HP HEDS9000 Two channel high resolution optical incremental encoder module Datasheet

Two Channel High Resolution
Optical Incremental Encoder
Modules
Technical Data
Features
• High Resolution: Up to 2048
Cycles per Revolution
• Up to 8192 Counts per
Revolution with 4X Decoding
• Two Channel Quadrature
Output
• Low Cost
• Easy to Mount
• No Signal Adjustment
Required
• Small Size
• -40°C to 100 °C Operating
Temperature
• TTL Compatible
• Single 5 V Supply
Description
The HEDS-9000 Options T and U
and the HEDS-9100 Options B
and J are high resolution two
channel rotary incremental
encoder modules. These options
are an extension of our popular
HEDS-9000 and HEDS-9100
series. When used with a codewheel, these modules detect
relative rotary position. The
HEDS-9200 Option 300 and 360
are high resolution linear encoder
modules. When used with a
HEDS-9000/9100/9200
Extended Resolution
Series
codestrip, these modules detect
relative linear position.
These modules consist of a lensed
Light Emitting Diode (LED)
source and detector IC enclosed
in a small C shaped plastic
package. Due to a highly
collimated light source and
unique photodetector array, these
modules provide a highly reliable
quadrature output.
The HEDS-9000 and HEDS-9100
are designed for use with
codewheels which have an optical
radius of 23.36 mm and 11 mm
respectively. The HEDS-9200 is
designed for use with a linear
codestrip.
These components produce a two
channel quadrature output which
can be accessed through five
0.025 inch square pins located on
0.1 inch centers.
The resolution of the HEDS-9000
Options T and U are 2000 and
2048 counts per revolution
respectively. The HEDS-9100
Options B and J are 1000 and
1024 counts per revolution
respectively. The HEDS-9200
Option 300 and 360 linear
encoder modules have resolutions
of 300 and 360 lines per inch.
Consult local Agilent sales
representatives for other
resolutions.
Note: Agilent Technologies
encoders are not recommended
for use in safety critical
applications. Eg. ABS braking
systems, power steering, life
support systems and critical care
medical equipment. Please
contact sales representative if
more clarification is needed.
ESD WARNING: NORMAL HANDLING PRECAUTIONS SHOULD BE TAKEN TO AVOID STATIC
DISCHARGE.
2
Block Diagram
Theory of Operation
The diagram shown on the following page is a block diagram of
the encoder module. As seen in
this block diagram, the module
contains a single LED as its light
source. The light is collimated
into a parallel beam by means of a
single polycarbonate lens located
directly over the LED. Opposite
the emitter is the integrated
detector circuit. This IC consists
of multiple sets of photodetectors
and the signal processing
circuitry necessary to produce the
digital waveforms.
The codewheel/codestrip passes
between the emitter and detector,
causing the light beam to be
interrupted by the pattern of
spaces and bars on the codewheel. The photodiodes which
detect these interruptions are
arranged in a pattern that
corresponds to the codewheel/
codestrip. These detectors are
also spaced such that a light
period on one pair of detectors
corresponds to a dark period on
the adjacent pair of detectors. The
photodiode outputs are then fed
Output Waveforms
through the signal processing
circuitry resulting in A, A, B, and
B. Comparators receive these
signals and produce the final
outputs for channels A and B. Due
to this integrated phasing
technique, the digital output of
channel A is in quadrature with
that of channel B (90 degrees out
of phase).
Definitions
Count (N): The number of bar
and window pairs or counts per
revolution (CPR) of the
codewheel.
1 cycle (C): 360 electrical degrees
(°e), 1 bar and window pair.
1 Shaft Rotation: 360 mechanical
degrees, N cycles.
Pulse Width (P): The number of
electrical degrees that an output
is high during 1 cycle. This value
is nominally 180°e or 1/2 cycle.
Pulse Width Error (∆ P): The
deviation, in electrical degrees of
the pulse width from its ideal
value of 180°e.
State Width (S): The number of
electrical degrees between a
transition in the output of channel
A and the neighboring transition
in the output of channel B. There
are 4 states per cycle, each
nominally 90°e.
