Mean Well APC-35-500 Constant current mode power supply Datasheet

APC-35
35W Single Output Switching Power Supply
series
■ Features :
( only for APC-35-700)
SPECIFICATION
APC-35-350
APC-35-500
APC-35-700
APC-35-1050
RATED CURRENT
350mA
500mA
700mA
1050mA
DC VOLTAGE RANGE
RATED POWER
28~100V
35W
25~70V
35W
15~50V
35W
11~33V
34.7W
350mVp-p
350mVp-p
350mVp-p
84%
84%
MODEL
RIPPLE & NOISE (max.) Note.2 350mVp-p
OUTPUT
VOLTAGE TOLERANCE Note.3 ±5.0%
±8.0%
CURRENT ACCURACY
LINE REGULATION
±1.0%
LOAD REGULATION
±3.0%
SETUP, RISE TIME
1500ms, 40ms / 230VAC
HOLD UP TIME (Typ.)
20ms/230VAC
VOLTAGE RANGE
INPUT
Note.4
127 ~ 370VDC
EFFICIENCY(Typ.)
84%
AC CURRENT
INRUSH CURRENT(Typ.)
0.5A/230VAC;0.75A/115VAC
COLD START 45A(twidth=490μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
5 units (circuit breaker of type B) / 9 units (circuit breaker of type C) at 230VAC
84%
0.25mA / 240VAC
77 ~ 91V
110 ~ 130V
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-30 ~ 70℃(Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
55 ~ 65V
36 ~ 43V
-40 ~ +80℃, 10 ~ 95% RH
±0.2%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750 (only for APC-35-700&1050), CSA-C22.2 No. 250.0-13 (only for APC-35-1050), IP42 approved; design refer to EN60950-1
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022,EN61000-3-2 Class A,EN61000-3-3
Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A
MIL-HDBK-217F (25℃)
MTBF
518.9K hrs min.
DIMENSION
84*57*29.5(L*W*H)
0.18Kg; 72pcs/14Kg/0.92CUFT
PACKING
NOTE
90 ~ 264VAC
47 ~ 63Hz
PROTECTION OVER VOLTAGE
OTHERS
1500ms, 40ms / 115VAC at full load
12ms/115VAC at full load
FREQUENCY RANGE
LEAKAGE CURRENT
(Note 5)
Constant current mode power supply
Universal AC input / Full range
Withstand 300VAC Surge input for 5 seconds
Protections:Short circuit / Over voltage
Fully isolated plastic case
Small and compact size
Cooling by free air convection
IP42 design
100% full load burn-in test
Suitable for LED lighting and moving sign applications
Low cost / High reliability
2 years warranty
(only for APC-35-1050) IP42 LPS (except for APC-35-350,APC-35-500)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristic for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6.The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
File Name: APC-35-SPEC 2016-11-10
APC-35
35W Single Output Switching Power Supply
series
Mechanical Specification
Case No.PCD16A
3
Unit:mm
84
150±10
15.3
UL1569 18AWG
57
7.3
150±10
7.3
UL1569 18AWG
AC/N(Blue)
3.6
2 -ψ -ψ8 .9
2
5
15.3
T case 5
AC/L(Brown)
V-(BLACK)
V+(RED)
3
1.9
29.5
※ T case: Max. Case Temperature.
Block Diagram
I/P
fosc : 60KHz
EMI FILTER
POWER
SWITCHING
RECTIFIERS
RECTIFIERS
&
FILTER
+V
-V
DETECTION
CIRCUIT
PWM
CONTROL
Derating Curve
Static Characteristics
100
100
90
80
80
70
50
LOAD (%)
LOAD (%)
60
40
20
-30
0
10
20
30
40
50
AMBIENT TEMPERATURE (℃)
60
70
(HORIZONTAL)
60
50
40
90
100
200
210
220
230
240
250
264
INPUT VOLTAGE (VAC) 60Hz
File Name: APC-35-SPEC 2016-11-10