic recovery) General Specifications Parameter Isolation Voltage Isolation Test Voltage Conditions Min. Typ. Max. Unit Input to Output, 60 Seconds 3000 --- --- VAC Input to Output, Flash Tested for 1 Second 4700 --- --- VDC 500VDC 100 --- --- M[ --- 100 --- KHz Isolation Resistance Switching Frequency Hold-up Time MTBF 115VAC, 60Hz --- 20 --- ms MIL-HDBK-217F @ 25], Ground Benign 300 --- --- K Hours Block Diagram Single Output L Fuse +Vo Rectifier Rectifier OVP N EMI Filter and Inrush Current Limiter Switching Device -Vo Control Circuit Isolation Ref.Amp Dual Output L N Fuse EMI Filter and Rectifier Lnrush Current Inrush Line Current FilterLimiter Limiter and Rectifier Rectifier Rectifier Switching Device Switching Device Rectifier Rectifier N Control Circuit PWM 3 +Vo OVP Fuse OVP L Isolation Isolation MINMAX +Vo Com. Com. -Vo -Vo Ref.Amp OVP Ref.Amp REV:9 2008/10 AHF-10 Series Pin Connections Mechanical Dimensions Pin 19.0 [0.75] 10.16 [0.40] 10.16 [0.40] 6.0 [0.24] Single Output AC(N) - AC Neutral 2 AC(L) - AC Line 3 0.5 [0.02] -Vout 1 Common +Vout NC: No Connection Side 5.0 [0.20] 2 NC Physical Characteristics 64.0 [2.52] Bottom 3 54.0 [2.13] 4 1.0 [ 0.04] 4 5 5 Dual Output 1 64.0*45.0*19.0 mm Case Size : Case Material : Plastic resin + Fiberglass Weight : 92 g Flammability : UL94V-0 2.52*1.77*0.75 inches 17.78 [0.70] 45.0 [1.77] Tolerance Millimeters Inches Pin X.X{0.5 X.XX{0.25 {0.1 X.XX{0.02 X.XXX{0.01 {0.004 REV:9 2008/10 MINMAX 4