48Vdc/24Vdc Input, 3.3Vdc@25A Output Quarter-brick Converter AVQ100-36S3V3 ·Description The AVQ100-36S3V3 is a single output DC-DC converter with standard quarter-brick outline and pin configuration. It delivers up to 25A Protection Features z z z z Input under voltage lockout Output over current protection Output over voltage protection Over temperature protection output current with 3.3V output voltage. above 90% efficiency and excellent thermal performance makes it an ideal choice to supply power in telecom and datacom. It can work under -40°C ~ +85°C. 18V ~ 60V wide input range makes it possible for both 24V and 48V power system application. Operational Features z z z z z z z Delivers up to 25A output current High efficiency: 90% (typ., full load, 48V). 92% (typ., half load, 24V) Wide input range: 18V ~ 60V Excellent thermal performance No minimum load requirement Start-up and shut-down monotonically into any normal and pre-biased loads, internal pre-bias function circuit prevents back negative current drawn from external load RoHS 5/6,RoHS 6/6 compliant Control Features z z z Remote control function (negative or positive logic optional) Remote output sense Trim function: 80% ~ 110% Document NO.: 31020993 Mechanical Features z z z Industry standard quarter-brick pin-out outline open frame structure and with baseplate option Pin length option: 3.8mm, 4.8mm, 5.8mm Safety & EMC z z z z Meets safety standards UL 60950-1, CSA-C22.2 NO.60950-1, IEC/EN 60950-1 and GB4943. Approved by UL and TUV. Meets 2006/95/EEC and 93/68/EEC directives which facilitates CE marking in user’s end product Meets conducted emission's requirements of FCC Class (and EN55022 Class A with external filter. August 31, 2011 Rev 2.0 2/15 AVQ100-36S3V3 DC-DC Converter Electrical Characteristics Full operating ambient temperature range is -40°C to +85°C. Specifications are subject to change without notice. Parameter Min. Typ. Max. Unit Notes & Conditions Absolute max. ratings Input voltage Non-operating 80 V 100ms Operating 60 V Continuous Operating temperature -40 85 °C Storage temperature -55 125 °C Voltage at remote ON/OFF pin -0.7 12 V Input characteristics Operating input voltage range 18 48 60 V Turn-on voltage threshold 16.2 16.7 17.2 V Turn-off voltage threshold 14.6 15.1 15.6 V Lockout voltage hysteresis 1.1 1.6 2.1 V Max. input current 6 A No-load input current 0.1 A 0.01 A Remote OFF 0.5 A2s Figure 14 20 mA Through 12µH inductor; Figure 14 15 A Fast blow external fuse recommended; Figure 10 Input under-voltage lockout Standby Input current 0.005 Inrush current transient rating Input reflected ripple current 10 Recommended input fuse 18Vin, full load Input filter component values (C\L) 7.6\2.2 µF\µH Internal values Recommended external input capacitance 100 µF Low ESR capacitor recommended; Figure 10 48Vin, full load Output characteristics Output voltage set point (standard option) Output voltage line regulation Output voltage load regulation 3.267 3.300 3.333 V 0.05 0.15 % 2 5 mV 0.05 0.15 % 2 5 mV http://www.emersonnetworkpower.com.cn 3/15 AVQ100-36S3V3 DC-DC Converter Parameter Min. Output voltage temperature regulation Typ. Max. 0.02 Total output voltage range 3.25 Output voltage ripple and noise Unit Notes & Conditions %/°C 3.30 3.35 V 40 70 mVpp Over sample, line, load, temperature & life Figure 2 20MHz