Ferroxcube CLI-RM12 Dimensions for product: rm12/ilp Datasheet

Product specifications
Core
RM12/ILP
Effective parameters
Symbol
Parameter
Value
Unit
∑(I/A)
core factor (C1)
0.28
mm⁻¹
Ve
effective volume
6200
mm³
Le
effective length
42
mm
Ae
effective area
148
mm²
Amin
minimum area
125
mm²
m
RM12/ILP
≈ 35
g/set
Dimensions for product: RM12/ILP
Symbol
Nom
Tol +
Tol -
Max
Min
Unit
A
29.80
0.00
1.10
29.80
28.70
mm
B
5.00
5.00
5.00
mm
C
16.10
0.00
0.50
16.10
15.60
mm
D2
25.00
1.00
0.00
26.00
25.00
mm
D3
12.80
0.00
0.40
12.80
12.40
mm
12.90
mm
E
G
37.40
0.00
1.30
37.40
36.10
mm
H1
16.80
0.00
0.20
16.80
16.60
mm
H2
9.00
0.50
0.00
9.50
9.00
mm
H3
13.80
0.25
0.25
14.05
13.55
mm
Inductance factor
Material
Value
Tol +
Tol -
Unit
3C94
7100
25%
25%
nH/turns²
3C95
8470
25%
25%
nH/turns²
3C96
6700
25%
25%
nH/turns²
3F36
4700
25%
25%
nH/turns²
3F4
3600
25%
25%
nH/turns²
Power loss: 3C94
Measuring conditions
100 kHz
200 mT
Max
100 ºC
3.100
Unit
W/set
Power loss: 3C95
Measuring conditions
Max
Unit
2016
Product specifications
Core
RM12/ILP
Power loss: 3C95
Measuring conditions
Max
Unit
100 kHz
200 mT
100 ºC
3.000
W/set
100 kHz
200 mT
25 ºC
3.200
W/set
Power loss: 3C96
Measuring conditions
Max
Unit
100 kHz
200 mT
100 ºC
2.800
W/set
400 kHz
50 mT
100 ºC
1.100
W/set
Power loss: 3F36
Measuring conditions
Max
Unit
500 kHz
50 mT
100 ºC
0.930
W/set
500 kHz
100 mT
100 ºC
7.100
W/set
Power loss: 3F4
Measuring conditions
Max
Unit
1000 kHz
30 mT
100 ºC
1.900
W/set
3000 kHz
10 mT
100 ºC
3.100
W/set
Bsat
Measuring conditions
Material
Min
Unit
25 kHz
250 A/m
100 ºC
3C94
320
mT
25 kHz
250 A/m
100 ºC
3C95
330
mT
25 kHz
250 A/m
100 ºC
3C96
340
mT
25 kHz
250 A/m
100 ºC
3F36
340
mT
25 kHz
250 A/m
100 ºC
3F4
330
mT
Accessories
Ordering name
CLI-RM12/ILP
Description
Clip
Ordering code
432202107251
2016