UTC BTB12LL-8-C-TA3-T 12a triac Datasheet

UNISONIC TECHNOLOGIES CO., LTD
BTB12
Preliminary
TRIAC
12A TRIACS

DESCRIPTION
The UTC BTB12 is a 12A triacs which can be operated in 4
quadrants, it uses UTC’s advanced technology to provide customers
with high commutation performances.
The UTC BTB12 is suitable for AC switching application and phase
control application such as fan speed and temperature modulation
control, lighting control and static switching relay, either in through-hole
or surface-mount packages.

SYMBOL

ORDERING INFORMATION
Ordering Number
Lead Free
Halogen Free
BTB12L-x-x-TA3-T
BTB12G-x-x-TA3-T

TO-220
Pin Assignment
1
2
3
MT1 MT2
G
Packing
Tube
SENSITIVITY AND TYPE
PART NUMBER
B
C
◎: Available

Package
VOLTAGE
600V
◎
◎
800V
◎
◎
SENSITIVITY
TYPE
50mA
25mA
STANDARD
STANDARD
MARKING
www.unisonic.com.tw
Copyright © 2014 Unisonic Technologies Co., Ltd
1 of 3
QW-R401-043.c
BTB12

Preliminary
TRIAC
ABSOLUTE MAXIMUM RATINGS
PARAMETER
RMS On-State Current (Full Sine Wave)
Non Repetitive Surge Peak F=50 Hz
On-State Current (Full Cycle,
F=60 Hz
TJ initial=25°C)
TC=90°C
SYMBOL
IT(RMS)
t=20ms
ITSM
t=16.7ms
2
RATINGS
12
UNIT
A
120
A
126
A
2
A2s
I t Value for Fusing
tP=10ms
It
78
Critical Rate of Rise of
On-State Current IG=2xIGT,
F=120 Hz TJ=125°C
dI/dt
50
tr≤100ns
Non Repetitive Surge Peak
tP=10ms
TJ=25°C
VDSM/VRSM
VDRM/VRRM+100
Off-State Voltage
Peak Gate Current
tP=20µs
TJ=125°C
IGM
4
Average Gate Power Dissipation
TJ=125°C
PG(AV)
1
Operating Junction Temperature
TJ
-40~+125
Storage Junction Temperature
TSTG
-40~+150
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.

V
A
W
°C
°C
THERMAL RESISTANCES
PARAMETER
Junction to Ambient
Junction to Case (AC)

A/µs
SYMBOL
θJA
θJC
RATINGS
60
1.4
UNIT
°C/W
°C/W
ELECTRICAL CHARACTERISTICS (TJ =25°C unless otherwise specified)
FOR STANDARD TYPE (4 QUADRANTS)
PARAMETER
SYMBOL
Gate Trigger Current
(Note 1)
Gate Trigger Voltage
VGT
Gate Non-Trigger Voltage
VGD
IGT
TEST CONDITIONS
VD=12V, RL=33Ω
I-II-III
IV
ALL
VD=VDRM, RL=3.3kΩ,
TJ=125°C
ALL
Holding Current
(Note 2)
IH
IT=500mA
Latching Current
IL
IG=1.2 IGT
Critical Rate of Rise of
Off-State Voltage
(Note 2)
Critical Rate of Rise of
Off-State Voltage at
Commutation(Note 2)

dV/dt
(dV/dt)c
MIN
0.2
I-III-IV
II
VD=67%VDRM, Gate Open,
TJ=125°C
(dI/dt)c=5.3A/ms, TJ= 125°C
C
TYP MAX MIN
25
50
1.3
B
UNIT
TYP MAX
50
mA
100
mA
1.3
V
0.2
V
25
50
mA
40
80
50
100
mA
mA
200
400
V/µs
5
10
V/µs
STATIC CHARACTERISTICS
PARAMETER
Peak On-State Voltage(Note)
Threshold Voltage(Note)
Dynamic Resistance(Note)
SYMBOL
TEST CONDITIONS
VT
ITM=17A, tp=380μs
TJ=25°C
VTO
TJ=125°C
RD
TJ=125°C
IDRM
TJ=25°C
Repetitive Peak Off-State Current
VDRM=VRRM
IRRM
TJ=125°C
Notes: 1. Minimum IGT is guaranteed at 5% of IGT max.
2. For both polarities of MT2 referenced to MT1.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MIN
TYP
MAX UNIT
1.55
V
0.85
V
35
mΩ
5
μA
1
mA
2 of 3
QW-R401-043.c
BTB12
Preliminary
TRIAC
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 3
QW-R401-043.c
Similar pages