bandwidth; Figure 14 Operating output current range 0 25 A Output DC current-limit inception 27.5 35 A Hiccup: auto-restart when over-current condition is removed Reverse current-limit while enabled 0.5 1.0 2.0 A Negative current drawn from output Reverse current-limit while disabled 0 10 50 mA Negative current drawn from output 90 %Vo 10000 µF Vout pre-bias level Output capacitance 470 470 High frequency and low ESR is recommended Dynamic characteristics Dynamic response Turn-on transient Figure 4 50% ~ 75% ~ 50% Io,max, 0.1A/µs 150 mV Test condition: 25°C, nominal input voltage, see Figure 10 Settling time 100 µs Recovery to within 1% Vo,nom 50% ~ 75% ~ 50% Io,max, 1A/µs 180 mV Test condition: 25°C, nominal input voltage, see Figure 10 Settling time 200 µs Recovery to within 1% Vo,nom Rise time 10 30 ms Full load, Figure 6 Turn-on delay time 5 10 ms Output voltage overshoot 0 Figure 5 %Vo Efficiency 100% load (24Vin) 90 % Figure 1 50% load (24Vin) 92 % Figure 1 100% load (48Vin) 90.5 Figure 1 50% load (48Vin) 90 Figure 1 http://www.emersonnetworkpower.com.cn 4/15 AVQ100-36S3V3 DC-DC Converter Electrical Characteristics (Continued) Parameter Min. Typ. Max. Unit Notes & Conditions Isolation characteristics Isolation voltage (conditions: 1mA for 60s, slew rate of 1500V/10s) 1500 V Basic insulation, pollution degree 2, input to output 1500 V Basic insulation, pollution degree 2, input to baseplate 1500 V Basic insulation, pollution degree 2, output to baseplate Feature characteristics Switching frequency Remote ON/OFF control (positive logic) Remote ON/OFF control (negative logic) 295 300 305 kHz Off-state voltage -0.7 1.2 V On-state voltage 3.5 12 V See Figure 11 Off-state voltage 3.5 12 V On-state voltage -0.7 1.2 V 2.64 3.63 V 0.3 V 5 V Hiccup: auto-restart when over-voltage condition is removed Auto recovery;over-temperature protect(OTP) test point: see Figure 16 Output voltage trim range Output voltage remote sense range Output over-voltage protection 3.8 4.2 Over-temperature shutdown 125 °C Over-temperature hysteresis 5 °C See Trim Characteristics Application Note Reliability characteristics Calculated MTBF (telcordia ) 2.5 106h Telcordia SR-332-2006; 80% load, 300LFM, 40°C Ta http://www.emersonnetworkpower.com.cn of 5/15 AVQ100-36S3V3 DC-DC Converter Electromagnetic compatibility requirements Test Item Conducted Emission Regulations EN 55022 DC input port, Class A Limits Immunity to Electrostatic Discharge IEC/EN61000-4-2 Immunity to Electrical Fast Transient IEC/EN61000-4-4 Enclosure Port, Level 3 DC input port, Level 3 Criteria / B B IEC/EN61000-4-5 Immunity to Surges DC input port Line to Ground(earth): 600V Notes & Conditions See EMC test conditions B Line to Line: 600V Immunity to Continuous Conducted Interference Immunity To Voltage Dips and short interruptions and voltage variations IEC/EN61000-4-6 DC input port, Level 2 EN 61000-4-29 DC input port A B Criterion A: Normal performance during and after test. Criterion B: For EFT and surges, low-voltage protection or reset is not allowed. Temporary output voltage fluctuation ceases after disturbances ceases, and from which the EUT recovers its normal performance automatically. For Dips and ESD, output voltage fluctuation or reset is allowed during the test, but recovers to its normal performance automatically after the disturbance