Littelfuse Lxx04R3 4 amp sensitive & standard triac Datasheet

Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Lxx04xx & Qxx04xx Series
RoHS
Description
4 Amp bi-directional solid state switch series is designed
for AC switching and phase control applications such as
motor speed and temperature modulation controls, lighting
controls, and static switching relays.
Sensitive type devices guarantee gate control in Quadrants
I & IV needed for digital control circuitry.
Standard type devices normally operate in Quadrants I & III
triggered from AC line.
Features & Benefits
• RoHS Compliant
Agency Approval
Agency
contact bounce that
create voltage transients
• Glass – passivated
junctions
Agency File Number
• Voltage capability up to
1000 V
L Package : E71639
• Surge capability up to
55 A
Main Features
Symbol
IT(RMS)
VDRM /VRRM
IGT (Q1)
Value
Unit
4
A
400 to 1000
V
3 to 25
mA
• Electrically isolated
“L-Package” is UL
Recognized for 2500Vrms
• Solid-state switching
eliminates arcing or
• No contacts to wear out
from reaction of switching
events
• Restricted (or limited) RFI
generation, depending on
activation point of
sine wave
• Requires only a small gate
activation pulse in each
half-cycle
Applications
Schematic Symbol
Typical applications are AC solid-state switches, power
tools, home/brown goods and white goods appliances.
MT2
Sensitive gate Triacs can be directly driven by
microprocessor or popular opto-couplers/isolators.
MT1
Internally constructed isolated packages are offered for
ease of heat sinking with highest isolation voltage.
G
Absolute Maximum Ratings — Sensitive Triacs (4 Quadrants)
Symbol
Parameter
RMS on-state current
(full sine wave)
IT(RMS)
ITSM
Non repetitive surge peak on-state current
(full cycle, TJ initial = 25°C)
I2t
I2t Value for fusing
Lxx04Ly
TC = 90°C
Lxx04Ry/Lxx04Vy/Lxx04Dy
TC = 95°C
Value
Unit
4
A
f = 50 Hz
t = 20 ms
33
f = 60 Hz
t = 16.7 ms
40
tp = 8.3 ms
A
6.6
A2s
50
A/μs
Critical rate of rise of on-state current
(IG = 50mA with ≤ 0.1μs rise time)
f = 120 Hz
TJ = 110°C
IGTM
Peak gate trigger current
tp ≤ 10 μs
TJ = 110°C
1.2
A
PG(AV)
Average gate power dissipation
TJ = 110°C
0.3
W
Storage temperature range
-40 to 150
°C
Operating junction temperature range
-40 to 110
°C
di/dt
Tstg
TJ
Note: xx = voltage, y = sensitivity
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/03/16
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Absolute Maximum Ratings — Standard Triacs
Symbol
Parameter
RMS on-state current
(full sine wave)
IT(RMS)
ITSM
Non repetitive surge peak on-state current
(full cycle, TJ initial = 25°C)
I2t
I2t Value for fusing
Qxx04Ly
TC = 105°C
Qxx04Ry/Qxx04Vy/Qxx04Dy
TC = 110°C
Value
Unit
4
A
f = 50 Hz
t = 20 ms
46
f = 60 Hz
t = 16.7 ms
55
tp = 8.3 ms
A
12.5
A2s
di/dt
Critical rate of rise of on-state current
(IG = 50mA with ≤ 0.1μs rise time)
f = 120 Hz
TJ = 125°C
50
A/μs
IGTM
Peak gate trigger current
tp ≤ 10 μs;
IGT ≤ IGTM
TJ = 125°C
1.2
A
PG(AV)
Average gate power dissipation
TJ = 125°C
0.3
W
Storage temperature range
-40 to 150
°C
Operating junction temperature range
-40 to 125
°C
Tstg
TJ
Note: xx = voltage, y = sensitivity
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — Sensitive Triac (4 Quadrants)
Symbol
Test Conditions
Quadrant
I – II – III
IGT
VD = 12V RL = 60 Ω
VGT
VD = 12V RL = 60 Ω
ALL
VGD
VD = VDRM RL = 3.3 kΩ TJ = 110°C
ALL
IH
dv/dt
(dv/dt)c
tgt
IV
IT = 100mA
MAX.