State Width Error (∆ S): The
deviation, in electrical degrees, of
each state width from its ideal
value of 90°e.
Phase (φ ): The number of electrical degrees between the center
of the high state of channel A and
the center of the high state of
channel B. This value is nominally
90°e for quadrature output.
Phase Error (∆φ ): The deviation
of the phase from its ideal value
of 90°e.
Direction of Rotation: When the
codewheel rotates in the direction
of the arrow on top of the
module, channel A will lead
channel B. If the codewheel
rotates in the opposite direction,
channel B will lead channel A.
Optical Radius (Rop ): The distance from the codewheel’s center
of rotation to the optical center
(O.C.) of the encoder module.
3
Package Dimensions
5.1 (0.20)
DATE CODE
3.73 ± 0.05
(0.147 ± 0.002)
2.54
(0.100)
20.8
(0.82)
HEDS-9X00
11.7
(0.46)
YYXX
X00
ALIGNING RECESS
2.44/2.41 DIA.
1.85 (0.073)
(0.096/0.095)
2.16 (0.085)
8.64 (0.340)
DEEP
REF.
2.9
(0.11)
2.21
(0.087)
2.67 (0.105) DIA.
MOUNTING THRU
HOLE 2 PLACES
CL
2.44/2.41 X 2.79
(0.096/0.095 X 0.110)
2.16 (0.085) DEEP
17.27
(0.680)
20.96
(0.825)
OPTICAL
CENTER LINE
5.46 ± 0.10
(0.215 ± 0.004)
1.78 ± 0.10
(0.070 ± 0.004)
2.92 ± 0.10
(0.115 ± 0.004)
11.9
(0.47)
8.81
5.8
45° (0.23) (0.347)
ALIGNING RECESS
2.44/2.41 X 2.79
(0.096/0.095 X 0.110)
2.16 (0.085) DEEP
ALIGNING RECESS
2.44/2.41 DIA.
(0.096/0.095)
2.16 (0.085) DEEP
OPTICAL
CENTER
TYPICAL DIMENSIONS IN
MILLIMETERS AND (INCHES)
SIDE A
6.9 (0.27)
4.75 ± 0.10
(0.187 ± 0.004)
10.16
(0.400)
OPTICAL CENTER
GND
1.8
(0.07)
1.52 (0.060)
1.0 (0.04)
CH. B
VCC
CH. A
N.C.
GND
2.54 (0.100) TYP.
OPTION CODE
1.02 ± 0.10
(0.040 ± 0.004)
VCC
0.63 (0.025)
SQR. TYP.
8.6 (0.34)
5
4
3
2
1
26.67 (1.05)
15.2
(0.60)
4.11 (0.162)
6.35 (0.250) REF.
SIDE B
Absolute Maximum Ratings
Storage Temperature, TS ..................................................................... -40°C to 100°C
Operating Temperature, TA ................................................................ -40°C to 100°C
Supply Voltage, VCC ...................................................................................... -0.5 V to 7 V
Output Voltage, VO ........................................................................................ -0.5 V to VCC
Output Current per Channel, Iout ................................................. -1.0 mA to 5 mA
Recommended Operating Conditions
Parameter
Symbol
Min.
Temperature
TA
-40
Supply Voltage
VCC
4.5
Load Capacitance
Count Frequency
Shaft Axial Play
Typ.
Max.
Units
100
°C
5.5
Volts
CL
100
pF
3.3 kΩ pull-up resistor
f
100
kHz
Velocity (rpm) x N/60
± 0.125
± 0.005
mm
in.
5.0
Notes
Ripple < 100 mVp-p
Note: The module performance is guaranteed to 100 kHz but can operate at higher frequencies. For frequencies above 100 kHz it is
recommended that the load capacitance not exceed 25 pF and the pull up resistance not exceed 3.3 kΩ. For typical module performance
above 100 kHz please see derating curves.
4
Electrical Characteristics
Electrical Characteristics over Recommended Operating Range, typical at 25°C.
Parameter
Symbol
Min.
Typical
Max.