ceases. Criterion C: Temporary loss of output, the correction of which requires operator intervention. Criterion D: Loss of output which is not recoverable, owing to damage to hardware. http://www.emersonnetworkpower.com.cn 6/15 AVQ100-36S3V3 DC-DC Converter Qualification Testing Parameter Unit (pcs) Halt test Test condition 4~5 Vibration Ta,min-10°C to Ta,max+10°C, 5°C step, Vin = min to max, 0 ~ 105% load Frequency range: 5Hz ~ 20Hz, 20Hz ~ 200Hz, A.S.D: 1.0m2/s3, -3db/oct, axes of vibration: X/Y/Z 3 Time: 30min/axis Mechanical shock 3 30g, 6ms, 3axes, 6directions, 3time/direction Thermal shock 3 -40°C to 100°C, unit temperature 20cycles Thermal cycling 3 -40°C to 55°C, temperature change rate: 1°C/min, cycles: 2cycles Humidity 3 40°C, 95%RH, 48h Solder ability 15 IPC J-STD-002C-2007 Characteristic Curves 95 Efficiency (%) 90 85 80 75 70 Vin=24V Vin=48V 65 Vin=60V 60 2.5 5 7.5 10 12.5 15 17.5 Output current (A) 20 22.5 25 Figure 1 Efficiency vs. Output current, Ta=25°C, Vo=3.3V Figure 2 Output ripple & noise (2µs/div, 20mV/div), see Figure 14 for test configuration Figure 3 Input reflected ripple current (2µs/div, 5mA/div), see Figure 14 for test configuration http://www.emersonnetworkpower.com.cn 7/15 AVQ100-36S3V3 DC-DC Converter Figure 4 Dynamic response for 25% load step (50% ~ 75% ~ 50%) and 0.1A/µs slew rate, (1ms/div), see Figure 10 for test configuration; CH1-output voltage (50mV/div); CH2-output current (2A/div) Figure 5 Dynamic response for 25% load step (50% ~ 75% ~ 50%) and 1A/µs slew rate, (1ms/div), see Figure 10 for test configuration; CH1-output voltage (100mV/div); CH2-output current (2A/div) Figure 6 Output voltage startup by power on, (5ms/div), see Figure 10 for test configuration; CH1-output voltage (1V/div); CH2-intput voltage (20V/div) Figure 7 Output voltage shut down by power off, (2ms/div), see Figure 10 for test configuration; CH1-output voltage (1V/div); CH2-input voltage (20V/div) Figure 8 Output voltage startup by remote ON, (5ms/div), see Figure 10 for test configuration; CH1-output voltage (1V/div); CH2-remote ON (2V/div) Figure 9 Output voltage shutdown by remote OFF, (5ms/div), see Figure 10 for test configuration; CH1-output voltage (1V/div); CH2-remote OFF voltage (2V/div) http://www.emersonnetworkpower.com.cn 8/15 AVQ100-36S3V3 DC-DC Converter Application Note Typical Application AVQ100 Fuse EMI filter In+ Out+ CNT Vo+ S+ Trim Vin- SVo- Vin+ C1 C2 Vdc In- Out- C3 C4 Load Figure 10 Typical application C1: 100µF/100V electrolytic capacitor, P/N: UPW2A101MHD (Nichicon) or equivalent caps C2: 1µF/100V X7R ceramic capacitor, P/N: C3225X7R2A105KT0L0U (TDK) or equivalent caps C3: 1µF/25V X7R ceramic capacitor, P/N: C3225X7R1E105KT000N (TDK) or equivalent caps C4: 470µF electrolytic capacitor, P/N: UUD1H471MNL1GS (Nichicon) or equivalent caps Fuse: External fast blow fuse with a rating of 15A. The recommended fuse model is 0324020 MXP from LITTLEFUSE. Remote ON/OFF Either positive or negative remote ON/OFF logic is available in AVQ100-36S3V3. The logic is CMOS and TTL compatible. Below is the detailed internal circuit and reference in AVQ100-36S3V3. 