Lxx04x5
Lxx04x6
Lxx04x8
3
5
5
10
3
5
10
20
MAX.
1.3
MIN.
MAX.
400V
VD = VDRM Gate Open TJ = 100°C
Lxx04x3
TYP.
600V
Unit
mA
V
0.2
V
5
10
10
15
25
25
30
35
15
15
20
25
mA
V/μs
(di/dt)c = 2.16 A/ms TJ = 110°C
TYP.
0.5
1
1
1
V/μs
IG = 2 x IGT PW = 15μs IT = 5.6 A(pk)
TYP.
2.8
3.0
3.0
3.2
μs
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — Standard Triac
Symbol
Test Conditions
IGT
VD = 12V RL = 60 Ω
VGT
VD = 12V RL = 60 Ω
VGD
VD = VDRM RL = 3.3 kΩ TJ = 125°C
IH
IT = 200mA
Quadrant
VD = VDRM Gate Open TJ = 125°C
Unit
MAX.
10
25
IV
TYP.
25
50
I – II – III
MAX.
1.3
1.3
MIN.
0.2
0.2
V
MAX.
20
30
mA
40
75
30
50
ALL
600V
800V
VD = VDRM Gate Open TJ = 100°C
Qxx04x4
I – II – III
400V
dv/dt
Qxx04x3
MIN.
40
1000V
mA
V
V/μs
50
(dv/dt)c
(di/dt)c = 2.16 A/ms TJ = 125°C
TYP.
2
2
V/μs
tgt
IG = 2 x IGT PW = 15μs IT = 5.6 A(pk)
TYP.
2.5
3.0
μs
Note: xx = voltage, x = package
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/03/16
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Static Characteristics (TJ = 25°C, unless otherwise specified)
Symbol
Test Conditions
ITM = 5.6A tp = 380 µs
VTM
MAX.
Lxx04xy
IDRM
VDRM = VRRM
IRRM
MAX.
Qxx04xy
Value
Unit
1.60
V
TJ = 25°C
400-600V
5
μA
TJ = 110°C
400-600V
200
μA
TJ = 25°C
400-1000V
10
μA
TJ = 125°C
400-800V
2
TJ = 100°C
1000V
3
mA
Thermal Resistances
Symbol
Parameter
Junction to case (AC)
Rθ(J-C)
Junction to ambient
Rθ(J-A)
Value
L/Qxx04Dy
1.5
L/Qxx04Ly
3.5
L/Qxx04Ry
2.2
L/Qxx04Vy
1.5
L/Qxx04Ly
50
L/Qxx04Ry
45
L/Qxx04Vy
70
Unit
°C/W
°C/W
Note: xx = voltage, x = package, y = sensitivity
Figure 2: N
ormalized DC Gate Trigger Current for
All Quadrants vs. Junction Temperature
Figure 1: Definition of Quadrants
ALL POLARITIES ARE REFERENCED TO MT1
(+)
IGT
GATE
MT1
IGT
MT1
REF
IGT
GATE
(+)
+
IGT
MT2
2.0
1.0
IGT
GATE
-
MT2 NEGATIVE
(Negative Half Cycle)
MT1
REF
Additional Information
Datasheet
3.0
0.0
MT1
REF
REF
QII QI
QIII QIV
MT2
(-)
IGT
IGT
GATE
MT2
IGT (TJ = 25°C)
(-)
+
4.0
Ratio of
MT2
MT2 POSITIVE
(Positive Half Cycle)
Resources
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/03/16
Samples
-65
-40
-40
10
35
60
85
Junction Temperature (TJ)- ºC
110
125
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Figure 3: Normalized DC Holding Current
vs. Junction Temperature
Figure 4: N
ormalized DC Gate Trigger Voltage for
All Quadrants vs. Junction Temperature
2.0
VGT
2.0
VGT (TJ = 25°C)
3.0
1.5
1.0
Ratio of
IH
Ratio of
IH (TJ = 25°C)
4.0
1.0
0.5
0.0
0.0
-65
-40
-40
10
35
60
85
110
-65
125
-40
-40
Junction Temperature (TJ)- ºC
Figure 5: Power Dissipation (Typical)
vs. RMS On-State Current
35
125
Qxx04Ry
Qxx04Vy
Qxx04Dy
120
Maximum Allowable
Case Temperature (TC) - °C
CURRENT WAVE FORM: Sinusoidal
3.0
60
85
110
125
Figure 6: M
aximum Allowable Case Temperature
vs. On-State Current
