Newhaven M0220MD-202MDAR1-3 Dotâ matrix character vacuum fluorescent display module Datasheet

M0220MD‐202MDAR1‐3
Dot‐matrix Character Vacuum Fluorescent Display Module
M‐
0220‐
M‐
D‐
202MDA‐
R‐
1‐3
VFD Module
2 lines x 20 characters
Model
Dot‐Matrix
Character size = 3.68mm x 8.78mm
RoHS Compliant
Parallel interface (M6800)
Newhaven Display International, Inc.
2511 Technology Drive, Suite 101
Elgin IL, 60124
Ph: 847‐844‐8795
Fax: 847‐844‐8796
www.newhavendisplay.com
[email protected]
[email protected]
Document Revision History
Revision
0
1
2
Date
3/21/2005
9/21/2009
12/4/2009
Description
Initial Release
Updated Driver version, modified vf glass pins
Reduce pixel size to increase brightness and lifetime
Functions and Features
•
•
•
•
•
•
2 lines x 20 characters
Built‐in controller
Built‐in VF AC power supply
5.0V power supply
5x8 dots with cursor
Parallel interface (Serial interface selectable by jumpers)
Changed by
CL
CL
Mechanical Drawing
Pattern Detail
Pin Description (parallel interface)
Pin No.
Symbol
1
2
3
4
5
6
7‐10
VSS
VDD
NC (/RST)
RS
R/W
E
DB0 – DB3
11‐14
DB4 – DB7
External
Connection
Power Supply
Power Supply
‐ (MPU)
MPU
MPU
MPU
MPU
MPU
Function Description
Ground
Power supply for logic (+5.0V)
No Connect (if JP2 is short, PIN3 = Active LOW reset signal)
Register select signal RS=1: DATA RS=0: COMMAND
Read/Write select signal RW=1: READ RW=0: WRITE
Operation enable signal Falling Edge Triggered
Four low order bi‐directional three‐state data bus lines.
These four are not used during 4‐bit operation
Four high order bi‐directional three‐state data bus lines.
Recommended LCD connector: 2.54mm pitch pins
Pin Description (optional serial interface)
Pin No.
1
2
3
4
5
6
7‐14
Symbol
VSS
VDD
SI/SO
STB
NC
SCK
NC
External
Connection
Power Supply
Power Supply
MPU
MPU
‐
MPU
‐
Function Description
Ground
Power supply for logic (+5.0V)
Serial Data In, data out
Serial Strobe signal
No Connect
Serial Clock signal
No Connect
Recommended LCD connector: 2.54mm pitch pins
Jumper Settings (Default Parallel M68 mode)
Mode
JP2
JP3
JP4
JP5
JP6
JP7
Serial
Open
Short
Open
Short
Open
Short
Parallel (I80)
*1
Open
Short
Open
Open
Short
Parallel (M68)
*1
Open
Short
Open
Short
Open
*1) JP2 short enables PIN3 as external reset. JP2 open disables reset.
Block Diagram
Electrical Characteristics
Item
Operating Temperature Range
Storage Temperature Range
Operating Humidity
Storage Humidity
Vibration
Shock
Supply Voltage
Supply Current (*Note)
Luminance
“H” Level input
“L” Level input
“H” Level output
“L” Level output
Symbol
Vop
Vst
Hop
Hst
VDD
IDD
L
Vih
Vil
Voh
Vol
Condition
10~55Hz
Ta=25°C
VDD=5.0V
Min.
-40
-50
0
0
4.5
-
Typ.
5.0
290
Max.
+85
+95
85
90
4
40
5.5
435
Unit
⁰C
⁰C
%
%
G
G
V
mA
350
2.2
0
2.4
-
500
-
VDD
0.6
0.4
cd/m2
V
V
V
V
*Note: In-rush current can be approx 10 times the specified supply current at power up.
Power-on Timing
Controller Information
Built-in PT6314 controller. Download specification at http://www.newhavendisplay.com/app_notes/PT6314.pdf
Table of Commands
M68 Parallel Interface:
The PT6314 can interface with the CPU in 4‐bits or 8‐bits. Note that the internal registers are composed of 8 bits. During data
transfer in 4‐bit mode, DB4‐DB7 performs the data transfer operation two times, DB0‐DB3 should be tied HIGH or LOW.
4‐bit Data Transfer (M68):
8‐bit Data Transfer (M68):
Built‐in Font Table
Example Initialization after Power ON
Quality Information
Test Item
Content of Test
High Temperature storage
Endurance test applying the high
storage temperature for a long time.
Endurance test applying the low storage
temperature for a long time.
Endurance test applying the electric stress
(voltage & current) and the high thermal
stress for a long time.
Endurance test applying the electric stress
(voltage & current) and the low thermal
stress for a long time.
Endurance test applying the electric stress
(voltage & current) and the high thermal
with high humidity stress for a long time.
Endurance test applying the electric stress
(voltage & current) during a cycle of low
and high thermal stress.
Endurance test applying vibration to
simulate transportation and use.
Low Temperature storage
High Temperature
Operation
Low Temperature
Operation
High Temperature /
Humidity Operation
Thermal Shock resistance
Vibration test
Static electricity test
Endurance test applying electric static
discharge.
Test Condition
2
‐30⁰C , 48hrs
1,2
+70⁰C 48hrs
2
‐20⁰C , 48hrs
1,2
+40⁰C , 90% RH , 48hrs
1,2
0⁰C,30min ‐> +25⁰C,5min ‐>
+50⁰C,30min = 1 cycle
10 cycles
10‐55Hz , 15mm amplitude.
60 sec in each of 3 directions
X,Y,Z
For 15 minutes
VS=800V, RS=1.5kΩ, CS=100pF
One time
Note 1: No condensation to be observed.
Note 2: Conducted after 4 hours of storage at 25⁰C, 0%RH.
Note 3: Test performed on product itself, not inside a container.
Precautions for using LCDs/LCMs
See Precautions at www.newhavendisplay.com/specs/precautions.pdf
Warranty Information and Terms & Conditions
http://www.newhavendisplay.com/index.php?main_page=terms
Note
+80⁰C , 48hrs
3
Similar pages