Units
Supply Current
ICC
30
57
85
mA
High Level Output Voltage
VOH
2.4
Low Level Output Voltage
VOL
0.4
Notes
Volts
IOH = -200 µA max.
Volts
IOL = 3.86 mA
Rise Time
tr
180
ns
Fall Time
tf
40
ns
CL = 25 pF
RL = 3.3 kΩ pull-up
Encoding Characteristics
Encoding Characteristics over Recommended Operating Range and Recommended Mounting Tolerances.
These Characteristics do not include codewheel/codestrip contribution. The Typical Values are averages over
the full rotation of the codewheel. For operation above 100 kHz, see frequency derating curves.
Description
Symbol
Typical
Maximum
Units
Pulse Width Error
∆P
5
45
°e
Logic State Width Error
∆S
3
45
°e
Phase Error
∆φ
2
15
°e
Note: Module mounted on tolerance circle of ± 0.13 mm (± 0.005 in.) radius referenced from module Side A aligning recess centers.
3.3 kΩ pull-up resistors used on all encoder module outputs.
5
Derating Curves over Extended Operating Frequencies (HEDS-9000/9100/9200
Extended Series)
Below are the derating curves for state, duty, phase and VOH over extended operating frequencies of up to
240 kHz (recommended maximum frequency is 100 kHz). The curves were derived using standard TTL load.
–40°C operation is not feasible above 160 kHz because VOH will drop below 2.4 V (the minmum TTL for logic
state high) beyond that frequency.
CHANGE IN PULSE WIDTH ERROR
(ELECTRICAL DEGREE)
-10
100°C
-20
25°C
-30
-40°C
-40
-50
120
140
160
180
200
220
CHANGE IN STATE WIDTH ERROR
(ELECTRICAL DEGREE)
50
0
40
-40°C
30
25°C
20
100°C
10
0
120
240
140
180
200
220
240
5
-5
100°C
25°C
-10
-40°C
140
160
180
200
FREQUENCY (kHz)
220
240
CHANGE IN VOH (VOLTS)
CHANGE IN PHASE ERROR
(ELECTRICAL DEGREE)
0
120
160
FREQUENCY (kHz)
FREQUENCY (kHz)
4
100°C
3
25°C
2
-40°C
1
0
120
140
160
180
200
FREQUENCY (kHz)
220
240
6
Gap Setting for Rotary
and Linear Modules
Gap is the distance between the
image side of the codewheel and
the detector surface of the module. This gap dimension must
always be met and codewheel
warp and shaft end play must stay
within this range. This dimension
is shown in Figure 1.
Mounting Considerations
for Rotary Modules
Figure 2 shows a mounting
tolerance requirement for proper
operation of the high resolution
rotary encoder modules. The
Aligning Recess Centers must be
located within a tolerance circle
of 0.13 mm (0.005 in.) radius
from the nominal locations. This
tolerance must be maintained
whether the module is mounted
with side A as the mounting plane
using aligning pins (see Figure 3),
or mounted with Side B as the
mounting plane using an
alignment tool.
Mounting with Aligning
Pins
SIDE B
SIDE A
)
(
)
+0.25
+0.010
3.56 -0.51 0.140 -0.020
NOTE 1
IMAGE SIDE OF CODEWHEEL/CODESTRIP
CODEWHEEL/CODESTRIP
NOTES: 1. THESE DIMENSIONS INCLUDE CODEWHEEL/CODESTRIP WARP AND SHAFT END PLAY.
2. DIMENSIONS IN MILLIMETERS AND (INCHES).
Figure 1. Module Gap Setting.
Figure 2. Rotary Module Mounting Tolerance.
The high resolution rotary
encoder modules can be mounted
using aligning pins on the motor
base. (Agilent does not provide
aligning pins.) For this configuration, Side A must be used as the
mounting plane. The Aligning
Recess Centers must be located
within the 0.13 mm (0.005 in.) R
Tolerance Circle as explained
above. Figure 3 shows the
necessary dimensions.