4.0
Average On-State
Power Dissipation (PD(AV)) - Watts
10
Junction Temperature (TJ)- ºC
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
2.0
1.0
115
CURRENT WAVE FORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
CASE TEMPERATURE: Measured
as shown on Dimensional Drawing
110
Qxx04Ly
105
100
95
90
85
80
0.0
75
0.0
1.0
2.0
3.0
4.0
5.0
0
1
RMS On-State Current (IT(RMS)) - Amps
Figure 7: Maximum Allowable Case Temperature
vs. On-State Current
Lxx04Ry
Lxx04Vy
Lxx04Dy
Maximum Allowable
Case Temperature (TC) - °C
100
Lxx04Ly
95
3
4
5
6
Figure 8: Maximum Allowable Ambient Temperature
vs. On-State Current
120
CURRENT WAVE FORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
CASE TEMPERATURE: Measured
as shown on Dimensional Drawing
Maximum Allowable
Ambient Temperature (TA) - °C
110
105
2
RMS On-State Current (IT(RMS)) - Amps
90
85
80
75
70
CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 360°
FREE AIR RATING – NO HEATSINK
100
80
Qxx04Ly
Qxx04Ry
60
L/Qxx04Vy
40
Lxx04Ly
65
20
60
0
1
2
3
4
RMS On-State Current (IT(RMS)) - Amps
Note: xx = voltage, y = sensitivity
5
6
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RMS On-State Current [IT(RMS)] - Amps
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/03/16
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Figure 9: On-State Current vs. On-State Voltage (Typical)
20
TJ = 25°C
Positive or Instantaneous
On-State Current (IT) - Amps
18
16
14
12
10
8
6
4
2
0
0.6
0.8
1.0
1.2
1.4
1.6
1.8
Positive or Instantaneous
On-State Voltage (VT) - Volts
Figure 10: Surge Peak On-State Current vs. Number of Cycles
Peak Surge (Non-repetitive) On-State Current
(ITSM) – Amps
100
Supply Frequency: 60Hz Sinusoidal
Load: Resistive
RMS On-State [IT(RMS)]: Max Rated Value at
Specific Case Temperature
Qxx04Ry
Qxx04Ly
Qxx04Dy
Qxx04Vy
Notes:
1. G
ate control may be lost during and immediately
following surge current interval.
2. O
verload may not be repeated until junction
temperature has returned to steady-state
rated value.
Lxx04Ry
Lxx04Ly
Lxx04Dy
Lxx04Vy
10
1
1
10
100
Surge Current Duration – Full Cycles
Note: xx = voltage, y = sensitivity
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/03/16
1000
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Soldering Parameters
Pb – Free assembly
Pre Heat
- Temperature Min (Ts(min))
150°C
- Temperature Max (Ts(max))
200°C
- Time (min to max) (ts)
60 – 180 secs
Average ramp up rate (Liquidus Temp)
(TL) to peak
5°C/second max
TS(max) to TL - Ramp-up Rate
5°C/second max
Reflow
- Temperature (TL) (Liquidus)
217°C
- Temperature (tL)
60 – 150 seconds
Peak Temperature (TP)
260°C +0/-5
Time within 5°C of actual peak
Temperature (tp)
20 – 40 seconds
Ramp-down Rate
5°C/second max
Time 25°C to peak Temperature (TP)
8 minutes Max.
