ETC2 A50P200-4TI Semiconductor protection fus Datasheet

AMP-TRAP®–Form 101
A50P
SEMICONDUCTOR PROTECTION FUSES
A50P Amp-trap® Form 101 Semiconductor
Protection fuses were developed for DC drives,
uninterruptable power supplies and similar applications requiring better protection (lower l2t) and
superior reliability. The A50P is typically used for
replacement.
Features / Benefits
➤ Low l2t minimizes damage to protected components on
short circuit
➤ Controlled arc voltage reduces stress to circuit
components during fuse clearing
➤ Choice of mounting types helps in equipment design
Ratings
➤ AC: 10-1200A
500VAC, 100kA I.R.
Approvals
➤ UL Recognized
Component
➤ AC: UL Guide No.
JFHR2 (10-800A)
➤ DC: 35-1000A
450VDC, 79kA I.R.
L/R = 10ms
HIGHLIGHTS:
APPLICATIONS:
Very Fast Acting
➤ Current Limiting
2
➤ Low l t
➤ Indicator Options
Available
➤
➤
➤ DC: UL Guide No.
JFHR2 (35-800A)
* Contact technical services for applications data.
Protection of DC
drives, UPS and other
equipment of 500
volts or less
Catalog Numbering System
A 50 P 100 - 4 TI
Amp-trap® Fuse
A
Rated Volts - 500
Style
50
P
Amperes*
Mounting Types*
Ferrule
Blades, bolt-in
Single Pole Fuse Blocks for A50P Fuses
FUSE
AMPERE
RATING
10-30
35-60
70-200
225-600
MOUNTING
TYPE
FUSE BLOCK
CATALOG
NUMBER
1
70316
4
4
4
P243G
P243E
P266C
Integral Blown-Fuse
Indicator
Trigger Indicator
Trigger Actuator
* For ampere ratings and types
not listed, consult the factory.
D 16
100
1
4
TI
TA
AMP-TRAP®–Form 101
A50P
SEMICONDUCTOR PROTECTION FUSES
Standard Fuse Ampere Ratings, Catalog Numbers
AMPERE
RATING
CATALOG
NUMBER
OUTLINE
FIG.
AMPERE
RATING
CATALOG
NUMBER
OUTLINE
FIG.
AMPERE
RATING
CATALOG
NUMBER
OUTLINE
FIG.
10
15
20
25
30
35
40
50
60
70
80
90
100
100
125
125
125
150
150
A50P10-1
A50P15-1
A50P20-1
A50P25-1
A50P30--1
A50P35-4
A50P40-4
A50P50-4
A50P60-4
A50P70-4
A50P80-4
A50P90-4
A50P100-4
A50P100-4TI
A50P125-4
A50P125-4TA
A50P125-4TI
A50P150-4
A50P150-4TI
1
1
1
1
1
2
2
2
2
3
3
3
3
3
3
4
3
3
3
175
175
200
200
200
225
250
250
250
275
300
300
300
325
350
350
400
400
400
A50P175-4
A50P175-4TI
A50P200-4
A50P200-4TA
A50P200-4TI
A50P225-4
A50P250-4
A50P250-4TA
A50P250-4TI
A50P275-4
A50P300-4
A50P300-4TA
A50P300-4TI
A50P325-4
A50P350-4
A50P350-4TI
A50P400-4
A50P400-4TA
A50P400-4TI
3
3
3
4
3
3
3
4
3
3
3
4
3
3
3
3
3
4
3
450
450
500
500
600
600
600
700
700
700
800
800
800
900
1000
1000
1200
1200
A50P450-4
A50P450-4TI
A50P500-4
A50P500-4TI
A50P600-4
A50P600-4TA
A50P600-4TI
A50P700-4
A50P700-4TA
A50P700-4TI
A50P800-4
A50P800-4TA
A50P800-4TI
A50P900-4
A50P1000-4
A50P1000-4TI
A50P1200-4
A50P1200-4TI
3
3
3
3
3
4
3
5
6
5
5
6
5
3
3
3
3
3
D
For ampere ratings and styles not listed, call Technical Services.
Figure 1
Figure 4
Figure 3
Figure 2
Figure 5
Dimensions
OUTLINE
REF.
MOUNTING
TYPE
FIG.
A50P10 to 30
1
1
A50P35 to 60
1DS*
1
A50P35 to 60
4
2
A50P70 to 100
4
3
A50P125 to 200
4, 4TA**
3, 4**
A50P225 to 400
4, 4TA**
3, 4**
A50P450 to 600
4, 4TA**
3, 4**
A50P700 to 800
4, 4TA**
5, 6**
A50P900 to 1200
4
3
A
B
2.00
(50.8)
2.25
(57.2)
3.19
(81.0)
3.63
(92.2)
3.63
(92.2)
4.34
(110)
4.47
(114)
6.47
(164)
6.97
(177)
0.56
(14.2)
0.81
(20.6)
0.81
(20.6)
1.00
(25.4)
1.22
(31.0)
1.50
(38.1)
2.00
(50.8)
2.50
(63.5)
3.00
(76.2)
Figure 6
DIMENSIONS - INCHES (mm)
C
D
E
F
1.63
(41.4)
2.13
(54.1)
2.13
(54.1)
2.09
(53.1)
2.22
(56.4)
2.22
(56.4)
3.22
(81.8)
* Use with 60306J fuse block.
** Optional Trigger Actuator (TA)
*** Mounting hole is round, diameter F.
D 17
2.50
(63.5)
2.94
(74.7)
2.94
(74.7)
3.41
(86.6)
3.53
(89.7)
4.63
(118)
4.97
(126)
2.25
(57.2)
2.81
(71.4)
2.81
(71.4)
2.78
(70.6)
2.91
(73.9)
4.31
(109)
***
***
0.34
8.6)
0.31
(7.9)
0.31
(7.9)
0.41
(10.4)
0.41
(10.4)
0.53
(13.5)
0.63
(16.0)
G
H
0.72
(18.3)
0.75
(19.1)
1.00
(25.4)
1.00
(25.4)
1.50
(38.1)
2.00
(50.8)
2.38
(60.5)
0.13
(3.3)
0.13
(3.3)
0.19
(4.8)
0.25
(6.4)
0.25
(6.4)
0.38
(9.7)
0.44
(11.1)
Similar pages