Astrodyne EFM-0312 30w ultraminiature open frame switching power supply Datasheet

EFM30
3 0 W U l t r a m i n i a t ure Open Frame Switching Power Supplies
series
Universal 90-264VAC Input
High Efficiency
Improved EMI Performance
3000V Isolation
Single, Dual and Triple Outputs
UL60950-1, EN60950-1
As Small as 2.36”W x 3.41”L x 0.93”H (Single Output)
Model Number
Output Voltage Output Amps (max)*2 Load Reg (max)
Ripple & Noise pk-pk Efficiency typ.
SINGLE OUTPUT
EFM-0300
EFM-0301
EFM-0302
EFM-0303
EFM-0305
EFM-0312
3.3 Volts(DC)
5 Volts(DC)
12 Volts(DC)
15 Volts(DC)
24 Volts(DC)
48 Volts(DC)
7.5Amps
6Amps
2.5Amps
2Amps
1.25Amps
0.63Amps
3%
2%
1%
1%
1%
1%
100mV typ.
70mV typ.
70mV typ.
70mV typ.
50mV typ.
50mV typ.
73%
78%
83%
84%
84%
85%
DUAL OUTPUT
EFM-0306
EFM-0307
EFM-0308
±12 Volts(DC)
±15 Volts(DC)
5/12 Volts(DC)
±1.25Amps
±1Amps
3/1.25Amps
±3%
±3%
±2%/ ±4%
±50mV typ.
±50mV typ.
±50mV typ.
80%
80%
74%
TRIPLE OUTPUT
EFM-0309
EFM-0311
5/±12 Volts(DC)
5/±15 Volts(DC)
3/±0.63Amps
3/±0.5Amps
0.6% / ±0.5%
0.6% / ±0.5%
100mV / ±75mV typ.
100mV / ±75mV typ.
74%
74%
* See Note section on page 3
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
EFM30
3 0 W U l t r a m i n i a t ure Open Frame Switching Power Supplies
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ:
series
GENERAL SPECIFICATIONS
90-264 VAC
47-63 Hz
30A@115V, 60A@230V Input *
Input-Out Isolation (1 min max.)
Efficiency
Switching Frequency
Safety
3KVAC
See Selection Chart
65Khz, (fixed, typical)
UL60950-1, EN60950-1
OUTPUT SPECIFICATIONS
Voltage and Current
See Selection Chart
Load Regulation *3
See Selection Chart
Line Regulation (LL-HL)
±1%, max. (Singles & Duals)
0.6 / ±0.2%, max. (Triples)
Cross Regulation Duals:
±2%. max. (0308: ±2 / ±6%)
Triples:
±3% max.
Preset Accuracy (FL,120VAC)
1% (0308: ±2 / ±5%)
1 / ±5%
DC Voltage Adjust (typ)
±10% of FS (Primary)
Temperature Coefficient
±0.03%/°C (0-50°C, typ)
Ripple/Noise *1, 4
See Selection Chart
Over Voltage Protection
Latching Auto Recovery *
Current Limit (auto recover)
>110% of FS, Power Limit
Short Circuit Protection
Latching Auto Recovery *
Hold Up Time
20 mS, typ
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNE.COM
PHYSICAL SPECIFICATIONS
Size
Singles:
Duals/Triples:
Construction
Weight
2.36” x 3.41” x 0.93”
2.36” x 3.94” x 0.93”
Open Frame
4.3oz (122g)
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature (Free Air)
Storage Temperature
Relative Humidity
EMC
-10 to +70°C with Derate
-25 to +71°C *
0 to + 95%, non-cond *
EN55022, class II
Notes:
1. All measurements should be made directly at the terminals of the
power supply
2. Minimum Load is NOT required for proper operation. However, auxiliary outputs should be reduced as a function of primary output minimum
load or load reugulation will be higher.
3. Load Regulation measured from 20% to full load. All other outputs at
nominal load.
4. Output noise measured directky at pins at nomimnal load with 0.1uF
and 10uF capacitors, pk-pk @ 20MHz bandwidth.
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
3 0 W U l t r a m i n i a t ure Open Frame Switching Power Supplies
EFM30
series
OUTPUT DERATING CURVE
MECHANICAL DIMENSIONS - Single
[ .76 ]
[ .93 ]
19.20
23.50
[ .17 ]
4.30
NO PIN
Dimensions are in millimeters [inches]
WWW.ASTRODYNE.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
EFM30
3 0 W U l t r a m i n i a t ure Open Frame Switching Power Supplies
series
MECHANICAL DIMENSIONS - DUAL
Dimensions are in millimeters [inches]
PIN #
WWW.ASTRODYNE.COM
EFM-0306~0307
EFM-0308
1
2
ACL
ACN
ACL
ACN
3
- V out
RETURN
4
NO PIN
NO PIN
5
COMMON
+5 V out
6
+ V out
+12 V out
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
3 0 W U l t r a m i n i a t ure Open Frame Switching Power Supplies
EFM30
series
MECHANICAL DIMENSIONS - TRIPLE
Dimensions are in millimeters [inches]
WWW.ASTRODYNE.COM
PIN #
1
Function
ACL
2
ACN
3
- V out
4
NO PIN
5
+5 V RETURN
6
7
COMMON
+5 V
8
+ V out
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
Similar pages