10V Remote ON/OFF 12.4k 10V PWM controller 15k Remote ON/OFF 12.4k 2.0V 10k 10k Negative logic Positive logic Figure 11 Remote ON/OFF internal diagram http://www.emersonnetworkpower.com.cn PWM controller 9/15 AVQ100-36S3V3 DC-DC Converter Trim Characteristics Connecting an external resistor between Trim pin and Vo- pin will decrease the output voltage. While connecting it between Trim and Vo+ will increase the output voltage. The following equations determine the external resistance to obtain the trimmed output voltage. 510 − 10.2( KΩ) ∆ 5.1 × Vnom × (100 + ∆ ) 510 = − − 10.2( KΩ) 1.225 × ∆ ∆ Radj − down = Radj −up ∆= Vnom − Vdesired × 100 Vnom V norm : Nominal output voltage. For example, to get 3.63V output, the trimming resistor is Radj −up = 5.1 × 3.3 × (100 + 10) 510 − − 10.2( KΩ) =89.9KΩ 1.225 × 10 10 The output voltage can also be trimmed by potential applied at the Trim pin. VO = (Vtrim + 1.225) × 2.69 V V Where trim is the potential applied at the Trim pin, and o is the desired output voltage. When trimming up, the output current should be decreased accordingly so as not to exceed the maximum output power and the minimum input voltage should be increased as shown in the following figures. Vo+ S+ Vo+ S+ Load Trim R trim _up Trim Cout Cout S- S- Vo- Vo- Figure 12 Trim up Load R trim _down Figure 13 Trim down Sense Characteristics If the load is far from the unit, connect S+ and S- to the terminal of the load respectively to compensate the voltage drop on the transmission line. See Figure 10. If the sense compensate function is not necessary, connect S+ to Vo+ and S- to Vo- directly. http://www.emersonnetworkpower.com.cn 10/15 AVQ100-36S3V3 DC-DC Converter Input Ripple & Inrush Current And Output Ripple & Noise Test Configuration Probe Current Probe 50mm L1 Vo+ Vin+ C1 C2 Cin C3 DC/DC C4 Load Vdc Vin- Vo- Figure 14 Input ripple & inrush current, ripple & noise test configuration Vdc: DC power supply L1: 12µH Cin: 220µF/100V typical C1 ~ C4: See Figure 11 Note: Using a coaxial cable with series 50Ω resistor and 0.68µF ceramic capacitor or a ground ring of probe to test output ripple & noise is recommended. EMC test conditions U1 In+ U2 Out+ 1320uH 22nF/1000V 1uF/100V Out- In- Vin+ C1 C2 Vo+ C3 DC/DC Vin- C4 VoResistive load EMI filter PE Figure 15 EMC test configuration U1: 5A input EMC filter module U2: Module to test, AVQ100-36S3V3 C1 ~ C4: See Figure 11 http://www.emersonnetworkpower.com.cn 11/15 AVQ100-36S3V3 DC-DC Converter Thermal Considerations The converter is designed to operate in different thermal environments and sufficient cooling must be provided. Proper cooling can be verified by measuring the temperature at the OTP Test Point. The temperature at this point should not exceed the max values in the table. For a typical application, Figure 18 and Figure 19 show the derating of output current vs. ambient air temperature at different air velocity. OTP Test Point Figure 16 Thermal test point Test point Temperature limit OTP Test Point 113°C Figure 17 Typical test condition Forced airflow direction is from Vin- to Vin+ http://www.emersonnetworkpower.com.cn 12/15 AVQ100-36S3V3 DC-DC Converter 25 Output current Io (A) 20 15 10 5 0 25 40 55 70 85 Tem perature: Ta ( ℃ ) 400LFM(2m/s) 300LFM(1.5m/s) 100LFM(0.5m/s) 0LFM(0m/s) 200LFM(1m/s) Figure 18 Output power derating, 48Vin, air flowing across the converter from Vin- to Vin+ 25 Output current Io (A) 20 15 10 5 0 25 40 55 70 85 Tem perature: Ta ( ℃ ) 400LFM(2m/s) 300LFM(1.5m/s) 100LFM(0.5m/s) 0LFM(0m/s) 200LFM(1m/s) Figure 19 Output power derating, 24Vin, air flowing across the converter from Vin- to Vin+ http://www.emersonnetworkpower.com.cn 13/15 AVQ100-36S3V3 DC-DC Converter Mechanical Diagram 15.24 [0.600] 36.8 [1.449] Bottom view 3 4 5 2 6 7 8 1 6-Φ2.0±0.1 L 12.7[0.500]Max. Side view 0.3[0.012]Min. 7.62[0.300] 50.83 [2.001] 15.24 [0.600] 57.9 [2.280] 2-Φ1.5±0.1 6-Φ1.0±0.1 Load board Unit: mm[inch] Bottom view: pin on upside Tolerance: X.Xmm±0.5mm[X.X in.