Emerson Network Power EXQ60-48D05-3V3J 60 w high efficiency dc/dc converter Datasheet

EXQ60D Series
Dual positive output
DC/DC CONVERTERS
•
•
•
•
•
•
•
•
•
•
•
60 W High Efficiency DC/DC Converters
1
Two positive outputs
Output voltage tracking
High efficiency
Approved to EN60950 (TÜV Rheinland), UL/cUL1950
Operating baseplate temperature of -40 °C to +100 °C
Up to 100% load imbalance
Trim function
No minimum load
Complies with ETS 300 019-1-3/2-3
Fully compliant with ETS 300 386-1
Available RoHS compliant
The EXQ60 is a new high efficiency, open frame, isolated 60 Watt converter series in an industry
standard quarter-brick footprint. The EXQ60 delivers very high output current at low voltages, and
excellent useable power density for today's high end applications. The first two models in the series
feature an input voltage range of 33 V to 75 V and are available in output voltages of 5/3.3 V and
3.3/2.5 V. The output voltage on each model is adjustable from 90% to 110% of the nominal value.
Typical efficiencies for the models are 91% for the 5/3.3 V and 90% for the 3.3/2.5 V version. The
EXQ60 series also has a remote on/off capability. Overcurrent and overvoltage protection features are
included as standard. With full international safety approval including EN60950, (TÜV Rheinland) and
UL/cUL1950, the EXQ60 reduces compliance costs and time to market.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Voltage adjustability
Both outputs
±10%
Setpoint accuracy
Both outputs (See Note 1)
Output voltage
5/3.3 V
(over all line and
load conditions)
3.3/2.5 V
Minimum load
Both outputs
Ripple and noise
20 MHz bandwidth 60 mV pk-pk max.,
20 mV rms max.
Transient response
peak dev. settling time
50% to 75% and back
to 1.0%, no external cap.
4.75
3.20
3.18
2.39
Short circuit protection
V
V
V
V
<
<
<
<
±1% max.
Vo1
Vo2
Vo1
Vo2
<
<
<
<
5.23
3.43
3.48
2.60
V
V
V
V
0%
120/80 mV
100 µs
Both outputs
Tracking
Outputs track
start-up and shutdown
Radiated emissions
Immunity:
ESD air
ESD contact
Radiated field enclosure
Conducted (DC power)
Conducted (signal)
Input transients
Input voltage range
48 Vin nominal
Input current
No load
Remote OFF
UVLO turn ON voltage
UVLO turn OFF voltage
33-75 Vdc
60 mA max.
20 mA max.
33 V (typ)
30 V (typ)
Nominal line
Active high remote ON/OFF
Logic compatibility
ON
OFF
Level A
Level B
Level B
EN61000-4-2
8 kV (NP), 15 kV (RP)
EN61000-4-2
6 kV (NP), 8 kV (RP)
EN61000-4-3
10 V/m (NP)
EN61000-4-6
10 V (NP)
EN61000-4-6
10 V (NP)
ETS 300 132-2, ETR 283
Efficiency
Operational insulation
See table
Input/output
Input/baseplate
1500 Vdc
1500 Vdc
Input fuse
5 A slow blow
Fixed
400 kHz (5/3.3 V)
325 kHz (3.3/2.5 V)
Approvals and standards
(See Notes 2 and 3)
UL/cUL1950, EN60950
TÜV Rheinland
Weight
MTBF
8 ms (typ)
(See Note 4)
Open Collector ref. to -input
Open circuit or >4 Vdc
<1.2 Vdc
EN55022 with external filter
EN55022 with external filter
EN55022
GENERAL SPECIFICATIONS
Switching frequency
INPUT SPECIFICATIONS
Start-up time
ETS 300 386-1 table 5
Conducted emissions
45 g (1.6 oz)
Telcordia SR-332
@ 25 °C, 100% load
ground benign
3,080,891 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating baseplate -40 °C to +100 °C
temperature
Non-operating
-40 °C to +125 °C
File Name: exq60d.pdf Rev: 29 Mar 2006
EXQ60D Series
Dual positive output
DC/DC CONVERTERS
60 W High Efficiency DC/DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
INPUT
VOLTAGE
OUTPUT VOLTAGE
OP1
OP2
OUTPUT CURRENT
1
2
1
OVP
2
TYPICAL
EFFICIENCY
MODEL
NUMBER (4,5,6)
33-75 Vdc
5V
3.3 V
12 A
15 A
5.9 V
4.0 V
91.5%
EXQ60-48D05-3V3J
33-75 Vdc
3.3 V
2.5 V
12 A
16 A
4.0 V
3.0 V
90.5%
EXQ60-48D3V3-2V5J
Notes
1
2
3
4
5
6
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
Io1 = 6 A, Io2 = 9 A
User must provide recommended fuses in order to comply with safety
approvals.
Maximum continuous output power.
60 Watts for D05-3V3 models
40 Watts for D3V3-2V5 models.
The EXQ60D features ‘Active High’ Remote ON/OFF as standard. An
‘Active Low’ Remote ON/OFF version is also available. To order the ‘Active
Low’ version of the EXQ60-48D05-3V3J please add the suffix ‘-R’ towards
the end of the part number, i.e. EXQ60-48D05-3V3-RJ. As our part
numbers cannot exceed 18 characters when ordering the ‘Active Low’
version of the EXQ60-48D3V3-2V5J please add the suffix ‘R’ towards the
end of the part number, i.e. EXQ60-48D3V3-2V5RJ.
When ordering 0.110" pin lengths designate with suffix ‘-K‘. If the product
is already a ‘-R’ suffix product then the suffix will be ‘-RK’.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
PIN CONNECTIONS
PIN NUMBER
FUNCTION
1
+Vin
2
Remote On/Off
3
-Vin
4
OP2
5
Output Return
6
Trim
7
OP1
2.000 [50.80]
0.950 [24.13]
3
0.600 [15.24]
2
0.250 [6.35]
0.000 [0.00]
1
Bottom View
Ø0.040 [Ø1.09]
(7 PLS)
0.50 [12.70]
4
5
6
7
0.975 [24.77]
0.725 [18.42]
0.475 [12.07]
0.225 [5.72]
0.000 [0.00]
M3 x 0.5 Threaded
Through (4 PLS)
2.300 [58.42]
1.200
[30.48]
1.500
[38.10]
Top View
0.150 [3.81]
International Safety Standard Approvals
UL/cUL : UL1950 File No. E135734
TÜV Rheinland Certificate No. 40013415
File No. 10401-3336-0208
CB Scheme No. DE1-32228
1.200 [30.48]
0.950 [24.13]
1
0.600 [15.24]
2
0.250 [6.35]
0.000 [0.00]
3
ALL DIMENSIONS IN INCHES [mm]
Ø0.128 [Ø3.25]
(4 PLS)
2.000 [50.80]
0.150 [3.81]
*0.145 [3.68]
*Standard available pin length.
0.110 (2.79) option also available.
See Note 5 for ordering details
7
6
5
4
0.975 [24.77]
0.725 [18.42]
0.475 [12.07]
0.225 [5.72]
0.000 [0.00]
Ø0.054 [Ø1.37]
(7 PLS)
Recommended Hole Pattern
Datasheet © Artesyn Technologies® 2006
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: 4 Application Note 4 Longform Data Sheet
www.artesyn.com
File Name: exq60d.pdf Rev: 29 Mar 2006