2 PLACES
NOTE 1
Mounting with
Alignment Tools
Agilent offers alignment tools for
mounting Agilent encoder
modules in conjunction with
Agilent codewheels, using side B
as the mounting plane. Please
refer to the Agilent codewheel
data sheet for more information.
(
+0.51
+0.020
6.63 -0.25 0.261 -0.010
NOTE 1
NOTE 1: RECOMMENDED MOUNTING SCREW TORQUE IS 4 KG-CM (3.5 IN-LBS).
Figure 3. Mounting Plane Side A.
7
Mounting Considerations for Linear Modules
Mounting Plane Side A
Mounting Plane Side B
8
Recommended Codewheel Characteristics
Parameter
Symbol
Minimum
Maximum
φw/φb
0.7
1.4
Window Length
Lw
1.8 (0.07)
Absolute Maximum
Codewheel Radius
Rc
Window/Bar Ratio
Units
Notes
mm (inch)
Rop
+
1.9
(0.075)
mm
(inch)
Includes eccentricity
errors
Recommended Codestrip Characteristics and Alignment
Codestrip design must take into consideration mounting as referenced to either side A or side B (see Figure 4).
Mounting as Referenced to Side A
Mounting as Referenced to Side B
Figure 4. Codestrip Design
STATIC CHARGE WARNING: LARGE STATIC CHARGE ON CODESTRIP MAY HARM MODULE.
PREVENT ACCUMULATION OF CHARGE.
Symbol
Mounting Ref.
Side A
Mounting Ref.
Side B
Window/Bar Ratio
Ww /Wb
0.7 min., 1.4 max.
0.7 min., 1.4 max.
Window Distance
L
La ≤ 0.51 (0.020)
Lb ≥ 3.23 (0.127)
mm (inch)
Window Edge to
Module Opt Center Line
S
0.90 (0.035) min.
0.90 (0.035) min.
mm (inch)
Parallelism
Module to Codestrip
α
1.3 max.
1.3 max.
deg.
Parameter
Units
Note: All parameters and equations must be satisfied over the full length of codestrip travel including maximum codestrip runout.
9
Connectors
Manufacturer
Part Number
Mounting Surface
AMP
103686-4
640442-5
Both
Side B
DuPont
65039-032 with 4825X-000 term.
Both
Agilent
HEDS-8902 with 4-wire leads
Side B (see Fig. 7)
Molex
2695 series with 2759 series term.
Side B
Figure 7. HEDS-8902 Connector.
10
Ordering Information
Two Channel Encoder Modules with a 23.36 mm Optical Radius
HEDS-9000 Option
0 0
*
Resolution
(Cycles/Rev)
T - 2000 CPR
U - 2048 CPR
Two Channel Encoder Modules with an 11.00 mm Optical Radius
HEDS-9100 Option
0 0
*
Resolution
(Cycles/Rev)
B - 1000 CPR
J - 1024 CPR
Two Channel Linear Encoder Module
HEDS-9200 Option
Resolution
(Cycles/Rev)
300 - 300 LPI
360 - 360 LPI
Note: For lower resolutions, please refer to HEDS-9000/9100 and
HEDS-9200 data sheets for detailed information.
*Codewheel Information
For information on matching codewheels and
accessories for use with Agilent rotary encoder
modules, please refer to the Agilent Codewheel Data
sheet HEDS-5120/6100, HEDG-5120/6120,
HEDM-5120/6120.
www.agilent.com/semiconductors
For product information and a complete list of
distributors, please go to our web site.
For technical assistance call:
Americas/Canada: +1 (800) 235-0312 or
(408) 654-8675
Europe: +49 (0) 6441 92460
China: 10800 650 0017
Hong Kong: (+65) 6271 2451
India, Australia, New Zealand: (+65) 6271 2394
Japan: (+81 3) 3335-8152(Domestic/International), or 0120-61-1280(Domestic Only)
Korea: (+65) 6271 2194
Malaysia, Singapore: (+65) 6271 2054
Taiwan: (+65) 6271 2654
Data subject to change.
Copyright © 2002 Agilent Technologies, Inc.
Obsoletes 5988-5855EN
May 8, 2002
5988-6710EN
Similar pages