Power-One IAD012ZHH Iad series - dual output, 12 watt Datasheet

(888) IPD-CONVerters ● (888) 473-2668
●
www.ipdconverters.com
IAD SERIES - DUAL OUTPUT, 12 WATT
DESCRIPTION
FEATURES
IAD dual output DC/DC converters provide up to 12
Watts of output power in an industry standard package
and footprint. With a maximum case temperature of
100°C, the IAD is well suited for the most demanding
applications. The IAD features 1500 VDC isolation,
short circuit, and overtemperature protection, as well as
six-sided shielding. The IAD is available with optional
enable and voltage trim pins. Please see the IAS series for
single output applications.
• Industry Standard
Package
• Industry Standard
Footprint
• Fixed Frequency Design
• 100°C Case Operation
• Optional Trim and
Enable
• Wide Range Input
• 1500V Isolation
• Short Circuit Protection
TECHNICAL SPECIFICATIONS
Input
Voltage Range
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
Input Reverse Voltage Protection
18 - 36 VDC
34 - 75 VDC
25 mA
Shunt Diode
Efficiency vs. Load (48V Input)
Output
±1%
5%
0.5% V out
1.0% V out
10 % Iout Rated
25% Iout
4% Vout
500 µs
±10%
Hiccup
110 - 150%
85
80
EFFICIENCY %
Setpoint Accuracy
Auxillary Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., Vin Nom.
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
Power Limit Threshold Range
90
75
70
EFF. IAD010ZGG
EFF. IAD012ZHH
65
EFF. IAD012ZJJ
60
55
50
10
20
30
40
50
60
70
80
90
100
LOAD %
General
Turn-On Time
Remote Shutdown
Switching Frequency
Isolation
Input - Output
Output - Case (for 48 Vin)
Input - Case (for 24 Vin)
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
MTBF† (Bellcore TR-NWT-000332)
Safety
Weight (Approx.)
300 ms
Positive Logic
400 kHz
1500 VDC
500 VDC
1050 VDC
±0.03%/°C
-40 To +85°C
-40 To +110°C
95%
5 g, 10 - 55 Hz
1.8 X 106 hrs
UL, CUL, VDE
1.2 oz
C-70
Notes
†
††
MTBF predictions may vary slightly from model to model.
Industrial temp range available
Specifications typically at 25°C, normal line, and full load, unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Units are water-washable and fully compatible with commercial spray or immersion
post wave-solder washing equipment.
IAD SERIES - DUAL OUTPUT, 12 WATT
MODELS - (See the last page of this file for options.)
Vin
(Volts)
Vin Range
(Volts)
Iin Max.*
(Amps)
Vout
(Volts)
Iout Rated
(Amps)
Ripple & Noise
Pk-Pk (mV)
Efficiency
Typ. **
Model
24
24
24
48
48
48
18 - 36
18 - 36
18 - 36
34 - 75
34 - 75
34 - 75
0.80
0.85
0.85
0.40
0.43
0.42
±5
±12
±15
±5
±12
±15
±1.0
±0.5
±0.4
±1.0
±0.5
±0.4
75
120
150
75
120
150
77%
82%
83%
78%
82%
83%
IAD010YGG †
IAD012YHH
IAD012YJJ †
IAD010ZGG
IAD012ZHH
IAD012ZJJ
† Denotes advanced product release. Consult factory for product availability.
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
MECHANICAL DRAWING
1.00"
(25.4mm)
0.18" MIN.
(4.6mm)
BOTTOM VIEW
0
4
5
6
DIA 0.040"
(1.0mm)
2.00"
(50.8mm)
1
0.800"(20.3mm)
3
2
1.40"(35.6mm)
0.42"
(10.7mm)
0.900"
(22.9mm)
0
0.300"
(7.6mm)
0.800"
(20.3mm)
0.500"
(12.7mm)
0.400"
(10.2mm)
Thermal Impedance
Natural Convection
100 LFM
200 LFM
300 LFM
400 LFM
15.4
12.2
9.3
7.4
6.4
°C/W
°C/W
°C/W
°C/W
°C/W
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated
for specific application.
Pin
Tolerances
Function
1
2
3
+Vin
-Vin
Optional
Shutdown
+V out
Common
-V out
4
5
6
Inches:
.XX ± 0.020
.XXX ± 0.010
(Millimeters)
.X ± 0.5
.XX ± 0.25
Pin:
± 0.002
± 0.05
Case:
+ 0.04, - 0.00
+ 1.0, - 0.0
(Tolerances as listed unless otherwise specified.)
C-71
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION
SUFFIX
APPLICABLE SERIES
Negative Logic
N
HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQD
Lucent Compatible Trim
T
HAS, HBD, HBS, HES, QBS, QES
Terminal Strip
TS
REMARKS
TTL “Low” Turns Module ON
TTL “High” Turns Module OFF
XWS, XWD, XWT
Trim
1
IAS, LES
Enable
2
IAD, IAS, LES, SMS
Trim and Enable
3
IAS, LES
Current Share
4
SMS
Headerless
Y
Encapsulated EWS, IWS, OWS
PIN LENGTH AND HEATSINK
OPTIONS
Standard Pin Length is 0.180”
(4.6mm)
0.110” (2.8mm) Pin Length
8
All Units (Except SMS)
0.150” (3.8mm) Pin Length
9
All Units (Except SMS)
0.24” (6.1mm) Horizontal Heatsink
1H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.24” (6.1mm) Vertical Heatsink
1V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.45” (11.4mm) Horizontal
Heatsink
2H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.45” (11.4mm) Vertical Heatsink
2V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.95” (24.1mm) Horizontal
Heatsink
3H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.95” (24.1mm) Vertical Heatsink
3V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
C105
Similar pages