Total Power NES-150-48 150w single output switching power supply Datasheet

NES-150
150W Single Output Switching Power Supply
Authorized Distributor: Total Power International, Inc.
Toll Free: 877-646-0900(US)
PH# (978)453-7272
series
www.total-power.com
Features :
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
High efficiency, long life and high reliability
2 years warranty
SPECIFICATION
MODEL
OUTPUT
NES-150-3.3
NES-150-5
NES-150-7.5
NES-150-9
NES-150-12
NES-150-15
NES-150-24
NES-150-48
DC VOLTAGE
3.3V
5V
7.5V
9V
12V
15V
24V
48V
RATED CURRENT
30A
26A
20A
16.7A
12.5A
10A
6.5A
3.3A
CURRENT RANGE
0 ~ 30A
0 ~ 26A
0 ~ 20A
0 ~ 16.7A
0 ~ 12.5A
0 ~ 10A
0 ~ 6.5A
0 ~ 3.3A
RATED POWER
99W
130W
150W
150W
150W
150W
156W
158.4W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
120mVp-p
120mVp-p
120mVp-p
120mVp-p
120mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V
2.0%
7.13 ~ 8.3V
8.55 ~ 9.9V
1.0%
11.4 ~ 13.5V
1.0%
14.25 ~ 16.5V 22.8 ~ 27.6V
3.2 ~ 3.5V
VOLTAGE TOLERANCE Note.3 3.0%
LINE REGULATION
INPUT
Note.4
0.5%
0.5%
LOAD REGULATION
Note.5
2.0%
1.0%
SETUP, RISE TIME
Note.7 800ms, 20ms/230VAC
0.5%
0.5%
0.5%
0.5%
0.5%
73%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
3A/115VAC
2A/230VAC
COLD START 45A/230VAC
20ms/115VAC at full load
78%
80%
254 ~ 373VDC
83%
83%
83%
86%
86%
<2mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.65V
5.75 ~ 6.75V 8.6 ~ 10.1V
10.4 ~ 12.2V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +60
55.2 ~ 62.4V
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
SAFETY STANDARDS
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, heavy industry level, criteria A
EMS IMMUNITY
DIMENSION
PACKING
NOTE
0.5%
1200ms, 30ms/115VAC at full load
EFFICIENCY (Typ.)
MTBF
OTHERS
0.5%
47 ~ 63Hz
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
(Note 6)
0.5%
FREQUENCY RANGE
WORKING TEMP.
EMC
0.5%
90 ~ 132VAC / 180 ~ 264VAC selected by switch
OVER VOLTAGE
1.0%
0.5%
24ms/230VAC
OVERLOAD
1.0%
0.5%
VOLTAGE RANGE
PROTECTION
45.6 ~ 52.8V
1.0%
0.5%
HOLD UP TIME (Typ.)
LEAKAGE CURRENT
SAFETY &
1.0%
433.3Khrs min. MIL-HDBK-217F (25
199*98*38mm (L*W*H)
0.7Kg; 30pcs/22Kg/1.24CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
NES-150
150W Single Output Switching Power Supply
Mechanical Specification
Case No. 902
series
Unit:mm
3.5
12
9
7
197
1
9.5
2
98
80
85.5
3
4
8.2
5
6
7
3.5
4-
+V ADJ.
M
3
120
57.5
4.5
199
190
Terminal Pin No. Assignment
3.5
38
3
28.5
3.5
3-M
18
18
9
9.5
6.5
Pin No.
1
2
3
Assignment
AC/L
AC/N
FG
Pin No.
Assignment
DC OUTPUT -V
4,5
6,7
DC OUTPUT +V
157
22
Block Diagram
fosc : 65KHz
230
115
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
POWER
SWITCHING
RECTIFIERS
&
FILTER
-V
DETECTION
CIRCUIT
FG
O.L.P.
+V
PWM
CONTROL
O.V.P.
Derating Curve
Static Characteristics
Ta=25
100
Others
100
85
80
3.3V,5V
55
7.5V,9V
LOAD (%)
LOAD (%)
60
70
40
20
-20
0
10
20
30
40
AMBIENT TEMPERATURE (
50
60
70 (HORIZONTAL)
40
25
90
180
100
200
)
Authorized Distributor: Total Power International, Inc.
110
220
115
230
125
250
132
264
INPUT VOLTAGE (VAC) 60Hz
Toll Free: 877-646-0900(US)
PH# (978)453-7272
www.total-power.com