Mean Well CLG-150-24A 150w single output switching power supply Datasheet

CLG-150
150W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range (up to 280VAC)
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
Cooling by free air convection
OCP point adjustable through output cable or internal potential meter
Suitable for LED lighting and moving sign applications
IP65 design for indoor or outdoor installations
3 years warranty
F
110
SELV
EQUIVALENT
CLG-150-12 A
IP65
( for A,B type only )
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter.
B : IP65 rated. Constant current level adjustable through output cable. (Optional)
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
potential meter. (Optional)
SPECIFICATION
MODEL
DC VOLTAGE
CLG-150-12
CLG-150-15
CLG-150-20
CLG-150-24
CLG-150-30
CLG-150-36
CLG-150-48
12V
15V
20V
24V
30V
36V
48V
7.5 ~ 15V
10 ~ 20V
12 ~ 24V
18 ~ 36V
24 ~ 48V
4.2A
3.2A
CONSTANT CURRENT REGION Note.4 6 ~12V
OUTPUT
RATED CURRENT
11A
9.5A
7.5A
6.3A
15 ~ 30V
5A
RATED POWER
132W
142.5W
150W
151.2W
150W
151.2W
153.6W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
VOLTAGE ADJ. RANGE Note.6 9 ~ 13V
13 ~ 17V
17 ~ 22V
22 ~ 27V
26 ~ 32V
31 ~ 41V
40 ~ 56V
2.5 ~ 5A
2.1 ~ 4.2A
1.6 ~ 3.2A
Can be adjusted by internal potential meter or through output cable
CURRENT ADJ. RANGE
5.5 ~ 11A
3.15 ~ 6.3A
2.0%
2.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
3000ms, 80ms at full load
50ms / 230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5 90 ~ 280VAC
230VAC /115VAC
16ms / 115VAC at full load
127 ~ 396VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF 0.95/230VAC
EFFICIENCY (Typ.)
88%
AC CURRENT
INRUSH CURRENT(max.)
2A / 115VAC
1A / 230VAC
COLD START 65A/230VAC
PF 0.98/115VAC at full load and rated output voltage
88%
90%
90%
90%
LED-Load : CC-mode max. 105%
CV-mode max. 110%
Electronic-Load : CC-mode max. 110%
OVER CURRENT
Note.4
SHORT CIRCUIT
Note.8 Hiccup mode, recovers automatically after fault condition is removed
90%
CV-mode max. 105%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13.5 ~ 16V
OVER VOLTAGE
18 ~ 20V
23 ~ 27V
28 ~ 34V
33 ~ 36V
42 ~ 48V
57 ~ 65V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
100
OVER TEMPERATURE
WORKING TEMP.
89%
<2mA / 240VAC
LEAKAGE CURRENT
PROTECTION
3.75 ~ 7.5A
2.0%
SETUP, RISE TIME
INPUT
4.75 ~ 9.5A
VOLTAGE TOLERANCE Note.3
10
(RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
Note.7 -30 ~ +55
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
@ full load ; +70
@ 60% load
20 ~ 90% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50
)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1, EN61347-1, EN61347-2-13 approved, IP65 approved (for A,B type only)
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:1.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B
OTHERS
HARMONIC CURRENT
Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4KV), criteria A
303.7Khrs min. MIL-HDBK-217F (25 )
222*68*39mm (L*W*H)
1.0Kg; 12pcs/13Kg/0.49CUFT(CLG-150-A/B)
1Kg; 12pcs/13Kg/0.96CUFT(CLG-150-C)
DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Type A and type C only.
7. Please refer to derating curve.
8. Please refer to OLP characteristics.
File Name:CLG-150-SPEC 2008-12-23
CLG-150
150W Single Output Switching Power Supply
Mechanical Specification
Case No. 954A
series
Unit:mm
A Type:(CLG-150-_A)
222.2
198.2
12
9.4
9.6
Io ADJ.
300 20
34.2
300 20
+V(Red)
-V(Black)
68
AC/L(Brown)
AC/N(Blue)
FG (Greed/Yellow)
18AWG 3C
14AWG 2C
9.4
Vo ADJ.
38.75
4.2 4PL
IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter.
(Can access by removing the rubber stopper on the case.)
B Type:(CLG-150-_B)
222.2
198.2
12
9.6
9.4
300 20
14AWG 2C
34.2
AC/L(Brown)
AC/N(Blue)
FG (Greed/Yellow)
68
300 20
18AWG 2C
ADJ1(Blue)
ADJ2(White)
4.2 4PL
38.75
9.4
18AWG 3C
+V(Red)
-V(Black)
IP67 rated. Output constant current level can be adjusted through output cable by connecting a resistor between ADJ1 and ADJ2.
Reference resistance value for output current adjustment (Typical)
Resistance
Percentage of rated current
Open
Slightly > 100%
4.7K
100%
620
75%
82
50%
Short
Slightly < 50%
File Name:CLG-150-SPEC 2008-12-23
CLG-150
150W Single Output Switching Power Supply
series
C Type:(CLG-150-_C)
231.2
198.2
15.5
8.5
7
AC Input Terminal Pin No.
Assignment
68
1
2
O/P
Pin No.
1
2
3
Vo ADJ.
7
7.5 9.5
I/P
39
Io ADJ.
1
2
3
4.2 4PL
Assignment
FG
AC/N
AC/L
DC Output Terminal Pin No.
Assignment
38.75
Pin No.
1
2
Assignment
+V
-V
Output voltage and constant current level can be adjusted through internal potential meter.
(Can access by removing the rubber stopper on the case.)
Block Diagram
Fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
+V
-V
ADJ1
ADJ2
(B Type)
O.L.P.
FG
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
fosc : 100KHz
100
230VAC
100
90
80
230VAC
Input only
80
100VAC
70
LOAD (%)
LOAD (%)
60
40
20
-25
-30
-10
0
15
30
50 55 60
AMBIENT TEMPERATURE ( )
-30
70
(HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
280
INPUT VOLTAGE (V) 60Hz
start up possible for 230VAC input
File Name:CLG-150-SPEC 2008-12-23