Do not exceed
280°C
Physical Specifications
Terminal Finish
100% Matte Tin-plated
Body Material
UL recognized epoxy meeting flammability
classification 94V-0
Terminal Material
Copper Alloy
tP
TP
Temperature
Reflow Condition
Ramp-up
TL
tL
TS(max)
Preheat
TS(min)
25
Ramp-do
Ramp-down
tS
time to peak temperature
Time
Environmental Specifications
Test
AC Blocking
Temperature Cycling
Temperature/
Humidity
Specifications and Conditions
MIL-STD-750, M-1040, Cond A Applied
Peak AC voltage @ 125°C for 1008 hours
MIL-STD-750, M-1051,
100 cycles; -40°C to +150°C; 15-min
dwell time
EIA / JEDEC, JESD22-A101
1008 hours; 320V - DC: 85°C; 85%
rel humidity
MIL-STD-750, M-1031,
1008 hours; 150°C
Design Considerations
High Temp Storage
Careful selection of the correct device for the application’s
operating parameters and environment will go a long way
toward extending the operating life of the Thyristor. Good
design practice should limit the maximum continuous
current through the main terminals to 75% of the device
rating. Other ways to ensure long life for a power discrete
semiconductor are proper heat sinking and selection of
voltage ratings for worst case conditions. Overheating,
overvoltage (including dv/dt), and surge currents are
the main killers of semiconductors. Correct mounting,
soldering, and forming of the leads also help protect
against component damage.
Low-Temp Storage
1008 hours; -40°C
Resistance to
Solder Heat
MIL-STD-750 Method 2031
Solderability
ANSI/J-STD-002, category 3, Test A
Lead Bend
MIL-STD-750, M-2036 Cond E
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/03/16
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Dimensions — TO-220AB (R-Package) — Non-Isolated Mounting Tab Common with Center Lead
TC MEASURING POINT
AREA (REF.) 0.17 IN2
O
A
E
Dimension
8.13
.320
P
MT2
B
C
13.36
.526
D
7.01
.276
NOTCH IN
GATE LEAD
TO ID.
NON-ISOLATED
TAB
F
R
G
L
H
K
N
J
Note: Maximum torque to
be applied to mounting tab
is 8 in-lbs. (0.904 Nm).
M
MT1 MT2 GATE
Inches
Millimeters
Min
Max
Min
Max
A
0.380
0.420
9.65
10.67
B
0.105
0.115
2.67
2.92
C
0.230
0.250
5.84
6.35
D
0.590
0.620
14.99
15.75
E
0.142
0.147
3.61
3.73
F
0.110
0.130
2.79
3.30
G
0.540
0.575
13.72
14.61
H
0.025
0.035
0.64
0.89
J
0.195
0.205
4.95
5.21
K
0.095
0.105
2.41
2.67
L
0.060
0.075
1.52
1.91
M
0.085
0.095
2.16
2.41
N
0.018
0.024
0.46
0.61
O
0.178
0.188
4.52
4.78
P
0.045
0.060
1.14
1.52
R
0.038
0.048
0.97
1.22
Min
Max
Min
Max
Dimensions — TO-220AB (L-Package) — Isolated Mounting Tab
TC MEASURING POINT
O
A
E
P
AREA (REF.) 0.17 IN2
Dimension
8.13
.320
B
C
13.36
.526
D
7.01
.276
F
R
G
L
H
K
Note: Maximum torque to
be applied to mounting tab
is 8 in-lbs. (0.904 Nm).
