PAIRUI DNV40-2412 Dc converter Datasheet

DC-DC Converter
DIP-Package
DNV-40 SERIES, 40WATT, 2:1 INPUT RANGE
FEATURES:
3 years warranty
1500Vac isolation voltage
Six-side shielded metal case with low ripple and noise
Operating temperature range -40°C to +85°C
Over voltage, over current, short circuit protection
Remote on/off
Adjustable output voltage
Output voltage
(Vdc)
Output current
(A)
Efficiency
Typ.
5.1
8
86%
12.1
3.3
86%
DNV40-1213
15.1
2.67
89%
DNV40-2411
3.3
8
88%
DNV40-2412
12.1
3.3
90%
15.1
2.67
90%
DNV40-2414
24.2
1.67
89%
DNV40-2415
48.2
0.83
87%
DNV40-4811
5.1
8
90%
DNV40-4812
12.1
3.3
90%
15.1
2.67
90%
DNV40-4814
24.2
1.67
89%
DNV40-4815
48.2
0.83
87%
DNV40-11011
5.1
8
90%
12.1
3.3
90%
15.1
2.67
90%
24.2
1.67
89%
Model
Input voltage
(Vdc)
DNV40-1211
DNV40-1212
DNV40-2413
DNV40-4813
DNV40-11012
DNV40-11013
DNV40-11014
12(9~18)
24(18~36)
48(36~72)
110(66~160)
Notes:
1. Other input and output models may available on request;
2. You may request for the models with heatsink, plus “R” in the suffix, e.g. DNV40-1211R.
www.pairuigroup.com
Page:
1/4
Date: 12/18/2013
DC-DC Converter
DIP-Package
DNV-40 SERIES, 40WATT, 2:1 INPUT RANGE
ELECTRICAL
Input voltage range
Remote control
Input under voltage protection
12V
9-18Vdc
24V
18-36Vdc
48V
36-72Vdc
110V
60-166Vdc
REM left open
Output on
REM connect with -Vin
Output off
When input voltage is lower than the
low terminal input voltage
Auto-recovery
Output voltage accuracy
---
≤1%
Output voltage adjustable
---
±10% max.
Line regulation
Nominal Load, full voltage
±0.2% max.
Load regulation
20% ~ 100% rated load
±0.5% max.
Dynamic response
(transient/recovery time)
Ripple and noise
Isolation voltage
(<2mA/min)
5%-50%-75% load capability
20MHz BM, full load
∆Vo/∆t: ±5.0%/400μs
1% Vout max.
Input to output
1500Vac
Input to case
1500Vac
Output to case
500Vac
Isolation resistance
500Vdc
100MΩ
Temperature coefficient
---
Operating temperature range
Auxiliary heat sink
Storage temperature range
---
-45°C to +120°C
Over current protection
---
Auto-recovery
Short circuit protection
---
Continuous auto-recovery
Over voltage protection
---
Auto-recovery
Weight
---
60g
Relative humidity
---
10%-90% max.
MTBF
Bellcore TR-332, 25°C
±0.02%/°C max.
-40°C to +85°C
2x105Hrs
Notes: Unless otherwise specified, all the parameters of the test conditions are as follows: ambient temperature
25 , the nominal input voltage, pure resistive nominal load.
℃
www.pairuigroup.com
Page:
2/4
Date: 12/18/2013
DC-DC Converter
DIP-Package
DNV-40 SERIES, 40WATT, 2:1 INPUT RANGE
MECHANICAL
WITHOUT HEATSINK
WITH HEATSINK
PCB LAYOUT
CONNECTION
PIN #
SINGLE
1
+Vin
2
-Vin
4
REM
5
No Pin
6
+Vo
7
GND
8
ADJ
Note:
* Unit is mm(inch).
www.pairuigroup.com
Page:
3/4
Date: 12/18/2013
DC-DC Converter
DIP-Package
DNV-40 SERIES, 40WATT, 2:1 INPUT RANGE
TEMPERATURE PROFILE
CAPACITIVE LOADS SELECTION
Vout: 3.3V 5V
Vout: 12V 5V
Vout: 24V
Recommended
MAX.
Recommended
MAX.
Recommended
MAX.
value
value
value
value
value
value
4700μF
10000μF
1000μF
2200μF
470μF
1000μF
NOTES
RECOMMENDED TEST AND APPLICATION CIRCUIT
1. TVS&FUSE be helpful with over voltage protection and inrush limiting. Recommended FUSE better be 1.5~2times of
the rated current .
2. The input filter capacitor C6 could select the aluminum electrolytic capacitors or tantalum capacitors, and the
withstand voltage should be greater than the highest input voltage. Recommended capacitor should be between
22μF~100μF.
3. C1,C2 for the input filter capacitor,0.1~1μF high-frequency ceramics capacitor or chip capacitor are recommended. The
withstand voltage of output filter C5, C7 should be greater than the highest output voltage. Recommended capacitor of
C7 better within 100μF and C5 connected with the chip to reduce the input voltage peak, recommended 0.1~1μF
high-frequency ceramics capacitor or chip capacitor.
www.pairuigroup.com
Page:
4/4
Date: 12/18/2013