±0.02in.] X.XXmm±0.25mm[X.XX in.±0.01in.] Figure 20 Mechanical diagram Pin length option Device code suffix L -4 4.8mm±0.2mm -6 3.8mm±0.2mm -8 2.8mm±0.2mm None 5.8mm±0.2mm http://www.emersonnetworkpower.com.cn 14/15 AVQ100-36S3V3 DC-DC Converter Pin Designations Pin NO. Name Function 1 Vin+ 2 Remote ON/OFF 3 Vin- Negative input voltage 4 Vo- Negative output voltage 5 S- Negative remote sense 6 Trim 7 S+ Positive remote sense 8 Vo+ Positive output voltage Positive input voltage Remote control Output voltage trim Soldering The product is intended for standard manual or wave soldering. When wave soldering is used, the temperature on pins is specified to maximum 260°C for maximum 7s. When soldering by hand, the iron temperature should be maintained at 300°C ~ 380°C and applied to the converter pins for less than 10s. Longer exposure can cause internal damage to the converter. Cleaning of solder joint can be performed with cleaning solvent IPA or similative. Ordering Information AVQ100 - ① 36 S 3V3 P ② ③ ④ ⑤ - 6 L ⑥ ⑦ ① Model series AVQ: high efficiency quarter brick series, 100: output power 82.5W ② Input voltage 36: 18V ~ 60V input range, rated input voltage 48V ③ Output number S: single output ④ Rated output voltage 3V3: 3V3 output ⑤ Remote ON/OFF logic Default: negative; P: positive logic ⑥ Pin length -6: 3.8mm ⑦ RoHS status L: RoHS, R6; Y: RoHS, R5 Model number AVQ100-36S3V3-6L Description 3.8mm pin length; negative on/off logic; without thread inside mounting hole; R6 compliant http://www.emersonnetworkpower.com.cn 15/15 AVQ100-36S3V3 DC-DC Converter AVQ100-36S3V3P-6L 3.8mm pin length; positive on/off logic; without thread inside mounting hole; R6 compliant AVQ100-36S3V3-6Y 3.8mm pin length; negative on/off logic; with thread inside mounting hole; R5compliant AVQ100-36S3V3P-6Y 3.8mm pin length; positive on/off logic; with thread inside mounting hole; R5 compliant Hazardous Substances Announcement (RoHS Of China) Parts AVQ100-36S3V3 Hazardous substances Pb Hg Cd ○ ○ ○ + Cr6 ○ PBB PBDE ○ ○ ○: Means the content of the hazardous substances in all the average quality materials of the part is within the limits specified in SJ/T-11363-2006 √: Means the content of the hazardous substances in at least one of the average quality materials of the part is outside the limits specified in SJ/T11363-2006 Emerson Network Power Co., Ltd. has been committed to the design and manufacturing of environment-friendly products. It will reduce and eventually eliminate the hazardous substances in the products through unremitting efforts in research. However, limited by the current technical level, the following parts still contain hazardous substances due to the lack of reliable substitute or mature solution: 1. Solders (including high-temperature solder in parts) contain plumbum. 2. Glass of electric parts contains plumbum. 3. Copper alloy of pins contains plumbum http://www.emersonnetworkpower.com.cn