N
J
M
MT1 MT2 GATE
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/03/16
Inches
Millimeters
A
0.380
0.420
9.65
10.67
B
0.105
0.115
2.67
2.92
C
0.230
0.250
5.84
6.35
D
0.590
0.620
14.99
15.75
E
0.142
0.147
3.61
3.73
F
0.110
0.130
2.79
3.30
G
0.540
0.575
13.72
14.61
H
0.025
0.035
0.64
0.89
J
0.195
0.205
4.95
5.21
K
0.095
0.105
2.41
2.67
L
0.060
0.075
1.52
1.91
M
0.085
0.095
2.16
2.41
N
0.018
0.024
0.46
0.61
O
0.178
0.188
4.52
4.78
P
0.045
0.060
1.14
1.52
R
0.038
0.048
0.97
1.22
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Dimensions — TO-251AA (V-Package) — V-PAK Through Hole
TC MEASURING POINT
E
MT2
AREA: 0.040 IN2
H
D
Dimension
5.28
.208
J
A
5.34
.210
B
R
P
Q
S
K
C
MT1
L
F
MT2
GATE
G
I
Inches
Millimeters
Min
Typ
Max
Min
Typ
Max
A
0.037
0.040
0.043
0.94
1.01
1.09
B
0.235
0.242
0.245
5.97
6.15
6.22
C
0.350
0.361
0.375
8.89
9.18
9.53
D
0.205
0.208
0.213
5.21
5.29
5.41
E
0.255
0.262
0.265
6.48
6.66
6.73
F
0.027
0.031
0.033
0.69
0.80
0.84
G
0.087
0.090
0.093
2.21
2.28
2.36
H
0.085
0.092
0.095
2.16
2.34
2.41
I
0.176
0.180
0.184
4.47
4.57
4.67
J
0.018
0.020
0.023
0.46
0.51
0.58
K
0.035
0.037
0.039
0.90
0.95
1.00
L
0.018
0.020
0.023
0.46
0.52
0.58
P
0.042
0.047
0.052
1.06
1.20
1.32
Q
0.034
0.039
0.044
0.86
1.00
1.11
R
0.034
0.039
0.044
0.86
1.00
1.11
S
0.074
0.079
0.084
1.86
2.00
2.11
Dimensions — TO-252AA (D-Package) — D-PAK Surface Mount
MT2
E
D
6.71
.264
5.28
.208
TC MEASURING POINT
Dimension
6.71
.264
B
C
P
Q
MT1
GATE
F
MT2
1.60
.063
1.80
.071
AREA : 0.040 IN2
3
.118
G
I
O
L
K
M
N
J
H
4.60
.181
Millimeters
Min
Typ
Max
Min
Typ
Max
A
0.037
0.040
0.043
0.94
1.01
1.09
B
0.235
0.243
0.245
5.97
6.16
6.22
C
0.106
0.108
0.113
2.69
2.74
2.87
A
5.34
.210
Inches
D
0.205
0.208
0.213
5.21
5.29
5.41
E
0.255
0.262
0.265
6.48
6.65
6.73
F
0.027
0.031
0.033
0.69
0.80
0.84
G
0.087
0.090
0.093
2.21
2.28
2.36
H
0.085
0.092
0.095
2.16
2.33
2.41
I
0.176
0.179
0.184
4.47
4.55
4.67
J
0.018
0.020
0.023
0.46
0.51
0.58
K
0.035
0.037
0.039
0.90
0.95
1.00
L
0.018
0.020
0.023
0.46
0.51
0.58
M
0.000
0.000
0.004
0.00
0.00
0.10
N
0.021
0.026
0.027
0.53
0.67
0.69
O
0°
0°
5°
0°
0°
5°
P
0.042
0.047
0.052
1.06
1.20
1.32
Q
0.034
0.039
0.044
0.86
1.00
1.11
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/03/16
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Product Selector
Part Number
Voltage
Gate Sensitivity Quadrants
Type
Package
3 mA
Sensitive Triac
TO-220L
3 mA
3 mA
Sensitive Triac
TO-252 D-PAK
X
3mA
3mA
Sensitive Triac
TO-220R
X
X
3 mA
3 mA
Sensitive Triac
TO-251 V-PAK
Lxx04L5
X
X
5 mA
5 mA
Sensitive Triac
TO-220L
Lxx04D5
X
X
5 mA
5 mA
Sensitive Triac
