MBRB20..CTPbF/MBR20..CT-1PbF Vishay High Power Products Schottky Rectifier, 2 x 10 A FEATURES MBR20..CT-1PbF MBRB20..CTPbF • 150 °C TJ operation Available • Low forward voltage drop RoHS* • High frequency operation Base common cathode 2 Base common cathode 2 COMPLIANT • Center tap D2PAK and TO-262 packages • High purity, high temperature epoxy encapsulation for enhanced mechanical strength and moisture resistance • Guard ring for enhanced ruggedness and long term reliability • Lead (Pb)-free 2 1 Common 3 Anode cathode Anode 2 1 Common 3 Anode cathode Anode D2PAK TO-262 • Designed and qualified for Q101 level DESCRIPTION This center tap Schottky rectifier has been optimized for low reverse leakage at high temperature. The proprietary barrier technology allows for reliable operation up to 150 °C junction temperature. Typical applications are in switching power supplies, converters, freewheeling diodes, and reverse battery protection. PRODUCT SUMMARY IF(AV) 2 x 10 A VR 80 to 100 V MAJOR RATINGS AND CHARACTERISTICS SYMBOL CHARACTERISTICS VALUES IF(AV) Rectangular waveform (per device) 20 IFRM TC = 133 °C (per leg) 20 VRRM IFSM tp = 5 µs sine VF 10 Apk, TJ = 125 °C TJ Range UNITS A 80 to 100 V 850 A 0.70 V - 65 to 150 °C VOLTAGE RATINGS PARAMETER SYMBOL Maximum DC reverse voltage VR Maximum working peak reverse voltage VRWM MBRB2080CTPbF MBR2080CT-1PbF MBRB2090CTPbF MBR2090CT-1PbF MBRB20100CTPbF MBR20100CT-1PbF UNITS 80 90 100 V ABSOLUTE MAXIMUM RATINGS PARAMETER Maximum average forward current SYMBOL per leg per device Peak repetitive forward current per leg Non-repetitive peak surge current TEST CONDITIONS VALUES IF(AV) TC = 133 °C, rated VR IFRM Rated VR, square wave, 20 kHz, TC = 133 °C 20 5 µs sine or 3 µs rect. pulse 850 IFSM UNITS 10 20 Following any rated load ondition and with rated VRRM applied Surge applied at rated load conditions halfwave, single phase, 60 Hz 150 Peak repetitive reverse surge current IRRM 2.0 µs, 1.0 kHz 0.5 Non-repetitive avalanche energy per leg EAS TJ = 25 °C, IAS = 2 A, L = 12 mH 24 A mJ * Pb containing terminations are not RoHS compliant, exemptions may apply Document Number: 94306 Revision: 14-Aug-08 For technical questions, contact: [email protected] www.vishay.com 1 MBRB20..CTPbF/MBR20..CT-1PbF Vishay High Power Products Schottky Rectifier, 2 x 10 A ELECTRICAL SPECIFICATIONS PARAMETER SYMBOL TEST CONDITIONS 10 A Maximum forward voltage drop VFM (1) TJ = 25 °C 20 A 10 A TJ = 125 °C 20 A Maximum instantaneous reverse current IRM (1) Threshold voltage VF(TO) Forward slope resistance rt Maximum junction capacitance Typical series inductance CT LS Maximum voltage rate of change dV/dt TJ = 25 °C Rated DC voltage TJ = 125 °C TJ = TJ maximum VR = 5 VDC (test signal range 100 kHz to 1 MHz) 25 °C Measured from top of terminal to mounting plane Rated VR VALUES UNITS 0.80 0.95 0.70 V 0.85 0.10 6 mA 0.433 V 15.8 mΩ 400 pF 8.0 nH 10 000 V/µs VALUES UNITS Note (1) Pulse width < 300 µs, duty cycle < 2 % THERMAL - MECHANICAL SPECIFICATIONS PARAMETER SYMBOL TEST CONDITIONS Maximum junction temperature range TJ - 65 to 150 Maximum storage temperature range TStg - 65 to 175 Maximum thermal resistance, junction to case per leg RthJC DC operation 2.0 Typical thermal resistance, case to heatsink RthCS Mounting surface, smooth and greased 0.50 Maximum thermal resistance, junction to ambient RthJA DC operation Approximate weight Mounting torque Marking device www.vishay.com 2 minimum maximum Non-lubricated threads °C °C/W 50 2 g 0.07 oz. 6 (5) kgf · cm (lbf · in) 12 (10) Case style D2PAK MBRB20100CT Case style TO-262 MBR20100CT-1 For technical questions, contact: [email protected] Document Number: 94306 Revision: 14-Aug-08 MBRB20..CTPbF/MBR20..CT-1PbF Schottky Rectifier, 2 x 10 A Vishay High Power Products 100 TJ = 150 °C TJ = 125 °C TJ = 25 °C 10 1 0.2 IR - Reverse Current (mA) IF - Instantaneous Forward Current (A) 100 10 TJ = 150 °C 1 TJ = 125 °C TJ = 100 °C 0.1 TJ = 75 °C TJ = 50 °C 0.01 TJ = 25 °C 0.001 0.0001 0.4 0.6 0.8 1.0 1.2 1.4 1.6 0 1.8 20 40 60 80 100 VFM - Forward Voltage Drop (V) VR - Reverse Voltage (V) Fig. 1 - Maximum Forward Voltage Drop Characteristics (Per Leg) Fig. 2 - Typical Values of Reverse Current vs. Reverse Voltage (Per Leg) CT - Junction Capacitance (pF) 1000 TJ = 25 °C 100 10 0 20 40 60 80 100 VR - Reverse Voltage (V) ZthJC - Thermal Impedance (°C/W) Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage (Per Leg) 10 1 PDM t1 0.1 Single pulse (thermal resistance) 0.01 0.00001 0.0001 t2 D = 0.75 D = 0.50 D = 0.33 D = 0.25 D = 0.20 0.001 0.01 Notes: 1. Duty factor D = t1/t2 2. Peak TJ = PDM x ZthJC + TC 0.1 1 10 t1 - Rectangular Pulse Duration (s) Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics (Per Leg) Document Number: 94306 Revision: 14-Aug-08 For technical questions, contact: [email protected] www.vishay.com 3 MBRB20..CTPbF/MBR20..CT-1PbF 10 150 140 Average Power Loss (W) Allowable Case Temperature (°C) Vishay High Power Products Schottky Rectifier, 2 x 10 A DC 130 Square wave (D = 0.50) Rated VR applied 120 110 D = 0.20 D = 0.25 D = 0.33 D = 0.50 D = 0.75 8 RMS limit 6 4 DC 2 See note (1) 0 100 0 2 4 6 8 10 12 14 0 16 2 4 6 8 10 12 14 16 IF(AV) - Average Forward Current (A) Fig. 6 - Forward Power Loss Characteristics (Per Leg) IFSM - Non-Repetitive Surge Current (A) IF(AV) - Average Forward Current (A) Fig. 5 - Maximum Allowable Case Temperature vs. Average Forward Current (Per Leg) 1000 At any rated load condition and with rated VRRM applied following surge 100 10 100 1000 10 000 tp - Square Wave Pulse Duration (µs) Fig. 7 - Maximum Non-Repetitive Surge Current (Per Leg) Note (1) Formula used: T = T - (Pd + Pd C J REV) x RthJC; Pd = Forward power loss = IF(AV) x VFM at (IF(AV)/D) (see fig. 6); PdREV = Inverse power loss = VR1 x IR (1 - D); IR at VR1 = Rated VR www.vishay.com 4 For technical questions, contact: [email protected] Document Number: 94306 Revision: 14-Aug-08 MBRB20..CTPbF/MBR20..CT-1PbF Schottky Rectifier, 2 x 10 A Vishay High Power Products ORDERING INFORMATION TABLE Device code MBR B 20 100 CT -1 TRL P 1 2 3 4 5 6 7 8 1 - 2 - Essential part number B = D2PAK 6 None 3 - None = TO-262 6 = -1 Current rating (20 = 20 A) 4 - Voltage ratings 5 - CT = Essential part number 6 7 - None = D2PAK 2 = B -1 = TO-262 2 None 80 = 80 V 90 = 90 V 100 = 100 V None = Tube (50 pieces) TRL = Tape and reel (left oriented - for D2PAK only) TRR = Tape and reel (right oriented - for D2PAK only) 8 - None = Standard production PbF = Lead (Pb)-free (for TO-262 and D2PAK tube) P = Lead (Pb)-free (for D2PAK TRR and TRL) LINKS TO RELATED DOCUMENTS Dimensions http://www.vishay.com/doc?95014 Part marking information http://www.vishay.com/doc?95008 Packaging information http://www.vishay.com/doc?95032 Document Number: 94306 Revision: 14-Aug-08 For technical questions, contact: [email protected] www.vishay.com 5 Legal Disclaimer Notice Vishay Disclaimer All product specifications and data are subject to change without notice. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permitted by law. The product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein, which apply to these products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners. Document Number: 91000 Revision: 18-Jul-08 www.vishay.com 1