TO-252 D-PAK
Lxx04R5
X
X
5mA
5mA
Sensitive Triac
TO-220R
Lxx04V5
X
X
5 mA
5 mA
Sensitive Triac
TO-251 V-PAK
Lxx04L6
X
X
5 mA
10 mA
Sensitive Triac
TO-220L
Lxx04D6
X
X
5 mA
10 mA
Sensitive Triac
TO-252 D-PAK
Lxx04R6
X
X
5mA
10mA
Sensitive Triac
TO-220R
Lxx04V6
X
X
5 mA
10 mA
Sensitive Triac
TO-251 V-PAK
Lxx04L8
X
X
10 mA
20 mA
Sensitive Triac
TO-220L
Lxx04D8
X
X
10 mA
20 mA
Sensitive Triac
TO-252 D-PAK
Lxx04R8
X
X
10mA
20mA
Sensitive Triac
TO-220R
Lxx04V8
X
X
10 mA
20 mA
Sensitive Triac
TO-251 V-PAK
Qxx04L3
X
X
10 mA
Standard Triac
TO-220L
Qxx04D3
X
X
10 mA
Standard Triac
TO-252 D-PAK
Qxx04V3
X
X
10 mA
Standard Triac
TO-251 V-PAK
Qxx04R3
X
X
10mA
Standard Triac
TO-220R
Qxx04L4
X
X
X
X
25 mA
Standard Triac
TO-220L
Qxx04D4
X
X
X
X
25 mA
Standard Triac
TO-252 D-PAK
Qxx04R4
X
X
X
X
25mA
Standard Triac
TO-220R
Qxx04V4
X
X
X
X
25 mA
Standard Triac
TO-251 V-PAK
400V
600V
Lxx04L3
X
Lxx04D3
800V
1000V
I – II – III
IV
X
3 mA
X
X
Lxx04R3
X
Lxx04V3
Packing Options
Part Number
Marking
Weight
Packing Mode
Base Quantity
L/Qxx04LyTP
L/Qxx04Ly
L/Qxx04DyRP
L/Qxx04Dy
2.2 g
Tube
500 (50 per tube)
0.3 g
Embossed Carrier
L/Qxx04DyTP
2500
L/Qxx04Dy
0.3 g
Tube Pack
750 (75 per tube)
L/Qxx04VyTP
L/Qxx04Vy
0.4 g
Tube Pack
750 (75 per tube)
Note: xx = Voltage; y = Sensitivity
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/03/16
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
TO-252 Embossed Carrier Reel Pack (RP) Specifications
Meets all EIA-481-2 Standards
* Cover tape
0.315
(8.0)
0.512 (13.0) Arbor
Hole Dia.
MT1
XXXXXX
DC
0.059
DIA
(1.5)
XX
DC
XX
XXXXXX
*
DC
0.524
(13.3)
XX
0.63
(16.0)
XXXXXX
Gate
XXXXXX
0.157
(4.0)
MT2
12.99
(330.0)
Dimensions
are in inches
(and millimeters).
0.64
(16.3)
Direction of Feed
Part Numbering System
Part Marking System
Q 60 04 L 4 xx
TO-251AA- (V Package)
TO-252AA- (D Package)
LEAD FORM DIMENSIONS
xx : Lead Form Option
DEVICE TYPE
L : Sensitive Triac
Q : Standard Triac
L6004V4
SENSITIVITY & TYPE
Sensitive Triac:
3 : 3 mA (QI, II, III, IV)
5 : 5 mA (QI, II, III, IV)
6 : 5 mA (QI, II, III)
10 mA (QIV)
8 : 10 mA (QI, II, III)
20 mA (QIV)
Standard Triac:
3 : 10 mA (QI, II, III)
4 : 25 mA (QI, II, III)
VOLTAGE RATING
40 : 400V
60 : 600V
80 : 800V
K0 : 1000V
CURRENT RATING
04 : 4A
PACKAGE TYPE
L :TO-220 Isolated
R :TO-220 Non-Isolated
V :TO-251 (V-Pak)
D :TO-252 (D-Pak)
YMLDD
L6004V4
YMLDD
®
®
Date Code Marking
Y:Year Code
M: Month Code
L: Location Code
DD: Calendar Code
TO-220 AB - (L and R Package)
Q6004R4
YM
®
®
Date Code Marking
Y:Year Code
M: Month Code
XXX: Lot Trace Code
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/03/16